• Title/Summary/Keyword: normal eye

Search Result 363, Processing Time 0.028 seconds

Evaluation of Worker's Health and Occupational Exposure to Perchloroethylene in Laundries (Perchlotoethylene을 사용하는 세탁소 작업자들의 직업성 폭로와 건강에 관한 연구)

  • An, Sun-Hee;Lee, Jong-Hwoa;Park, Jong-An
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.224-239
    • /
    • 1994
  • In this study we examined several subjective symptoms in an exposed group and an unexposed group to perchloroethylene. The exposed group consists to 30 workers employed in 23 dry-cleaning establishments located in Chung Cheung Do, whereas the unexposed group consists of 42 officers employed in a certain university. This study was conducted from October, 1993 to March, 1994. Also we investigated personal exposure levels and area concentration of PCE, and performed hematological and biochemical examination in blood and urine samples from the exposed group. The results are : 1. The exposed group highly complains several subjective symptoms, particularly in neuropsychiatry, eye, respiratory system and digestive system, compared with the unexposed group. But complaint rates in the exposed group are not related with PCE exposure levels. 2. PCE exposure levels for all dry-cleaning establishment varied widely, from 0.18 to 37.58ppm. The mean exposure level for centers of chain was 16.85ppm, and for local laundries was 8.83ppm, while for self-service establishment it was 3.07ppm. Eighty three percent of the workers were exposed less than the half-level(25.0ppm) of the Korea 50.0ppm standard for eight-hour PCE exposure. Seventeen percent of them exceeded the half-level of the Korea TLV. 3. Statistical correlation exists between the work load(number of operation cycles of equipment and the mass of processed textiles) and the personal exposure levels to be observed. 4. In hematological examination the values of WBC, RBC, Hgb, Hct, MCV, MCH, MCHC and PLT in the exposed group were within normal ranges. In biochemical examination(GOT, GPT, ALP, U-A and LDH) most of the items were within normal ranges. From this surveys conducted on 23 dry-cleaning establishments, the complaint rates of the exposed group to PCE in several subjective symptoms were higher than those of the unexposed group, and PCE exposure levels in all dry-cleaning establishment were below the Koera standard 50.0ppm. In hematological and biochemical examination the significant abnormalities by occupational exposure to PCE were not observed. However, the workers employed in dry-cleaning establishments are always faced with risk, becauses they are also exposed to several organic solvents used to remove stains. Therefore, various measures to improve occupational environment in dry-cleaning establishment should be considered.

  • PDF

Expected Values for the Analysis of Accommodation and Vergence Dysfunction of Young Adluts (젊은 성인의 조절 및 이향운동 기능장애 분석을 위한 표준 값)

  • Baarg, Saang-Bai
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.127-134
    • /
    • 2008
  • Purpose: The purpose of this study was to determine the expected values of accommodation and vergence system for analysis of binocular vision. Methods: Seventy three healty subjects without past history of eye disease were selected for this study, Patients showing clinical binocular anomalies including manifest squint and intermittent heterotropia were excluded and data was collected on 54 patients(mean age, 25.3${\pm}$2.7 year). Near point of convergence, distance and near phoiras were measured based on objective deviation angle. And then AC/ A ratio, relative accommodation were measured and all of the data were compared with the Morgan's expected values. Results: The values of distance and near heterophoria were 1.24${\pm}$2.72${\Delta}$ and 2.70${\pm}$4.91${\Delta}$ respectively and the gradient AC/A ratio was 3.92${\pm}$2.17${\Delta}$/D which were all about the same compared with the Morgan's expected values. The values of distance negative fusional convergence was same, however, distance positive fusional convergence was 7${\Delta}$ greater than the Morgan's one. There were no significant differences in the range values of both near vergences while the range of distance vergence was relatively larger than the Morgan's one. Positive relative accommodation was +0.37D greater and negative relative accommodation was -0.63D greater than the Morgan's values. Conclusions: The findings in this study appear that the Morgan's expected values have a possibilities of including considerable proximal convergence value. In comparison with Morgan's values, Korean's normal expected values have much different values of especially BO limit, so if the Morgan's values are directly applied to binocular vision analysis for Korean people, it may lead to an inaccurate binocular vision diagnosis. This results can be used to diagnose the accommodation and vergence system of Korean normal young adults.

