• 제목/요약/키워드: normal temperature

검색결과 2,456건 처리시간 0.028초

식사 전 후의 체온변화와 신체계측치와의 관련성 (Relationshops between Body Temperature Changes and Adiposity during a Meal)

  • 김석영
    • Journal of Nutrition and Health
    • /
    • 제31권4호
    • /
    • pp.747-755
    • /
    • 1998
  • In order to study the relationship between body core temperature and adiposity , the core temperatures of normal weight female college students were measured during an instant-noodle lunch eaten in a laboratory at the ambient temperature of 22-24.8$^{\circ}C$. Ambient temperature was positively correlated with meal-start core temperature and meal duration. The difference between the peak postprandial and the meal-start core temperature was negatively correlated with body weight and BMI. This means that the thermogenic response induced by meal consumption was negatively associated with adiposity. Meal duration also showed a negative correlation with body weight, BMI, and hip girth. Thus, the obese eating style characterized by a rapid rate of food intake was also associated with adiposity in normal weight women. It was possibly a contributing factor in the development of obesity. In conclusion, adiposity is negatively associated with the difference between the peak postprandial and the meal-start core temperature and meal duration during a meal.

  • PDF

돼지 액상정액을 위한 희석액 및 저온보존에 관한 연구 (A Study on Extender and Lower Temperature Storage for Fresh-extended Porcine Semen)

  • 김명철;김용준;조정곤;이수진;이재일;김인철;손동수
    • 한국임상수의학회지
    • /
    • 제18권4호
    • /
    • pp.345-349
    • /
    • 2001
  • The aim of this study was to investigate the effect of sperm preservation according to the various kinds of commercially available semen extenders and to investigate the effect of sperm preservation according to the various temperature storages of fresh-extended porcine semen. To investigate the effect of sperm preservation according to the various kinds of commercially available semen extenders, porcine semens diluted in 3 semen extenders, Beltsville Thawing Solution(BTS), Androhep and Kiev, were cooled at $8^{\circ}C$ storage temperature with a controlled cooling rate of $2-4^{\circ}C$/h. Motility, progressive motility, normal sperm(%) and sperm morphology were assessed comparatively. In motility and progressive motility, Androhep extenders revealed better result than other extenders. In normal sperm(%) and sperm morphology, 3 semen extenders revealed similar results. To investigate the effect of sperm preservation according to the various temperature storages of fresh-extended porcine semen, porcine semens diluted in BTS extender, were cooled at 3 storage temperatures($8^{\circ}C$, $12^{\circ}C$ and $17^{\circ}C$) with a controlled cooling rate of $2-4^{\circ}C$/h. Motility, progressive motility, normal sperm(%) and sperm morphology were assessed comparatively. In motility and progressive motility, $8^{\circ}C$ treatment group revealed better result than $12^{\circ}C$ and $17^{\circ}C$ treatment groups. In normal sperm(%) and sperm morphology, 3 temperatures of treatment groups revealed similar results.

  • PDF

Characteristics of Complex Foaming Composites' Normal Pressure Foaming of Using Rubber and Bio-Degradable Materials

  • Dong Hun Han;Young Min Kim;Dan Bi Lee;Kyu Hwan Lee;Han-Seong Kim
    • 한국재료학회지
    • /
    • 제33권8호
    • /
    • pp.323-329
    • /
    • 2023
  • There are many types of foam molding methods. The most commonly used methods are the pressure foaming method, in which foam resin is mixed with a foaming agent at high temperature and high pressure, and the normal pressure foaming method, which foams at high temperature without pressure. The polymer resins used for foaming have different viscosities. For foaming under normal pressure, they need to be designed and analyzed for optimal foaming conditions, to obtain resins with low melt-viscosity or a narrow optimal viscosity range. This study investigated how changes in viscosity, molding temperature, and cross-link foaming conditions affected the characteristics of the molded foam, prepared by blending rubber polymer with biodegradable resin. The morphologies of cross sections and the cell structures of the normal pressure foam were investigated by SEM analysis. Properties were also studied according to cross-link/foaming conditions and torque. Also, the correlation between foaming characteristics was studied by analyzing tensile strength and elongation, which are mechanical properties of foaming composites.

