• 제목/요약/키워드: oblique

검색결과 1,719건 처리시간 0.034초

Orthopantomogram과 $45^{\circ}$ 측모두부 방사선 사진과의 구치부 치근평행도의 신뢰도에 관한 비교연구 (A COMPARATIVE STUDY ON RELIABILITY OF THE ROOT PARALLELISM OF THE POSTERIOR TEETH PROJECTED ON THE ORTHOPANTOMOGRAM WITH THE $45^{\circ}$ OBLIQUE CEPHALOGRAM)

  • 민영규;유영규
    • 대한치과교정학회지
    • /
    • 제23권3호
    • /
    • pp.359-374
    • /
    • 1993
  • At present, many orthodontists regard the root parallelism of the posterior teeth important not only in diagnosis and treatment planning but also for predicting posttreatment stability. To evaluate it, they usually refer to the orthopantomogram. At this study, 97 samples were collected from students of Yonsei University, who have well-proportioned face, Angle's class I canine & molar relationships and no crown axis deviation of the posterior teeth including canines. Reliability of the root parallelism observed from orthopantomogram was evaluated by comparison with $45^{\circ}$ oblique cephalogram. The results were as follows : 1. In comparing the differences between anglular measurements in $45^{\circ}$ oblique cephalogram & orthopantomogram with $5^{\circ}$, those to mandibular plane were significantly less than to occlusal plane in number of items which showed less differences than $5^{\circ}$. 2. Compared the root parallelisms in the orthopantomogram with those in $45^{\circ}$ oblique cephalogram with $1\%$ significance level, parallelism between upper canine & 1st premolar, lower canine & 1st premolar, lower 1st premolar & 2nd premolar, and lower right 2nd molar & 3rd molar showed statistically significant differences. 3. When the significance between the differences of the root parallelism between above two kinds of film and $5^{\circ}$ was verified by two sided paired t-test, more or less large difference was shown between lower right 2nd molar & 3rd molar, a little larger than $5^{\circ}$ between lower canine & 1st premolar, smaller at the rest of them. 4. In $45^{\circ}$ oblique cephalogram, lower canine & 1st premolar showed convergent root arrangements each other, while in orthopantomogram they were divergent each other. All the others except them showed convergency on the upper, divergency on the lower in both films.

  • PDF

나선빗인대 재건을 이용한 원위지관절 신전장애의 교정 (Correction of Distal Interphalangeal Joint Extension Lag Using Spiral Oblique Retinacular Ligament Reconstruction)

  • 문경환;김진수;이동철;기세휘;노시영;양재원
    • Archives of Plastic Surgery
    • /
    • 제33권4호
    • /
    • pp.480-484
    • /
    • 2006
  • Purpose: A lot of surgical techniques were tried to correct extension lag of distal interphalangeal joint. Spiral oblique retinacular ligament reconstruction is the one of correction techniques. Methods: From January 2004 to January 2005, a total of 13 extension lag of distal interphalangeal joint corrections were performed using spiral oblique retinacular ligament reconstruction for 11 patients. After dorsal incision exposing from base of distal phalanx to proximal phalanx, the new ligament(half of lateral band or graft tendon) lies distally at the dorsum of the distal phalanx and passes volarly and proximally along the side of the middle phalanx and anterior and obliquely across the front of the proximal interphalangeal joint to the opposite side of the digit at the proximal phalanx. Results: 5 of 6 mallet finger deformities and 7 swan neck deformities were corrected, which were both extension lag of distal interphalangeal joint and hyperextension of proximal interphalangeal joint. Conclusion: As a result, spiral oblique retinacular ligament reconstruction is an effective and recommendable method for correction of mallet finger deformity and swan neck deformity.

