• Title/Summary/Keyword: off-axis test

Search Result 59, Processing Time 0.021 seconds

Experimental study on the performance of urban small vertical wind turbine with different types (도시형 소형 수직축 풍력 발전기의 형태별 성능에 대한 실험적 고찰)

  • Kang, Deok-Hun;Shin, Won-Sik;Lee, Jang-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.6
    • /
    • pp.64-68
    • /
    • 2014
  • This paper is intended to provide experimental data for the design of the small VAWT(vertical axis wind turbine). Three types(lift, drag, and hybrid) of the blade of VAWT are tested with digital wind tunnel in this study. From the test, the relation of power coefficient and tip speed ratio for the blades are evaluated and compared each other depending on the blade type. Especially, the characteristics of hybrid blade which is shown to be expanded in the market without any logical data is proposed in the relation of power coefficient and tip speed ratio. It is shown that the hybrid blade can be used to make higher starting torque with trade off of degradation of power coefficient.

Propeller Performance Analysis for Human Powered Aircraft (인간동력 항공기용 프로펠러 성능해석)

  • Park, Poo-Min
    • Aerospace Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.193-201
    • /
    • 2013
  • Propeller is an important component of Human Powered Aircraft (HPA) propulsion system. HPA uses large diameter low rotational speed propeller to get high propeller efficiency. The propeller was designed by HPA propeller designing program. The propeller pitch is adjustable by rotating the blade axis angle at ground. Performance of the propeller for various parameters are analysed by the same program used for design. Off-design condition performance was also checked including pilot power change and flight speed change. The propeller was manufactured in ultra-light structure using carbon composite material down to 950g. The propeller was ground tested on ironbird and installed on KARI HPA. Finally the HPA flew 291m with this propeller.

The Characteristics and Optical Implementation of OA-pSDF BPOF (OA-pSDF BPOF의 특성 및 광학적 구현)

  • 임종태;박성균;엄주욱;박한규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.8
    • /
    • pp.1433-1445
    • /
    • 1994
  • In this paper, an coherent optical correlator system based on the off-axis projection synthetic discriminant funtion (OA-pSDF) was analyzed and implemented optically. The filter was synthesized by combining conventional pSDF with single reference plane wave multiplexing. Synthesized pSDF were transformed to binary phase only filters (BPOFs) and fabricated as computer generated holograms(CGHs), which was used in the real time optical correlator system instead of using expensive spatial light modulators(SLMs). From the characteristic test, it was found that OA-pSDF showed distortion invariance and good performances in discrminating subset images. The proposed OA-pSDF BPOF could overcome the limitations of conventional BPOFs : that is distortion variance such as acale and rotation, especially out of plane variance.

  • PDF

Application of an imaging plate to relative dosimetry of clinical x-ray beams (Imaging Plate를 이용한 의료용 광자선의 선량측정)

  • 임상욱;여인환;김대용;안용찬;허승재;윤병수
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.117-122
    • /
    • 2000
  • The IP(imaging plate) has been widely used to measure the two-dimensional distribution of incident radiation since it has a high sensitivity, reusability, a wide dynamic range, a high position resolution. Particularly, the easiness of acquiring digitized image using IP poses a strong merit because recent trend of data handling prefers image digitization. In order to test its usefulness in photon beam dosimetry, we measured the off-axis ratio(OAR) on portal planes and percent depth dose(PDD) within a phantom using IP, and compared the results with the data based on EGS4 Monte Carlo particle transport code, ion-chambers, conventional films. For the measurement, we used 6 MV X-rays, various field sizes. As a result, IP showed significant deviation from ion-chamber measurement: a significant overresponse, 100% greater than that of ion-chamber measurement at deep part of the phantom. Filtration of low-energy scattered photons at deep part of the phantom using 0.5 mm thick lead sheets did improve the result, only to the unacceptable extent. However, portal dose measurement showed possibilities of If as a dosimeter by showing errors less than 5%, as compared with film measurement.