Temperature distribution analysis of steel box-girder based on long-term monitoring data

  • Wang, Hao;Zhu, Qingxin;Zou, Zhongqin;Xing, Chenxi;Feng, Dongming;Tao, Tianyou
    • Smart Structures and Systems
    • /
    • 제25권5호
    • /
    • pp.593-604
    • /
    • 2020
  • Temperature may have more significant influences on structural responses than operational loads or structural damage. Therefore, a comprehensive understanding of temperature distributions has great significance for proper design and maintenance of bridges. In this study, the temperature distribution of the steel box girder is systematically investigated based on the structural health monitoring system (SHMS) of the Sutong Cable-stayed Bridge. Specifically, the characteristics of the temperature and temperature difference between different measurement points are studied based on field temperature measurements. Accordingly, the probability density distributions of the temperature and temperature difference are calculated statistically, which are further described by the general formulas. The results indicate that: (1) the temperature and temperature difference exhibit distinct seasonal characteristics and strong periodicity, and the temperature and temperature difference among different measurement points are strongly correlated, respectively; (2) the probability density of the temperature difference distribution presents strong non-Gaussian characteristics; (3) the probability density function of temperature can be described by the weighted sum of four Normal distributions. Meanwhile, the temperature difference can be described by the weighted sum of Weibull distribution and Normal distribution.

3단 스피드 선풍기 모터의 정상 및 고정 운전에 대한 전압, 전류 및 온도 신호 분석 (Analysis on the Voltage, Current and Temperature Signals for Free and Locked Operation of Three Speed Electric Fan)

  • 김윤복;김두현
    • 한국화재소방학회논문지
    • /
    • 제28권3호
    • /
    • pp.87-91
    • /
    • 2014
  • 본 논문은 선풍기 모터의 회전을 정상 및 고정상태로 구분하여 주권선에서의 전압 및 전류, 모터 전체의 온도특성을 분석하여 전기화재 위험성을 제시하는 것을 목표로 하고 있다. 전압과 전류 신호에 대하여, 전압의 경우 정상상태와 고정상태에 대하여 큰 차이점은 없었으며, 전류의 경우는 비정상상태(최대 203 mA)보다 정상상태(최대 309 mA)가 상당히 높았다. 온도신호의 경우, 모터 전반에 있어서 온도 분포도가 다르게 나타났으며, 정상상태의 경우는 $4^{\circ}C$, 고정상태는 $18^{\circ}C$ 차를 보였다. 특히 대부분의 선풍기의 전기배선이 모터의 고정자철심에 부착되어 있었으며 해당전선의 허용온도가 $60^{\circ}C$를 감안했을 때에 절연열화가 가속될 수 있다. 또한 본 데이터는 선풍기 안전장치개발의 기초자료나 전기화재에 대한 조사 자료로 활용할 수 있다.

지대치 형성이 치수온도에 미치는 영향에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF THE EFFECT ON PULP TEMPERATURE DURING ABUTMENT PREPARATION)

