• Title/Summary/Keyword: normal measurement

Search Result 1,798, Processing Time 0.028 seconds

Sliding Frictional Characteristics with the Change of Dynamic Parameters in the Friction Measurement (마찰시험기의 시스템 동적변수 변화에 따른 미끄럼마찰 특성)

  • 공호성;윤의성;권오관;오재응
    • Tribology and Lubricants
    • /
    • v.11 no.2
    • /
    • pp.44-55
    • /
    • 1995
  • Frictional characteristics with the change of dynamic parameters, such as stiffness, inertia and damping, in the friction measurement at dry sliding surfaces were experimentally and theoretically investigated throughout the study. Dynamic frictional force and the variation in the normal load were mainly measured at the various conditions of system dynamic parameters with which stiffness in the normal direction, loading mechanisms and test materials were varied. For the normal load, mechanisms using both a dead weight and a pneumatic cylinder were applied, which resulted in change of the inertia and damping of the test rig. Test materials were steel, rosin and PTFE, which have different types of intrinsic frictional characteristics. Test results showed that frictional characteristics under different dynamic parameters could be different even though the operating variables were the same and also they could result in the variation in the normal load, which could consequently affect the wear mechanism.

A Study on Taguchi's Feed-back Control System (다구찌의 피드백 제어 시스템에 관한 연구)

  • 김지훈;정해성;김재주
    • Journal of Korean Society for Quality Management
    • /
    • v.26 no.3
    • /
    • pp.60-70
    • /
    • 1998
  • When driving the expected loss generated by the quality deviation, Taguchi(1991b) assumed that an objective characteristic has the uniform distribution in its control limit. But it is reasonable to assume that an objective characteristic has the normal distribution than the uniform distribution. Since the triangular distribution is similar to the normal distribution and easy to handle as well, in this article, we first find the optimum measurement interval and the optimum control limit under the triangular distribution. Under the normal assumption, the modified method is compared to Taguchi's. Secondly we find the numerical value solution of the optimum measurement interval and the optimum control limit under the normal distribution.

  • PDF

A Study on the Influence of Wearing-Girdle on the Various Physiological Function (Girdle 착용이 신체 제 기능에 미치는 영향에 관한 연구)

  • 박영득
    • Journal of the Korean Home Economics Association
    • /
    • v.28 no.1
    • /
    • pp.1-7
    • /
    • 1990
  • This study was carried out to investigate the influence of the various physiological function caused by girdle wearing. The four experimental methods used in this study are as follows. For example, the Reentgen photographing, body measurement by Sliding Gauge, mensurement of the electrocardiogram, measurement of the pulse and the blood pressure. The results of the investigation were as follows; 1. In the change of the various organs by Roentgen photographing, the diaphragm rised a little than normal position. The heart and stomach inclined to right side and the shape of stomach and duodenum are longer than the length of normal shape. Especially the phlorus of stomach was pressured strongly. 2. In the experimental change by the Sliding gauge and body measurement, the waist, hip and theigh girth of wearing-girdle reduced than at the no-girdle. The protruson of abdomen and hip section of wearing-girdle and the phenomenon of Hip-Up showed. 3. The difference by measurement of the electrocardiogram wasn't showed. The pulse of the wearing-girdle was increased slightly than the no-girdle. 4. The blood pressure of the wearing-girdle decreased slightly than the no-girdle.

  • PDF

A Comparative Study for Several Bayesian Estimators Under Balanced Loss Function

  • Kim, Yeong-Hwa
    • Journal of the Korean Data and Information Science Society
    • /
    • v.17 no.2
    • /
    • pp.291-300
    • /
    • 2006
  • In this research, the performance of widely used Bayesian estimators such as Bayes estimator, empirical Bayes estimator, constrained Bayes estimator and constrained empirical Bayes estimator are compared by means of a measurement under balanced loss function for the typical normal-normal situation. The proposed measurement is a weighted sum of the precisions of first and second moments. As a result, one can gets the criterion according to the size of prior variance against the population variance.

  • PDF

A Comparative Study for Several Bayesian Estimators Under Squared Error Loss Function

  • Kim, Yeong-Hwa
    • Journal of the Korean Data and Information Science Society
    • /
    • v.16 no.2
    • /
    • pp.371-382
    • /
    • 2005
  • The paper compares the performance of some widely used Bayesian estimators such as Bayes estimator, empirical Bayes estimator, constrained Bayes estimator and constrained Bayes estimator by means of a new measurement under squared error loss function for the typical normal-normal situation. The proposed measurement is a weighted sum of the precisions of first and second moments. As a result, one can gets the criterion according to the size of prior variance against the population variance.

