• Title/Summary/Keyword: normal operation state

Search Result 172, Processing Time 0.024 seconds

Design of a 60 Hz Band Rejection FilterInsensitive to Component Tolerances (부품 허용 오차에 둔감한 60Hz 대역 억제 필터 설계)

  • Cheon, Jimin
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.2
    • /
    • pp.109-116
    • /
    • 2022
  • In this paper, we propose a band rejection filter (BRF) with a state variable filter (SVF) structure to effectively remove the influence of 60 Hz line frequency noise introduced into the sensor system. The conventional BRF of the SVF structure uses an additional operational amplifier (OPAMP) to add a low pass filter (LPF) output and a high pass filter (HPF) output or an input signal and a band pass filter. Therefore, the notch frequency and the notch depth that determine the signal attenuation of the BRF greatly depend on the tolerance of the resistors used to obtain the sum or difference of the signals. On the other hand, in the proposed BRF, since the BRF output is formed naturally within the SVF structure, there is no need for a combination between each port. The notch frequency of the proposed BRF is 59.99 Hz, and it can be confirmed that it is not affected at all by the tolerance of the resistor through the Monte Carlo simulation results. The notch depth also has an average of -42.54dB and a standard deviation of 0.63dB, confirming that normal operation as a BRF is possible. Also, with the proposed BRF, noise filtering was applied to the electrocardiogram (ECG) signal that interfered with 60 Hz noise, and it was confirmed that the 60 Hz noise was appropriately suppressed.

Hysteresis Characteristics of Flux-Lock Reactor using HTSC (고온초전도체를 이용한 자속구속 리액터의 히스테리시스 특성)

  • Lim, Sung-Hun;Choi, Hyo-Sang;Ko, Seok-Cheol;Lee, Jong-Hwa;Park, Sick;Kang, Hyeong-Gon;Han, Byoung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.89-91
    • /
    • 2003
  • For the design to prevent the saturation of iron core and the effective fault current limitation, the analysis for the operation of the flux-lock type superconducting fault current limiter (SFCL) with consideration for the hysteresis characteristics of iron core is required. In this paper, the hysteresis characteristics of flux-lock reactor, which is an essential component of flux-lock type SFCL, was investigated. The hysteresis loss of iron core in flux-lock type SFCL does not happen due to its winding's structure especially in the normal state. From the equivalent circuit for the flux-lock type SFCL and the fault current limiting experiments, the hysteresis curves could be drawn. Through the analysis for both the hysteresis curves and the fault current limiting characteristics due to the number of turns for the 1st and 2nd winding, the increase of the number of turns in the 2nd winding of the flux-lock type SFCL had a role to prevent the iron core from saturation.

  • PDF

Pre- and Postoperative Changes of Serum Levels of Slpha 1-proteinase Inhibitor in Patients with Bronchogenic Cancer (폐암 환자에서의 폐엽절제술 전후의 혈청 Alpha 1-Proteinase Inhibitor의 변화)

  • 이재성
    • Journal of Chest Surgery
    • /
    • v.28 no.3
    • /
    • pp.221-227
    • /
    • 1995
  • Malignancy is one of the several exogenous and endogenous factors that increase serum alpha 1-PI. In fact, serum levels of alpha 1-PI were significantly elevated in the patients with the nonresectable bronchogenic cancer. the purpose of this work was to determine if the immediate postoperative change of serum alpha 1-PI level following tumor resection relates to the patient`s postoperative course. Clinical experimental study was carried out to investigate the postoperative changes of serum alpha 1-PI level following operation for 20 cases of bronchogenic cancer and 10 cases of control, nephrectomy patients Alpha 1-PI concentrations in serum was quantitated by use of radial immunodiffusion technique.The results were as follows ; Preoperative serum level of alpha 1-PI was significantly elevated in patients with bronchogenic cancers [p < 0.001 , when compared to normal control levels. Immediate postoperative serum alpha 1-PI level was significantly increased in patients with bronchogenic cancer [p < 0.05 , but slightly decreased at control groups. The peak serum level of alpha 1-PI was the postoperative three days, and then gradually decreased at the 5, 9, 14 days, but slightly elevated comparing to preoperative alpha 1-PI levels. Serum alpha 1-PI level in patients with adenocarcinoma was elevated, when compared to squamous cell carcinoma, but not significantly. According to the stages of the bronchogenic cancer, each levels of the serum alpha 1-PI were slightly different, but the whole postoperative changes were the general similarity. There were no significant difference in changes of the serum alpha 1-PI level, according to the operative procedures. As the alpha 1-PI is acute reactant, that it was required at the reoperative state of the bronchogenic cancer and rapid response, consumption or requirement were occurred, postoperatively. Therefore, alpha 1-PI can be perioperative indicator for the evaluation of the bronchogenic cancer.

