• Title/Summary/Keyword: normal resonance

Search Result 686, Processing Time 0.026 seconds

Effects on Normal Force and Input Voltage Variation in the Resonance Characteristics of an Ultrasonic Motor

  • Oh, Jin-Heon;Lim, Jong-Nam;Lee, Seung-Su
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.156-160
    • /
    • 2009
  • In an ultrasonic motor, a piezoelectric ceramic material forms the active element which vibrates the stator, thus initiating the rotational motion. In the operation of ultrasonic motors, many factors exist that can affect the resonance characteristics of the piezoelectric ceramic component. For examples, these factors are the bonding conditions with the piezoelectric element, the magnitude of the input voltage, the normal force in the frictional drive and the emission of heat due to vibration and friction etc. Therefore, it is important to research properly the inclination for variation of piezoelectric ceramics in the circumstance where complex elements are involved. In this paper, we focus on the analysis of the resonance characteristics of an ultrasonic motor as a function of the magnitude of the input voltage and the normal force.

Analysis on the cascade high power piezoelectric ultrasonic transducers

  • Lin, Shuyu;Xu, Jie
    • Smart Structures and Systems
    • /
    • v.21 no.2
    • /
    • pp.151-161
    • /
    • 2018
  • A new type of cascade sandwiched piezoelectric ultrasonic transducer is presented and studied. The cascade transducer is composed of two traditional longitudinally sandwiched piezoelectric transducers, which are connected together in series mechanically and in parallel electrically. Based on the analytical method, the electromechanical equivalent circuit of the cascade transducer is derived and the resonance/anti-resonance frequency equations are obtained. The impedance characteristics and the vibrational modes of the transducer are analyzed. By means of numerical method, the dependency of the resonance/anti-resonance frequency and the effective electromechanical coupling coefficient on the geometrical dimensions of the cascade transducer are studied and some interesting conclusions are obtained. Two prototypes of the cascade transducers are designed and made; the resonance/anti-resonance frequency is measured. It is shown that the analytical resonance/anti-resonance frequencies are in good agreement with the experimental results. It is expected that this kind of cascade transducer can be used in large power and high intensity ultrasonic applications, such as ultrasonic liquid processing, ultrasonic metal machining and ultrasonic welding and soldering.

The analysis of the resonance characteristics of a traveling wave type ultrasonic motor by applying the normal force and driving voltage (진행파 회전형 초음파 모터의 가압력과 구동전압에 따른 공진특성의 변화 분석)

  • Oh, Jin-Heon;Park, Cheol-Hyeon;Lim, Kee-Joe;Kim, Hyeon-Hoo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.324-324
    • /
    • 2008
  • Piezoelectric ceramics is an active element that makes stator to vibrate to generate rotational force in ultrasonic motors. In drive of ultrasonic motors, many factors that affect to the resonance characteristics of piezoelectric ceramics exist. For example, those factors are bonding condition with elastic body, the magnitude of electric field, the normal force for frictional drive and the emission of heat due to vibration and friction and so on. Therefore, it is important to research the inclination of property variation of piezoelectric ceramics in circumstance that has complex elements. In this paper, we focused and analyzed the resonance characteristics of ultrasonic motor due to the magnitude of the driving voltage and normal force.

  • PDF

Vibration reduction of the Engine Casing "B" deck in the handymax vessel (Handymax 급 PC 선 Engine Casing "B" deck 의 진동 저감)

  • Seo, Myung-Gab;Jeong, Tae-Seok;Seok, Ho-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.498-503
    • /
    • 2009
  • This paper presents the vibration problem of the Engine Casing (E/C) "B" deck in the handymax vessel and describes a method to avoid resonance. The first ship of the series did not have any vibration issue on the "B" deck. However, resonance condition occurred when additional machine was installed to the following vessels. To understand the dynamic characteristics of the deck, the normal mode analysis and impact test have been performed. Within the normal operating range of the vessel, the $1^{st}$ natural frequency of the E/C "B" deck is close to the main engine's $6^{th}$ order. Based on these analysis, a reinforcement on the deck was suggested and it proved to be effective. Since actual impact test after the reinforcement also confirmed the resonance avoidance.

