Abstract
This paper is aimed to find electrical fire danger for analyzing the characteristics of temperature, current and voltage signals for motor on electric fan. In order to attain this purpose, detected were the temperature, current and voltage signals on electric wire with free (normal state) and locked (abnormal state) motor. For voltage and current signals, voltage signal is no big difference with normal and abnormal states and current signal is higher in abnormal state (highest 309 mA) than the normal state (highest 203 mA). In the case of Temperature signal, the temperature distribution of the motor as a whole is different. It is difference in the case of the normal state $4^{\circ}C$ and the abnormal state $18^{\circ}C$. In particular, most of the electric wiring to the motor of the fan is attached to the fixture of motor back. Considering at allowable temperature ($60^{\circ}C$) of the electric wire could be accelerated to insulation deterioration. The results of this study will be effectively used in analyzing for electric fire and developing the preventive devices of electric fan.
Keywords
Electrical fire; Electric fan; Temperature; Current and voltage signals; Insulation deterioration;
Citations & Related Records
연도 인용수 순위
  • Reference
1 National Fire Data System, "http://www.nfds.go.kr/", (2014).
2 Tokyo Fire Department, "New Fire Investigation Handbook", pp. 148-153 (2004).
3 SEGYE.com, "Motel fire by internal defects of fans manufacturers pay your insurance 60%" (2014).
4 119New, 'Caution' of fan fire in Summer, 2013.
5 H. S. Kim, H. R. Kim, C. S. Choi and J. H. Chung, "The Analysis of the Fire Hazard According to Layer Short- Circuit of Motor Winding for the Fan", Proceedings of the Korea Institute of Fire Science and Engineering Conference, pp. 135-139 (2000).   과학기술학회마을
6 S. H. Hong, S. H. Lee, S. T. Park, H. J. Yu and W. J. Jeon, "A Experiment Study on the Electrical Fire Hazards Analysis of Electric Fan", Proceedings of the Korea Institute of Fire Science and Engineering Conference, pp. 344-349 (2007).
7 Korean Industrial Standard, "KSC 3304" (2006).
8 Korean Industrial Standard, K60335-2-80, K60335-1(4.1) (2004).