  • PDF

AN EXPERIMENTAL STUDY ON THE EFFECT OF ACID ETCHING OF DENTINE TO PULP TISSUE (상아질(象牙質)의 산부식(酸腐蝕)이 치수조직(齒髓組織)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Chung, Se-Joon;Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.1
    • /
    • pp.41-52
    • /
    • 1988
  • The purpose of this study was to investigate the pulpal responses to acid etching of dentine. Total 72 class V cavaties' were prepared on the healthy permanent teeth from 6 dogs, and were divided into 4 groups. These were filled with filling materials after acid etching with each etchant for 1 min. Control group ; ZOE filling without acid etching. Group 1: Zinc Oxide-Eugenol cement filling. Group 2: Drying with hot air and Zinc oxide-Eugenol cement filling. Group 3: Scotchbond application and silux filling. Group 4: Silux filling. The dogs were sacrificed after 1 week, 2 weeks, 3 weeks, 4 weeks, 5 weeks and 6 weeks following operation. The specimens were routinely prepared and stained with Hematoxylin and Eosin. Followings were the results obtained through microscopic examination. 1. There was mostly severe pulpal responses in case of Silux filling after acid etching of dentine. 2. The pulpal responses of Silux filling after acid etching and application of Scotch bond group were more severe compared to Zinc Oxide-Eugenol cement filling group, but less severe compared to Silux filling group after acid etching of dentine. 3. The pulpal responses of Zinc Oxide-Eugenol cement filling group were similar to those of Zinc Oxide-Eugenol cement filling after drying with hot air group. 4. There was slight pulpal responses in early stage in case of Zinc Oxide-Eugenol cement filling group, but recovered to normal state soon after.

  • PDF

Real-time measurement management system UI development linked the Water treatment facilities Broadband Convergence Network (수처리시설용 광대역 통합망 연계형 실시간 계측 관리 시스템 UI개발)

  • Yang, Seungyoun;Kim, Jintae;Oh, Hwanjin;Lee, Minwoo
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.4
    • /
    • pp.83-86
    • /
    • 2015
  • In this paper, we propose a real-tim measurement management system UI development linked the Water treatment facilities broadband Convergence Network. The sensor and the image data received by the server develop a program to interact with Web through water treatment facilities broadband convergence network. So, Separately develop UI capable of independently operating. Building a web server for remote monitoring of the transmission sensor and the image data. And Monitoring and control is possible the sensor data and image data through the Web-based UI. We can grasp the current state such as measurement time, concentration and depth of interface through the proposed real-time measurement management system UI development liked the water treatment facilities broadband convergence network. So, we can check in whether the normal operation of water treatment facilities and whether the casualties such as fire and security. As well as real time to see the information at a glance due to UI development can be raal-time monitoring of real-time measurement management system.

The Study on the Temperature Compensation of Ultrasonic Motor for Robot Actuator Using Fuzzy Controller (퍼지제어기를 이용한 로보트 액츄에이터용 초음파 모터의 온도 보상에 관한 연구)

  • 차인수;유권종;백형래;김영동
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.165-172
    • /
    • 1998
  • The electromechanical energy conversion conditioning and processing implementation in USM direct motion control system is generally divided into two power stages: the two-phase high-frequency ac power inversion stage for driving piezoelectric ceramic PZT transducer array off the USM stator and the mechanical thrust power conversion stage based on the frictional force between the piezo electric stator array and the rotary slider of the USM. However, the dynamic and steady-state mathematical modeling of the USM is extremely default from a theoretical point of view because it contains many complicated an nonlinear characteristics dependant on operation temperature. In +2$0^{\circ}C$~3$0^{\circ}C$, the operating characteristics of the USM has represented normal condition. But the other temperature, it has abnormal condition so that driving frequency, current and motor speed will be down. The recent USM has controller without temperature compensation. This study represents the fuzzy controller for speed compensation according to operating temperature by driving frequency.

Therapeutic monitoring of vancomycin according to initial dosing regimen in pediatric patients

  • Kim, Dae-Il;Im, Mi-Sun;Choi, Jin-Hyoung;Lee, Jin-A;Choi, Eun Hwa;Lee, Hoan-Jong
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.12
    • /
    • pp.1000-1005
    • /
    • 2010
  • Purpose: This study aimed to determine the optimal initial vancomycin dose to achieve appropriate trough levels in pediatric patients. Methods: We analyzed clinical data for 309 children treated with intravenous vancomycin between 2004 and 2009 at 2 different hospitals in South Korea. The patients were 1-16 years old and exhibited normal renal function. Patient data, including reason for treatment and initial dosing regimen, were reviewed. Two subgroups were identified and compared according to initial vancomycin dose: 40 (35-45) mg/kg/day and 60 (55-65) mg/kg/day. Trough levels were obtained at steady state after at least 4 doses of vancomycin. Results: Patients who received vancomycin had post-operation or wound-related infections (37.2%), localized infection (12.9%), catheter-related infections (9.4%), meningitis (8.7%), or endocarditis (6.8%). Pathogens were confirmed in 79 cases: 28 cases of methicillin-resistant $Staphylococcus$ $epidermidis$ (35.4%) and 25 of methicillin-resistant $Staphylococcus$ $aureus$ (31.6%). Out of the 309 patients, 201 (65%) received vancomycin at 40 mg/kg/day and 108 (35%) at 60 mg/kg/day. Average trough concentrations were significantly different between the groups ($P$<0.001). Trough levels over 10 mg/L were less likely to be achieved in the 40 mg/kg/day group (14%) than in the 60 mg/kg/day group (49%) ($P$<0.001). There were no differences in renal function deterioration between the groups. Conclusion: A common vancomycin dosing regimen, 40 mg/kg/day, was not high enough to achieve trough levels of over 10 mg/L in pediatric patients. Careful drug monitoring must be performed, and increasing initial dose of vancomycin should be considered in pediatric patients.

