• Title/Summary/Keyword: normal sizes

Search Result 325, Processing Time 0.031 seconds

Voice therapy for pitch problems following thyroidectomy without laryngeal nerve injury (신경학적 손상이 없는 갑상선 술 후 음도문제의 음성치료)

  • Ji-sung Kim;Mi-jin Kim
    • Phonetics and Speech Sciences
    • /
    • v.15 no.3
    • /
    • pp.53-58
    • /
    • 2023
  • After thyroidectomy, some patients who show normal vocal cord movement still complain of subjective voice problems, which could lead to a decrease in quality of life related to communication. This study aims to investigate the effectiveness of a newly designed voice therapy applying neck exercise and semi-occluded vocal tract exercise (SOVTE) to improve voice problems after thyroidectomy without neurological injury. For this purpose, voice therapy was randomly assigned to 10 women who received thyroidectomy. Acoustic analysis [fundamental frequency, jitter, shimmer, noise-to-harmonics ratio, min Voice Range Profile (VRP), max VRP, VRP] was performed before and after surgery and immediately after voice therapy to compare voice changes. The study showed a statistically significant increase in max VRP and VRP after voice therapy compared to before surgery. These results suggest that the voice therapy methods in this study effectively improve a major symptom of voice problems after thyroidectomy, specifically the reduction in the high-frequency range. However, this study was limited in the number of s participants and did not control for the type of surgery. Therefore, further research utilizing larger sample sizes and controlled variables is needed to investigate the long-term effects of voice therapy.

Diagnosis of Unruptured Intracranial Aneurysms Using Proton-Density Magnetic Resonance Angiography: A Comparison With High-Resolution Time-of-Flight Magnetic Resonance Angiography

  • Pae Sun Suh;Seung Chai Jung;Hye Hyeon Moon;Yun Hwa Roh;Yunsun Song;Minjae Kim;Jungbok Lee;Keum Mi Choi
    • Korean Journal of Radiology
    • /
    • v.25 no.6
    • /
    • pp.575-588
    • /
    • 2024
  • Objective: Differentiating intracranial aneurysms from normal variants using CT angiography (CTA) or MR angiography (MRA) poses significant challenges. This study aimed to evaluate the efficacy of proton-density MRA (PD-MRA) compared to high-resolution time-of-flight MRA (HR-MRA) in diagnosing aneurysms among patients with indeterminate findings on conventional CTA or MRA. Materials and Methods: In this retrospective analysis, we included patients who underwent both PD-MRA and HR-MRA from August 2020 to July 2022 to assess lesions deemed indeterminate on prior conventional CTA or MRA examinations. Three experienced neuroradiologists independently reviewed the lesions using HR-MRA and PD-MRA with reconstructed voxel sizes of 0.253 mm3 or 0.23 mm3, respectively. A neurointerventionist established the gold standard with digital subtraction angiography. We compared the performance of HR-MRA, PD-MRA (0.253-mm3 voxel), and PD-MRA (0.23-mm3 voxel) in diagnosing aneurysms, both per lesion and per patient. The Fleiss kappa statistic was used to calculate inter-reader agreement. Results: The study involved 109 patients (average age 57.4 ± 11.0 years; male:female ratio, 11:98) with 141 indeterminate lesions. Of these, 78 lesions (55.3%) in 69 patients were confirmed as aneurysms by the reference standard. PD-MRA (0.253-mm3 voxel) exhibited significantly higher per-lesion diagnostic performance compared to HR-MRA across all three readers: sensitivity ranged from 87.2%-91.0% versus 66.7%-70.5%; specificity from 93.7%-96.8% versus 58.7%-68.3%; and accuracy from 90.8%-92.9% versus 63.8%-69.5% (P ≤ 0.003). Furthermore, PD-MRA (0.253-mm3 voxel) demonstrated significantly superior per-patient specificity and accuracy compared to HR-MRA across all evaluators (P ≤ 0.013). The diagnostic accuracy of PD-MRA (0.23-mm3 voxel) surpassed that of HR-MRA and was comparable to PD-MRA (0.253-mm3 voxel). The kappa values for inter-reader agreements were significantly higher in PD-MRA (0.820-0.938) than in HR-MRA (0.447-0.510). Conclusion: PD-MRA outperformed HR-MRA in diagnostic accuracy and demonstrated almost perfect inter-reader consistency in identifying intracranial aneurysms among patients with lesions initially indeterminate on CTA or MRA.

