• Title/Summary/Keyword: observed deviation

Search Result 771, Processing Time 0.029 seconds

Effect of Low Magnetic Field on Dose Distribution in the Partial-Breast Irradiation (부분유방 방사선조사 시 저자기장이 선량분포에 미치는 영향)

  • Kim, Jung-in;Park, So-Yeon;Lee, Yang Hoon;Shin, Kyung Hwan;Wu, Hong-Gyun;Park, Jong Min
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.208-214
    • /
    • 2015
  • The aim of this study is to investigate the effect of low magnetic field on dose distribution in the partial-breast irradiation (PBI). Eleven patients with an invasive early-stage breast carcinoma were treated prospectively with PBI using 38.5 Gy delivered in 10 fractions using the $ViewRay^{(R)}$ system. For each of the treatment plans, dose distribution was calculated with magnetic field and without magnetic field, and the difference between dose and volume for each organ were evaluated. For planning target volume (PTV), the analysis included the point minimum ($D_{min}$), maximum, mean dose ($D_{mean}$) and volume receiving at least 90% ($V_{90%}$), 95% ($V_{95%}$) and 107% ($V_{107%}$) of the prescribed dose, respectively. For organs at risk (OARs), the ipsilateral lung was analyzed with $D_{mean}$ and the volume receiving 20 Gy ($V_{20\;Gy}$), and the contralateral lung was analyzed with only $D_{mean}$. The heart was analyzed with $D_{mean}$, $D_{max}$, and $V_{20\;Gy}$, and both inner and outer shells were analyzed with the point $D_{min}$, $D_{max}$ and $D_{mean}$, respectively. For PTV, the effect of low magnetic field on dose distribution showed a difference of up to 2% for volume change and 4 Gy for dose. In OARs analysis, the significant effect of the magnetic field was not observed. Despite small deviation values, the average difference of mean dose values showed significant difference (p<0.001), but there was no difference of point minimum dose values in both sehll structures. The largest deviation for the average difference of $D_{max}$ in the outer shell structure was $5.0{\pm}10.5Gy$ (p=0.148). The effect of low magnetic field of 0.35 T on dose deposition by a Co-60 beam was not significantly observed within the body for PBI IMRT plans. The dose deposition was only appreciable outside the body, where a dose build-up due to contaminated electrons generated in the treatment head and scattered electrons formed near the body surface.

Study on the Physical Properties of the Gamma Beam-Irradiated Teflon-FEP and PET Film (Teflon-FEP 와 PET Film 의 감마선 조사에 따른 물리적 특성에 관한 연구)

  • 김성훈;김영진;이명자;전하정;이병용
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.11-21
    • /
    • 1998
  • Circular metal electrodes were vacuum-deposited with chromium on the both sides of Teflon-FEP and PET film characteristic of electret and the physical properties of the two polymers were observed during an irradiation by gamma-ray from $\^$60/Co. With the onset of irradiation of output 25.0 cGy/min the induced current increased rapidly for 2 sec, reached a maximum, and subsequently decreased. A steady-state induced current was reached about in 60 second. The dielectric constant and conductivity of Teflon-FEP were changed from 2.15 to 18.0 and from l${\times}$l0$\^$-17/ to 1.57${\times}$10$\^$-13/ $\Omega$-$\^$-1/cm$\^$-1/, respectively. For PET the dielectric constant was changed from 3 to 18.3 and the conductivity from 10$\^$-17/ to 1.65${\times}$10$\^$-13/ $\Omega$-$\^$-1/cm$\^$-1/. The increase of the radiation-induced steady state current I$\^$c/, permittivity $\varepsilon$ and conductivity $\sigma$ with output(4.0 cGy/min, 8.5 cGy/min, 15.6 cGy/min, 19.3 cGy/min) was observed. A series of independent measurements were also performed to evaluate reproducibility and revealed less than 1% deviation in a day and 3% deviation in a long term. Charge and current showed the dependence on the interval between measurements, the smaller the interval was, the bigger the difference between initial reading and next reading was. At least in 20 minutes of next reading reached an initial value. It may indicate that the polymers were exhibiting an electret state for a while. These results can be explained by the internal polarization associated with the production of electron-hole pairs by secondary electrons, the change of conductivity and the equilibrium due to recombination etc. Heating to the sample made the reading value increase in a short time, it may be interpreted that the internal polarization was released due to heating and it contributed the number of charge carriers to increase when the samples was again irradiated. The linearity and reproducibility of the samples with the applied voltage and absorbed dose and a large amount of charge measured per unit volume compared with the other chambers give the feasibility of a radiation detector and make it possible to reduce the volume of a detector.

