• Title/Summary/Keyword: off line test

Search Result 229, Processing Time 0.029 seconds

Development of Automatic Data Acquisition & Remote Diagnostic System for Improving Efficiency of High-Voltage Motors Off-Line Insulation Diagnostic Test (고압전동기 Off-Line 절연진단시험 효율개선을 위한 데이터자동취득 및 원격진단시스템 구축)

  • Kang, Sang-Mu;Kang, Dae-Jeong;Han, Hyun-Seok;Kim, Won-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.707-708
    • /
    • 2015
  • This paper proposes a method for improving efficiency of high-voltage motors off-line insulation diagnostic test. The conventional manual test method has measurement errors and excessive processing time. We developed the KITAS system and solved these problems by using the instrument remote control and communication technology. The result of proficiency testing by interlaboratory comparisons using Power Factor Tip-Up test was '${\mid}E_n{\mid}$ < 1'. It was possible to confirm the validity of acquired data from the KITAS and establish a remote diagnostic system for easy access without physical limitations.

  • PDF

On-line partial discharge measurement techniques of hydro-generator windings (수력 발전기 권선에서의 운전중 부분방전 측정기법)

  • 황동하;김진봉;김용주;박명수;김택수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.294-300
    • /
    • 1996
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the endwinding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current and .DELTA.tan.delta. tests has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot dischages may not be found with off-line diagnoses. This paper introduces the on-line partial discharge measurement techniques using frequency spectrum analyzer(FSA) for the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF

Cosmetic Store Selection Differences Depending on Make-up Preference Image (화장추구이미지에 따른 화장품 구매점포 선택기준)

  • Lee, Hyun-Jung;Kim, Mi-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.2 s.161
    • /
    • pp.206-216
    • /
    • 2007
  • The purpose of this study was to investigate the differences in the cosmetic purchasing behavior influenced by make-up preference images, and the orders of importance in the cosmetic store selection. The questionnaires were given to female residents in the ages between $20{\sim}45$ in Seoul and Kyung-gi province. 322 questionnaires were used for data analysis. The collected data were analyzed by using SPSS 10.0 software with various techniques such as Frequency analysis, Factor analysis, Cronbach's ${\alpha}$ reliability analysis, Paired t-test, ANOVA test and Duncan test. The results of this study were as follows: 1. After investigating how the make-up preference image influences the selection of the off-line cosmetic store, it was found out that the personal service, shopping convenience, and product composition had significant differences. 2. After investigating how the make-up preference image influences the selection of the on-line cosmetic store, it was found out that only the product composition had significant difference. 3. After studying the factors that influence the off-line cosmetic store selection, it was found that the personal service was considered most important. After studying the factors that influence the on-line cosmetic store selection, it was found that the price was considered most important.

Evaluation of On-Line Partial Discharge Measurement Techniques on Hydro-Generator (수력 발전기의 운전중 부분방전 측정기법에 대한 신뢰성 평가)

  • Hwang, D.H.;Kim, J.B.;Kim, Y.J.;Park, M.S.;Kim, T.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1526-1529
    • /
    • 1994
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the end winding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current test and ${\Delta}tan{\delta}$ test has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot discharges may not be found with off-line diagnoses. This paper describes the on-line partial discharge measurement techniques in the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF

REAL-TIME SIMULATION OF A HIGH SPEED MULTIBODY TRACKED VEHICLE

  • YI K. S.;YI S.-J.
    • International Journal of Automotive Technology
    • /
    • v.6 no.4
    • /
    • pp.351-357
    • /
    • 2005
  • Development of a real-time simulation model for high-speed and multibody tracked vehicles is difficult because they involve hundreds of highly nonlinear equations. In the development of a reliable tracked vehicle model for real-time simulation, it is helpful to use an off-line tracked vehicle model developed by considering all the degrees of freedom of each element. This paper presents a step-by-step procedure for the development of a real-time simulation model based on the off-line tracked vehicle model. The road input data, Profile IV, is used for the real time simulation and simulation results are compared with vehicle test results obtained in the military test field. It is noted that the simulation results are quite close to the test results.

A study on the heat cycle aging of insulation materials in large generator stator windings (대형발전기 고정자권선 절연재료의 열 사이클에 의한 열화에 관한 연구)

  • 김희곤;박영관
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.553-557
    • /
    • 1996
  • Heat cycle aging of insulating materials in large generator stator winding has been investigated using both on-line and off-line test methods. On this study, principally, off-line test against actual generator in service was carried out to acquire information about polarization index(PI) and dissipation factor, dissipation factor tip-up, maximum partial discharge for the purpose of remnant breakdown voltage and life assessment. It was found from the tests that both dissipation factor and maximum partial discharge decreased with the increase of operating hours and starting numbers. It was found from off-line tests that the remnant breakdown voltage had a strong relationship with both dissipation factor and maximum partial discharge the remnant breakdown voltage as a results of both operating hours and starting number and the nondestructive tests were proposed as parameters which can predict the remnant lifetime of insulating materials in large generator stator windings. (author). 8 refs., 8 figs., 2 tabs.

