• Title/Summary/Keyword: ns-2

Search Result 1,729, Processing Time 0.036 seconds

Thermoluminescence Properties of Elpasolite Scintillation Single Crystal (엘파소라이트 섬광형 단결정의 열형광 특성)

  • Kim, Sung-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.2
    • /
    • pp.492-497
    • /
    • 2012
  • In this paper, we determined the scintillation and thermoluminescence properties of $Cs_2NaCeBr_6$ elpasolite scintillation crystal. The emission spectrum of $Cs_2NaCeBr_6$ is located in the range of 300 ~ 450 nm, peaking at 377 nm and 400 nm. And, the fluorescence decay time of the crystal is composed two components. The fast component is 140 ns (94%), and the slow component is 880 ns (6%) of the crystal. The after-glow is caused by the electron and hole traps in the crystal lattices. We determined thermoluminescence parameters of the traps in the crystal. The determined activation energy(E), kinetic order and frequency factor of the traps are 0.67 eV, 1.71 and $2.51{\times}10^8s^{-1}$ respectively. In this crystal, re-combination rate is more dominant phenomenon than the re-trapping rate.

Determination of Electron Spin Relaxation Time of the Gadolinium-Chealted MRI Contrast Agents by Using an X-band EPR Technique (EPR을 통한 상자성 자기공명 조영제의 전자스핀 이완시간의 결정)

  • Sung-wook Hong;Yongmin Chang;Moon-jung Hwang;Il-su Rhee;Duk-Sik Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.1
    • /
    • pp.27-33
    • /
    • 2000
  • Purpose: To determine the electronic spin relaxation times, $T_{le}$, of three commercially available Gd-chelated MR contrast agents, Gd-DTPA, Gd-DTPA-BMA and Gd-DOTA, using Electron Paramagnetic Resonance(EPR) technique. Material and Methods: The paramagnetic MR contrast agents, Gd-DTFA(Magnevist) , Gd-DTFA-BMA(OMNISCAN) and Gd-DOTA(Dotarem), were used for this study, The EPR spectra of these contrast agents, which were prepared 2:1 methanol/water solution, were obtained at low temperatures, from $-160^{\circ}C~20^{\circ}C$. The glassy-state EPR spectra for these contrast agents were then fitted by the simulation spectra generated with different zero-field splitting (ZFS) parameters by a computer simulation program 'GEN', which generates the EPR powder spectrum using a given ZFS in $3{\times}3$ tensor. Finally, the spin relaxation times of the contrast agents were then determined from the $T_{2e}$, D, and E values of the best simulation spectra using the McLachlan's theory of average relaxation rate. Results: The electronic transverse spin relaxation times, $T_{2e}'s$, of Gd-DTPA, Gd-DTPA-BMA and Gd-DOTA were 0.113ns, 0.147ns and 1.81ns respectively. The g-values were 1.9737, 1.9735 and 1.9830 and the electronic spin relaxation times, $T_{1e}'s$, were 18.70ns, 33.40ns and $1.66{\mu}s$, respectively. Conclusion: The results of these studies reconfirm that the paramagnetic MR contrast agents with larger ZFS parameters should have shorter $T_{1e}'s$. Among three contrast agents used for this study, Gd-DOTA chelated with cyclic ligand structure shows better electronic property then the others with linear structure. Thus, it is concluded that the exact determination of ZFS parameters is the important factor in evaluating relaxation enhancement effect of the agents and in developing new contrast agents.

  • PDF

Receiver DCB Estimation and Analysis by Types of GPS Receiver

  • Choi, Byung-Kyu;Chung, Jong-Kyun;Cho, Jeong-Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.2
    • /
    • pp.123-128
    • /
    • 2010
  • This paper analyzes that the global positioning system (GPS) receiver differential code bias (DCB) has effect on the estimation the ionosphere total electron content (TEC). The data from nine permanent GPS sites of the Korea Astronomy and Space Science Institute (KASI) were used for the estimation of the receiver DCB before (Trimble 4000 SSi) and after (Trimble NetRS) the receiver replacement, using the singular value decomposition method. The results showed that the estimated mean value of the receiver DCB varied from 0.11 ns (nanosecond) to 7.54 ns before the receiver replacement, but the receiver DCBs shoed large values than 20 ns except some stations after the replacement. The receiver DCB showed a relatively large difference by types of the receivers, and, as a result, it had a great effect on the estimation the ionosphere TEC using GPS.