  • PDF

Comparison of the Outcomes according to the Injury Type of the Short Radiolunate Ligament in Fracture-Dislocation of the Radiocarpal Joint (요수근 관절의 골절-탈구에서 단요월상인대의 손상 형태에 따른 치료 결과의 비교)

  • Heo, Youn Moo;Kim, Tae Gyun;Song, Jae Hwang;Jang, Min Gu;Lee, Seok Won
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.51-60
    • /
    • 2021
  • Purpose: Radiocarpal dislocation (RCD), which is caused by high-energy trauma, often involves radial styloid fractures and short radiolunate ligament (SRLL) injuries. Although SRLL injuries may occur as a simple rupture at the attachment site of radius, it may occur with a relatively large avulsed-fragment in the volar rim of the lunate facet of the radius. This study aimed to differentiate the injury type of SRLL and assess the differences in the treatment results depending on the treatment methods that have been applied in RCD with radial styloid fractures. Materials and Methods: Eighteen patients managed surgically with RCD were enrolled in this study. The patients were classified as Group 1 and Group 2 by using the Dumontier method. In this study, Group 2 was subdivided into 2A (purely ligamentous or small avulsion fracture of the volar rim of lunate facet) and 2B (large avulsed-fragment enough to internal fixation) according to the injury type of SRLL. Groups 2A and 2B were treated with direct repair and screw fixation, respectively. Pain, range of motion of the wrist joint, grip strength, and complications on final radiographs were examined. The outcomes were evaluated using patient-rated wrist evaluation (PRWE), and modified Mayo wrist score (MMWS). Results: All patients were Group 2 (six and twelve patients in 2A and 2B, respectively). The mean flexion to extension arch recovered 79%,and the mean grip strength was 72.9% of the uninjured side. Group 2A showed better recovery in extension, flexion and pronation than Group 2B, but there was no difference in radial deviation, ulnar deviation, supination, grip strength and pain. No differences in the PRWE and MMWS were observed between two groups. Complications included traumatic arthritis in seven patients and residual instability in five patients. Conclusion: When the SRLL was injured, the involvement of a large avulsion fracture on the anterior plane of the radiolunate did not affect the test results. On the other hand, it should be observed cautiously because avulsion fractures tend to disturb the joint's reduction through rotation or displacement. In addition, anatomical reduction and sturdy internal fixation are important for restoring the function of the SRLL.

Effects of Particle Size of Barley on Intestinal Morphology, Growth Performance and Nutrient Digestibility in Pigs