Characteristics of Pockmark Topography in Hupo Basin, East Sea (동해 후포분지의 Pockmark 해저지형 특성 연구)

  • Kim, ChangHwan;Park, ChanHong;Lee, MyoungHoon;Choi, SoonYoung;Kim, WonHyuck
    • Economic and Environmental Geology
    • /
    • v.52 no.6
    • /
    • pp.561-571
    • /
    • 2019
  • The Hupo Basin, continental marginal basin, of the East Sea extends to Uljin-gun and Yeongdeok-gun. The Hupo Bank, a terrain that is higher than the surrounding seabed, is located at the eastern boundary of the Hupo Basin. KIOST(Korea Institute of Ocean Science and Technology) conducted detailed bathymetry surveys in the northern, central and southern areas of the Hupo Basin from 2011 to 2013. The Hupo Basin, bounded by steep slopes of the Hupo Bank, is deepened from the west coast to the east and deepest to a maximum depth of about 250 m. A narrow seafloor channel appears in the northern, central, and southern areas with the deepest depths. Numerous pockmarks appear on the seafloor at depths of about 150 ~ 250 m in all the three areas of the detailed bathymetry surveys. These pockmarks generally have diameters of about 20 to 50 m and depths of about 4 to 6 m, with craterlike submarine topography of various sizes. Seafloor sediments in the pockmark areas consist of fine silt. Comparing the shape and size of the pockmark of the Hupo Basin with that of other regions of the world, it is considered to be classified as a normal pockmark. There are about 7 pockmarks/1 ㎢ in the northern part of the three areas and about 8 pockmarks/1 ㎢ in the central part. The southern part has about 5 pockmarks/1 ㎢. If the area with the possibility of pockmarks is extended to the depth area of about 150 ~ 250 m in the entire Hupo Basin, the number of pockmarks is estimated to be more than about 4800. The pockmark of the Hupo Basin is more likely to be generated by a fluid such as a liquid than a gas. But it is necessary to scrutinize the cause and continuously monitor the pockmark.

Experimental Studies on Cardiac Catecholamine Content (Catecholamines에 관(關)하여 -제삼편(第三編) 심장(心臟) Catecholamines에 관(關)한 실험적(實驗的) 연구(硏究)-)

