• 제목/요약/키워드: numerical analysis model

검색결과 7,876건 처리시간 0.03초

환기용 축류송풍기의 유동해석 및 모터 위치에 따른 성능 특성 연구 (Flow Analysis and Performance Evaluation of a Ventilation Axial-Flow Fan Depending on the Position of Motor)

  • 김재우;김진혁;김광용
    • 한국유체기계학회 논문집
    • /
    • 제13권4호
    • /
    • pp.25-30
    • /
    • 2010
  • Flow analysis and performa nce evaluation have been performed for a ventilation axial-flow fan with different positions of the motor. Two different positions of motor have been tested; one is in front of the impeller and the other is behind the impeller. Flow analyses are performed by solving three-dimensional Reynolds-averaged Navier-Stokes equations through a finite-volume solver. Preliminary numerical calculations are carried out to test the performances of different turbulence models, i.e., SST model, k-$\omega$ model, and k-$\varepsilon$ model with and without using empirical wall function in the flow analysis. The validation of numerical analyses has been performed in comparison with the experimental data. The numerical results for the performance characteristics of the ventilation axial-flow fan with two different positions of the motor have been presented.

수치 모델에 따른 압전 구동방식 마이크로 펌프의 유동특성에 관한 연구 (A Study on the Flow Characteristics of Piezoelectric Micropumps with Different Numerical Models)

  • 정진;김동희;김창녕
    • 설비공학논문집
    • /
    • 제16권8호
    • /
    • pp.707-713
    • /
    • 2004
  • A numerical analysis has been conducted for flow characteristics of piezoelectric micropumps. In the present study, FSI (Fluid-Structure Interaction) model and grid deform model have been employed for each of two different geometries of the micropumps with two different frequencies in the piezoelectric diffuser/nozzle based micropumps. The displacement of piezo disk and flow rates have been closely examined at the inlet and outlet. It has been found that the motion of the piezo disk investigated with FSI model is not in accordance with that with grid deform model. The results show that the time averaged flow rate calculated with FSI model is larger than that with grid deform model. This study presents the performance analysis of piezoelectric micropumps with two different numerical models for different types of pumps.

지반굴착 해석모델에 따른 변위거동에 관한 연구 (A Study on the Displacement Behavior according to the Analysis Model of Ground Excavation)

  • 정지승;신영완;김만화;국윤모;정규경;김필수;이상환
    • 한국지반환경공학회 논문집
    • /
    • 제19권4호
    • /
    • pp.27-32
    • /
    • 2018
  • 제한된 토지의 효율적인 활용을 위해 과거로부터 지하공간 개발에 따라 수많은 지반굴착 공사가 이루어져 왔다. 지반굴착은 굴착면 주변지반의 응력변화와 변위를 수반함에 따라 굴착면의 안정성에 영향을 미치게 되어 지반거동에 대한 영향을 예측하는 것이 매우 중요한 문제이다. 이러한 영향 예측을 위한 방법으로 수치해석방법이 주로 이용되며, 최근 컴퓨터 성능 향상과 더불어 수치해석 프로그램의 발달로 매우 복잡한 문제도 적용이 가능해졌다. 그러나 일부 특수해석을 제외하고 대부분 해석모델을 산정 및 적용이 간편한 Mohr-Coulomb 해석모델을 적용함에 따라 굴착면 바닥부에서 실제보다 큰 변위가 발생하는 것으로 예측되어 필요 이상의 보강이 이루어지는 문제점이 발생한다. 본 연구에서는 지반굴착 과정을 모사하여 수치해석을 수행하였으며, 해석모델로 Mohr-Coulomb, Modified Mohr-Coulomb, Duncan-Chang, Hardening Soil 해석모델을 적용하여 그 결과를 비교분석하였다. 본 연구는 수치해석을 통한 지반굴착 문제해결 시 다양한 지반굴착 조건별로 적합한 해석모델 선정을 위한 기초자료로 활용될 것으로 기대된다.

INVESTIGATION OF THE PILE MOVEMENT DUE TO TUNNELLING BY MODEL TEST AND NUMERICAL ANALYSIS

  • Lee, Yong-Joo
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회 3차
    • /
    • pp.104-110
    • /
    • 2010
  • In this study, a series of two-dimensional model test and numerical analysis was carried out to investigate the pile movement due to tunnelling in soft ground. The model test consists of 21 cases according to locations of the pile tip over the centre position of model tunnel. To identify both the pile and ground movements a close-range photogrammetric technique was adopted in the model test. The results from the model test were compared to the two-dimensional finite element analysis using the CRISP program. It was found that the rotation point on the pile was significantly affected by factors such as the offset distance from the model tunnel and the volume loss that occurred during the tunnelling operation.

  • PDF

Turbo Fan 형상에 따른 맥동압력에 관한 수치해석 (A Numerical Analysis on Pressure Pulsation with Turbo Fan Shape)

  • 이중섭;서정세;송철기;홍정규;신유인
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1355-1360
    • /
    • 2009
  • This study simulates the flow characteristics of the turbo-fan which was applied to the industrial scale. Numerical analysis has been carried out to investigate a pulsation behavior of exhaust air that flow out the turbo fan, considering a constant rotating rate of impeller. Moving mesh technique provides time-accurate solutions for the flow inside an impeller. From the numerical results, FFT analysis has been made for pressure pulsations inside turbo-fan casing. The numerical simulation shows the pulsation of model-2 has higher than model. Additionally, BPF value is almost same as the numerical results.