  • PDF

Reproducibility of Hemispheric Language Dominance by Noun, Verb, Adjective and Adverb Generation Paradigms in Functional Magnetic Resonance Imaging of Normal Volunteers (정상성인의 뇌기능적 자기공명영상에서 명사, 동사, 형용사 그리고 부사 만들기 과제들에 대한 언어영역편재화의 재현성에 관한 연구)

  • In Chan Song;Kee Hyun Chang;Chun Kee Chung;Sang Hyun Lee;Moon Hee Han
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.24-32
    • /
    • 2001
  • Purpose : We investigated the reproducibility of language lateralization by 4 different word generation paradigms or the rest contents in each paradigm using functional magnetic resonance imaging in normal volunteers Materials and Methods Nine normal volunteers with left-handedness (mean age: 25 yrs) were examined on a 1.57 MR unit using a single-shot gradient echo epibold sequence. Four different word generation paradigms of noun, verb, adjective and adverb were used in each normal volunteer for investigating language system. In each paradigm, two different rest contents consisted of only seeing the " +" symbol or reading the meaningless letters. Each task consisted of 96 phases including 3 activations and 6 rests of 2 different contents. Two activation maps in one task were obtained under two different rest contents using the correlation method. We evaluated the detection rates of Broca and Wernicke areas and the differences of language lateralization among four different word generation paradigms, or between the rest contents. Results : The detection rates of Broca and Wernicke areas were over 67 % in 4 different language paradigms and there was no significant difference of them among language paradigms, or between two different rest contents. Language dominances, in all 4 different language paradigms, were shown to be consistent in 66 %, but were contrary with language paradigms in some subjects. The rest contents made no significant effect on dominant language dominance determination, but the success rates of the dominant language dominances determined from 4 language paradigms were higher in reading the meaningless letter (100%, n=9) than in only seeing "+" on screen at the rest task (78%, n=7).

  • PDF

Design Enhancement to Avoid Radar Mast Resonance in Large Ship using Design of Experiments (실험계획법을 이용한 대형 선박용 레이더 마스트의 공진회피 설계)

  • Park, Jun Hyeong;Lee, Daeyong;Yang, Jung-Wook;Song, Chang Yong
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.50-60
    • /
    • 2019
  • Recently, problems with excessive vibration of the radar masts of large bulk carriers and crude oil tankers have frequently been reported. This paper explores a design method to avoid the resonance of a radar mast installed on a large ship using various design of experiment (DOE) methods. A local vibration test was performed during an actual sea trial to determine the excitation sources of the vibration related to the resonant frequency of the radar mast. DOE methods such as the orthogonal array (OA) and Latin hypercube design (LHD) methods were used to analyze the Pareto effects on the radar mast vibration. In these DOE methods, the main vibration performances such as the natural frequency and weight of the radar mast were set as responses, while the shape and thickness of the main structural members of the radar mast were set as design factors. From the DOE-based Pareto effect results, we selected the significant structural members with the greatest influence on the vibration characteristics of the radar mast. Full factorial design (FFD) was applied to verify the Pareto effect results of the OA and LHD methods. The design of the main structural members of the radar mast to avoid resonance was reviewed, and a normal mode analysis was performed for each design using the finite element method. Based on the results of this normal mode analysis, we selected a design case that could avoid the resonance from the major excitation sources. In addition, a modal test was performed on the determined design to verify the normal mode analysis results.

How Computed Tomography Contrast Media and Magnetic Resonance Imaging Contrast Media Affect the Changes of Uptake Counts of 201Tl

