• 제목/요약/키워드: nuclear magnetic resonance imaging

검색결과 123건 처리시간 0.025초

엄지 두덩 덩이로 발생한 근육내 신경섬유종 (An Intramuscular Neurofibroma Presenting as a Thenar Mass)

  • 강문석;최환준;남승민;이형교
    • Archives of Plastic Surgery
    • /
    • 제38권1호
    • /
    • pp.109-112
    • /
    • 2011
  • Purpose: Neurofibromas may present as multiple or solitary lesions. Although there is no predilection site for solitary lesions, they are rare on the hand. In addition, solitary intramuscular neurofibromas are a very rare pathological type. Here, we report a rare solitary intramuscular neurofibroma in the hand. This paper examines the clinical characteristics of intramuscular neurofibroma arising from the lumbricalis in order to enable a correct diagnosis and treatment. Methods: A 32-year-old male presented with a painless mass on the palm. The physical examination revealed a $3{\times}2$ cm protruding mass that was non-tender to palpation. The vascular and sensory examinations were unremarkable, while the motor examination showed mild difficulty with flexion and extension. Magnetic resonance imaging demonstrated an enhancing solid mass between the thenar eminence and second metacarpophalangeal joint. The diagnosis of an intramuscular neurofibroma was confirmed following surgical excision and histological evaluation. Results: The pathological examination was consistent with a neurofibroma, with delicate fascicles and loose fusiform cells in a fibrous stroma, with oval or spindle-shaped nuclei and scant cytoplasm. The background matrix was pale staining and had focal myxoid stroma. There was no significant nuclear pleomorphism and no mitoses. Immunohistochemistry with S-100 was slightly positive. At the 6-month follow-up, motor and sensory function were intact and the range of motion was full. Conclusion: A neurofibroma is a rare tumor of the hand, especially the intramuscular type. Hand surgeons should consider the diagnosis of this tumor based on the examination and imaging.

전문방사선사 제도의 개발에 관한 연구 (A Study on System Model of Clinical Specialist in Radiologic Technology)

  • 최종학;김유현;강희두;오문규;김병도;한승희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권1호
    • /
    • pp.63-76
    • /
    • 2000
  • License system of radiologic technologists has been started since 1965 in Korea. This study is to explore directions on radiotechnologists' license system classified by subspecialty. For this purpose, the authors surveyed on radiotechnologists' license system classified by subspecialty, with the subject related to radiotechnologic societies. Additionally, data on qualification and license system associated with medical and health care field were collected. The results are as follows. 1. The main body for subspecialty system for radiologic technologists should be the Korea Radiologic Technologists Association and the Association should maintain a close cooperation with radiotechnologic societies. 2. A radiologic technologist should be a basic role once they pass the license examination. In addition, they can get a special qualification by subspecialty in radiologic technology. 3. Radiotechnologists' license system classified by subspecialty will be keep priorities in order and done systematically. Execution order is as follows ; This study proposes that radiotechnologists responsible for ultrasonography, computed tomography(CT), magnetic resonance imaging(MRI) and security management be started for the first stage. For the second stage, radiotechnologists for mammography, angio-cardiography, digital imaging, maxillo-facial and dental radiography, nuclear medicine, radio-therapeutic field should be in force. 4. Professional education course(basic and intensive) and clinical training program have to be made for the eligibility of radiotechnologists' license system classified by subspecialty. 5. Eligibility system of radiotechnologists' license system classified by subspecialty(non-government or government) has to be made. Further more, inquiry commission to investigate eligibility for radiotechnologists' license system should be established.

  • PDF

방사선사 국가시험 준비를 위한 대학생들의 과목별 중요도와 이해도 수준 및 요구도 분석 (Analysis of Importance, Understanding Level and Needs by Subject of College Students Preparing for Radiological Technologists National Examination)

  • 김영록;정재홍;김대건
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권1호
    • /
    • pp.53-61
    • /
    • 2023
  • The aim of this study analyzed the important level (IL) and understanding level (UL) including the Borich's need for students preparing of the national examination for radiological technologists at online open chatting room. A total of 254 survey were collected from a total of 1,016 students who used open chatting room from December 13 to December 16, 2022. A general characteristics were the age, gender, curriculum (3 or 4 years), grade and area. The IL, UL, learning satisfaction (LS), learning achievement (LA) and intention to continue using (ICU) were analyzed by using the 5 point Likert scale. There was no significant difference the LS, LA, and ICU according to general characteristics (p>0.05). There was a statistically significant difference a total of sixteen subjects based on the t-test results of the response values from the IL and UL (p<0.05). The total of ten subjects with the highest priority in the Locus for Focus models were the Ultrasonography, Human anatomy, Magnetic resonance imaging, Radiation therapy, Cardiovascular and intervention, Computed tomography, Human physiology, Radiographic imaging, Fluroscopic radiography, and Nuclear medicine) that the Borich's need was also the same as the top 10 ranked subjects. The LS (4.23±0.72), LA (4.18±0.73), and ICU (4.15±0.78) for open chatting room were high. This study identified the subjects most needed by college students by the Borich's need analysis. First, it is necessary to provide intensive education on subjects with high scores that are most needed by college students. Second, it is necessary to improve the teaching method for subjects with low need and low level of understanding.

