• Title/Summary/Keyword: off-level test

Search Result 239, Processing Time 0.029 seconds

Breeding of New Productive Bivoltine Hybrid, CSR12 $\times$ CSR6 of Silkworm Bombyx mori L.

  • Datta, R.K.;Basavaraja, H.K.;Reddy, N.Mal;Kumar, S.Nirmal;Kumar, N.Suresh;Babu, M.Ramesh;Ahsan, M.M.;Jayaswal, K.P.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.3 no.2
    • /
    • pp.127-133
    • /
    • 2001
  • With an objective of evolving quantitatively and qualitatively superior bivoltine breeds/hybrids of silkworm Bombyx mori L. for tropical conditions, breeding work was initiated in Central Sericultural Research and Training Institute, Mysore during 1992 by utilizing two Japanese hybrids namely BNl8$\times$BCS25 and Shunrei$\times$Shogetsu along with Indian evolved breed, KA. The breed CSR12 which is characterized with sex-limited larval marking and white oval cocoons was evolved from the Japanese hybrid BNl8 ${\times}$ BCS25 by crossing with KA, while the breed CSR6 which is characterized with normal marking (marked larvae) and white dumbbell cocoons was extracted from the Japanese commercial hybrid Shunrei${\times}$Shogetsu through continuous inbreeding coupled with selection. After fixation, these breeds along with other newly evolved breeds were subjected to hybrid study under optimum environmental conditions in the laboratory for expression of full potential of the genotypes. These hybrids were evaluated by Multiple Trait Evaluation Index (Mano et al., 1993). The hybrid CSR12${\times}$CSR6 was selected based multiple trait evaluation index value. The hybrid CSR12$\times$CSR6 recorded survival of 96.0%, shell weight of 50.0 cg, shell ratio of 24.3%, raw silk percentage of 19.6, filament length of 1,216 m, boil off loss of 22.4% and renditta of 5.1. On the other hand, the control hybrid (KA ${\times}$ NB4D2) has recorded survival of 90.6%, shell weight of 42.1 cg, shell ratio of 20.4%, raw silk percentage of 15.9, filament length of 999 m, boil off loss of 24.8% and renditta of 6.3. The hybrid CSR12$\times$CSR6 was authorized during 1997 by Central Silk Board, Government of India for commercial exploitation during favourable months based on national level race authorization test.

  • PDF

Hybrid Rocket Thrust Control in an Environment With Decreasing Oxidizer Supply Pressure (산화제 공급압력이 감소하는 환경에서 하이브리드 로켓 추력제어)

  • Chae, Donghoon;Chae, Heesang;Lee, Changjin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.5
    • /
    • pp.325-332
    • /
    • 2022
  • The vertical take-off and vertical landing (VTVL) function is essential to carry out exploration missions on the moon or Mars. For this, the engine of the exploration vehicle must have appropriate thrust control accuracy and response time. The hybrid rocket engine (HRE) is known to have a high level of thrust control capability that can satisfy these conditions. This study aims to first verify whether the thrust control performance of the developed HRE is suitable for VTVL. To this end, an oxidizer supply system that does not use a pressurization device was adopted, aiming for a mission time of about 10 seconds. In this study, the thrust control characteristics appearing under various supply pressure decreasing conditions were identified through experiments. Appropriate tank and charging conditions were set from the experimental results. In addition, the results of previous studies and current study's test were compared to confirm whether the developed HRE had adequate control performance for VTVL, and finally, the thrust control performance was verified through altitude control simulation.