  • PDF

A Research Trend on On-Line/Off-Line PD Insulation Diagnostic System (온라인 및 오프라인 PD 모니터링에 관한 연구 동향)

  • Choo, Jong-Hoon;Hong, Chang-Il;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2008-2009
    • /
    • 2007
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is introduced.

  • PDF

Consumers' Attitude on Textile for Quick Response based Mass-Customization in Marketing Channels (Quick Response 기반의 Moss-Customization 구현을 위한 점포유형에 관한 소비자 태도 연구)

  • 신상무;이효정
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.11
    • /
    • pp.1527-1576
    • /
    • 2002
  • Quick Response based Mass-Customization can be produced and distributed customized goods and services on mass basis in apparel e-business. Because consumers can: t touch and feel the apparel products in e-business, they tend to have the negative buying behavior. The purpose of this study is to investigate the differences of consumer's texture sensibility of apparel products based on marketing channels (on-line/off-line). Two types of questionnaires for on-line and of f-line were used to assess consumer sensibility on apparel fabric. The 8 swatches were selected in regard to the previous literatures. 205 questionnaires for each type (on-line/off-line) were distributed. Statistical devices were t-test, mean and standard deviation with SPSS10.0. The result of this study was showed that there were partially significant differences on consumers' texture sensibility on apparel products between on-line and off-line. Under on-line environment, consumers perceived corduroy as warm, strong, and sandy. taffeta as warm, sandy, and glossy, denim as sandy, and warm, organza as sandy, and thin, satin as sandy, dense, and modern, chiffon as sandy, and flat, velvet as warm, and soft, single jersey as warm, soft, and comfortable. Therefore, apparel firms cooperating based Mass-Customization in e-business have to pay attention to the differences on consumers’ texture sensibility of on-line apparel products from those of off-line.

Off-line Visual Feedback Control of SCARA Robot Using Off Line Programming (오프라인 프로그래밍을 이용한 스카라 로봇의 비쥬얼 피드백제어)

  • 신행봉;이우송;이현철;한성현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.235-240
    • /
    • 2004
  • The equipment of industrial robot in manufacturing and assembly lines has rapidly increased. In order to achieve high productivity and flexibility, it becomes very important to develop the visual feedback control system with Off-Line Programming System(OLPS). We can save much efforts and time in adjusting robots to newly defined workcells by using OLPS. A proposed visual calibration scheme is based on position-based visual feedback. The calibration program firstly generates predicted images of objects in an assumed end-effector position. The process to generate predicted images consists of projection to screen-coordinates, visible range test and construction of simple silhouette figures. Then camera images acquired are compared with predicted ones for updating position and orientation data. Computation of error is very simple because the scheme is based on perspective projection which can be also expanded to experimental results. Computation time can be extremely reduced because the proposed method does not require the precise calculation of tree-dimensional object data and image Jacobian.

  • PDF

The Effect of Hospital Web Service Quality on Initial Trust and Off-line Visit Intention: Focusing on Medium and Small Size Hospital (웹서비스품질이 초기신뢰와 오프라인 방문의도에 미치는 영향: 중소병원을 중심으로)

  • Kim, Sang-Han;Cho, Chul-Ho
    • Journal of Korean Society for Quality Management
    • /
    • v.42 no.3
    • /
    • pp.445-458
    • /
    • 2014
  • Purpose: Present study was designed to examine the casual relationships among web service quality, customer satisfaction, initial trust and off-line visit intention in hospital website. Research object was limited to web service quality of general hospital. We applied path analysis model in order to test the hypotheses and research model. Methods: Survey tool, that is, Questionnaire had obtained validity through literature survey, exploratory survey and pretest and sample 320 was selected. For statistical treatment of pretest and main analysis, SPSS18.0 and AMOS18.0 were employed and Structural equation model was employed as analysis method. Results: Result of this study shows as follows. Factors of web service quality have an effect on customer satisfaction and initial trust, both of customer satisfaction and initial trust have an effect on off-line visit intention. Also customer satisfaction affects initial trust. Especially, customer satisfaction and initial trust were empirically confirmed as the important factors preceding off-line vis it intention. Conclusion: Therefore, present study shows that customer satisfaction and initial trust are important factors that medium and small size hospitals have to emphasize to raise performance. However, present study has some limitations to additionally research in the future.