• Title/Summary/Keyword: off-axis test

Search Result 59, Processing Time 0.023 seconds

Radiochromic film dosimetry for linac-based stereotactic radiosurgery

  • Han, Seung-Hee;Park, Suk-Won;Oh, Do-Hoon
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.302-304
    • /
    • 2002
  • In linac-based stereotactic radiosurgery, assuring the quality of the planning and delivery of external photon beam requires accurate evaluation of beam parameters, usually including output factors, tissue-phantom ratio and off-axis ratios, and measurement of actual dose distributions from simulated treatment. We're going to test the use of calibrated radio chromic film (Gafchromic film; type MD-55, Nuclear associate) using a Lumiscan 75 digitizer to measure absolute dose and relative dose distributions for linac-based radiosurgery unit Relative dose distribution of a human-style spherical acryl phantom were measured using radiochromic film and calculated by treatment planning system. The absolute dose at the sphere center was measured by radiochromic film and micro chamber (Exradin A-14, 0.009cc). What we want to demonstrate in this work, the 'well selected' radiochromic films when external photon beam are used in linac-based stereotactic radiosurgery are very accurate detector for dosimetry.

  • PDF

Optical Performance Measurement of the MATS Satellite

  • Park, Woojin;Hammar, Arvid;Lee, Sunwoo;Chang, Seunghyuk;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.49.1-49.1
    • /
    • 2018
  • The MATS (Mesosphere Airglow/Aerosol Tomography Spectroscopy) satellite is the next Swedish science microsatellite. We report optical performance test results of the limb telescope, which is the major payload. This telescope is designed with "linear astigmatism-free" (LAF) off-axis optical system in order to have high optical performance across the wide field of view. We measured Modulation Transfer Function (MTF) and Encircled Energy Diameter (EED) of the limb telescope. Full field imaging tests show expected results without linear astigmatism across the full field of view ($5.67^{\circ}{\times}0.91^{\circ}$). Since the amount of stray light is from the earth and the sun, we also simulated and measured the stray light in the field image.

  • PDF

Test Result of Off-axis Parabolic Cylinder Mirror for FIMS (FIMS에 사용되는 비축 포물 원통 반사경의 간섭계 측정)

  • ;;Jerry Edelstein
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.86-87
    • /
    • 2001
  • Far-ultraviolet IMaging Spectrograph(이하 FIMS)는 2002년에 발사 예정인 과학위성 1호의 주 탑재체이며, 은하 주변에 분포한 고온의 가스에서 방출되는 자외선 영역 (short wavelength band : 900-1150 $\AA$, long wavelength band : 1335-1750$\AA$)의 방출선을 약 2$\AA$의 분광 분해능으로 관측하는 천문학적 목표를 가지고 있다 일반적인 망원경을 사용하는 대신 제한된 위성의 크기 내에서, 넓은 지역에 퍼져 있는 가스의 분포와 특성을 관측하는데 적합하도록, 그림 1과 같이 비축 포물 원통 반사경과 타원형의 substrate를 가진 회절 에돌이발 (grating)의 사용을 고안하였다. (중략)

  • PDF

Design of null lenses for testing of hyperbolic surfaces (쌍곡면 측정 null 렌즈 설계)

  • 김연수;김병윤;이윤우
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.5
    • /
    • pp.352-355
    • /
    • 2001
  • A null lens is designed for testing the hyperbolic mirror which is the first mirror of the off-axis three mirror anastigmat(TMA) designed as a high resolution camera for remote sensing. To choose a better null lens system for the hyperbolic surface under test, both autostigmatic and mixed type null lenses are designed and analysed for sensitivity with respect to change of each surface parameter such as the radius of curvature and the thickness.

  • PDF

로켓 모션테이블 실시간 모의시험

  • Sun, Byung-Chan;Park, Yong-Kyu;Choi, Hyung-Don;Cho, Gwang-Rae
    • Aerospace Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.170-178
    • /
    • 2004
  • This paper deals with six degree-of-freedom HILS(hardware-in-the-loop-simulation) of KSR-III rocket using a TAFMS(three axis flight motion simulator). This TAFMS HILS test is accomplished before main HILS tests in order to verify the control stability in the presence of TAFMS dynamic effects. The TAFMS HILS test includes initial attitude holding tests for INS initial alignment procedures, timer synchronization tests with an auxiliary lift-off signal, real-time calibration tests using an external thermal recorder, open-loop TAFMS operating tests, and final closed-loop TAFMS HILS tests using the TAFMS attitude measurements as inputs to the closed control loop. The HILS tests are accomplished for several flight conditions composed with nominal flight condition, TWD effect added condition, slosh modes and/or bending modes existing condition, and windy condition, etc.