Solidification of high level waste using magnesium potassium phosphate compound

  • Vinokurov, Sergey E.;Kulikova, Svetlana A.;Myasoedov, Boris F.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.755-760
    • /
    • 2019
  • Compound samples based on the mineral-like magnesium potassium phosphate matrix $MgKPO_4{\times}6H_2O$ were synthesized by solidification of high level waste surrogate. Phase composition and structure of synthesized samples were studied by XRD and SEM methods. Compressive strength of the compounds is $12{\pm}3MPa$. Coefficient of thermal expansion of the samples in the range $250-550^{\circ}C$ is $(11.6{\pm}0.3){\times}10^{-6}1/^{\circ}C$, and coefficient of thermal conductivity in the range $20-500^{\circ}C$ is $0.5W/(m{\times}K)$. Differential leaching rate of elements from the compound, $g/(cm^2{\times}day)$: $Mg-6.7{\times}10^{-6}$, $K-3.0{\times}10^{-4}$, $P-1.2{\times}10^{-4}$, $^{137}Cs-4.6{\times}10^{-7}$; $^{90}Sr-9.6{\times}10^{-7}$; $^{239}Pu-3.7{\times}10^{-9}$, $^{241}Am-9.6{\times}10^{-10}$. Leaching mechanism of radionuclides from the samples at the first 1-2 weeks of the leaching test is determined by dissolution ($^{137}Cs$), wash off ($^{90}Sr$) or diffusion ($^{239}Pu$ and $^{241}Am$) from the compound surface, and when the tests continue to 90-91 days - by surface layer depletion of compound. Since the composition and physico-chemical properties of the compound after irradiation with an electron beam (absorbed dose of 1 MGy) are constant the radiation resistance of compound was established.

The effects of aircraft noise on the hearing loss, blood pressure and response to psychological stress (군용 항공기 이륙소음이 청력, 혈압, 스트레스 및 주관적 인지도에 미치는 영향)

  • Han, Sang-Hwan;Cho, Soo-Hun;Koh, Kyung-Shim;Kwon, Ho-Jang;Ha, Mi-Na;Ju, Yeong-Su;Shin, Myung-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.2 s.57
    • /
    • pp.356-368
    • /
    • 1997
  • In effort to determine whether aircraft noise can have health effects such as hearing loss, hypertension and psychological stress, a total of 111 male professors and administrative officers working a college near a military airport in Korea(exposed group) and a total of 168 males and 112 females matched by age groups(control groups) were analyzed. Personal noise exposure and indoor and outdoor sound level of jet aircraft noise were measured at the exposed are3. And pure tone, air conduction test and measurement of blood pressure were given to the exposed(males) and matched control groups (males and females). BEPSI(Brief Encounter Psychological Instrument) and psychological response to aircraft noise were examined for the exposed group. The noise dosimetry results revealed time-weighted averages(TWAs) that ranged from 61 to 68 dBA. However the levels encountered during taking off jet airplanes reached 126 dBA for two half minutes time period. Th, audiometric, test showed that mean values of HTL(hearing threshold level) in exposed group at every frequency(500, 1,000, 2,000, 4,000, and 8,000 Hz were much lower than them of male and female control groups. And in old age groups, interaction of age and noise was observed at 8,000 Hz in both ears(p<0.05). Conclusively, aircraft noise does not appear to induce hearing loss directly in high frequency, but may decreased hearing threshold level by interaction of aging process and noise exposure. However, difference of mean values of exposed and control groups on blood pressure was not significantly. In psychological test, annoyance was the most severe psychological response to noise in exposed group, but mean value of BEPSI was not correlated with job duration in exposed group.

  • PDF

Comparison of Subjective Refraction Findings in Two Different Levels of Room Illumination Using Three Different Types of Letter Charts