  • PDF

Fitness Measurement system using deep learning-based pose recognition (딥러닝 기반 포즈인식을 이용한 체력측정 시스템)

  • Kim, Hyeong-gyun;Hong, Ho-Pyo;Kim, Yong-ho
    • Journal of Digital Convergence
    • /
    • v.18 no.12
    • /
    • pp.97-103
    • /
    • 2020
  • The proposed system is composed of two parts, an AI physical fitness measurement part and an AI physical fitness management part. In the AI fitness measurement part, a guide to physical fitness measurement and accurate calculation of the measured value are performed through deep learning-based pose recognition. Based on these measurements, the AI fitness management part designs personalized exercise programs and provides them to dedicated smart applications. To guide the measurement posture, the posture of the subject to be measured is photographed through a webcam and the skeleton line is extracted. Next, the skeletal line of the learned preparation posture is compared with the extracted skeletal line to determine whether or not it is normal, and voice guidance is provided to maintain the normal posture.

A New Method of Liver Size Estimation on Hepatic Scintigram -Hepato-abdominal Ratio (간신티그램상 간크기의 새로운 평가방법 -간.복부횡경비-)

  • Yang, Il-Kwon;Yoon, Sung-Do;Park, Seog-Hee;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.16 no.2
    • /
    • pp.25-28
    • /
    • 1982
  • Estimation of liver size is essential in the diagnosis of liver disease, Many approaches have been attempted in evaluation of liver size such as the measurement of length, area and volume. Among these, area and volume measurements are accurate but complicated, so we commonly use formerly introduced various linear measurements, but in scintigraphy one must calculate the actual liver size using rate of reduction, which is time consuming. Because of these reasons, we carried out present study to represent liver size by means of a simple liver measurement like we express the cardiac size by cardiothoracic ratio. Our cases consisted of 100 clinically normal subjects as the normal group and 50 patients suffering from liver disease and diagnosed to have hepatomegaly on abdominal palpation and scintigram at Dept, of Radiology of St. Mary's Hospital, Catholic Medical College during the period of 8 months from Jan. 1980. We measured the liver size using 4 linear diameters(Fig. 1). And as the reference measurement, the distance from the right margin of the liver to the left margin of the spleen was measured. We called this "abdominal transverse diameter(ATD)". The results were as follows; 1) The smallest value was recorded in the midline vertical diameter (MVD). It was $4.2{\pm}0.4cm$ in normal group and $5.0{\pm}0.6cm$ in the hepatomegaly group. 2) The diameter using other methods ranged from 5.6 to 7.2 cm in the normal group and from 6.3 to 7.5cm in the hepatomegaly group. 3) There was significant difference in the ratio of each diameter to ATD between the normal and hepatomegaly group (<0.01). We called this "hepato-abdominal ratio". 4) The "hepato-abdominal ratio" using MVD is $0.43{\pm}0.06$ in the normal group and $0.53{\pm}0.07$ in the hepatomegaly group. The "hepato-abdominal ratio" of MVD was most significantly different between normal and hepatomegaly group. 5) The tolerance limits(99%) of "hepato-abdominal ratio" using MVD is from 0.41 to 0.45 in the normal group and from 0.51 to 0.55 in the hepatomegaly group. Therefore, by reasons of error during measurement and convenience of memory, it was warranted to suggest hepatomegaly when "hepato-abdominal ratio" using MVD is more than 0.5 in the interpretation of hepatic scintigram.

  • PDF

New Standards for Measurement in Meridians & Acupoints by Taking the Size of Normal Male Legs (정상 성인 남자(男子) 하지부위(下肢部位)의 수혈(?穴) 정위(定位)를 위한 도량형(度量衡) 산출)