  • Lee, Woo-Choo
    • The Korean Journal of Pharmacology
    • /
    • v.9 no.1
    • /
    • pp.1-21
    • /
    • 1973
  • During the last decade extensive studios on catecholamines have evolved new knowledge in the physiology and biochemistry of adrenergic mechanism. Cardiac muscle, receiving adrenergic fibres from the stellate, cervical and thoracic ganglia, has been repeatedly shown to have a specific capacity to uptake and to store catecholamines. The catecholamine stores in cardiac muscle have also been shown to be important sites for the action of numerous drugs. Under normal condition, a certain level of catecholamines is maintained in the stores and serves as the basis for studying the changes in the catecholamine content of the heart. Because myocardial catecholamines play such important role in the patho-physiology of the heart, it would be interesting to compare the normal level of myocardial catecholamines among various species of animals. An occasional study has dealt with myocardial catecholamines of several species add ages of animals but these have been insufficiently comprehensive to afford a basis for an understanding of the importance of these amines as related to species and ages. The present investigation was undertaken to determine whether or not there is any significance of myocardial catecholamines in the course of the evolution and development of animals. Seasonal changes, sex difference and regional and subcellular distribution of myocardial catecholamines were also examined. The concentration of cardiac catecholamines was determined by the spectrophotofluorometric procedure described by Shore and Olin. The results obtained were summarized as follows: 1. As animals phylogenetically progressed larger amounts of catecholamines were resent in their hearts. A negligibly small amount of catecholamine was present in the hearts of the clam, a non-vertebrate. Among the vertebrates, cold-blooded animals (snake, turtle, frog, eel and fish) had less myocardial catecholamines than warm-blooded animals, of which aves (fowl and duck) had less than mammalia (cat, dog, rabbit, rat, cow and pig). The ratio of norepinephrine to epinephrine also was greater as the animals progress phylogenetically. 2. Examination of the regional distribution of cardiac catecholamines in warm-blooded animals showed that the content of the auricle was generally higher than that of the septum and considerably than that of the ventricle, but the differences of contents among these regions were not so marked. 3. In the embryonic chick, cardiac catecholamines were firstly detected on the 4th day of incubation, the time before the cardiac innervation of sympathetic nerves. The concentrations of these catecholamines increased but not markedly on the 6th day of incubation, soon after the innervation of sympathetic nerves to the heart. The level of the cardiac catecholamines fluctuated throughout the remainder of embryonic development. 4. In newborn rat hearts, a considerable amount of catecholamines was present. With the development of the rats, the concentrations of myocardial catecholamines increased. The ratio of epinephrine and norepinephrine fluctuated within the range of 40 to 60 pervent. However, as development progressed, the percentage of norepinephrine continued to rise, attaining the adult value of $80{\sim}90%$ after $45{\sim}60$ days. In contrast, the total amount of epinephrine remained fairly constant throughout the animal's development. 5. No significant sexual differences were observed in the concentration of myocardial catecholamines in the developing rat. 6. The catecholamines in the rabbit hearts increased during the summer season (from May to August) and maintained a fairly constant level in the other seasons of the year. 7. The subcellular distribution of cardiac catecholamines was examined by differential centrifugation of homogenates of cardiac muscles in rabbits, cats and rats. The catecholamines were found to be present approximately 20% in particles of mitochondrial fraction, 45% in particles of microsomal fraction and 35% in soluble supernatant fraction. The particle containing catecholamines in cardiac muscle appears to be two different sizes.

  • PDF

Physioanatomical studies on mechanism in the process of becoming non-spinning silkworm(Bombyx mori) (토사불능잠의 출현기구에 관한 생리해부학적 연구)

  • 윤종관
    • Journal of Sericultural and Entomological Science
    • /
    • v.8
    • /
    • pp.41-50
    • /
    • 1968
  • In order to achieve efficiency of laying eggs of silkworms, it is very important to eliminate noncocooning silkworms. This study is written on the basis of observation and analysis of mechanism of silkworms physiologically and anatomically. It is hoped that given herein will contribute to the effecting elimination work. Outline of the study summarize as follows: 1. It is observed through microscope that the silkworms which are seen normal state in the silk gland but no ability of cocoon making have polyhedrosis in the nerve, trachea and muscle near the tissue of the spinneret. 2. Relatively high proportion of non-cocooning silkworms are caused by the grasserie of the silkworms. 3. As a result of inoculation with purulent discharges against silkworms from first fooding through 8th day of 5th instar, number of cocooning silkworms were increased when inoculation are applied at laterer day of the instar. In the case of non-cocooning silkworms, meanwhile, resulted not big varriation when it is apllied in the early and middle of the period, but number of non-cocooning silkworm was reduced when the inoculation are given at laterer of the instar. Number of death during rearing and mounting are increased when earliest application of inoculation are carried out. 4. Symptom of grasserie was appeared more or less three days after application of the inoculation. Some silkworms which were inoculated just before mounting has ability of cocooning making even taken grasserie, in this case the silkworm can make thin cocoon. since the silkworm fall sick during cocoon making and unable of spinning soon. when the worm was affected by grasserie slightly, it was observed that the silkworm can spinning. It is supposed to be the light paralysis of spinneret is not very much influenced to spinning. 5. As a result of observation of original stock and hybrid including other 44 kinds of silkworm, many non-cocooning silkworms were found in the original stock especially originated from japanese than in hybrid. 6. A number of undulations are found in the middle division of the silk gland of non-cocooning silkworms. 7. According to the observation of the sizes of the body and digestive organs, normal natured silkworms and non-cocooning silkworms are more or less same in length, but the width, circumference of bodies and digestive organs were more larger in the later. If silkworm which was in the period of active eating of 5th instar was given shock of dropping to the floor, the silkworm receives little more shock when hit to side of the body than to head, and concrete floor than ondol and wooden floor.