  • PDF

Male Parental Care, Egg and Larval Development of the Smoky Damselfish, Chromis fumea (Pisces: Pomacentridae) (연무자리돔, Chromis fumea (Pisces: Pomacentridae)의 산란보호, 난발생 및 자어의 형태발달)

  • Kim, Jin-Koo;Kim, Yong-Uk;Park, Jin-Woo
    • Korean Journal of Ichthyology
    • /
    • v.13 no.3
    • /
    • pp.166-172
    • /
    • 2001
  • Parental care of eggs of Chromis fumea (Tanaka) was observed by Skin Scuba gear in August 1995 off Cheju Island. The eggs and larval development were observed in the laboratory at Pukyong National University, Pusan. Eggs were deposited on a flat surface of hard substratum and formed a plain sheet of one layer of eggs. Males showed parental care of the eggs by hovering over the nest and attacking other fishes that approached the nest. The spawned eggs were transparent, elliptical in shape and measured 0.73~0.88 mm in long axis and 0.50~0.56 mm in short axis. An analysis by T-test of the long axis of the egg with time showed a significant difference (p<0.01). However, there was no significant difference in short axis with time. Eggs were reared at water temperatures of $23.0{\sim}25.5^{\circ}C$ and took about 4~5 days from embryonic body stage to hatching. The newly hatched larvae were 1.10~1.61 mm in notochord length (NL) had 21 myomeres, has closed mouth but open anus, preanus length was 45.8% of NL. Melanophores were distributed on the occipital region of head, the eye, the peritoneal region, and along the ventral contour. The larvae absorbed the yolk material and oil globule in 3~4 days after hatching and became postlarvae. On the third day after hatching, the larvae had attained 1.9~2.4 mm in NL, had 25 myomeres, and showed rapid growth. By the ninth day after hatching, the larvae had attained 2.9 mm in NL, had an swimbladder in the dorsal margin of ventral region, the preanus length was 37.9% of NL, and their melanophores were enlarged and reduced in number.

  • PDF

Horizontal-Axis Screw Turbine as a Micro Hydropower Energy Source: A Design Feasibility Study (마이크로 수력 에너지원의 수평축 스크류 터빈 : 설계 타당성 연구)

  • SHAMSUDDEEN, MOHAMED MURSHID;KIM, SEUNG-JUN;MA, SANG-BUM;KIM, JIN-HYUK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.1
    • /
    • pp.95-104
    • /
    • 2022
  • Micro hydropower is a readily available renewable energy source that can be harvested utilizing hydrokinetic turbines from shallow water canals, irrigation and industrial channel flows, and run-off river stream flows. These sources generally have low head (<1 m) and low velocity which makes it difficult to harvest energy using conventional turbines. A horizontal-axis screw turbine was designed and numerically tested to extract power from such low-head water sources. The 3-bladed screw-type turbine is placed horizontally perpendicular to the incoming flow, partially submerged in a narrow water channel at no-head condition. The turbine hydraulic performances were studied using Computational Fluid Dynamics models. Turbine design parameters such as the shroud diameter, the hub-to-shroud ratios, and the submerged depths were obtained through a steady-state parametric study. The resulting turbine configuration was then tested by solving the unsteady multiphase free-surface equations mimicking an actual open channel flow scenario. The turbine performance in the shallow channel were studied for various Tip Speed Ratios (TSR). The highest power coefficient was obtained at a TSR of 0.3. The turbine was then scaled-up to test its performance on a real site condition at a head of 0.3 m. The highest power coefficient obtained was 0.18. Several losses were observed in the 3-bladed turbine design and to minimize losses, the number of blades were increased to five. The power coefficient improved by 236% for a 5-bladed screw turbine. The fluid losses were minimized by increasing the blade surface area submerged in water. The turbine performance was increased by 74.4% after dipping the turbine to a bottom wall clearance of 30 cm from 60 cm. The final output of the novel horizontal-axis screw turbine showed a 2.83 kW power output at a power coefficient of 0.63. The turbine is expected to produce 18,744 kWh/year of electricity. The design feasibility test of the turbine showed promising results to harvest energy from small hydropower sources.

