• 제목/요약/키워드: office room

검색결과 289건 처리시간 0.025초

실내사무환경에서의 환경성담배연기(ETS)중 일부 휘발성유기화합물(VOC)에 관한 연구 (A Study on Volatile Organic Compounds(VOC) in Environmental Tobacco Smoke(ETS) at Indoor Office Environments)

  • 하권철
    • 한국환경보건학회지
    • /
    • 제27권3호
    • /
    • pp.87-98
    • /
    • 2001
  • There has been increased interest in the health effects of the Environmental Tobacco Smoke(ETS) as a confirmed human carcinogen. It has been known to be extremely difficult to make an accurate assessment of exposure to ETS since it is consisted of a variety of components and there are a number of labile chemicals. Therefore, it is necessary to obtain, to interpretate and to provide the data of quantitative exposure assessment to ETS in the field of environmental health. The purpose of this research is to evaluate the concentration of ETS using VOC in indoor office environments. The correlations and concentrations of benzene, RSP, 3-EP, nicotine that are indicators for ETS were investigate with smoking density, air change per hour(ventilation rate). Air samples were taken in smoking room(7 sites), smoking allowed office (3 sites), corridor outside smoking room(7 sites), non-smoking office (9 sites). The concentrations of benzene showed significant difference according to category of indoor office environments. The geometric mean concentration of benzene were 23.56 ${\mu}{\textrm}{m}$/㎥(range 4.80~192.90 ${\mu}{\textrm}{m}$/㎥) in smoking rooms. 6.16 ${\mu}{\textrm}{m}$/㎥ in smoking allowed offices, 1.32 ${\mu}{\textrm}{m}$/㎥ in the non-smoking offices respectively. The ratios of the concentration of benzene between outdoor air and smoking room, smoking allowed office, and non-smoking indicators concentrations, SD, and SI were 0.82(benzene and nicotine). 0.76(benzene and RSP), 0.60(benzene and SD), 0.76(benzene and SI). It is proposed that benzene is a good indicator for ETS.

  • PDF

문화행정의 관점에서 본 공공청사 시민문화공간 공간계획 특성 및 개선방안에 관한 연구 - 2000년 이후의 사례를 중심으로 - (A Study on the Plannig Characteristics & Improvement of Citizen Cultural Space in Public Building in terms of Cultural Administration - Focused on the Cases Since 2000's -)

  • 강은진;최상헌
    • 한국실내디자인학회논문집
    • /
    • 제23권2호
    • /
    • pp.174-181
    • /
    • 2014
  • The purpose of the study for this thesis is to look into the status and issues of government office buildings since the self-government policy through comparing and analyzing government office buildings, between domestically and to provide improvement plans of the citizen cultural space and with the self-government budget, enhance the utility and efficiency of the government office buildings and to take a role of a reference in the future when citizen cultural space is formed in the government office buildings. As the result of the study, the space planning characteristics of government office building's citizen cultural space in terms of cultural administration is as follows. First, percentage of room to strengthen the sense of community is small. Therefore, the place where residents can argue there is a need. Second, it is necessary to expand the venue and art collection that are missing in public government buildings. Third, since the lecture room for lack of civic education, it should be taken into account when making cultural space for the citizens. Fourth, thread observatory and souvenir shops, providing information is not enough, it is to be further expanded. Fifth, rented facility for public is hall be provided with a diversity.

Evaluation of Indoor Environmental Factors in Office Building with Underfloor Air-Conditioning (UFAC) System

  • Chung, Kwang-Seop
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.36-45
    • /
    • 2001
  • During the last decade, an increasing interest in Underfloor Air-Conditioning (UFAC) systems has emerged. The purpose of this paper is to evaluate the indoor environmental performance of office buildings with UFAC system in order to develope the design prototype of this system. The physical measurements and the Interviewing survey of occupant's sensation responses to the environment were carried out. Measurements and survey were made of the thermal environmental factors such as air temperature, relative humidity, air velocity, globe temperature, and the other several environmental factors such as the sound level and the illuminance of working plane, etc. And, the air quality was evaluated by measuring the concentration of suspended particles, carbon monoxide, and carbon dioxide in the room. Furthermore, the paper appraises the various indoor environmental factors of the room by using post-occupancy evaluation (POE) method in office building with UFAC system, and thus, it suggests the basic data for assessing the indoor comfort based on field measurements and survey .

  • PDF

방범·방재 기능을 갖는 에너지 절약형 조명기기 구현 (The implement of energy saving illuminator with a function of crime and fire prevention)

  • 한영오
    • 한국전자통신학회논문지
    • /
    • 제5권3호
    • /
    • pp.339-343
    • /
    • 2010
  • 본 연구에서는 방범방재 기능을 갖는 에너지 절약형 조명기기를 개발하였다. 개발된 조명기기와 관리실을 지그비 무선통신으로 연결하여 조명기기에서 획득된 정보를 전송할 수 있어 편리하게 모니터링이 가능하다. 본 조명기기를 교실 또는 사무실 내부에 여러 개의 일반 형광등과 병행하여 1개만 설치하면 학교 또는 일반 건물을 위한 저비용 방범방재 및 에너지절약형 무선 네트워크 시스템 구축이 가능하다.