  • Chen, Ai-Hong;Norazman, Fatin Nur Najwa;Buari, Noor Halilah;Ahmad, Azmir;Omar, Wan Elhami Wan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.67-71
    • /
    • 2010
  • Purpose: The effect of two different levels of illumination and the effect of three letter chart types on subjective refraction findings were investigated. Methods: This study involved thirty Malay university students aged between 19 to 23 years old (7 males, 23 females), with their spherical refractive error ranged between plano to -7.75D astigmatism ranged from plano to -1.75D, anisometropia less than 1D and with no history of ocular injury and pathology. Monocular subjective refraction was measured under two levels of illumination (with and without room light) and with three different letter charts (Snellen letter chart, wall mounted letter chart and projected letter chart). Subjective refraction finding was calculated in spherical equivalent in unit diopter (D). Results: There was no significant effect in the subjective refraction findings with Snellen letter chart (t-test=0.15, p-value=0.88), projected letter chart (t-test=-0.19, p-value=0.85) as well as wall mounted letter chart (t-test=0.12, p-value=0.94). One Way ANOVA also revealed when the subjective refractive measures were compared under two different level of room illumination (with and without room light), no significant effect of letter chart types on subjective refraction readings with room light ($F_{2.185}$=0.11, p-value=0.89) and without room light ($F_{2.185}$=0.02, p-value=0.98). Conclusions: Subjective refraction findings were not affected whether the room light was on or off. They were also not affected by the types of letter chart used.

A Study on Breast Cancer self-examination Compliance in the Context of Health Belief Model (유방암 자가검진에 영향을 미치는 요인에 관한 연구 - 건강신념 모형을 중심으로 -)

  • 김미경;김초강
    • Korean Journal of Health Education and Promotion
    • /
    • v.7 no.1
    • /
    • pp.64-71
    • /
    • 1990
  • The purpose of this study is to identify the main factors influencing breast cancer self-examination, a preventive health behavior, thereby increasing self-examination compliance for early detection of the disease. The data on which this study was based were collected from a survey of 601 ladies, aged 20∼59 years and residing in Seoul, employing such mehtods as X²-test, ANOVA, t-test, F-test, Person's Correlation Coefficient and Stepwise Multiple Regression. The resulting conclusions are as follows; 1. Discrepancies in self-examination compliance rate are found in accordance with the differences of general characters of the surveyed persons. For instance, those who are well educated and better off are better compliers than those who are not (p<0.001), and those around whom breast cancer patients are better ones than who are not (p<0.01). 2. Self-examination compliers have higher health belief than non-compliers. Compliers have more knowledge in health and have higher susceptibility, barriers and health concern (p<0.001), and higher benefits (p<0.01), and higher seriousness (p<0.05) than non-compliers. 3. Whereas those who have loftier health belief show higher compliance rate (p<0.001), seriousness turned out to have no correlationship with self-examination compliance. 4. Stepwise Multiple Regression portray that following factors influence self-examination compliance in arder named. (1) barriers (2) susceptibility, (3) health concern, (4) age, (5) benefits, (6) education level. Even so, it turned out that these factors alone can explain only 20% of self-examination compliance. Therefore study for the other factors ought to be continued. I submit following suggestions ending this study. 1. Since breast cancer self-examination is an essential health behavior needed for early detection of the disease, efficient and proper health education program eyed for regular and periodic self-examination is required to be developed, thus reducing the deaths and pains caused by the disease. 2. Proper policies of the government for the prevention of breast cancer is strongly urged to be formed in concrete manner. 3. Continuous study of the other factors affecting self-examination compliance must be carried on.

  • PDF

A Study on effect that position of contact area at adjacent side has on fractures of porcelains in case of porcelain fused to metal crown (금속 소부 도재관의 경우 인접면에서 접촉점의 위치가 도재 파절에 미치는 영향에 관한 연구)

  • Kim, Yong-Won
    • Journal of Technologic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.173-180
    • /
    • 2007
  • There was a great problem about the deposition between materials of a different kind at the beginnings of the introduction of porcelains, however, thereafter the deposition efficiency was settlded to the sufficient level of all user thanks to effort to have studied by many scholars and clinical authorities. But in a clinical process, as the difference of designs has an effect on fractures of porcelains, this researcher divided them into 4 groups of A: 1 mm, B: 2 mm, C: 3 mm, and D: 4 mm, and made 40 pieces to each 10 as the test samples to consider a length axis of tooth for studies in accordance with a position of a finishing line to meet between porcelain and metal at the contact point at the adjacent side to a metal porcelain. The sample materials are those to be use at the open market and the test samples wer completed by the same manufacturing technique to that of existent metal porcelain tube. s a result of the strength test on fractures, the average value is as in the following, A: 1 mm - 8.5bar, B: 2 mm - 10.5bar, C: 3 mm - 14.3bar, and D: 4 mm - 15.0bar. In case of the metal porcelain tube, the more faraway to process parts of metal and porcelain from the contact point of adjacent side has the stronger strength of fractures, Accordingly, the research shows that it had better to keep off more than 3 to consider a ledngth axis of tooth.