  • 김병기
    • 대한치과보철학회지
    • /
    • 제14권1호
    • /
    • pp.47-54
    • /
    • 1976
  • Pulpal temperature is changed in response for various conditions which were mechanical, thermal, chemical and biological stimuli. This study was performed to determine the pulpal temperature changes which were using air turbine with air-water coolant, water coolant, and conventional dental engine with water coolant and no coolant on 28 canine of dogs. In order to record pulpal temperature, pulp chamber was opened on the labiocervical area of canine. Thermocouple was inserted into pulp chamber and was fixed with filling material(dycal). Changes of pulpal temperature were recorded on the physiograph, which had been standardized temperature degree, through thermocouple to thermistor bridge and carrier preamplifier. The amount of experimental temperature change to that of control was interpreted in the pulpal cavity. The obtained results were as followings: 1. The mean normal temperature was 33.07 centigrade. 2. The temperature was decreased than normal pulpal temperature. It was 12.04 centigrade in reduction by air turbine with air-water coolant, 7.17 centigrade in reduction by air turbine with air coolant, 5.54 centigrade in reduction by conventional engine with water coolant, and 1.26 centigrade in reduction by conventional engine with no coolant. 3. The time for maximal temperature change was 53.3 seconds in reduction by air turbine with air-water coolant, 73.4 seconds in reduction by air turbine with air coolant, 50.9 seconds in reduction by conventional engine with water coolant, and 27.1 seconds in reduction by conventional engine with no coolant. 4.. After reduction was ceased, the recovery time to normal pulp temperature was 287.1 seconds in air turbine with air-water coolant, 189.0 seconds in air turbine with air coolant, 86.9 seconds in conventional engine with water coolant, and 52.9 seconds in conventional engine with no coolant respectively.

  • PDF

가을보리 재배기간중의 기상변화 (Analysis of Meteorological Variation during Winter Barley Cropping Season in Korea)

  • 심교문;이정택;윤성호;황규홍
    • 한국농림기상학회지
    • /
    • 제2권3호
    • /
    • pp.95-102
    • /
    • 2000
  • 근래의 '춥지 않은 겨울'현상의 연속출현으로 가을 보리의 재배지역의 북상에 따른 재배면적 확대를 논의 할 만하다. 최근('74∼'98년)의 가을보리재배기간(10∼5월)의 기상변화를 살펴보고 '87년을 기준으로 '춥지 않은 겨울현상'을 보인 13년('87∼'99년) 그전 13년('74∼'86년)의 가을보리 재배기간의 기상을 평년('61∼'90년)기상과 비교ㆍ분석한 결과는 다음과 같다. 1. 최근 25년 동안 가을보리재배기간의 평균기온은 1.02℃ 증가하였으며, 평균기온의 상승은 최저기온보다 최고기온의 상승이 더 크게 기여하였다. 2. 가을보리재배기간의 연도별 강수량은 최근 25년 동안 전국평균이 513.3 ㎜ 이었으며.'74년 이후 감소하다가 '92년 이후로는 다시 증가하는 경향이었으며, 일조시간은 농촌지역만 조금 적어지는 경향이고 다른 지역들은 조금씩 증가하는 경향을 보였다. 3. '춥지 않은 겨울' 현상을 보인 최근 13년의 가을보리재배기간의 기온은 평년보다 높았으며 특히 1∼2월의 기온이 많이 상승하였다 반면에 '87년을 기준으로 그전 13년의 기온은 평년과 비슷하거나 다소 낮은 경향을 보였다. 4. '춥지 않은 겨울'현상을 보인 최근 13년의 가을 보리재배기간의 강수량은 평년과 전반적으로 비슷하였으나, 4월의 강수량이 전국적으로 평년보다 26㎜정도 적었다. 반면에 일조시간은 전반적으로 평년보다 적었다 그러나, '87년을 기준으로 그전 13년의 강수량과 일조시간은 대체로 평년과 비슷하였다. 5. 가을보리의 안전재배선의 기준이 되는 월동기(1∼2월)의 기온상승으로 가을보리안전재배의 북상이 전망된다.