$\alpha$-Glucosidase Inhibition by Culture Broth of Streptomyces sp. NS15 (Streptomyces sp. NS15 배양액에 의한 $\alpha$-Glucosidase 저해)

  • 백남수;김영만
    • The Korean Journal of Food And Nutrition
    • /
    • v.11 no.6
    • /
    • pp.640-646
    • /
    • 1998
  • For the production of nonprotein $\alpha$-glucosidase inhibitor from the Streptomyces sp. NS15 strain, effects of initial optimum pH, nitrogen sources, carbon sources, cationic metal ions, agitation speed and aeration rate were investigated. Initial optimum pH of medium was 7.0. The most effective nitrogen and carbon sources were soybean meal 2.0%(w/v) and glucose 1.6%(w/v), respectively. The cationic metal ins had no stimulating effect on inhibitory activity of $\alpha$-glucosidase except Fe2+. Agitation speed and aeration rate were effective at 400rpm and 1vvm, respectively. In the jar-fermenter cultivation for 4 days under optimal culture conditions, the culture broth showed the inhibitory acitivity of 3,200units/ml, which is 25 times higher than that of basic medium (CYM) for porcine intestinal $\alpha$-glucosidase. The inhibitory activity of $\alpha$-glucosidase reached about 3,200units/ml after 4 days of cultivation and decreased gradually for a further two days.

  • PDF

Effect of Auxiliary Address Pulse on Face-to-face Sustain Electrode Structure in AC-PDP

  • Kim, Bo-Sung;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.605-608
    • /
    • 2007
  • The discharge characteristics of the face-to-face sustain electrode structure employing auxiliary address pulse are investigated under a sustain driving frequency of 20 kHz and various auxiliary address pulse widths (500 ns, $1{\mu}s$, $2\;{\mu}s$) in the 6-in. test panel (42-in. Full HD grade) with a pressure of 450 Torr and a 4 % Xe-content. The luminance and the luminous efficiency at the auxiliary address pulse width of 500 ns are improved more than these of $1\;{\mu}s$ and $2\;{\mu}s$. At the auxiliary address pulse width of 500 ns, the luminous efficiency shows about 0.96 lm/W at the auxiliary pulse of 90 V and the sustain voltage of 260 V.

  • PDF

Tunable Composite Right/Left-Handed Delay Line with Large Group Delay for an FMCW Radar Transmitter

  • Park, Yong-Min;Ki, Dong-Wook
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.2
    • /
    • pp.166-170
    • /
    • 2012
  • This paper presents a tunable composite right/left-handed (CRLH) delay line for a delay line discriminator that linearizes modulated frequency sweep in a frequency modulated continuous wave (FMCW) radar transmitter. The tunable delay line consists of 8 cascaded unit cells with series varactor diodes and shunt inductors. The reverse bias voltage of the varactor diode controlled the group delay through its junction capacitance. The measured results demonstrate a group delay of 8.12 ns and an insertion loss of 4.5 dB at 250 MHz, while a control voltage can be used to adjust the group delay by approximately 15 ns. A group delay per unit cell of approximately 1 ns was obtained, which is very large when compared with previously published results. This group delay can be used effectively in FMCW radar transmitters.

The Modulation of Radiosensitivity by Combined Treatment of Selective COX-2 Inhibitor, NS 398 and EGF Receptor Blocker AG 1478 in HeLa Cell Line (선택적 COX-2 억제제 NS 398과 EGF 수용체 차단제 AG 1478의 복합투여가 HeLa 세포주의 방사선 감수성에 미치는 영향)