Bend-Twist Coupling Behavior of 10 MW Composite Wind Blade (10 MW급 복합재 풍력 블레이드의 굽힘-비틀림 커플링 거동 연구)

  • Kim, Soo-Hyun;Shin, Hyungki;Bang, Hyung-Joon
    • Composites Research
    • /
    • v.29 no.6
    • /
    • pp.369-374
    • /
    • 2016
  • In this study, a structural optimal design of 10 MW composite blade was performed using bend-twist coupled(BTC) design concept. Bend-twist coupling of blade means the coupling behavior between the bending and torsional deflections due to the composite lamina with fiber angle biased from the blade longitudinal axis. This can potentially improve the overall performance of composite blade and reduce the dynamic loading. Parametric studies on layup angle, thickness and area of off-axis carbon UD were conducted to find the optimum coupling effect with weight reduction. Comparing the results of fatigue load analysis between conventional model and BTC applied model, the damage equivalent load(DEL) of blade root area were decreased about 3% in BTC model. To verify the BTC effect experimentally, a 1:29 scaled model was fabricated and the torsion at the tip under deflection behavior of blade stiffener model was measured by static load test.

Development and Verification of Treatment Programs by Turn and Roll Types to Improve the Function of Vestibular System (전정기 기능 향상을 위한 회전과 구르기 훈련 프로그램의 개발 및 검증)

  • Park, Yang-Sun;Kang, Sung-Ho;Lim, Young-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.2
    • /
    • pp.209-217
    • /
    • 2012
  • The purpose of this study was to develop a turn-type treatment program which applies the principle of spotting and a roll-type treatment program that induces off-vertical axis. 29 collegiate students volunteered for this study. 12-week treatment programs were applied to both 15 students for turn-type treatment group and 14 students for roll-type treatment group. As an analytic tool, eye camera was employed to verify the treatment programs for a stimulus upon a turn, recovery after a stimulus upon a turn, and nystagmus that affects a vestibular system. Two-way ANOVA with repeated measures was applied to see the significant differences between the treatment groups, and between the test periods. For Post-Hoc Test, paired t-test was used to within the group and independent t-test was used to between the groups. The results indicated that roll-type treatment training has maximized a stimulus on nystagmyus during the stimulus by a roll. Turn-type treatment training has maximized a stimulus on nystagmyus right after a stimulus by a roll and significantly decreased the intensity of nystagmyus during the recovery. Both turn and roll type treatments have reduced the recovery time which from nystagmyus to a normal status. Roll-type treatment has showed a much shorter recovery time for nystagmyus than the roll-type treatment has. Based on the results of treatment programs developed in this study, we expect the treatment programs can be applied to treat dizziness and to improve the function of vestibular system as a rehabilitation tool.

An Experimental Evaluation of Mechanical Properties and Failure Processing in Composite Laminate (복합재료의 기계적 성질 및 파손과정 평가)

  • J.W.,Ong;K.H.,Song;R.W.,Sung;B.S.,Shim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.25 no.4
    • /
    • pp.58-68
    • /
    • 1988
  • This paper is concerned with mechanical properties of unidirectional laminate $[(0^{\circ})_{8T},\;(90^{\circ})_{8T}]$, composed of angle plies $[({\pm}15^{\circ})_{2S},\;({\pm}30^{\circ})_{2S},\;({\pm}45^{\circ})_{2S},\;({\pm}60^{\circ})_{2S},\;({\pm}75^{\circ})_{2S}$ and laminate $[(9^{\circ}/90^{\circ})_{2S},\;(90^{\circ}/{\pm}45^{\circ}/0^{\circ})_S,\;({\pm}45^{\circ}/0^{\circ}/{\pm}90^{\circ})_S,\;({\pm}45^{\circ}/90^{\circ}/0^{\circ})_S,\;(0^{\circ}/90^{\circ}/{\pm}45^{\circ})_S,\;(90^{\circ}/0^{\circ}/{\pm}45^{\circ})_S]$ under the condition of uniform strain tension. Also, experimental investigation was conducted $[10]_{8T}$, off-axis tensile test for intralaminar shear characterization. The experimental data on the failure criterion of tensor polynomial were compared with those from the classical laminate theory. Acoustic Emission experiments have been carried out to investigate the changes of the amplitude distributions of Acoustic Emission monitored during failure of tensile tests on Carbon/Epoxy composites.

  • PDF