두경부 혈관종 진단시 $^{99m}Tc$-RBC Scan and SPECT 검사의 유용성 (Usefulness of $^{99m}Tc$-labeled RBC Scan and SPECT in the Diagnosis of Head and Neck Hemangiomas)

  • 오신현;노동욱;안샤론;박훈희;이승재;강천구;김재삼;이창호
    • 핵의학기술
    • /
    • 제12권1호
    • /
    • pp.39-43
    • /
    • 2008
  • 혈관종의 진단에 초음파(US), 전산화단층촬영영상(CT), 자기공명영상(MRI), 핵의학 검사 등 다양한 검사방법이 사용 될 수 있지만 $^{99m}Tc$ 표지 적혈구를 이용한 혈액풀 영상검사는 단일광자단층촬영(SPECT)의 발달로 혈관종을 확진하고 배제할 수 있는 가장 경제적일 뿐 아니라 비침습적이고 시행 하기도 쉬운 확실한 방법으로 사용되고 있다. 본 연구에서는 간 혈관종 외 두경부 (head and neck) 혈관종 진단시 $^{99m}Tc$-RBC scan and SPECT 검사의 유용성에 대하여 알아보고자 한다. 혈관종의 진단을 위해 본원 핵의학과에 내원한 6명의 환자를 대상으로 하였다. 6명의 환자 중 두부 부위 4명, 경부 부위 1명은 혈관종이라 추정하였고, 1명은 혈관종으로 의심되었다. 변형 체내 표지법(modified in vivo method)을 사용하여 표지하고 원심침전시켜 혈장을 제거한 다음 $^{99m}Tc$-RBC를 순 간주사하였다. 혈류기 영상을 얻은 후 즉시 전면상, 후면상, 양측면상의 혈액풀 영상을 얻었고 4시간 후 동일한 지연 영상을 얻었다. SPECT 영상은 이중 검출기(dual head detector)를 이용하여 64 projections ($180^{\circ}$)을 시행하였고 각 projection당 30초간 집적하였다. 모든 영상을 재구성한 후에 3명의 핵의학과 전문의, 핵의학과 전공의 및 핵의학과 방사선사가 특별한 정보없이 영상을 검토하였다. 혈관종으로 추정된 5명의 환자는 혈류기 영상에서 방사능은 증가하지 않았고 혈액풀 영상에서 증가하였으며 지연 영상과 SPECT 영상에서 증가된 소견을 보여 전형적인 혈관종 소견을 보였다. 혈관종이 아닌 1명의 환자는 혈류기 영상과 혈액풀 영상에서 방사능 증가를 보였고, 지연 영상과 SPECT 영상에서 감소된 소견을 보여 혈관종이 아닌 것으로 판정되었다. 5명의 혈관종 환자의 병소 크기는 모두 2 cm 이상이었고 SPECT 영상이 지연영상과 비교하여 뚜렷하게 병소 감별을 할 수 있었다. 간혈관종뿐만 아니라 두경부 혈관종이 의심되는 경우에는 비교적 경제적이고 비침습적이며 쉽게 시행할 수 있는 $^{99m}Tc$-RBC scan and SPECT 검사를 시행함으로써 초음파, 전산화 단층촬영영상, 자기공명영상 검사와 같은 다른 영상진단법과 함께 혈관종을 확진하고 배제하는데 의미있는 영상의학적 정보를 제공할 수 있다고 사료된다.

