• 제목/요약/키워드: normal fault

검색결과 564건 처리시간 0.029초

Geological Structures and Evolution of the Tertiary Chŏngja Basin, Southeastern Margin of the Korean Peninsula (울산군 강동면 제 3기 정자분지(亭子盆地)의 지질구조와 분지발달)

  • Son, Moon;Kim, In-Soo
    • Economic and Environmental Geology
    • /
    • 제27권1호
    • /
    • pp.65-80
    • /
    • 1994
  • The Tertiary $Ch{\check{o}}ngja$ basin is located in the southeastern coastal area of the Korean Peninsula. It is a lozenge shaped fault-bounded basin with circa $5{\times}5km$ areal extent, isolated from other Tertiary basins by the Cretaceous Ulsan Formation in-between. The northwestern boundary of the basin is a domino/listric type normal fault trending $N30^{\circ}E$, whereas its southwestern boundary is a dextral strike-slip fault (trending $N20^{\circ}W$) with a lateral offset of more than 1 km. The basin is bounded by the East Sea on the eastern margin. Basin-fills consist of extrusive volcanic rock (Tangsa Andesites) of Early Miocene (16~22 Ma in radiometric age), unconsolidated fluviatile conglomerate (Kangdong Formation) and shallow brackish-water sandstone ($Sinhy{\check{o}}n$ Formation). The latter yields abundant Vicarya-Anadara molluscan fossils of early Middle Miocene age. The Tertiary strata become younger toward the northwestern boundary-fault of the basin, showing a zonal distribution pattern parallel to the fault: the younger sedimentary formations occupy a narrow zone of 2 km width along the northwestern boundary-fault, whereas the older Tangsa Andesites underlie them unconformably in the eastern and southeastern portions of the basin. The strata in the basin, including the Tangsa Andesites, are tilted (about $20^{\circ}$) toward the northwestern boundary-fault Sedimentary strata thicken toward the boundary-fault, forming a wedge shaped half-graben structure. A number of small-scale syndepositional normal growth faults and graben structures are observed in the sedimentary strata. These extensional structures have the same trend as the normal northwestern boundary-fault which we interpret as a pull-apart detachment fault. These characteristics imply persistent extension during the basin evolution, caused by a NW-SE directed tensional force. The $Ch{\check{o}}ngja$ basin is, thus, a kind of syndepositional tectonic basin evolved in a strike-slip (pull-apart) regime. The latter was caused by a dextral simple shear associated with the NNW-SSE opening of the East Sea. In view of the fact that the normal growth faults do not cut through the uppermost portion of the youngest $Sinhy{\check{o}}n$ Formation, it is inferred that the tensional force came to be inactive in the early Middle Miocene. This is coincident in timing with the termination of the East Sea opening (15 Ma).

  • PDF

Real-Time Fault Detection in Discrete Manufacturing Systems Via LSTM Model based on PLC Digital Control Signals (PLC 디지털 제어 신호를 통한 LSTM기반의 이산 생산 공정의 실시간 고장 상태 감지)

  • Song, Yong-Uk;Baek, Sujeong
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • 제44권2호
    • /
    • pp.115-123
    • /
    • 2021
  • A lot of sensor and control signals is generated by an industrial controller and related internet-of-things in discrete manufacturing system. The acquired signals are such records indicating whether several process operations have been correctly conducted or not in the system, therefore they are usually composed of binary numbers. For example, once a certain sensor turns on, the corresponding value is changed from 0 to 1, and it means the process is finished the previous operation and ready to conduct next operation. If an actuator starts to move, the corresponding value is changed from 0 to 1 and it indicates the corresponding operation is been conducting. Because traditional fault detection approaches are generally conducted with analog sensor signals and the signals show stationary during normal operation states, it is not simple to identify whether the manufacturing process works properly via conventional fault detection methods. However, digital control signals collected from a programmable logic controller continuously vary during normal process operation in order to show inherent sequence information which indicates the conducting operation tasks. Therefore, in this research, it is proposed to a recurrent neural network-based fault detection approach for considering sequential patterns in normal states of the manufacturing process. Using the constructed long short-term memory based fault detection, it is possible to predict the next control signals and detect faulty states by compared the predicted and real control signals in real-time. We validated and verified the proposed fault detection methods using digital control signals which are collected from a laser marking process, and the method provide good detection performance only using binary values.

A Study for the Improvement of Fault Detection on Fault Indicator using DWT and Neural Network (신경회로망과 DWT를 이용한 고장표시기의 고장검출 개선에 관한 연구)

  • Hong, Dae-Seung;Yim, Hwa-Young
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.46-48
    • /
    • 2007
  • This paper presents research about improvement of fault detection algorithm in FRTU on the feeder of distribution system. FRTU(Feeder Remote Terminal Unit) is applied to fault detection schemes for phase fault, ground fault, and cold load pickup and Inrush restraint functions distinguish the fault current and the normal load current. FRTU is occurred FI(Fault Indicator) when current is over pick-up value also inrush current is occurred FRTU indicate FI. Discrete wavelet transform(DWT) analysis gives the frequency and time-scale information. The neural network system as a fault detector was trained to discriminate inrush current from the fault status by a gradient descent method. In this paper, fault detection is improved using voltage monitoring system with DWT and neural network. These data were measured in actual 22.9kV distribution system.