  • PDF

MANUFACTURING AND TEST RESULTS OF OFF-AXIS PARABOLIC CYLINDER MIRROR FOR FIMS (FIMS에 사용되는 비축 포물 원통형 반사경의 제작과 성능 시험 결과)

  • Ryu, K.-S.;Yuk, I. S.;Seon, K.-I.;Lee, Y.-W.;Nam, U.-W.;Shin, J.-H.;Hong, S.-J.;Lee, D.-H.;Jin, H.;Oh, S.-H;Rhee, J.-G.;Min, K.-W.;Han, W.;Park, J.-H.;Edelstein, J.;Korpela, E. J.
    • Journal of Astronomy and Space Sciences
    • /
    • v.18 no.3
    • /
    • pp.239-248
    • /
    • 2001
  • Far-ultraviolet IMaging Spectrograph (FIMS) is the main payload of the first Korean scientific satellite, KAISTSAT-4, which will be launched in 2002. Among the optical parts, parabolic cylinder mirror does not have any heritage from previous astronomical missions, so the manufacturing and testing process itself is a challenging issue. We describe the method of manufacturing and measuring of the off-axis parabolic cylinder mirror and our initial experiments to establish the entire manufacturing process. Using the method, the profile error can meet the specification of $lambda$ per cm which is closely related with the astronomical performances. In case of the surface roughness, temperature controlled pitch polishing reduces $R_{q}$ under 1 nm implying that scattering in the entire spectral range of FIMS is less than 2% of the incident UV light.

  • PDF

A Comparison Study of Volumetric Modulated Arc Therapy Quality Assurances Using Portal Dosimetry and MapCHECK 2

  • Jin, Hosang;Jesseph, Fredrick B.;Ahmad, Salahuddin
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.65-71
    • /
    • 2014
  • A Varian Portal Dosimetry system was compared to an isocentrically mounted MapCHECK 2 diode array for volumetric modulated arc therapy (VMAT) QA. A Varian TrueBeam STx with an aS-1000 digital imaging panel was used to acquire VMAT QA images for 13 plans using four photon energies (6, 8, 10 and 15 MV). The EPID-based QA images were compared to the Portal Dose Image Prediction calculated in the Varian Eclipse treatment planning system (TPS). An isocentrically mounted Sun Nuclear MapCHECK 2 diode array with 5 cm water-equivalent buildup was also used for the VMAT QAs and the measurements were compared to a composite dose plane from the Eclipse TPS. A ${\gamma}$ test was implemented in the Sun Nuclear Patient software with 10% threshold and absolute comparison at 1%/1 mm (dose difference/distance-to-agreement), 2%/2 mm, and 3%/3 mm criteria for both QA methods. The two-tailed paired Student's t-test was employed to analyze the statistical significance at 95% confidence level. The average ${\gamma}$ passing rates were greater than 95% at 3%/3 mm using both methods for all four energies. The differences in the average passing rates between the two methods were within 1.7% and 1.6% of each other when analyzed at 2%/2 mm and 3%/3 mm, respectively. The EPID passing rates were somewhat better than the MapCHECK 2 when analyzed at 1%/1 mm; the difference was lower for 8 MV and 10 MV. However, the differences were not statistically significant for all criteria and energies (p-values >0.05). The EPID-based QA showed large off-axis over-response and dependence of ${\gamma}$ passing rate on energy, while the MapCHECK 2 was susceptible to the MLC tongue-and-groove effect. The two fluence-based QA techniques can be an alternative tool of VMAT QA to each other, if the limitations of each QA method (mechanical sag, detector response, and detector alignment) are carefully considered.

The Performance of Flight Model of the NISS onboard NEXTSat-1

  • Jeong, Woong-Seob;Moon, Bongkon;Park, Sung-Joon;Lee, Dae-Hee;Pyo, Jeonghyun;Park, Won-Kee;Kim, Il-Joong;Park, Youngsik;Ko, Kyeongyeon;Kim, Mingyu;Kim, Minjin;Ko, Jongwan;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shin, Goo-Hwan;Chae, Jangsoo;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.58.1-58.1
    • /
    • 2017
  • The NISS (Near-infrared Imaging Spectrometer for Star formation history) is the near-infrared spectro-photometric instrument optimized to the first Next Generation of small satellite (NEXTSat-1). The off-axis optics was developed to cover a wide field of view with 2 deg. ${\times}$ 2 deg. as well as a wide wavelength range from 0.95 to $2.5{\mu}m$. Considering the simple alignment scheme, afocal system was adapted in the optical components. The mechanical structures were tested under the space environment. We have obtained the accurate calibration data using our test facilities under the operational condition. After the final integration of flight model into the satellite, the communication with the satellite and the functional test were passed. The NISS will be launched in early 2018. During around 2-year operation, the spectro-photometric survey covering more than 100 square degree will be performed. To achieve the major scientific objectives for the study of the cosmic star formation in local and distant universe, the main observational targets will be nearby galaxies, galaxy clusters, star-forming regions and low background regions. Here, we report the final performance of the flight model of the NISS.