사무용 건물에서 전열교환 환기시스템과 일반공조기의 냉방에너지 비교분석에 관한 연구 (A Comparative Analysis on Cooling Energy of Heat Recovery Ventilator and Air Handling Unit in the Office Building)

  • 장지훈;김현수;어진선;이승복;김병선
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.123-128
    • /
    • 2016
  • Purpose: In order to save the energy consumption of buildings, buildings have been constructed with high performance insulation or airtightness. However, high performance insulation or air tightness has led to a poor indoor air quality. Therefore, HRV(Heat Recovery Ventilator) has received attention to save the energy consumption and insure a good air quality. Because existing research is almost about the performance of HRV in residential buildings, This study analyzed the effect of HRV on cooling energy consumption in commercial office building. Method: This study was proceeded at commercial office building in In-cheon. In order to evaluate the energy consumption of HRV, this study proposed two methods: estimating energy consumption of the room installed AHU(Air Handling Unit) system; estimating energy consumption of the room installed HRV system. Therefore, comparison of two methods was proceeded to evaluate energy performance of each method. Result: As the result of comparison between rooms installed AHU and HRV, the experiment showed that energy consumption of the room installed HRV system is about 22% less than the room of AHU system. This conclusion is considered because the room installed HRV system have maintained temperature well at set point temperature $26^{\circ}C$.

PMV 제어에 따른 사무소 건물의 실내열환경과 에너지소비량 분석 (Analysis of Indoor Thermal Environment and Energy Consumption in Office Building Controlled by PMV)

  • 장향인;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제33권4호
    • /
    • pp.15-22
    • /
    • 2013
  • The purpose of this study is to analyse the effects of air conditioned room controlled by PMV(Predicted Mean Vote)for energy consumption and human comfort in office building. The 'EnergyPlus' was used for the evaluation of indoor thermal environment and energy consumption by the controls of room temperature and PMV. The result indicates that the PMV control could prove more profitable method for improvement of indoor thermal environment and energy conservation. Consequently, PMV control has a distinct advantage over most other control methods. An additional study is required to establish the various thermal comfort control for rooms on the basis of this work.

재택 근무를 위한 실내 공간의 유형과 디자인에 관한 연구 (A Study on the Prototype and Design Strategy for the Interior Space for the Home Office)

  • 문경하;김형우
    • 한국실내디자인학회논문집
    • /
    • 제21호
    • /
    • pp.69-75
    • /
    • 1999
  • The extensive coverage and high speed of communication network, which is a basic structure of the information society, enables the provision of various forms of informatiov. especially, such services as cyber medicine, cyber education, home office, home banking, and home shopping will be common; and, now, no one can deny that the information society starts to be part of our life. Regarding home office, John Navigate predicted home office through the electronic house in New Mecca Trend and Alvin Toffler asserted in The third Wave that people could do their work anywhere including living room in their hoses with the development of communication technology and other related appliances. Such predictions are realized with the development of information communicatiov. Therefore, housing space should be changed according to the realization of home office and the direction of housing plan need to be set for home office.

  • PDF

'계획에 없던 재수술' 의 분석 (An analysis of unplanned reoperation)

  • 김은경;조성현;김창엽;오병희
    • 한국의료질향상학회지
    • /
    • 제2권1호
    • /
    • pp.118-124
    • /
    • 1995
  • Background: Clinical indicators are objective measures of process or outcome of patient care in quantitative terms. This study aims to review the medical records of patients who 'return to operating room during the same admission', which is one of the critical clinical outcomes, and describe the result by unplanned reoperation rate. Methods: Computerized patient registry was used for selecting subject conditions. For medical records retrieved, two nurse evaluators identified the presence of explicit reoperation planning in medical records. Results: Overall reoperation rate was 2.8% and unplanned reoperation rate 1.3%. The main category of reoperation cause was the postoperative bleeding. Duration of stay from previous operation to reoperation of the unplanned group, 12.7 days, was shorter than that of the planned(p< .05). The differences did not reach statistical significance in age, sex and length of stay. Conclusion: Results suggested that unplanned reoperation rate was lower than 'threshold' level other institutions had established. However, this result could become comparable only after management of medical records would be improved and risk adjusted.

  • PDF

Implementation of A Hospital Information System in Ubiquitous and Mobile Environment

  • Jang, Jae-Hyuk;Sim, Gab-Sig
    • 한국컴퓨터정보학회논문지
    • /
    • 제20권12호
    • /
    • pp.53-59
    • /
    • 2015
  • In this paper, we developed a Hospital Information System in which the business process is formalized and a wire/wireless integrated solution is used. This system consists of the administration office program, the medical office program, the ward management program and the rounds management program. The administration office program can enroll and accept patients, issue and reissue the RFID card. The medical office program inputs a medical examination and treatment, outputs a diagnosis, requests a hospitalization, retrieves the record of a medical examination and treatment, assigns the corresponding examination room to the accepted patients, and updates the number of an waiting patient and a patient number according to the examination room on real time. The ward management program handles hospitalizations and leaving hospital, a nurse's note, and an isolation ward monitoring. The rounds management program handles a medical examination and treatment, and a leaving hospital using PDA. This developed system can be built at low cost and increase the quality of the medical services highly by making it automated the medical administration automation. Also the small number of the medical staffs can manage the inpatients efficiently by using the monitoring functions.