  • PDF

A STUDY ON THE INCUBATION OF INDIGENOUS (DESI), KHAKI CAMPBELL AND CROSSBRED (INDIAN RUNNER × KHAKI CAMPBELL, F1) DUCK EGGS UNDER TWO PRE-INCUBATION HOLDING PERIODS

  • Saha, S.K.;Chowdhury, S.D.;Hamid, M.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제5권3호
    • /
    • pp.541-544
    • /
    • 1992
  • Duck eggs from Indigenous (desi), Khaki Campbell and Crossbred (Indian Runner $\times$ Khaki Campbell, $F_1$) were incubated to investigate fertility, hatchability and other related traits. The fertility was highest in crossbred followed by Khaki Campbell and Indigenous ducks respectively. The embryonic mortality was highest in Khaki Campbell followed by Indigenous and crossbred respectively. The embryonic mortality was higher in eggs of 7 days pre-incubation holding period and lower in eggs of 3 days pre-incubation holding period. A significant positive correlation was found between temperature and embryonic mortality as well as relative humidity and embryonic mortality. The hatchability on fertile eggs was highest in crossbred ducks and almost similar in both Khaki Campbell and Indigenous ducks. The hatchability was higher in eggs stored for 3 days in comparison with that of 7 days pre-incubation holding period. A negative correlation was found between temperature and hatchability as well as humidity and hatchability. The normal ducklings hatched out from the eggs of Khaki Campbell ducks was highest followed by Indigenous and crossbred respectively. There was a negative correlation between temperature and normal ducklings hatched as well as relative humidity and normal ducklings hatched. The preincubation holding temperature and relative humidity had positive correlation with dead-in-shell.

초전도 결정의 저온 비열 점프의 자기장 의존성 (Magnetic Field Dependence of Low Temperature Specific Heat Jump in Superconducting Crystal)

  • 김철호
    • 한국재료학회지
    • /
    • 제21권2호
    • /
    • pp.73-77
    • /
    • 2011
  • Specific heat of a crystal is the sum of electronic specific heat, which is the specific heat of conduction electrons, and lattice specific heat, which is the specific heat of the lattice. Since properties such as crystal structure and Debye temperature do not change even in the superconducting state, the lattice specific heat may remain unchanged between the normal and the superconducting state. The difference of specific heat between the normal and superconducting state may be caused only by the electronic specific heat difference between the normal and superconducting states. Critical temperature, at which transition occurs, becomes lower than $T_{c0}$ under the influence of a magnetic field. It is well known that specific heat also changes abruptly at this critical temperature, but magnetic field dependence of jump of specific heat has not yet been developed theoretically. In this paper, specific heat jump of superconducting crystals at low temperature is derived as an explicit function of applied magnetic field H by using the thermodynamic relations of A. C. Rose-Innes and E. H. Rhoderick. The derived specific heat jump is compared with experimental data for superconducting crystals of $MgCNi_3$, $LiTi_2O_4$ and $Nd_{0.5}Ca_{0.5}MnO_3$. Our specific heat jump function well explains the jump up or down phenomena of superconducting crystals.

커넥터에서 접촉불량 발생시의 전압, 전류 및 온도 신호 특성 분석 (Analysis of Voltage, Current and Temperature Signals for Poor Connections at Electrical Connector)

  • 김상철;김두현;강신욱
    • 한국안전학회지
    • /
    • 제29권2호
    • /
    • pp.12-17
    • /
    • 2014
  • This paper is aimed to analyze the characteristics of simultaneous voltage, current and temperature signals for poor connection on electrical connector. In order to attain this purpose, detected were the current and voltage signals on electric wire with series arc, named arc signals, and also monitored were the changes of RMS, instantaneous value of waveform in time domain and temperature value with video. Two states are made normal state over $5kgf{\cdot}cm$ and poor connections state below $0.5kgf{\cdot}cm$ by screw gage. In the voltage signal case, the voltage drop was increased with which the current was increased. In the current signal case, poor connections at the time interval 1~4A all showed "shoulder", as distinct difference from the normal state shown waveform pattern. In the temperature signal case, poor connections are twice at 1A and five times at 4A in the normal state. The temperature continues insulation of electrical wiring and connector can be carbonized. The results of this study will be effectively used in developing the preventive devices and system for electric fire by poor connections.