• 제목/요약/키워드: normal structure

Search Result 2,202, Processing Time 0.09 seconds

Gene Expression Profile Associated with the Differentiation of Osteoblasts from Human Mesenchymal Stem Cells (인간 중간엽 줄기세포로부터 골아세포로의 분화시 관찰되는 유전자 발현 분석)

  • Kim Yeo-Kyeoung;Kim Hee-Nam;Lee Il-Kwon;Park Kyeong-Soo;Yang Deok-Hwan;Cho Sang-Hee;Lee Je-Jung;Chung Ik-Joo;Kim Soon-Hag;Kim Hyeoung-Joon
    • Journal of Life Science
    • /
    • v.16 no.2 s.75
    • /
    • pp.231-239
    • /
    • 2006
  • Human mesenchymal stem cells (hMSCs) in bone marrow (BM) can be induced to differentiate into a variety of mesenchymal tissues, including adipocytes, osteoblasts and chondroblasts, under the influence of certain growth or environmental factors. In this study, we analyzed the differentiation process and the associated gene expression profiles inherent to the process by which hMSCs differentiate into osteoblasts. We conducted a comparison of gene expression profiles of the normal human BM MSCs, using human 8K cDNA microarray, incubated in media containing either a combination of $\beta$-glycerol phosphate, L-ascorbic acid, and dexamethasone, or in medium lacking these osteogenic supplements. During the osteoblastic differentiation process, 36 genes were determined to be up-regulated, and 59 genes were shown to be down-regulated. Osteoprotegerin, LRP5, and metallothionein 2A, all of which are associated with the osteogenetic process, were up-regulated, and genes associated with the differentiation of MSCs into other lineages, including muscle, adipose tissue and vascular structure were down-regulated. The set of differentially expressed genes reported in this work should contribute to our current understanding of the processes inherent to the differentiation of MSCs into osteoblasts.

Prenatal Care Utilization Pattern and Its Determinants in Rural Korea (농촌지역 모성의 산전관리서비스 이용양상과 그 결정요인)

  • Kim, Jang-Rak;Park, Jung-Han;Lee, Jae-Kyong;Seo, Sang-Hong;Bang, Joon-Yong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.4 s.44
    • /
    • pp.599-613
    • /
    • 1993
  • To study the pattern of prenatal care utilization and its determinants in rural Korea, 976 mothers (65.5%) out of 1,489 living mothers in Chinyang, Sachon and Hapchon Counties in Kyongsangnam Province who had delivered a baby between July 1, 1990 and June 30, 1991 were interviewed by the Myon health workers from January 3 through February 15, 1992. The Anderson's behavioral model for health service utilization was applied to develop the frames for analysis. The dependent variable was a number of prenatal care visits. And the independent variables included In the model were the variables pertaining to the predisposing, enabling, medical need and other components. The proportion of mother who had ever received the prenatal care service for the index pregnancy was 97.3%. However, the proportion of mothers who had made more than 10 visits was only 20.6%, which indicated that majority of mothers had paid far less visits than recommended $10{\sim}12$ visits for each normal pregnancy. The low utilization of prenatal care services (none or less than 4 visits) was related to mother's low educational level, the high birth order, beneficiary of the medical aid, the absence of clinic in the community, no diagnosed disease of mother during pregnancy, and mothers engaged in farming. Inequity of access seemed to exist because social structure variables and the variables of enabling component were important predictors. And there seemed to be high mutability in equalizing the distribution of prenatal care services because the variables of enabling component such as type of medical security and whether there was a clinic or not in the community were substantially important.