  • Morel, P.C.H.;Cottam, Y.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.11
    • /
    • pp.1738-1745
    • /
    • 2007
  • A growth trial and a digestibility trial were conducted to examine the effect of feed particle size on the performance, nutrient digestibility, gastric ulceration and intestinal morphology in pigs fed barley-based diets. Barley was processed through a hammer mill to achieve four diets varying in particle size (average particle $size{\pm}standard $deviation): coarse ($1,100{\pm}2.19\;{\mu}m$), medium ($785{\pm}2.23\;{\mu}m$), fine ($434{\pm}1.70\;{\mu}m$) and mixed (1/3 of coarse, medium and fine) ($789{\pm}2.45\;{\mu}m$). Sixty-four entire male pigs were used in the growth trial and the diets were fed ad libitum between 31 kg and 87 kg live weight. Following slaughter, stomach and ileal tissues were scored for integrity (ulceration or damage) and histological measurements taken. Twenty-four entire male pigs were used in the digestibility trial, which involved total faecal collection. Over the entire growth phase, there were no differences (p>0.05) in average daily gain and feed conversion ratio between pigs fed diets of different particle size. Pigs fed the coarse and medium diets had lower (p<0.05) stomach ulceration scores (0.20 and 0.25, respectively, on a scale from 0 to 3) than those fed the mixed (0.69) or the fine diets (1.87). The stomachs of all animals fed the fine diet had lesions and stomach ulcerations were present only in this group. Pigs fed the fine diet had thicker (p<0.001) ileal epithelial cell layer with no differences (p>0.05) being observed for villous height or crypt depth. Faecal digestibility coefficients of neutral and acid detergent fibre were the highest (p<0.05) for the mixed diet, intermediate for the fine and coarse diets and the lowest for the medium diet. A similar numerical trend (p = 0.103) was observed for the apparent faecal energy digestibility coefficient. It is concluded that, with barley based diets, a variation in average particle size between $400{\mu}m$ and $1,100{\mu}m$ had no effect on pig performance but the fine dietary particle size affected the integrity of the stomach, as well as the structure of the small intestine, thus compromising overall gut health. Our data also demonstrate that changes in particle size distribution during the digestion process, rather than average particle size or particle size variation, are related to apparent faecal digestibility.

Measurement of Flash Point for Binary Mixtures of 2-Butanol, 2,2,4-Trimethylpentane, Methylcyclohexane, and Toluene at 101.3 kPa (2-Butanol, 2,2,4-Trimethylpentane, Methylcyclohexane 그리고 Toluene 이성분 혼합계에 대한 101.3 kPa에서의 인화점 측정)

  • Hwang, In Chan;In, Se Jin
    • Clean Technology
    • /
    • v.26 no.3
    • /
    • pp.161-167
    • /
    • 2020
  • For the design of the prevention and mitigation measures in process industries involving flammable substances, reliable safety data are required. An important property used to estimate the risk of fire and explosion for a flammable liquid is the flash point. Flammability is an important factor to consider when developing safe methods for storing and handling solids and liquids. In this study, the flash point data were measured for the binary systems {2-butanol + 2,2,4-trimethylpentane}, {2-butanol + methylcyclohexane} and {2-butanol + toluene} at 101.3 kPa. Experiments were performed according to the standard test method (ASTM D 3278) using a Stanhope-Seta closed cup flash point tester. A minimum flash point behavior was observed in the binary systems as in the many cases for the hydrocarbon and alcohol mixture that were observed. The measured flash points were compared with the predicted values calculated via the following activity coefficient (GE) models: Wilson, Non-Random Two-Liquid (NRTL), and UNIversal QUAsiChemical (UNIQUAC) models. The predicted data were only adequate for the data determined by the closed-cup test method and may not be appropriate for the data obtained from the open-cup test method because of its deviation from the vapor liquid equilibrium. The predicted results of this work can be used to design safe petrochemical processes, such as the identification of safe storage conditions for non-ideal solutions containing flammable components.

Quality Control of Observed Temperature Time Series from the Korea Ocean Research Stations: Preliminary Application of Ocean Observation Initiative's Approach and Its Limitation (해양과학기지 시계열 관측 자료 품질관리 시스템 구축: 국제 관측자료 품질관리 방안 수온 관측 자료 시범적용과 문제점)

  • Min, Yongchim;Jeong, Jin-Yong;Jang, Chan Joo;Lee, Jaeik;Jeong, Jongmin;Min, In-Ki;Shim, Jae-Seol;Kim, Yong Sun
    • Ocean and Polar Research
    • /
    • v.42 no.3
    • /
    • pp.195-210
    • /
    • 2020
  • The observed time series from the Korea Ocean Research Stations (KORS) in the Yellow and East China Seas (YECS) have various sources of noise, including bio-fouling on the underwater sensors, intermittent depletion of power, cable leakage, and interference between the sensors' signals. Besides these technical issues, intricate waves associated with background tidal currents tend to result in substantial oscillations in oceanic time series. Such technical and environmental issues require a regionally optimized automatic quality control (QC) procedure. Before the achievement of this ultimate goal, we examined the approach of the Ocean Observatories Initiative (OOI)'s standard QC to investigate whether this procedure is pertinent to the KORS. The OOI QC consists of three categorized tests of global/local range of data, temporal variation including spike and gradient, and sensor-related issues associated with its stuck and drift. These OOI QC algorithms have been applied to the water temperature time series from the Ieodo station, one of the KORS. Obvious outliers are flagged successfully by the global/local range checks and the spike check. Both stuck and drift checks barely detected sensor-related errors, owing to frequent sensor cleaning and maintenance. The gradient check, however, fails to flag the remained outliers that tend to stick together closely, as well as often tend to mark probably good data as wrong data, especially data characterized by considerable fluctuations near the thermocline. These results suggest that the gradient check might not be relevant to observations involving considerable natural fluctuations as well as technical issues. Our study highlights the necessity of a new algorithm such as a standard deviation-based outlier check using multiple moving windows to replace the gradient check and an additional algorithm of an inter-consistency check with a related variable to build a standard QC procedure for the KORS.