Validation of Computational Fluid Dynamics Calculation Using Rossendorf Coolant Mixing Model Flow Measurements in Primary Loop of Coolant in a Pressurized Water Reactor Model

  • Farkas, Istvan;Hutli, Ezddin;Farkas, Tatiana;Takacs, Antal;Guba, Attila;Toth, Ivan
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.941-951
    • /
    • 2016
  • The aim of this work is to simulate the thermohydraulic consequences of a main steam line break and to compare the obtained results with Rossendorf Coolant Mixing Model (ROCOM) 1.1 experimental results. The objective is to utilize data from steady-state mixing experiments and computational fluid dynamics (CFD) calculations to determine the flow distribution and the effect of thermal mixing phenomena in the primary loops for the improvement of normal operation conditions and structural integrity assessment of pressurized water reactors. The numerical model of ROCOM was developed using the FLUENT code. The positions of the inlet and outlet boundary conditions and the distribution of detailed velocity/turbulence parameters were determined by preliminary calculations. The temperature fields of transient calculation were averaged in time and compared with time-averaged experimental data. The perforated barrel under the core inlet homogenizes the flow, and therefore, a uniform temperature distribution is formed in the pressure vessel bottom. The calculated and measured values of lowest temperature were equal. The inlet temperature is an essential parameter for safety assessment. The calculation predicts precisely the experimental results at the core inlet central region. CFD results showed a good agreement (both qualitatively and quantitatively) with experimental results.

A study on the Compliance and Educational Demand of Renal Transplantation Patient (신장이식 환자의 치료지시 이행정도와 교육 요구도에 관한 연구)

  • Ryu, Jeong-Ha;Kim, Myung-Hee;Kang, In-Soon
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.6 no.2
    • /
    • pp.226-238
    • /
    • 2003
  • This study was started for the purpose of providing the basic data for continous managment of kidney transplantation patients after discharge. This study was conducted on 180 patients who received renal transplants at three hospital( B, M, P) pusan, korea. The data collection was done for june 1, to August 31, 2002. General characteristics, renal transplantaton characteristics, physical characteristics, the level of compliance and the degree of educational demand were done by the number and percentage, the mean, standard deviation. The level of compliance and educational demand followed by the characteristics of general and kidney transplantation were analyzed by t-test and ANOVA. The result were as fallows; 1. Man was higher than woman such as 60.0%, Mean age was 42.5 years old, Average total duration of after operation was 5.5 years. 2. Cases of systolic blood pressure over 140mmHg were 10.0%, cases of diastolic blood pressure over 90mmHg were 22.8% and obesity factor in BMI was 15.6%. The person who daily water intake amount is 5000cc was 0.6%, the case that daily urine output is below 1000cc was 8.9%, and the case that urine output is zero was 0.6%. 3. The mean score of compliance was 77.47 point, The score in medication part was highest such as 4.67 point, that in stress situation was lowest such as 3.50 point. 4. The average score of educational demand was 154.02 point, and physical state part was 4.36 points highest, activation part was 3.48 points lowest. As a role of nurse Confirmation of compliance is very important encourage to make good through regular hospital visitation, point out the noncompliance part and then increase compliance of renal transplantation patient As well there will be maintain the normal kidney function to satisfy educational demand through continous education.

  • PDF

ICCP Control and Monitoring System for Ships

  • Oh, Jin-Seok;Moon, Serng-Bae
    • Journal of Navigation and Port Research
    • /
    • v.30 no.4
    • /
    • pp.291-294
    • /
    • 2006
  • Corrosion is never avoided in the use rf materials with various environments. The underwater hull is normally protected against rusting by several coatings of anti-corrosive paint. The purpose of ICCP(Impressed Current Cathodic Protection) system is to eliminate the rusting or corrosion, which occurs on metal immersed in seawater. This thesis is about the ICCP control and monitoring system, which brings protection against the corrosion of the ship's hull in the sea environments. The test system for ICCP is composed of a power supply, anode, reference electrode and controller. The test system is composed power supply, anode, ref electrode, shunt and etc. The protection current is sent to the protection area though anode. Reference electrode senses whether or not the detected potential is within a range of protection of test equipment and then it is automatically controlled to increase or decrease the amount of protective current to be sent to the anode by controller. The monitoring system with LabView is also detected in order to check the normal state of the system at operation period, because an operator does not always watch over this system and thus the system cannot operate well because rf his or her negligent management. This paper was studied the variation of potential and current density with environment factors, velocity and time, and the experimental results will be explained Also, It is suggested that this system can accommodate a ship's automation for SCMS(Ship Control and Management System) and will be very useful.