  • PDF

Compressive Behavior of Precast Concrete Column with Hollow Corresponding to Hollow Ratio (중공비율에 따른 중공 프리캐스트 철근콘크리트 기둥의 압축거동)

  • Lee, Seung-Jun;Seo, Soo-Yeon;Pei, Wenlong;Kim, Kang-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.441-448
    • /
    • 2014
  • From several researches, recently, it was found that using hollowed precast concrete (HPC) column made more compact concrete casting in joint region possible than using normal solid PC (Precast concrete) column. Therefore, the rigidity of joints can be improved like those of monolithic reinforced concrete (RC). After filling the hollow with grout concrete, however, it is expected that the HPC column behaviors like composite structure since PC element and grout concrete have different materials as well as there is a contact surface between two elements. These may affect the structural behavior and strength of the composite column. A compressive strength test was performed for the HPC column with parameter of hollow ratio for the case with and without grout in the hollow and the result is presented in this paper. The hollow ratios in the test are 35, 50 and 59% of whole section of column. Concentrated axial force was applied to top of the specimens supported as pin connection for both ends. In addition, finite element (FE) analysis was performed to simulate the failure behavior of HPC column for axial compression. As a result, it was found that the hollow ratio did not affect the initial stiffness of HPC filled with grout regardless of the strength difference of HPC and grout. However the strength was increased inversely corresponding to the hollow ratio. The structural capacity of HPC without grout closely related to the hollow size. Especially, the local collapse governs the overall failure when the thickness of HPC is too thin. Based on these effect, a suitable equation was suggested for calculation of the compressive strength of HPC column with or without grout. FE analysis considering the contact surface between HPC and grout produced a good result matched to the test result.

Development of Biocompatible Vascular Graft -Endothelialization of Small Vascular Graft- (생체적합성 인조혈관의 개발 -혈관내피화 인조혈관-)

  • 김형묵;이윤신
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.373-380
    • /
    • 1996
  • Prevention of thromboembolism is the most important task in the development of bioconpatible small caliber artificial vascular graft. In normal vessels, vascular endothelial cells maintain homeosatsis by secreting numerous factors. The aim of this study is to develope a method which Improves biocompatibility of small caliver polyurethane graft using endothelial cell culture technique, and ev luate the efTectiveness of extracelluar matrix for endothelization which was produced by cultured fibroblast. Methods ; Multiporous polyurethane tube of 3 mm diameter, 0.3 mm thickness was manufactured for vascular graft. Three mongrel dogs were intubated and internal jugular veins removed. Extracelluar matrix produced by cultured flbrobast which was obtained from dog's internal jugular vein were coated to the polyurethane graft. Then, endothelial cells extracted from Jugular vein were cultured and fixed on the extracelluar matrix layer of vascular graft. Endothelial cell coated vascular grafts were implanted to the carotid arteries of experimental dogs as interposed autograft. Implanted grafts were removed after 3 and 6 weeks. As a control, PTFE graft was interposed on carotid artery. These experiments demonstrated that extracelluar matrix produced by fibroblast can afford a base for endothelial cell linings of polyurethane graft. Although thrombosis were developed on autografted en othelial cell coated graft, 33% opening was noticed, and showed less adhesion to adjacent tissue layer. These findings suggest that fiboblast produced extracelluar matrix which can be used for edothelial cell lining vascular graft, and by improving the cultured endothelial cell function, there will be a new modality for reducing thrombosis on small vascular graft.

  • PDF

Structural Safety Test and Analysis of Type IP-2 Transport Packages with Bolted Lid Type and Thick Steel Plate for Radioactive Waste Drums in a NPP (원자력발전소의 방사성폐기물 드럼 운반을 위한 볼트체결방식의 두꺼운 철판을 이용한 IP-2형 운반용기의 구조 안전성 해석 및 시험)