  • PDF

간질증후군의 $^{99m}Tc-HMPAO$ Brain SPECT; Ictal Study ($^{99m}Tc-HMPAO$ Brain SPECT in Medically Intraetable Epilepsy; Ictal Study)

  • 정태섭;서정호;김동익;이종두;박창윤;홍용국;이병인;허균
    • 대한핵의학회지
    • /
    • 제26권2호
    • /
    • pp.244-250
    • /
    • 1992
  • Both interictal and ictal $^{99m}Tc-HMPAO$ brain SPECT were performed in 22 patients with medically intractable epilepsy. Localization of epileptic foci in our patients was made by combined results of EEG and other tests, including Wada test, magnetic resonance imaging, and neuropsychometric test. Among them, ictal $^{99m}Tc-HMPAO$ SPECT, localized epilptic foci in 20 of 22 patients and provided evidence of epileptic focus in 12 patients by demonstrating maximally increased regional cerebral perfusion (rCP) in epileptic foci during the ictal study with decreased rCP in interictal study. Ictal $^{99m}Tc-HMPAO$ SPECT was particularly useful for investigating epileptic foci, and when correlated with simultaneously recorded ictal EEG, provided further insight for localizing epileptic foci. Conclusively, $^{99m}Tc-HMPAO$ SPECT is. a useful, noninvasive method of localizing epileptic activity which may be particularly important for presurgical investigations, especially in those patients without large morphological lesions.

  • PDF

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

전신 뼈 검사에서 $^{99m}Tc$-DPD의 미만성 간 섭취: MRI 조영제의 영향 (Diffuse Hepatic Uptake of $^{99m}Tc$-DPD on Whole Body Bone Scan: The Influence of MRI Contrast)

  • 윤종준;정지욱;황주원
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.57-61
    • /
    • 2012
  • 전신 뼈 검사에 이용되는 방사성의약품의 주된 집적부위는 뼈 무기질이며 그 섭취기전은 명백히 밝혀져 있지 않다. 전신 뼈 검사에서 일시적으로 미만성 간 섭취가 나타날 수 있으며, 간내 섭취의 원인은 다양하게 보고되고 있다. 본 연구에서는 전신 뼈 검사에서 $^{99m}Tc$-DPD의 미만성 간 섭취에 MRI 조영제가 미치는 영향을 알아보았다. 2010년 1월부터 12월 사이에 $^{99m}Tc$-DPD 전신 뼈 검사를 시행한 환자 중 982명을 연구의 대상으로 하였다. 982명의 환자는 전신 뼈 검사 이전에 MRI 조영제를 사용한 검사를 시행하였다. 혈액학검사 및 일반화학검사 소견을 조사한 결과 전신 뼈 검사에서 46명의 환자(남:여=39:7)가 미만성 간 섭취를 보였다. 추적 전신 뼈 검사를 시행하였으며, 이전에 보였던 미만성 간 섭취는 모두 소실되어 정상적인 소견을 보였다. 간기능 및 신기능 검사는 모두 정상이었다. 전신 뼈 검사에서 $^{99m}Tc$-DPD의 미만성 간 섭취에 MRI 조영제가 간접적인 영향을 주고 있다. $^{99m}Tc$-DPD의 미만성 간 섭취를 피하기 위해서 전신 뼈 검사는 MRI 조영제를 사용한 검사를 시행하기에 앞서서 먼저 시행하여야 하고, MRI 조영제를 사용한 검사가 있을 경우에는 조영제가 몸에서 제거된 후 검사를 시행하여야 할 것이다.

  • PDF

이차원 화학변위 기법을 이용한 간 및 심장 $^{31}P$ 자기공명분광에서의 Nuclear Overhauser 효과에 대한 연구 (The Effect of Nuclear Overhauser Enhancement in Liver and Heart $^{31}P$ NMR Spectra Localized by 2D Chemical Shift Technique)

  • 염헌규;이종민;김용선;이상권;서경진;배성진;장용민
    • Investigative Magnetic Resonance Imaging
    • /
    • 제8권2호
    • /
    • pp.94-99
    • /
    • 2004
  • 목적 : 인체의 심근 및 간조직의 생체내 $^{31}P$ MRS에서 NOE 효과에 의한 분광신호 세기의 증가를 평가하고자 하였으며 또한 동일 장기에서 대사물질에 따른 NOE 효과의 차이를 알아보고자 하였다. 대상 및 방법: 열명의 정상 성인군(남:여=8:2, 연령분포=24-32)을 대상으로 1.5T 자기공명영상/분광 장치에서 $^1H-^{31}P$ 이중 튜닝 표면 코일을 사용하여 생체내 $^{31}P$ MRS를 시행하였다. $^{31}P$ MRS 측정은 이차원 화학변위영상기법을 사용하였으며 동일한 파라미터에서 NOE 효과 없이 그리고 $^1H$ decoupling상태에서 NOE 효과에 의한 $^{31}P$ MRS 데이터를 획득하였다. $^{31}P$ MRS raw data의 postprocessing 후 얻어진 스펙트럼에서 주요 대사물질들의 신호증가를 비교하였다. 결과: 간조직의 $^{31}P$ HRS에서 NOE 효과에 의한 신호증가율은 $\alpha-ATP\;(7\%),\;\beta-ATP\;(9\%),\;\gamma-ATP\;(17\%),\;Pi\;(1\%),\;PDE\;(19\%),\;PME\;(31\%)$였다. 간조직의 경우 크리아틴 키나제가 없기 때문에 PCr 신호는 관찰되지 않았다. 심근의 $^{31}P$ MRS은 whole body 코일이 표면 코일보다 우수한 scout 영상을 제공하여 $^{31}P$ MRS의 localization에 유리하였다. $^{31}P$ 심근 다중 체적 스펙트럼에서 , 혈액의 DPG 신호는 심근으로부터 멀어질 수록 증가하는 양상을 나타내었고 NOE 효과에 의한 신호증가율은 $\alpha-ATP\;(12\%),\;\beta-ATP\;(19\%),\;\gamma-ATP\;(30\%),\;PCr\;(34\%),\;Pi\;(20\%),\;PDE\;(51\%),\;DPG\;(72\%)$ 였다. 결론: 간조직에 비해 심근의 경우 큰 신호증가를 보였고 이는 간조직 대사물질들의 $^{31}P$가 심근과는 다른 $^1H$ coupling을 나타냄을 의미한다고 해석할 수 있다.