  • PDF

A Study on the Chattering under Cryogenic Flow Test of a Oxidizer Shutoff Valve (산화제 개폐밸브의 극저온 유동시험에서 채터링의 고찰)

  • Lee, JoongYoup;Han, SangYeop;Lee, SooYong
    • Aerospace Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.108-117
    • /
    • 2013
  • The oxidizer shutoff valve of a gas generator controls the mass flow rate of the propellant of a rocket engine using pilot pressure and spring the force of the valve. The developing oxidizer shutoff valve can be shut off if the pilot pressure is removed from the actuator. Therefore, force balancing is necessary to analyze the characteristics of the forces with respect to the opening and closing of the valve in order to evaluate its performance. In light of this, the valve has been designed to adjust the control pressure required to open the poppet and to determine the working fluid pressure at which the valve starts to close. Under cryogenic flow test as a tests level of C.R.T(Control Random Test), the chattering phenomena occurred due to much leakage of a metal seat section. The pressure for chattering of the oxidizer valve is predicted at about 11 bar using force balancing analysis.

Safety Effect of Cosmetics Containing Coptis Japonica Extract on Sensitive Skin (황련 추출물을 함유한 화장품의 민감성 피부 안전성 연구)

  • Kyung Nam Min
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.3
    • /
    • pp.453-461
    • /
    • 2023
  • This study was to verify the skin safety of Coptis Japonica extract(CJE) -containing cosmetics by patching them on sensitive skin and checking its stimulating level. 32 subjects diagnosed with sensitive skin by the result of the lactic acid injury test, were subjected to 20 ㎕ of solubilized essence mixed with 2% CJE on the test subjects' back and closed patched for 24 hours. No stimulus reactions were found by bare eyes and scored 0 stimulus figure points after they were taken off in 30 minutes, 24 hours, and 48 hours. Coptis japonica's medical efficacies such as antioxidant, and anti-inflammatory are expectable to be used as functional cosmetics, and this research would be the foundation of further research into its cosmetical usage.

Effectiveness of Road Lighting on Driver' Vision (도로조명 방식이 운전자 시지각에 미치는 영향)

  • Jeong, Jun-Hwa;Lee, Suk-Ki;Kim, Won-Sik;Lee, Mi-Ae
    • International Journal of Highway Engineering
    • /
    • v.14 no.4
    • /
    • pp.125-131
    • /
    • 2012
  • PURPOSES : Road lighting facilities increase the visibility of road at night in order to improve traffic driver safety and comfort. Generally speaking, current pole lighting has a tendency to create problems of glare and flicker. The phenomenon of glare gives discomfort due to increase of scattered light, when high luminance is in driver's field of view. The phenomenon of flicker occurs due to the driver passing through discontinuous pockets of pole lighting areas. These phenomenon increase eye strain and decrease driver safety. METHODS : Low height line lighting that distributes light lower than driver's eye level has been developed and evaluated to reduce the problems linked to current pole lighting. A test was undertaken with 4 conditions(turn on the general pole lighting, turn off alternate pole lighting, turn on the line lighting and line lighting with 50% dimming). A driver written survey was conducted in order to gain driver feedback. RESULTS : Pupil size and brow frequency compared with degree in pole lighting are reduced. CONCLUSIONS : Low height line lighting environment makes drivers more comfortable than pole lighting environment and is positive lighting method in the energy saving and landscape aspect.