  • Lee, Sang-Jin;Kim, Dong-hak;Lee, Kyung-Ho;Kim, Jeong-Mook;Seo, Ki-Seog
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.3
    • /
    • pp.199-212
    • /
    • 2007
  • If a type IP-2 transport package were to be subjected to a free drop test and a penetration test under the normal conditions of transport, it should prevent a loss or dispersal of the radioactive contents and a more than 20% increase in the maximum radiation level at any external surface of the package. In this paper, we suggested the analytic method to evaluate the structural safety of a type IP-2 transport package using a thick steel plate for a structure part and a bolt for tying a bolt. Using an analysis a loss or dispersal of the radioactive contents and a loss of shielding integrity were confirmed for two kinds of type IP-2 transport packages to transport radioactive waste drums from a waste facility to a temporary storage site in a nuclear power plant. Under the free drop condition the maximum average stress at the bolts and the maximum opening displacement of a lid were compared with the tensile stress of a bolt and the steps in a lid, which were made to avoid a streaming radiation in the shielding path, to evaluate a loss or dispersal of radioactive waste contents. Also a loss of shielding integrity was evaluated using the maximum decrease in a shielding thickness. To verify the impact dynamic analysis for free drop test condition and evaluate experimentally the safety of two kinds of type IP-2 transport packages, free drop tests were conducted with various drop directions. For the tests we examined the failure of bolts and the deformation of flange to evaluate a loss or dispersal of radioactive material and measured the shielding thickness using a ultrasonic thickness gauge to assess a loss of shielding integrity. The strains and accelerations acquired from tests were compared with those by analyses to verify the impact dynamic analysis. The analytic results were larger than the those of test so that the analysis showed the conservative results. Finally, we evaluated the safety of the type IP-2 transport package under the stacking test condition using a finite element analysis. Under the stacking test condition, the maximum Tresca stress of the shielding material was 1/3 of the yielding stress. Two kinds of a type IP-2 transport package were safe for the free drop test condition and the stacking test condition.

  • PDF

Evaluation on Usefulness of Applying Body-fix to Liver Cancer Patient in Tomotherapy (간암환자의 토모치료시 Body-fix 사용유무에 따른 유용성 평가)

  • Oh, Byeong-Cheon;Choi, Tae-Gu;Kim, Gi-Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.11-18
    • /
    • 2010
  • Purpose: In every time radiation therapy set up errors occur because internal anatomical organs move due to breathing and change of patient's position. These errors may affect the change of dose distribution between target area and normal structure. This study investigates the usefulness of body-fix in clinical treatment. Materials and Methods: Among 55~60 aged male patients who has hepatocellular carcinoma in area of liver's couinaud classification, we chose 10 patients and divided two groups by using body-fix or not. When applying body-fix, we maintained a vacuum of 80 mbar pressure by using vacuum pump (Medical intelligence, Germany). Patients had free breathing with supine position. After working to fuse and consist MV-CT (megavoltage computed tomography) with KV-CT (kilovoltage computed tomography) obtained by 5 times treatments, we compared and analyzed set up errors occurred to (Right to Left, RL) of X axis, (Anterioposterio, AP) of Z axis, (Cranicoudal, CC) of Y axis. Results: Average Set up errors through image fusion showed that group A moved $0.3{\pm}1.1\;mm$ (Cranicoudal, CC), $-1.1{\pm}0.7\;mm$ (Right to Left, RL), $-0.2{\pm}0.7\;mm$ (Anterioposterio, AP) and group B moved $0.62{\pm}1.94\;mm$ (Cranicoudal, CC), $-3.62{\pm}1.5\;mm$ (Right to Left, RL), $-0.22{\pm}1.2\;mm$ (Anterioposterio, AP). Deviations of X, Y and Z axis directions by applying body-fix indicated that maximum X axis was 5.5 mm, Y axis was 19.8 mm and Z axis was 3.2 mm. In relation to analysis of error directions, consistency doesn't exist for every patient but by using body-fix showed that the result of stable aspect in spite of changes of everyday's patient position and breathing. Conclusion: Using body-fix for liver cancer patient is considered effectively for tomotherapy. Because deviations between group A and B exist but they were stable and regular.