  • Yu, Shin-Jong;Kwon, Oh-Sang;Ahn, Seong-Hoon;Kim, Young-Jin;Kim, Kyung-Sik;Sohn, In-Chul;Kim, Jae-Hyo
    • Journal of Pharmacopuncture
    • /
    • v.13 no.1
    • /
    • pp.93-101
    • /
    • 2010
  • Objective : Standard of measurement in Korean Medicine has been changed in dynasty and location. Thus, cun (寸) and chi (尺) as unit of measurement for meridians and acupoints could be recognized as the length of equally divided portions of a certain long bone or the distance between two anatomical landmarks and as an symbolical meaning to date. The goal of this study is to propose a new standard measurement in the metric system for the relative measurement of cun and chi as unit of measurement for meridians and acupoints in normal male legs. Methods : This study was conducted by gauging each parts of normal male legs in the metric system and comparing to the relative measurement of cun and chi as follows; to calculate 1 cun, the length of each parts was divided into the unit of cun referred to Measurement of the Bone in Neijing Lingshu (靈樞 骨度篇); it was compared the unit of cun referred to Measurement of the Bone in Neijing Lingshu with cun which was calculated by dividing subject's height into 75 cun, respectively. Result : There has no significant difference in length of 1 cun among each leg's areas based on a standard of subject's height. The unit of cun by the metric length in the legs was similar to the unit of cun referred to Measurement of the Bone in Neijing Lingshu based on each subject's height. Conclusion : It is suggested that an unit of cun as the measurement for meridians and acupoints in the male legs should be considered to the ranges from 2.4cm to 2.6cm.

Comparison of the capsular width measured on ultrasonogrape and MR image of the temporomandibular joint (측두하악관절의 초음파영상과 자기공명영상에서 하악과두 외측면과 관절낭간 거리 측정치 비교)

  • Lee Tae-Wan;Yoo Dong-Soo;Han Won-Jeong;Kim Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.41-48
    • /
    • 2006
  • Purpose : To evaluate the reliability and clinical usefulness of ultrasonography in the temporomandibular joint (TMJ). Materials and Methods : Parasagittal and paracoronal 1.5 T MR images and 7.5 MHz ultrasonographs of 40 TMJs in 20 asymptomatic volunteers were obtained. Disc position using MR imaging was evaluated and the distance between the lateral surface of mandibular condyle and the articular capsule using MR image and ultrasonograph of 27 TMJs with normal disc position was measured and compared. Intraobserver and interobserver measurements reliability was evaluated by using interclass correlation coefficients (ICC) and measurement error. Also, the distance measured on ultrasonographs was compared, according to mouth position and disc postion. Results : The normal disc position was found in 27 of 40 asymptomatic joints. At the intraobserver reliability of measurement, ICC at the closed and open mouth position were 0.89 and 0.91. The measurement error was 0.4% and 0.5%. At the interobserver reliability, ICC at the closed and open mouth position were 0.92 and 0.81. The measurement error was 0.4% and 0.7%. At the TMJ with normal disc position, the distances between the lateral surface of mandibular condyle and the articular capsule measured on MR images and ultrasonographs were $2.0{\pm}0.7mm,\;1.8{\pm}0.5mm$, respectively (p<0.05). On the ultrasonographs, the distances at open mouth position were $1.2{\pm}0.5mm$ (p<0.05). At the TMJ with medially displaced disc, the distances at the closed and open mouth position were $1.3{\pm}0.3\;mm\;and\;0.9{\pm}0.2\;mm$ (p<0.05). Conclusion : The results suggest ultrasonography of TMJ is a reliable imaging technique for assessment of normal disc position.

  • PDF

Analysis of Measurement Accuracy for Craniovertebral Junction Pathology : Most Reliable Method for Cephalometric Analysis

  • Lee, Ho Jin;Hong, Jae Taek;Kim, Il Sup;Kwon, Jae Yeol;Lee, Sang Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.4
    • /
    • pp.275-279
    • /
    • 2013
  • Objective : This study was designed to determine the most reliable cephalometric measurement technique in the normal population and patients with basilar invagination (BI). Methods : Twenty-two lateral radiographs of BI patients and 25 lateral cervical radiographs of the age, sex-matched normal population were selected and measured on two separate occasions by three spine surgeons using six different measurements. Statistical analysis including intraclass correlation coefficient (ICC) was carried out using the SPSS software (V. 12.0). Results : Redlund-Johnell and Modified (M)-Ranawat had a highest ICC score in both the normal and BI groups in the inter-observer study. The M-Ranawat method (0.83) had a highest ICC score in the normal group, and the Redlund-Johenll method (0.80) had a highest ICC score in the BI group in the intra-observer test. The McGregor line had a lowest ICC score and a poor ICC grade in both groups in the intra-observer study. Generally, the measurement method using the odontoid process did not produce consistent results due to inter and intra-observer differences in determining the position of the odontoid tip. Opisthion and caudal point of the occipital midline curve are somewhat ambiguous landmarks, which induce variable ICC scores. Conclusion : On the contrary to other studies, Ranawat method had a lower ICC score in the inter-observer study. C2 end-plate and C1 arch can be the most reliable anatomical landmarks.