항공용 다각사진 카메라 시스템의 플랫폼 캘리브레이션 (Platform Calibration of an Aerial Multi-View Camera System)

  • 이창노;김창재;서상일
    • 한국측량학회지
    • /
    • 제28권3호
    • /
    • pp.369-375
    • /
    • 2010
  • 다각사진은 3차원 공간정보의 시각화 뿐 아니라 측정 목적으로도 사용되므로 카메라 시스템에 대한 캘리브레이션이 요구된다. 다각사진 카메라 시스템을 구성하는 각 카메라는 홀더에 장착되어 상대적인 자세 및 위치가 고정된다. 따라서 투영중심점 위치와 자세각은 중앙에 장착된 연직사진에 대해서 적용하고 나머지 4 대의 경사사진용 카메라에 대한 투영중심점 위치 및 자세각은 연직사진에 대한 상대적인 값으로부터 계산될 수 있다. 이에 본 연구에서는 다각사진 카메라 시스템에 의해 실제 촬영된 다각사진을 이용하여 항공삼각측량을 실시 한 후 얻어진 다각사진의 외부표정요소로부터 연직사진을 기준으로 경사사진의 상대적 자세각과 투영중심점의 상대적 위치에 대해 조사 분석하였다. 연구결과 연직사진에 대한 경사사진의 투영중심점 위치는 표준편차가 크게 나타났으며 자세각에 대해서는 경사방향에 관계없이 연직사진을 고정하고 경사사진만 조정할 때 그 표준편차가 더 작게 나타났다. 또한 전체 외부표정요소를 구할 경우보다 자세각만 구할 경우 전반적으로 표준편차가 작으며 안정적인 것을 알 수 있었다.

SUS316L 강의 초음파 비선형 특성평가를 위한 경사입사기법 (Oblique Incidence Technique for Ultrasonic Nonlinear Characterization in SUS316L Alloy)

  • 백승현;이태훈;김정석;장경영
    • 비파괴검사학회지
    • /
    • 제30권4호
    • /
    • pp.345-351
    • /
    • 2010
  • 본 연구에서는 고주기 피로를 받은 SUS316L 강에서의 초음파 비선형 특성평가를 위한 종파 경사입사기법을 연구하였다. Dog-bone형의 판상시편을 준비하여 시편 중심부에서 응력집중이 되며 각 위치마다 피로 손상이 다르도록 제작하였다. 수직투과법 외에 본 연구에서 새로이 제안한 경사입사법을 이용하여 초음파 비선형 파라미터를 측정하였다. 두 기법 모두에서 피로 손상 전보다 고주기 피로 손상 후 초음파 비선형 파라미터가 높게 나타났다. 특히, 응력 집중을 받은 시편 중심부에서 크게 증가하였다. 상대적인 초음파 비선형 파라미터는 피로 손상과 밀접한 상관성을 보였으며 결과적으로 종파를 이용한 경사입사기법은 피로 손상을 평가하는데 효과적인 기법이라 할 수 있다.

Finite Element Stress Analysis according to Apical-coronal Implant Position

  • Kang, Tae-Ho;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제32권1호
    • /
    • pp.52-59
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate the influence of apical-coronal implant position on the stress distribution after occlusal and oblique loading. Materials and Methods: The cortical and cancellous bone was assumed to be isotropic, homogeneous, and linearly elastic. The implant was apposed to cortical bone in the crestal region and to cancellous bone for the remainder of the implant-bone interface. The cancellous core was surrounded by 2-mm-thick cortical bone. An axial load of 200 N was assumed and a 200-N oblique load was applied at a buccal inclination of 30 degrees to the center of the pontic and buccal cusps. The 3-D geometry modeled in Iron CAD was interfaced with ANSYS. Results: When only the stress in the bone was compared, the minimal principal stress at load Points A and B, with a axial load applied at 90 degrees or an oblique load applied at 30 degrees, for model 5. The von Mises stress in the screw of model 5 was minimal at Points A and B, for 90- and 30-degree loads. When the von Mises stress of the abutment screw was compared at Points A and B, and a 30-degree oblique load, the maximum principal stress was seen with model 2, while the minimum principal stress was with model 5. In the case of implant, the model that received maximum von Mises stress was model 1 with the load Point A and Point B, axial load applied in 90-degree, and oblique load applied in 30-degree. Discussion and Conclusions: These results suggests that implantation should be done at the supracrestal level only when necessary, since it results in higher stress than when implantation is done at or below the alveolar bone level. Within the limited this study, we recommend the use of supracrestal apical-coronal positioning in the case of clinical indications.