  • PDF

A study on the reduction on magnetic susceptible artifacts through the usage of silicon (실리콘을 이용한 자화율 인공물의 감소에 관한 연구)

  • Choi, Kwan-Woo;Lee, Ho-Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5937-5942
    • /
    • 2012
  • This study used silicon that is similar to the density of the tissue of the human body to compensate for the uneven areas that are in contact with air in order to reduce susceptible artifacts. The subjects of the study were 16 normal people and the areas of the human body in which there are a lot of uneven areas with complicated structure and a lot of susceptible artifacts were formed since the surface area that comes into contact with the air is large were the areas that were chosen to be examined. A 3.0T superconducting magnetic resonance device was used as the test equipment and SPIR images that are sensitive to magnetic differences were obtained as sagittal planes on a line that extended the metatarsal and the phalanges, including the middle of the longitudinal arc and the 5 distal phalanxes. The method of analysis was to reduce the susceptibility between the tissue and the air to discover the reduction of susceptible artifacts by comparing the SNR and CNR before and after applying silicon. A statistical analysis was utilized for the sample matching T examination. The results of the study revealed that the susceptible artifacts were reduced in the images of the uneven areas that were compensated and applied with silicon. The SNR increased in significant amount in correlation from $3.91{\pm}1.33$ before application to $21.69{\pm}4.52$ after application and the CNR decreased in significant amount in correlation from $28.97{\pm}8.20$ before application to $4.88{\pm}2.14$. In conclusion, this study did not affect the voxel but it was an innovative method of improvement that compensated for the fundamental issue of the difference in susceptibility between the air and the body. The application is simple and the study has great significance in that it proposed a method to reduce susceptible artifacts in a low cost and highly efficient manner.

Removal of Heavy Metal Ions in the Aqueous Solution Using Anodic Alumina and Retriculate Vitreous Carbon Electrodes (Anodic Alumina와 Retriculate Vitreous Carbon을 전극으로 사용하여 수용액에서 중금속이온의 제거)

  • Cho, Seung-Koo;Lee, Keon-Joo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.4
    • /
    • pp.120-129
    • /
    • 2003
  • The anodic alumina is synthesized using 0.3M oxalic acid and the barrier layers of the anodic alumina are removed using the 20wt% $H_2SO_4$ solution. The structure of the anodic alumina is analyzed by XRD and SEM. It is observed by SEM that the size of anodic alumina pore is about 60nm. And the uniformity of the anodic alumina surface under the 20wt% $H_2SO_4$ solution is poorer than the unifomity of the the normal anodic alumina surface. The anodic alumina and the carbon are used cathode and anode in$Cd(NO_3)_2{\cdot}4H_2O$, $Co(NO_3)_2{\cdot}6H_2O$ and $PbSO_4$ solutions. In this study, the constant D.C. electrical current is flowed in each solution for 24hours. It is found that the voltages so far as 4.6, 3.4 and 5.1V at $Cd(NO_3)_2{\cdot}4H_2O$, $Co(NO_3)_2{\cdot}6H_2O$ and $PbSO_4$ solutions increase with increasing the flowing current time and after the voltage does not change which values are 4.2, 2.7 and 2.4V, respectively. The amount of metal ions in solutions decrease with increasing the flowing current time until the flowing current time is 18hours and the metals are formed at the surface of anodic alumina. After the metal ions are removed using the anodic alumina, and $Cd^{2+}$, $Co^{2+}$ and $Pb^{2+}$ ions are removed again using flow cell with retriculate vitreous carbon(RVC) working electrode. The concentration of $Cd^{2+}$, and $Co^{2+}$ions decrease until the flowing time of the solutions is 20minutes and the concentration of $Pb^{2+}$ ion decreases until that time is 30minutes. In this case, the removal effects of $Cd^{2+}$, $Co^{2+}$ and $Pb^{2+}$ ions are 34.78, 28.79 and 86.38%, respectively. And it is possible that both $Cd^{2+}$ and $Co^{2+}$ions are adsorbed in pore of RVC at the same time and the removal effects of $Cd^{2+}$ and $Co^{2+}$ions are 32.30 and 31.37%.