  • PDF

Evaluation of Metal Volume and Proton Dose Distribution Using MVCT for Head and Neck Proton Treatment Plan (두경부 양성자 치료계획 시 MVCT를 이용한 Metal Volume 평가 및 양성자 선량분포 평가)

  • Seo, Sung Gook;Kwon, Dong Yeol;Park, Se Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.25-32
    • /
    • 2019
  • Purpose: The size, shape, and volume of prosthetic appliance depend on the metal artifacts resulting from dental implant during head and neck treatment with radiation. This reduced the accuracy of contouring targets and surrounding normal tissues in radiation treatment plan. Therefore, the purpose of this study is to obtain the images of metal representing the size of tooth through MVCT, SMART-MAR CT and KVCT, evaluate the volumes, apply them into the proton therapy plan, and analyze the difference of dose distribution. Materials and Methods : Metal A ($0.5{\times}0.5{\times}0.5cm$), Metal B ($1{\times}1{\times}1cm$), and Metal C ($1{\times}2{\times}1cm$) similar in size to inlay, crown, and bridge taking the treatments used at the dentist's into account were made with Cerrobend ($9.64g/cm^3$). Metal was placed into the In House Head & Neck Phantom and by using CT Simulator (Discovery CT 590RT, GE, USA) the images of KVCT and SMART-MAR were obtained with slice thickness 1.25 mm. The images of MVCT were obtained in the same way with $RADIXACT^{(R)}$ Series (Accuracy $Precision^{(R)}$, USA). The images of metal obtained through MVCT, SMART-MAR CT, and KVCT were compared in both size of axis X, Y, and Z and volume based on the Autocontour Thresholds Raw Values from the computerized treatment planning equipment Pinnacle (Ver 9.10, Philips, Palo Alto, USA). The proton treatment plan (Ray station 5.1, RaySearch, USA) was set by fusing the contour of metal B ($1{\times}1{\times}1cm$) obtained from the above experiment by each CT into KVCT in order to compare the difference of dose distribution. Result: Referencing the actual sizes, it was appeared: Metal A (MVCT: 1.0 times, SMART-MAR CT: 1.84 times, and KVCT: 1.92 times), Metal B (MVCT: 1.02 times, SMART-MAR CT: 1.47 times, and KVCT: 1.82 times), and Metal C (MVCT: 1.0 times, SMART-MAR CT: 1.46 times, and KVCT: 1.66 times). MVCT was measured most similarly to the actual metal volume. As a result of measurement by applying the volume of metal B into proton treatment plan, the dose of $D_{99%}$ volume was measured as: MVCT: 3094 CcGE, SMART-MAR CT: 2902 CcGE, and KVCT: 2880 CcGE, against the reference 3082 CcGE Conclusion: Overall volume and axes X and Z were most identical to the actual sizes in MVCT and axis Y, which is in the superior-Inferior direction, was regular in length without differences in CT. The best dose distribution was shown in MVCT having similar size, shape, and volume of metal when treating head and neck protons. Thus it is thought that it would be very useful if the contour of prosthetic appliance using MVCT is applied into KVCT for proton treatment plan.