전신 기울기 운동 시 시각적 바이오피드백이 올바른 자세 유지 시간과 체간 근육의 근활성도에 미치는 영향 (The Effect of Visual Biofeedback on EMG Activity of Trunk Muscles and Endurance Holding Time for Correct Position During Whole-Body Tilt Exercise)

  • 강민혁;윤지연;양재락;장준혁;정도헌;오재섭
    • 한국전문물리치료학회지
    • /
    • 제18권1호
    • /
    • pp.9-17
    • /
    • 2011
  • The purpose of this study was to assess visual biofeedback's influence on trunk muscles' (EMG) activity and endurance holding time for correct position during whole-body tilt exercise. For the study, we recruited 14 volunteers who showed no symptom of lumbar disease during medical tests. We measured the EMG activity of their rectus abdominis, external abdominal oblique, internal abdominal oblique and erector spinae muscles, and their endurance holding time for correct position during $40^{\circ}$ anterior and posterior whole-body tilt under two conditions: whole-body tilt with and without visual biofeedback. Resistance with gravitational force on the trunk during whole-body tilt was applied by using a device that had a monitor on which the subjects could check their alignment and that sounded an alarm if a subject's alignment collapsed. The study showed an increase in the EMG activity of external abdominal oblique, internal abdominal oblique/rectus abdominis ratio and endurance holding time for correct position during both $40^{\circ}$ anterior and posterior whole-body tilt with visual biofeedback compared with without visual biofeedback (p<.05). We suggest that the whole-body tilt exercise with visual biofeedback could be a beneficial strategy for selectively strengthening the internal abdominal oblique muscle and minimizing the rectus abdominis muscle's activity while maintaining correct alignment during whole-body tilt exercise.

경사충돌 피닝잔류응력에 미치는 해석인자의 영향 및 소성숏이 포함된 3차원 유한요소모델 (3D FE Model with FEA Factors and Plastic Shots for Residual Stress Under Oblique Shot Peening)

  • 이배화;김태형;이형일
    • 대한기계학회논문집A
    • /
    • 제34권3호
    • /
    • pp.323-331
    • /
    • 2010
  • 본 연구에서는 경사충돌시 피닝잔류응력 평가를 위해 3 차원 유한요소해석모델을 제안한다. 단일경사 충돌 해석모델을 이용해 Rayleigh 재료감쇠, 동적마찰 그리고 재료의 변형률 속도에 대한 영향을 알아 보고 이를 통합하여 피닝잔류응력 유일해를 얻는다. 숏볼은 변형을 고려한 소성숏을 포함한 해석 모델이며, 다중숏 경사충돌해석으로 확장한다. 다중경사충돌 해석모델은 단일경사충돌 연구를 통해 결정된 통합된 피닝인자들을 반영했고, 숏볼은 소성숏을 사용하였다. XRD 실험해와 비교시, 강체 및 탄성숏 해석모델에서 얻어진 해석해에 비해 소성숏 모델의 해석해가 실험해에 매우 근접하다. 이로부터 다양한 투사각을 갖는 3 차원 유한요소해석모델의 유효성을 확인하였다. 궁극적으로 제안된 해석모델은 실제 피닝현상을 충분히 반영하기 위한 다중숏 경사충돌해석연구의 초석이 될 것이다.

초고층건물의 사각조망에서 촬영된 지붕표면 열화상의 신뢰도 평가 (Evaluating Reliability of Rooftop Thermal Infrared Image Acquired at Oblique Vantage Point of Super High-rise Building)