  • Lee, Jin-Hyeok;Lee, Hae-Kag;Cho, Jae-Hwan;Cheon, Miju
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.372-377
    • /
    • 2014
  • The purpose of the study is to investigate how uptake counts of $^{201}Tl$ of radioisotopes in the human body could change, when taking computed tomography and magnetic resonance imaging right after injecting contrast media. $^{201}Tl$ radioisotope substances of iodine contrast medium, which is a computed tomography contrast medium, and paramagnetic contrast medium, which is an magnetic resonance imaging contrast medium, were used as study materials. First, $^{201}Tl$ was put into 4 cc of normal saline in test tube, and then a computed tomography contrast medium of Iopamidol$^{(R)}$ or Dotarem$^{(R)}$, was put into 2 cc of normal saline in test tube. An magnetic resonance imaging contrast medium of Primovist$^{(R)}$ or Gadovist$^{(R)}$ was also put into 2 cc of normal saline in test tube. Each contrast medium was distributed to make $^{201}Tl$ as 3 mCi, with a total of 4 cc. Gamma camera, low energy high resolution collimator, and pinhole collimator were used to obtain images. The uptake count of $^{201}Tl$ was measured with 1000 frames of images, and obtained after 10 times of repetition. This study revealed that the use of Gadovist$^{(R)}$, which is an magnetic resonance imaging contrast medium, showed the smallest number of uptake count, after measuring $^{201}Tl$ uptake count by low energy high resolution collimator. On the other hand, the use of Iopamidol$^{(R)}$, which is a computed tomography contrast medium, showed the biggest difference in uptake count, when measuring $^{99m}Tc$ uptake count by Pinhole collimator. When examining with gamma camera, using contrast medium and $^{201}Tl$, identifying the changes of uptake count is very important for improving the value of diagnosis.

Magnetic Resonance Imaging Comparison of Intervertebral Disc Degeneration of Normal and Disc Diseases in Dogs

  • Jin-Su Mok;Seul Ah Noh;Young-min Yoon;Tae Sung Hwang;Hee Chun Lee
    • Journal of Veterinary Clinics
    • /
    • v.40 no.1
    • /
    • pp.38-43
    • /
    • 2023
  • This study compared the degree of disc degeneration of intervertebral disc between normal disc and disc disease using Magnetic Resonance images of tholacolumbar and lumbar vertebrae in dogs. The sample population consisted of 72 dogs and 188 intervertebral discs. These dogs were divided into four groups according to MRI criteria: normal, disc protrusion, disc extrusion, and fibrocartilaginous embolism. The Pfirrmann classification developed by Pfirrmann for use in human medicine was used to assess the degree of disc degeneration. Statistical analysis revealed that disc diseases had a significant difference in the degree of disc degeneration compared to normal discs in the intervertebral disc. Fibrocartilaginous embolism was found to have a relatively low disc degenerative change compared to two other disc disease groups, disc protrusion and disc extrusion. Disc degeneration in the disc extrusion group was slightly higher than that in the disc protrusion group, although the difference between the two groups was not statistically significant.

The Fornix: Functional Anatomy, Normal Neuroimaging, and Various Pathological Conditions

  • Choi, Young Jae;Lee, Eun Ja;Lee, Jung Eun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.2
    • /
    • pp.59-75
    • /
    • 2021
  • The fornix is the major white-matter outflow tract from the hippocampus; it has a significant role in cognitive function. It is readily imaged via magnetic resonance imaging; its main parts are the crura, commissure, body, and columns. In this pictorial essay, we describe and illustrate the functional and imaging anatomy of the fornix and limbic system, as well as various disease entities involving the fornix.

Internal Resonance and Stability Change for the Two Degree Nonlinear Coupled System (2 자유도 비선형 연성시스템에서 내부공진과 안정성 변화)

  • Kim, Myoung-Gu;Pak, Chul-Hui;Cho, Chong-Du
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.853-861
    • /
    • 2007
  • To understand the concept of dynamic motion in two degree nonlinear coupled system, free vibration not including damping and excitation is investigated with the concept of nonlinear normal mode. Stability analysis of a coupled system is conducted, and the theoretical analysis performed for the bifurcation phenomenon in the system. Bifurcation point is estimated using harmonic balance method. When the bifurcation occurs, the saddle point is always found on Poincare's map. Nonlinear phenomenon result in amplitude modulation near the saddle point and the internal resonance in the system making continuous interchange of energy. If the bifurcation in the normal mode is local, the motion remains stable for a long time even when the total energy is increased in the system. On the other hand, if the bifurcation is global, the motion in the normal mode disappears into the chaos range as the range becomes gradually large.

  • PDF