Regression of Left Ventricular Mass after Aortic Valve Replacement in Isolated Aortic Regurgitation (단독 대동맥판막 폐쇄부전 환자에서 대동맥판막 치환술 후 좌심실 질량의 변화)

  • Jung, Tae-Eun;Lee, Dong-Hyup;Lee, Seok-Soo
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.614-618
    • /
    • 2010
  • Background: The aim of our study was to assess the extent of regression of left ventricular mass after aortic valve replacement in isolated aortic regurgitation. Material and Method: Retrospective analysis of echocardiographic data was collected preoperative and postoperative 1 year. There were 20 patients (12 males, 8 females, mean age $55.8{\pm}11.8$ years, mean body surface area $1.64{\pm}0.19m^2$) with aortic regurgitation from 2002 through 2007. We studied the change of left ventricular ejection fraction, ventricular septum and left ventricular posterior wall thickness, and left vemtricular muscle index (LVMI). The control group was age matched with normal echocardiographic study results. Patients with combined surgery or infective endocarditis were excluded. Result: Seven cases of tissue valves and thirteen cases of mechanical valve were used. The valve sizes were 21 mm (3 cases), 23 mm (13 cases) and 25 mm (4 cases). The postoperative ($125.5{\pm}42g/m^2$) LVMI has decreased than preoperative LVMI ($212.3{\pm}80g/m^2$, p=0.000) but higher than that of control group ($80.5{\pm}15.9g/m^2$, p=0.000). Postoperative septal wall (systolic/diastolic: $13.5{\pm}3.4mm/17.1{\pm}4.1mm$) and left ventricular posterior wall (systolic/diastolic: $12.9{\pm}3.4mm/16.7{\pm}3.4mm$) thickness were slightly decreased after the valve replacement but was not significantly different than preoperative levels. And postoperative interventricular septal wall and left ventricular posterior wall thickness (systolic/diastolic: $8.6{\pm}1.4mm/12.1{\pm}1.7mm$, systolic/diastolic: $8.4{\pm}1.4mm/13.2{\pm}1.9mm$) were higher than that of the control group (p<0.001). Conclusion: The significant regression of LVMI after aortic valve replacement developed at postoperative one year but the level was higher than control group. The main cause of decreased LVMI is decreased in left ventricular dimension.

On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT) (콘빔CT (CBCT)를 이용한 온라인 영상유도방사선치료 (On-line Image Guided Radiation Therapy))

  • Bak, Jin-O;Jeong, Kyoung-Keun;Keum, Ki-Chang;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.294-299
    • /
    • 2006
  • $\underline{Purpose}$: Using cone beam CT, we can compare the position of the patients at the simulation and the treatment. In on-line image guided radiation therapy, one can utilize this compared data and correct the patient position before treatments. Using cone beam CT, we investigated the errors induced by setting up the patients when use only the markings on the patients' skin. $\underline{Materials\;and\;Methods}$: We obtained the data of three patients that received radiation therapy at the Department of Radiation Oncology in Chung-Ang University during August 2006 and October 2006. Just as normal radiation therapy, patients were aligned on the treatment couch after the simulation and treatment planning. Patients were aligned with lasers according to the marking on the skin that were marked at the simulation time and then cone beam CTs were obtained. Cone beam CTs were fused and compared with simulation CTs and the displacement vectors were calculated. Treatment couches were adjusted according to the displacement vector before treatments. After the treatment, positions were verified with kV X-ray (OBI system). $\underline{Results}$: In the case of head and neck patients, the average sizes of the setup error vectors, given by the cone beam CT, were 0.19 cm for the patient A and 0.18 cm for the patient B. The standard deviations were 0.15 cm and 0.21 cm, each. On the other hand, in the case of the pelvis patient, the average and the standard deviation were 0.37 cm and 0.1 cm. $\underline{Conclusion}$: Through the on-line IGRT using cone beam CT, we could correct the setup errors that could occur in the conventional radiotherapy. The importance of the on-line IGRT should be emphasized in the case of 3D conformal therapy and intensity-modulated radiotherapy, which have complex target shapes and steep dose gradients.