  • PDF

Investigating the Stress on Fault Plane Associated with Fault Slip Using Boundary Element Method (경계요소법을 이용한 단층 슬립에 따른 단층면 응력에 관한 연구)

  • Sung Kwon, Ahn;Hee Up, Lee;Jeongjun, Park;Mintaek, Yoo
    • Tunnel and Underground Space
    • /
    • 제32권6호
    • /
    • pp.598-610
    • /
    • 2022
  • Avoiding a fault zone would be a best practice for safety in underground construction, which is only sometimes possible because of many restrictions and other field conditions. For instance, there is an ongoing conception of Korea-Japan subsea tunnels that inevitably cross a massive fault system in the Korea Strait. Therefore it was deemed necessary to find an efficient way of predicting the likely behaviour of underground structures under fault slip. This paper presents the findings from simple numerical analysis for investigating the stress induced at a normal fault with a dip of 45 degrees. We used a boundary element software that assumed constant displacement discontinuity, which allowed the displacement to be estimated separately at both the fault's hangingwall and footwall sides. The results suggested that a principal stress rotation of 45 degrees occurred at the edges of the fault during the slip, which was in agreement with the phenomenon for fault plane suggested in the body of literature. A simple numerical procedure presented in this paper could be adopted to investigate other fault-related issues associated with underground structure construction.

A Chaotic Pattern Analysis of High Impedance Faults (고저항 지락 사고의 카오스 패턴 해석)

  • Ko, Jae-Ho;Bae, Young-Chul;Yim, Hwa-Yeoung
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 B
    • /
    • pp.542-544
    • /
    • 1997
  • The analysis of distribution line faults is essential to the proper protections in the power system. A high impedance fault does not make enough current to cause conventional protective devices. In this paper, Fractal dimensions are estimated for distinction between normal status and fault status in the power system. Application of the concepts of the fractal geometry to analyze chaotic properties of high impedance fault current was described. In addition, to analyze variation of fault current and normal current on phase plane, embedding state variables are reconstructed from 1 dimensional time series.

  • PDF

Predictions of Short-Circuit Characteristics of Rotor Windings in a Generator using Electromagnetic Analysis (전자장해석을 통한 발전기 회전자권선 단락특성 예측)

  • Kim, Dong-Hun;Song, Myung-Kon;Park, Jung-Shin;Lee, Dong-Young
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • 제55권11호
    • /
    • pp.572-576
    • /
    • 2006
  • As the increasing of capacity and technology of power facilities, rotating machines such as turbine generators and water turbines are getting higher at capacity but smaller in size. Thus the monitoring and diagnosis of generators for fault detection and protection has attracted intensive interest. Most of electrical faults of rotating machines appear in their windings. In case of an after-fault in high capacity rotating machines, the recovering cost is usually very expensive and additional time is necessary for returning in a normal situation. In this paper, the magnetic flux patterns in air-gap of a generator under various fault states as well as a normal state are simulated by a conventional FEM tool. These results are successfully applied to detection and diagnosis of the short-circuit condition in rotor windings of a high capacity generator.

Restudy of Fault Current Distribution Ratio with Grounding Type of Normal Joint Box in Underground Transmission Systems (지중송전계통에서 보통접속함의 접지방식에 따른 고장전류분류율 재검토)

  • Hong, D.S.;Kang, J.W.;Jang, T.I.;Kim, H.H.;Yoon, H.H.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.500-502
    • /
    • 2002
  • Receltly, Underground transmission system is getting increased. Therefore the design of grounding system becomes very important to discharge overcurrent of lightning and fault through earth and reduce sheath induced voltage and sheath circulation current. This paper describes fault current distribution ratio for grounding line with grounding types of normal joint box and sheath grounding resistor at line-to-ground fault of cable.

  • PDF

Strip Rupture Detection System of Cold Rolling Mill using Transient Current Signal (과도 전류신호를 이용한 냉간 압연기의 판 터짐 검지 시스템)

  • Yang, S.W.;Oh, J.S.;Shim, M.C.;Kim, S.J.;Yang, B.S.;Lee, W.H.
    • Journal of Power System Engineering
    • /
    • 제14권2호
    • /
    • pp.40-47
    • /
    • 2010
  • This paper proposes a fault detection system to detect the strip rupture in six-high stand Cold Rolling Mills based on transient current signal of an electrical motor. For this work, signal smoothing technique is used to highlight precise feature between normal and fault condition. Subtracting the smoothed signal from the original signal gives the residuals that contains the information related to the normal or faulty condition. Using residual signal, discrete wavelet transform is performed and acquire the signal presenting fault feature well. Also, feature extraction and classification are executed by using PCA, KPCA and SVM. The actual data is acquired from POSCO for validating the proposed method.

A Study on High Impedance Fault Detection using Lifting Scheme (Lifting을 이용한 고저항고장 검출에 관한 연구)

  • Hong, D.S.;Yim, H.Y.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2228-2230
    • /
    • 2002
  • The research presented in this paper focuses on a method for the detection of High Impedance Fault(HIF). The method will use the Lifting and neural network system. HIF on the multi-grounded three-phase four-wires primary distribution power system cannot be detected effectively by existing over current sensing devices. These paper describes the application of lifting scheme to the various HIF data. These data were measured in actual 22.9kV distribution system. Wavelet transform analysis gives the frequency and time-scale information. The neural network system as a fault detector was trained to discriminate HIF from the normal status by a gradient descent method. The proposed method performed very well by proving the right state when it was applied staged fault data and normal load mimics HIF, such as arc-welder.

  • PDF

Fault determination of power transformer by using analysis of vibration signal (진동신호 분석을 이용한 변압기 고장판별법 연구)

  • Park, Su-Mun;Chung, Chan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.1152-1154
    • /
    • 1996
  • In power transformers, vibration occurs at winding, core and case due to current, voltage, temperature changing and winding reformation. Winding deformation and change of vibration signals are occurred due to electromagnetic force induced by fault current. In this paper, in normal and fault states, the trends of fundamental waves and higher harmonics are considered. To inspect the factors that affect the fundamental waves and higher harmonics, the trends are considered with varying voltage and load. Determination functions are generated and applied to signals so that normal and fault state are determined by determination functions.