  • 류택형;엄정섭
    • 한국태양에너지학회 논문집
    • /
    • 제33권5호
    • /
    • pp.51-59
    • /
    • 2013
  • It is usual to evaluate the performance of the cool roof by measuring in-site rooftop temperature using thermal infra-red camera. The principal advantage of rooftop thermal infrared image acquired in oblique vantage point of super high-rise building as a remote sensor is to provide, in a cost-effective manner, area-wide information required for a scattered rooftop target with different colors, utilizing wide view angle and multi-temporal data coverage. This research idea was formulated by incorporating the concept of traditional remote sensing into rooftop temperature monitoring. Correlations between infrared image of super high-rise building and in-situ data were investigated to compare rooftop surface temperature for a total of four different rooftop locations. The results of the correlations analyses indicate that the rooftop surface temperature by the infrared images of super high-rise building alone could be explained yielding $R^2$ values of 0.951. The visible permanent record of the oblique thermal infra-red image was quite useful in better understanding the nature and extent of rooftop color that occurs in sampling points. This thermal infrared image acquired in oblique vantage point of super high-rise made it possible to identify area wide patterns of rooftop temperature change subject to many different colors, which cannot be acquired by traditional in-site field sampling. The infrared image of super high-rise building breaks down the usual concept of field sampling established as a conventional cool roof performance evaluation technique.

내부연결방식 임플랜트 시스템의 삼차원 유한요소법적 연구 (THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF INTERNALLY CONNECTED IMPLANT SYSTEMS)

  • 김유리;조혜원;이재봉
    • 대한치과보철학회지
    • /
    • 제44권1호
    • /
    • pp.85-102
    • /
    • 2006
  • Statement of problem: Currently, there are some 20 different geometric variations in implant/abutment interface available. The geometry is important because it is one of the primary determinants of joint strength, joint stability, locational and rotational stability. Purpose: As the effects of the various implant-abutment connections and the prosthesis height variation on stress distribution are not yet examined this study is to focus on the different types of implant-abutment connection and the prosthesis height using three dimensional finite element analysis. Material and method. The models were constructed with ITI, 3i TG, Bicon, Frialit-2 fixtures and solid abutment, TG post, Bicon post, EstheticBase abutment respectively. And the super structures were constructed as mandibular second premolar shapes with 8.5 mm, 11 mm, 13.5 mm of crown height. In each model, 244 N of vertical load and 244 N of $30^{\circ}$ oblique load were placed on the central pit of an occlusal surface. von Mises stresses were recorded and compared in the crowns, abutments, fixtures. Results: 1. Under the oblique loading, von Mises stresses were larger in the crown, abutment, fixture compared to the vertical loading condition. 2. The stresses were increased proportionally to the crown height under oblique loading but showed little differences with three different crown heights under vertical loading. 3. In the crown, the highest stress areas were loading points under vertical loading, and the finish lines under oblique loading. 4. Under the oblique loading, the higher stresses were located in the fixture/abutment interface of the Bicon and Frialit-2 systems compared to the ITI and TG systems. Conclusions: The stress distribution patterns of each implant-abutment system had difference among them and adequate crown height/implant ratio was important to reduce the stresses around the implants.

빗각 증착으로 제조한 Al 박막의 특성 (Characteristics of Al Films Prepared by Oblique Angle Deposition)

  • 박혜선;양지훈;정재훈;송민아;정재인
    • 한국표면공학회지
    • /
    • 제45권3호
    • /
    • pp.111-116
    • /
    • 2012
  • Oblique angle deposition (OAD) is a physical vapor deposition method which utilizes non-normal angles between the substrate and the vaporizing source. It has been known that tilting the substrate changes the properties of the film deposited on it, which was thought to be a result of morphological change of the film. In this study, OAD has been applied to prepare single and multilayer Al films by magnetron sputtering. The magnetron sputtering source of 4 inch diameter was used to deposit the films. Al films have been deposited on Si wafers and cold-rolled steel sheets. The multilayer films were prepared by changing the tilting angle upside down at each layer interval, which means that when the first layer was deposited at an angle of $+45^{\circ}$, the second layer was deposited at an angle of $-45^{\circ}$, and vice versa. The microstructure, surface roughness and reflectance of the films were investigated using a scanning electron microscope, a surface profiler and a spectrophotometer, respectively. The corrosion resistance was measured and compared using the salt spray test. The single layer film prepared at an oblique angle of $60^{\circ}$ prepared at other angles. However, for the multilayer films, the film prepared at an oblique angle of $45^{\circ}$ showed the most compact and featureless structure. The multilayer films were found to exhibit higher corrosion resistance than the single layer films.