  • PDF

스크린도어가 설치된 지하철에서 열차운행에 의한 비정상유동의 실험 및 수치적 해석 (Experimental and Numerical Analyses of Unsteady Tunnel Flow in Subway Equiped with Platform Screen Door System)

  • 김정엽;김광용
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.103-111
    • /
    • 2006
  • To optimize the ventilation and smoke control systems in subway equipped with platform screen door, the technology to analyze the unsteady tunnel flow caused by running of train should be developed. The development of model experiment and numerical analysis technique with relation to unsteady flow of subway were presented. The pressure and air velocity changes in 1/20-scaling experiment unit were measured and results were comparied to those of 3-D unsteady numerical analysis applied with sharp interface method. The experimental and numerical results were quantitatively similar and it would be reasonable to apply sharp interface method to analyze the unsteady flow in subway equipped with platform screen door.

삼차원 점성 효과를 고려한 축류 압축기의 성능에 대한 수치해석 (Numerical Analysis for the Performance of an Axial-flow Compressor with Three-Dimensional Viscous Effect)

  • 한용진;김광용;고성호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 추계 학술대회논문집
    • /
    • pp.182-187
    • /
    • 2003
  • Numerical analysis of three-dimensional vicous flow is used to compute the design speed operating line of a transonic axial-flow compressor. The Navier-Stokes equation was solved by an explicit finite-difference numerical scheme and the Baldwin-Lomax turbulence model was applied. A spatially-varying time-step and an implicit residual smoothing were used to improve convergence. Two-stage axial compressor of a turboshaft engine developed KARI was chosen for the analysis. Numerical results show reasonably good agreements with experimental measurements made by KARI. Numerical solutions indicate that there exist a strong shock-boundary layer interaction and a subsequent large flow separation. It is also observed that the shock is moved ahead of the blade passage at near-stall condition.

  • PDF

비내진 설계된 RC 골조에 대한 전단강도 감소 효과를 고려한 수치해석의 비교 (Comparisons of Numerical Analyses considering the Effects of Shear Strength Degradation For Nonseismic Designed RC Frame)

  • 이영욱
    • 한국지진공학회논문집
    • /
    • 제10권1호
    • /
    • pp.1-8
    • /
    • 2006
  • 비내진 설계된 철근콘크리트 골조는 내진상세의 미확보로 인하여 전단파괴의 가능성이 있다. 이러한 전단파괴를 해석 모델링에 반영하기 위하여 Moehle과 ATC 40을 포함한 4개의 전단강도감소 모델을 선택하고 비교하였으며, 각 모델을 예제 건물에 적용하여 Push-over해석을 수행하였다. 해석용 예제 모델은 3층 규모로 하였으며 국내 콘크리트 설계기준에 따라 설계하였다. 전단강도 감소모델 비교 결과, Moehle의 모델은 NZSEE의 모델보다 전단내력을 작게 평가하고 ATC 40 모델에 비하여 휨 연성도에 따른 내력의 변동이 작으며, 대부분의 경우에 고찰된 모델들의 전단내력은 ACI 318의 공칭 전단강도보다 크게 나타남을 알 수 있었다. 예제 모델의 수치해석 비교 결과, 전단강도 감소모델에 따라 건물의 수평 저항 능력에 큰 차이가 나타나며, 전단스프링에 전단강도 감소를 고려한 모델에 비하여 ATC 40의 횡 소성 변형을 제한하는 모델을 사용하면 횡저항 능력을 과소평가하게 됨을 알 수 있었다.

A multiscale numerical simulation approach for chloride diffusion and rebar corrosion with compensation model

  • Tu, Xi;Li, Zhengliang;Chen, Airong;Pan, Zichao
    • Computers and Concrete
    • /
    • 제21권4호
    • /
    • pp.471-484
    • /
    • 2018
  • Refined analysis depicting mass transportation and physicochemical reaction and reasonable computing load with acceptable DOFs are the two major challenges of numerical simulation for concrete durability. Mesoscopic numerical simulation for chloride diffusion considering binder, aggregate and interfacial transition zone is unable to be expended to the full structure due to huge number of DOFs. In this paper, a multiscale approach of combining both mesoscopic model including full-graded aggregate and equivalent macroscopic model was introduced. An equivalent conversion of chloride content at the Interfacial Transition Layer (ITL) connecting both models was considered. Feasibility and relative error were discussed by analytical deduction and numerical simulation. Case study clearly showed that larger analysis model in multiscale model expanded the diffusion space of chloride ion and decreased chloride content in front of rebar. Difference for single-scale simulation and multiscale approach was observed. Finally, this paper addressed some worth-noting conclusions about the chloride distribution and rebar corrosion regarding the configuration of rebar placement, rebar diameter, concrete cover and exposure period.

금속의 펨토초 어블레이션의 수치해석 (Numerical analysis of fs laser ablation of metals)

  • 오부국;김동식;김재구;이제훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.657-658
    • /
    • 2006
  • Although there are many numerical models to simulate fs laser ablation of metals, no model can analyze the ablation phenomena over a wide range of fluence. In this work, a numerical code for simulating the fs laser ablation phenomena of metals has been developed. The two temperature model is employed to predict the ablation rate and the crater shape of metals using phase explosion mechanism in the relatively high fluence regime. Also, the ultrashort thermoelastic model is used for the low fluence regime to account for spallation of the sample by high strain rate. It has been demonstrated that the thermoelastic stress generated within the sample can exceed the yield stress of the material even near the threshold fluence. Numerical computation results are compared with the experiment for Cu and Ni and show good agreement. Discussions are made on the hydrodynamic model considering phase change and hydrodynamic flow.

  • PDF