  • PDF

뼈에 발생한 악성 림프종 환자의 치료 효과 판정에서 $^{18}F-FDG$ Positron Emission Tomography의 유용성 (Positron Emission Tomography with $^{18}F-FDG$ Fluorodeoxyglucose for Primary Lymphoma of Bone)

  • 김남돈;박연희;기승석;박용진;김형준;류백렬;김흥태;김성은;천기정;최창운;임상무
    • 대한핵의학회지
    • /
    • 제37권5호
    • /
    • pp.331-335
    • /
    • 2003
  • 원발성골림프종은 매우 드문 질환이기는 하나, 복합항암요법이나 방사선 치료등에 높은 반응율을 보이며, 좋은 예후를 가지는 림프절외 비호지킨 림프종의 일종이다. 그러나, 치료 효과 판정에 있어 골병변의 특이성에 의한 모호한 방사선학적 특징으로 어려움이 있어 왔다. 본 증례는 위와 같은 원발성골림프종 환자에서 PET 스캔을 사용하여 민감하게 완전 반응을 평가할 수 있었던 예로 앞으로 다른 고식적인 방법과 함께 이 질환의 진단과 치료 평가 있어 유용하게 사용 될 수 있을 것으로 전망할 수 있었다.

Quantitative Feasibility Evaluation of 11C-Methionine Positron Emission Tomography Images in Gamma Knife Radiosurgery : Phantom-Based Study and Clinical Application

  • Lim, Sa-Hoe;Jung, Tae-Young;Jung, Shin;Kim, In-Young;Moon, Kyung-Sub;Kwon, Seong-Young;Jang, Woo-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권4호
    • /
    • pp.476-486
    • /
    • 2019
  • Objective : The functional information of $^{11}C$-methionine positron emission tomography (MET-PET) images can be applied for Gamma knife radiosurgery (GKR) and its image quality may affect defining the tumor. This study conducted the phantom-based evaluation for geometric accuracy and functional characteristic of diagnostic MET-PET image co-registered with stereotactic image in Leksell $GammaPlan^{(R)}$ (LGP) and also investigated clinical application of these images in metastatic brain tumors. Methods : Two types of cylindrical acrylic phantoms fabricated in-house were used for this study : the phantom with an array-shaped axial rod insert and the phantom with different sized tube indicators. The phantoms were mounted on the stereotactic frame and scanned using computed tomography (CT), magnetic resonance imaging (MRI), and PET system. Three-dimensional coordinate values on co-registered MET-PET images were compared with those on stereotactic CT image in LGP. MET uptake values of different sized indicators inside phantom were evaluated. We also evaluated the CT and MRI co-registered stereotactic MET-PET images with MR-enhancing volume and PET-metabolic tumor volume (MTV) in 14 metastatic brain tumors. Results : Imaging distortion of MET-PET was maintained stable at less than approximately 3% on mean value. There was no statistical difference in the geometric accuracy according to co-registered reference stereotactic images. In functional characteristic study for MET-PET image, the indicator on the lateral side of the phantom exhibited higher uptake than that on the medial side. This effect decreased as the size of the object increased. In 14 metastatic tumors, the median matching percentage between MR-enhancing volume and PET-MTV was 36.8% on PET/MR fusion images and 39.9% on PET/CT fusion images. Conclusion : The geometric accuracy of the diagnostic MET-PET co-registered with stereotactic MR in LGP is acceptable on phantom-based study. However, the MET-PET images could the limitations in providing exact stereotactic information in clinical study.