  • PDF

Standardization and Reliability and Validity of the Korean Edition of Profile of Mood States(K-POMS) (한국판 기분상태척도(K-POMS)의 표준화와 신뢰도와 타당도 평가)

  • Kim, Eui-Joong;Lee, Sang-Ick;Jeong, Do-Un;Shin, Min-Sup;Yoon, In-Young
    • Sleep Medicine and Psychophysiology
    • /
    • v.10 no.1
    • /
    • pp.39-51
    • /
    • 2003
  • Objectives: The Profile of Mood States (POMS) has been used broadly and frequently in various medical studies with various subjects. For the development and application of the Korean edition of POMS, called K-POMS, we translated POMS into Korean and then evaluated the reliability and validity of K-POMS. Methods: The subjects were 161 male students with a mean age of 18.1 years (15-30) and 244 female students with a mean age of 16.6 years (14-23). They were requested to perform K-POMS and SCL-90-R (Korean version) at the same time. Means, reliability coefficients, and test-retest correlations of K-POMS were calculated. Content validities, correlations with SCL-90-R, and discrimination validities in comparison with 76 depressive patients were obtained, and factor analyses were carried out. Results: Mean scores of Total Mood Disturbance (TMD) and some subscales (T, F, C, V factor) showed a significant difference between male and female students. The internal consistency coefficient ($\alpha$) of the total 65 items was 0.93, and ranged from 0.67 to 0.90 for subscales. Test-retest correlations of 43 subjects ranged from 0.27 to 0.63. Seven psychiatrists rated the properness of the content of each item as more than moderate degree (mean scale points=2.66, in the range of 0 to 4). Every subscale of KPOMS exhibited significant correlation with the matching subscale of SCL-90-R. Mean scores of K-POMS of the total 405 subjects were significantly different from those of the 76 depressive subjects after age correction. Six factors were extracted, accounting for 51.2% of total variance. Factor 6 consisted of 6 items which came from various subscales of POMS and represented "uncertainty and helplessness," which may be somewhat different to depression or sadness proper. Conclusion: The validity and reliability of K-POMS could be confirmed. The significant difference in K-POMS scores between depressive subjects and normal subjects suggests that K-POMS can be used clinically for the evaluation and screening of depression. The main structure of K-POMS is very similar to that of POMS, except the Confusion-Bewilderment factor which shows weak factor consistency in K-POMS. This may reflect some emotional characteristic of Koreans such as an undifferentiated aspect of cognitive efficiency. The sixth factor newly extracted from K-POMS also may be indicative of an unique emotional aspect of young Koreans.

  • PDF

THE EFFECT OF ETCHING TIME ON THE PATTERN OF ACID ETCHING ON THE ENAMEL OF PRIMARY TEETH (산부식 시간에 따른 유전치 법랑질의 부식 유형에 관한 연구)

  • Choi, Su-Mi;Choi, Young-Chul;Park, Jae-Hong;Choi, Sung-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.437-445
    • /
    • 2008
  • The presence of a "prismless" layer on the enamel surface particularly on deciduous teeth has been reported by a number of workers. This structure, which appears to lack the normal prism delineations, could interfere with tag formation and hence, reduce bonding to such surfaces. The purpose of this study was to investigate the relationship of etching times on the effect of acid etching on primary enamel with respect to the quality of etching patterns. Labial surfaces of 32 extracted or exfoliated caries-free primary anterior teeth were used. 35% phosphoric acid gel was used only cervical regions of labial surfaces for each etching time group, 15, 30, 45 and 60 seconds. The surfaces were then washed with water for 20 seconds and dried with air spray for 20 seconds. 1. The Type 3 is 75% when the 15 seconds acid etching time was used. 2. The Type 1 is 38% and Type 2 is 75% when the 30 and 45 seconds acid etching time was used. 3. The Type 1 is 25% and Type 2 is 75% when the 60 seconds acid etching time was used. 4. An etching time of 60 seconds produced a constant and regular etching pattern. 5. There is a significant difference between the groups with respect to the patterns of etch achieved(p<0.05). 6. We confirmed that the acid induced patterns(type 1, 2) became more pronounced when the application time increased(p<0.05). $45{\sim}60$ seconds was the optimal time for etching on the primary enamel.

  • PDF