Effects of Astragalus membranaceus roots supplementation on growth performance, serum antioxidant and immune response in finishing lambs

  • Hao, Xiaoyan;Wang, Pengju;Ren, Youshe;Liu, Gentang;Zhang, Jianxin;Leury, Brian;Zhang, Chunxiang
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.6
    • /
    • pp.965-972
    • /
    • 2020
  • Objective: Astragalus membranaceus root is a well-known traditional Chinese herbal medicine with many biological active constituents. This study was conducted to examine the effects of Astragalus membranaceus root powder (AMP) on growth performance, serum antioxidant and immune response in finishing lambs. Methods: A total of thirty-six Guangling fat-tailed ram lambs (body weight = 19±2 kg, mean±standard deviation) were randomly assigned to one of six treatments for a 40 d feeding period, with the first 10 d for adaptation. Treatments consisted of the lambs' basal diets with addition of 0, 5, 10, 15, 20, and 30 g/kg of diet of AMP. Results: Response to supplementation level of AMP was quadratic (p≤0.032) for final weight and ADG with the greatest at 10 g/kg of diet, but dry matter intake was not affected (p≥0.227) by treatments. The increase of AMP supplementation resulted in a quadratic response in contents of triglyceride and creatinine (p<0.05), with the lowest values for 10 and 20 g/kg of diet, respectively. A linear and quadratic decrease was observed in activity of alkaline phosphatase in serum of lambs. As the AMP supplementation increased, the activities of total superoxide dismutase and total antioxidant capacity increased linearly (p≤0.018) and hydroxyl radical (OH-) decreased linearly (p = 0.002). For catalase (CAT) and malondialdehyde (MDA), quadratic (p≤0.001) effects were observed among treatments, with the greatest CAT and lowest MDA values at 10 g/kg AMP. Additionally, supplementing AMP up to a level of 10 or 15 g/kg of diet quadratically increased immunoglobulin and interleukin contents in the serum. Conclusion: The results indicated that AMP can be used as natural feed additive in the ration of lambs to improve ADG, antioxidant status, and immune functions, and the optimal dose was 10 g/kg of diet under the condition of this experiment.

Long-Term Follow-Up Study of Young Adults Treated for Unilateral Complete Cleft Lip, Alveolus, and Palate by a Treatment Protocol Including Two-Stage Palatoplasty: Speech Outcomes