  • Youn Seon Min;Oh Young Kee;Kim Joo Heon;Park Mi Ja;Seong In Ock;Kang Kimun;Chai Gyuyong
    • Radiation Oncology Journal
    • /
    • v.23 no.1
    • /
    • pp.51-60
    • /
    • 2005
  • Purpose : Selective inhibition of multiple molecular targets may improve the antitumor activity of radiation. Two specific inhibitors of selective cyclooxygenase-2 (COX-2) and epidermal growth factor receptor (EGFR) were combined with radiation on the HeLa cell line. To investigate cooperative mechanism with selective COX-2 inhibitor and EGFR blocker, in vitro experiments were done. Materials and Methods : Antitumor effect was obtained by growth inhibition and apoptosis analysis by annexin V-Flous method. Radiation modulation effects were determined by the clonogenic cell survival assay. Surviving fractions at 2 Gy ($SF_2$) and dose enhancement ratio at a surviving fraction of 0.25 were evaluated. To investigate the mechanism of the modulation of radiosensitivity, the cell cycle analyses were done by flow cytometry. The bcl-2 and bax expressions were analyzed by western blot. Results : A cooperative effect were observed on the apoptosis of the HeLa ceil line when combination of the two drugs, AG 1478 and NS 398 with radiation at the lowest doses, apoptosis of $22.70\%$ compare with combination of the one drug with radiation, apoptosis of $8.49\%$. In cell cycle analysis, accumulation of cell on $G_0/G_l$ phase and decrement of S phase fraction was observed from 24 hours to 72 hours after treatment with radiation, AG 1478 and NS 398. The combination of NS 398 and AG 1478 enhanced radiosensitivity on a concentration-dependent manner in HeLa cells with dose enhancement ratios of 3.00 and $SF_2$ of 0.12 but the combination of one drug with radiation was not enhanced radlosensitivity with dose enhancement ratios of 1.12 and SF2 of 0.68 (p=0.005). The expression levels of bcl-2 and bax were reduced when combined with AG 1478 and NS 398. Conclusion : Our results indicate that the selective COX-2 inhibitor and EGFR blocker combined with radiation have potential additive or cooperative effects on radiation treatment and may act through various mechanisms including direct inhibition of tumor cell proliferation, suppression of tumor cell cycle progression and inhibition of anti-apoptotic proteins.

The noise impacts of the open bit line and noise improvement technique for DRAM (DRAM에서 open bit line의 데이터 패턴에 따른 노이즈(noise) 영향 및 개선기법)

  • Lee, Joong-Ho
    • Journal of IKEEE
    • /
    • v.17 no.3
    • /
    • pp.260-266
    • /
    • 2013
  • The open bit line is vulnerable to noise compared to the folded bit line when read/write for the DRAM. According to the increasing DRAM densities, the core circuit operating conditions is exacerbated by the noise when it comes to the open bit line 6F2(F : Feature Size) structure. In this paper, the interference effects were analyzed by the data patterns between the bit line by experiments. It was beyond the scope of existing research. 68nm Tech. 1Gb DDR2, Advan Tester used in the experiments. The noise effects appears the degrade of internal operation margin of DRAM. This paper investigates sense amplifier power line splits by experiments. The noise can be improved by 0.2ns(1.3%)~1.9ns(12.7%), when the sense amplifier power lines split. It was simulated by 68nm Technology 1Gb DDR2 modeling.

Design of a 64×64-Bit Modified Booth Multiplier Using Current-Mode CMOS Quarternary Logic Circuits (전류모드 CMOS 4치 논리회로를 이용한 64×64-비트 변형된 Booth 곱셈기 설계)

  • Kim, Jeong-Beom
    • The KIPS Transactions:PartA
    • /
    • v.14A no.4
    • /
    • pp.203-208
    • /
    • 2007
  • This paper proposes a $64{\times}64$ Modified Booth multiplier using CMOS multi-valued logic circuits. The multiplier based on the radix-4 algorithm is designed with current mode CMOS quaternary logic circuits. Designed multiplier is reduced the transistor count by 64.4% compared with the voltage mode binary multiplier. The multiplier is designed with Samsung $0.35{\mu}m$ standard CMOS process at a 3.3V supply voltage and unit current $5{\mu}m$. The validity and effectiveness are verified through the HSPICE simulation. The voltage mode binary multiplier is achieved the occupied area of $7.5{\times}9.4mm^2$, the maximum propagation delay time of 9.8ns and the average power consumption of 45.2mW. This multiplier is achieved the maximum propagation delay time of 11.9ns and the average power consumption of 49.7mW. The designed multiplier is reduced the occupied area by 42.5% compared with the voltage mode binary multiplier.

Thermoluminescence of Rb2LiCeCl6 Halide Scintillator (Rb2LiCeCl6 할라이드 섬광체의 열형광 특성)

  • Kim, Sunghwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.1211-1215
    • /
    • 2014
  • We developed a new $Rb_2LiCeCl_6$ scintillator and determined the scintillation and thermoluminescence properties of the scintillator. The emission spectrum of $Rb_2LiCeCl$ is located in the range of 350 ~ 410 nm, peaking at 368 nm and 378 nm, due to the 4f ${\rightarrow}$ 5d transition of $Ce^{3+}$ ions. The fluorescence decay time of the crystal is composed two components. The fast component is 71 ns (85%) and the slow component is 405 ns (15%) of the crystal. The after-glow is caused by the electron and hole traps in the crystal lattice. We determined physical parameters of the traps in the crystal. The determined activation energy(E), kinetic order(m) and frequency factor(s) of the trap are 0.75 eV, 1.48 and $3.0{\times}10^8s^{-1}$, respectively.