  • PDF

Analysis on Foot Measurements of Elderly Women for Ergonomic Shoes Design (인간공학적 신발설계를 위한 노년여성 발측정치 분석)

  • Park, Soon-Jee;Chae, Hye-Seon
    • Fashion & Textile Research Journal
    • /
    • v.10 no.1
    • /
    • pp.83-91
    • /
    • 2008
  • This study was designed to figure out the changes in elderly women's foot size and shape by aging, to propose size specification for elderly women's shoes, and to produce regression equations using representative measurements items to estimate other measurements usually hard to get. Subjects were 118 women of 30-59 years and the 227 elderly women over 60 years. Martin's anthropometry was done on the right foot of each subject for 25 items. And 11 indirect measurement items were measured on both foot printing sole outline and picture in profile taken by digital camera. For statistical analysis on the anthropometric measurements by SPSS program, analysis of variance, post-hoc test(SNK-test), crosstabulation, multiple correlation analysis, regression analysis were performed. The results of the study are as follows. Firstly, it was found that the foot figures of elderly women over 60 years were smaller in girth and width than those of below 60 years. In addition, it was revealed that a big toe and a little toe of elderly women showed a tendency concentrating to the central axis of feet. The foot index of elderly was smaller in width and girth. Secondly, foot size distribution table of elderly group showed wider size ranges and covered smaller sizes than the below the age of 60, meaning wide variation in foot size of elderly women. Thirdly, the multiple correlation analysis showed high correlation of foot length/girth to other measurements, suggesting these two items could be used as representative items for elderly women's shoe size specification as other age groups. Regression equations were produced using foot length/girth to estimate other measurements, suggesting such items could be estimated effectively and utilized in on/off-line shoe manufacturing shop as heel to big toe length, heel to little toe length, exterior malleouls width, instep girth, ankle girth, etc. These results imply prudent features of elderly women's foot as diversity of foot shape and wide size specification range should be applied for ergonomic shoe design for them.

MTF and wavefront error testing of large aperture optical system using unequal path interferometer (경로길이 불일치 간섭계를 이용한 대구경 광학계의 MTF 측정과 파면오차 검사)

  • Song, Jong-Sup;Jo, Jae-Heung;Lee, Yun-Woo;Song, Jae-Bong;Yang, Ho-Soon;Lee, In-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.50-55
    • /
    • 2005
  • A method for measuring the wavefront error and the modulation transfer function(MTF) of large aperture optics using an unequal path interferometer is presented. A bidirectional shearing interferometer is used for collimation testing of the measurement system. A large aperture Fizeau interferometer with long optical path difference measures the wavefront error of the optics under test by using a $\Phi$ 400 mm off-axis parabolic mirror. The MTF is also measured at the wavelength of the interferometer by changing the laser light into partially incoherent light. Test results of a $\Phi$ 300 mm Cassegrain type satellite telescope made in Korea are presented.

Design and Fabrication of a small Coaxial Rotorcraft UAV (동축반전 헬리콥터형 소형 무인항공기 설계 및 제작)

  • Kim, Sang-Deok;Byun, Young-Seop;Song, Jun-Beom;Lee, Byoung-Eon;Song, Woo-Jin;Kim, Jeong;Kang, Beom-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.3
    • /
    • pp.293-300
    • /
    • 2009
  • The rotorcraft-based unmanned aerial vehicle(UAV) capable of performing close-range surveillance and reconnaissance has been developed. Trade studies on mission feasibility led to the adoption of a coaxial rotorcraft with twin rotors counter-rotating in one axis and driven by electric motors. A commercial off-the-shelf flight control computer(FCC) and a radio frequency modem were adopted for autonomous navigation. In order to achieve an aerial view, commercial charge-coupled device camera was also integrated into the vehicle. The performance of the completed vehicle was proved with manual flight test, and mission capability was verified through waypoint navigation flight after being equipped with FCC. This paper treats the whole process of design and system integration for development of the coaxial rotorcraft UAV.