  • Kappen, Isabelle Francisca Petronella Maria;Bittermann, Dirk;Janssen, Laura;Bittermann, Gerhard Koendert Pieter;Boonacker, Chantal;Haverkamp, Sarah;de Wilde, Hester;Van Der Heul, Marise;Specken, Tom FJMC;Koole, Ron;Kon, Moshe;Breugem, Corstiaan Cornelis;van der Molen, Aebele Barber Mink
    • Archives of Plastic Surgery
    • /
    • v.44 no.3
    • /
    • pp.202-209
    • /
    • 2017
  • Background No consensus exists on the optimal treatment protocol for orofacial clefts or the optimal timing of cleft palate closure. This study investigated factors influencing speech outcomes after two-stage palate repair in adults with a non-syndromal complete unilateral cleft lip and palate (UCLP). Methods This was a retrospective analysis of adult patients with a UCLP who underwent two-stage palate closure and were treated at our tertiary cleft centre. Patients ${\geq}17$ years of age were invited for a final speech assessment. Their medical history was obtained from their medical files, and speech outcomes were assessed by a speech pathologist during the follow-up consultation. Results Forty-eight patients were included in the analysis, with a mean age of 21 years (standard deviation, 3.4 years). Their mean age at the time of hard and soft palate closure was 3 years and 8.0 months, respectively. In 40% of the patients, a pharyngoplasty was performed. On a 5-point intelligibility scale, 84.4% received a score of 1 or 2; meaning that their speech was intelligible. We observed a significant correlation between intelligibility scores and the incidence of articulation errors (P<0.001). In total, 36% showed mild to moderate hypernasality during the speech assessment, and 11%-17% of the patients exhibited increased nasalance scores, assessed through nasometry. Conclusions The present study describes long-term speech outcomes after two-stage palatoplasty with hard palate closure at a mean age of 3 years old. We observed moderate long-term intelligibility scores, a relatively high incidence of persistent hypernasality, and a high pharyngoplasty incidence.

Relationship between the DNA content of human chromosome and their contribution to radiation-induced chromosome aberration analysed by fluorescence in situ hybridization(FISH) (방사선에 의한 염색체이상과 DNA 함량과의 관계)

  • Chung, Hai-Won;Kim, Su-Young;Ha, Sung-Whan;Kim, Tae-Hwan;Cho, Chul-Koo
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.2
    • /
    • pp.101-111
    • /
    • 2001
  • To study the relationship between the DNA content of human chromosomes and their involvement in radiation-induced structural chromosome aberrations, the frequencies of translocations and dicentrics induced in human lymphocytes after in vitro exposure to 2Gy of x-tay were analysed by fluorescence in situ hybridization(FISH). Single whole chromosome probes(WCP), specific for chromosomes 1, 2, 4, 7, 8, 9, and 21 and triple combination of probes tot chromosome 1, 2 & 4 were used separately. A significant deviation of the frequency of symmetrical translocation and dicentrics from a DNA-proportional distribution was observed. Chromosomes 2, 7, 8, 9 and 21 were less frequently involved in the formation of symmetrical translocations and dicentrics than expected, whereas chromosomes 1 and 4 were more frequently involved. Chromosome 2 and 4 showed a higher frequency of acentric fragments. When triple combination probe for chromosome 1, 2 & 4 was used, no differences were found between the observed and expected frequency of exchange type aberrations. The results showed that the frequency of radiation-induced chromosome aberrations was not proportional to DNA contents, suggesting the difference in the susceptibility to specific aberrations among individual chromosomes. The results also indicated that the FISH technique with combination of probes for chromosome 1, 2 & 4 was useful for radiation biodosimetry.

  • PDF

Development of Method for Determining 4-Hydroxy-L-isoleucine in Health Functional Foods by HPLC (건강기능식품에서 HPLC를 이용한 4-Hydroxy-L-isoleucine 분석법 연구)

  • Lee, Se-Yun;Jeong, Hee-Sun;Hu, Soo-Jung;Lee, Hye-Young;Oh, Jae-Myoung
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.3
    • /
    • pp.213-218
    • /
    • 2020
  • This study was conducted to develop a method of analysis for 4-hydroxy-L-isoleucine in the seed extract of fenugreek (Trigonella foenum graecum), a health functional food that contains dietary fiber. The analytical method for 4-hydroxy-L-isoleucine was derived with O-phthaldialdehyde reagent (OPA) and determined by HPLC-PDA. The method was performed on a Capcell Pak C18 UG 120 column (4.6×250 mm, 5 ㎛) in isocratic elution mode using disodium phosphate and acetonitrile. The validation of the developed analytical method was conducted by evaluating several parameters; selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy and repeatability. Excellent linearity (R2=0.999) was observed for 4-hydroxy-L-isoleucine in the concentration range (5-100 ㎍/mL). Observed recoveries of these compounds were found to be between 91.7 and 96.4%. Precision was between 0.2 and 2.4% relative standard deviation (%RSD).