Clinical Evaluation of TightRope Cranial Cruciate Ligament Technique for Treatment of Cranial Cruciate Ligament Deficiency in Dogs (전방 십자인대 결손을 보이는 개에서 TightRope을 이용한 치료방법 평가)

  • Yoon, Hun-Young;Kim, Kyung-Hee;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.29 no.6
    • /
    • pp.455-459
    • /
    • 2012
  • Nine dogs presented to the Veterinary Medical Teaching Hospital of Konkuk University and Woosung Animal Hospital with a history of pelvic limb lameness. On physical examination, 9 dogs all showed a consistent weight bearing lameness and mild muscle atrophy. There was cranial drawer sign with pain in 9 dogs. Mediolateral radiographic projection revealed cranial subluxation of the tibial tuberosity in a tibial compression view. The right and left stifle joints were affected in 7 dogs and 2 dogs respectively. TightRope cranial cruciate ligament (CCL) technique for treatment of CCL deficiency was performed. Polyester and nylon were used to stabilize the stifle in 3 dogs and 6 dogs respectively. Suture sizes were 0.8 mm (n = 2), 0.9 mm (n = 4), 1.1 mm (n = 2), and $1.1mm{\times}2$ strands (n = 1) in diameter. Mean (${\pm}SD$) surgical duration was $48.3{\pm}8.5$ minutes (range 35 to 60 minutes). Preoperative and postoperative mean (${\pm}SD$) cranial drawer signs were $8.6{\pm}1.6$ mm (rage 7 to 12 mm) and $1.2{\pm}1.0$ mm (rage 0 to 3 mm) respectively. Immediate postoperative radiographs of the affected limb revealed no evidence of cranial subluxation of the tibial tuberosity in a tibial compression view of 9 dogs. Normal limb function was regained in 8 dogs within 8 weeks postoperatively. A consistent weight bearing lameness resolved in all dogs after TightRope CCL technique, but reoccurred in one dog (case No. 6) 2 weeks after surgery. Cranial subluxation of the tibial tuberosity was identified in a tibial compression test. During the second surgery, breakage of surgical button was identified and a tibial wedge osteotomy was performed. Based on surgical time, complication, stifle stability, and functional recovery, the present study indicated that TightRope CCL technique is effective treatment for the dogs with CCL deficiency.

Echocardiographic Parameters of Pulmonary Atresia with Intact Ventricular Septum(PA/IVS) (심실 중격 결손을 동반하지 않은 폐동맥 폐쇄 환아에서의 심초음파 계측치)

  • Lee, Young Seok;Kim, Yeo Hyang;Hyum, Myung Chul;Lee, Sang Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.5
    • /
    • pp.484-489
    • /
    • 2003
  • Purpose : To understand morphologic and hemodynamic variations in patients with pulmonary atresia with intact ventricular septum(PA/IVS), and to decide the best treatment modalities, we measured right ventricular volume, inflow, and outflow valvular annulus size in these patients and compared them with those of normal newborns. Methods : Eight patients with PA/IVS diagnosed by echocardiography from January to December 2001 were enrolled in this study. Among the total eight patients, five were male and three were female. The mean age of patients was 6.9 days(1-34 days), and the mean body weight was 3,343 gm (2,970-4,000 gm). Ten fullterm newborn infants with sepsis or hyperbilirubinemia without heart disease were enrolled as a control group. Echocardiographic and Doppler studies using Acuson Aspen (7Mh probe) were recorded on super-VHS videotape and later on, with review mode. We measured volumes of right and left ventricles, aortic, pulmonic, mitral and tricuspid valvular annulus sizes using an installed program, and then these parameters were compared with those of the control group. Results : Mean Z-value of tricuspid valvular annulus in PA/IVS was $-3.69{\pm}2.80$(-8.4--0.45), and tricuspid/mitral valvular annulus size ratio $0.68{\pm}0.15$(0.43--0.84). The more the tricuspid/mitral valvular annulus size ratio, the more Z-value of tricuspid valvular annulus(P=0.003, r=0.885). Those patients who underwent pulmonary valvuloplasty(balloon or surgical) had a tendency toward larger volume of the right ventricle, more Z-value of pulmonic and tricuspid valvular annulus, and more tricuspid/mitral valvular annulus size ratio than those patients who underwent a shunt operation. Conclusion : Compared to a measurement of the volume of the right ventricle, measurements of tricuspid/mitral valvular annulus size ratio and Z-value of tricuspid valvular annulus may be easier and better parameters to decide the treatment method and to predict prognosis in PA/IVS patients.