  • PDF

Usefulness of Non-coplanar Helical Tomotherapy Using Variable Axis Baseplate (Variable Axis Baseplate를 이용한 Non-coplanar 토모테라피의 유용성)

  • Ha, Jin-Sook;Chung, Yoon-Sun;Lee, Ik-Jae;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Jeon, Mi-Jin;Cho, Yoon-Jin;Kim, Ki-Kwang;Lee, Seul-Bee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • Purpose: Helical Tomotherapy allows only coplanar beam delivery because it does not allow couch rotation. We investigated a method to introduce non-coplanar beam by tilting a patient's head for Tomotherapy. The aim of this study was to compare intrafractional movement during Tomotherapy between coplanar and non-coplanar patient's setup. Materials and Methods: Helical Tomotherapy was used for treating eight patients with intracranial tumor. The subjects were divided into three groups: one group (coplanar) of 2 patients who lay on S-plate with supine position and wore thermoplastic mask for immobilizing the head, second group (non-coplanar) of 3 patients who lay on S-plate with supine position and whose head was tilted with Variable Axis Baseplate and wore thermoplastic mask, and third group (non-coplanar plus mouthpiece) of 3 patients whose head was tilted and wore a mouthpiece immobilization device and thermoplastic mask. The patients were treated with Tomotherapy after treatment planning with Tomotherapy Planning System. Megavoltage computed tomography (MVCT) was performed before and after treatment, and the intrafractional error was measured with lateral(X), longitudinal(Y), vertical(Z) direction movements and vector ($\sqrt{x^2+y^2+z^2}$) value for assessing overall movement. Results: Intrafractional error was compared among three groups by taking the error of MVCT taken after the treatment. As the correction values (X, Y, Z) between MVCT image taken after treatment and CT-simulation image are close to zero, the patient movement is small. When the mean values of movement of each direction for non-coplanar setup were compared with coplanar setup group, X-axis movement was decreased by 13%, but Y-axis and Z-axis movement were increased by 109% and 88%, respectively. Movements of Y-axis and Z-axis with non-coplanar setup were relatively greater than that of X-axis since a tilted head tended to slip down. The mean of X-axis movement of the group who used a mouthpiece was greater by 9.4% than the group who did not use, but the mean of Y-axis movement was lower by at least 64%, and the mean of Z-axis was lower by at least 67%, and the mean of Z-axis was lower by at least 67%, and the vector was lower by at least 59% with the use of a mouthpiece. Among these 8 patients, one patient whose tumor was located on left frontal lobe and left basal ganglia received reduced radiation dose of 38% in right eye, 23% in left eye, 30% in optic chiasm, 27% in brain stem, and 8% in normal brain with non-coplanar method. Conclusion: Tomotherapy only allows coplanar delivery of IMRT treatment. To complement this shortcoming, Tomotherapy can be used with non-coplanar method by artificially tilting the patient's head and using an oral immobilization instrument to minimize the movement of patient, when intracranial tumor locates near critical organs or has to be treated with high dose radiation.

  • PDF

Changes in Subjective Discomfort, Blinking Rate, Lens Centration and the Light Transmittance of Lens Induced by Exceeding Use of Daily Disposable Circle Contact Lenses in Dry Eyes (일회용 써클소프트렌즈의 일일 초과착용 시 유발되는 건성안의 자각적 불편감, 순목횟수, 중심안정 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kang, Shin Young;Chang, Jung Iee;Han, Arum;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 2014
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.

Effects of various CLEAN-UP techniques on enamel surface roughness (수종의 CLEAN-UP technique이 법랑질 표면거칠기에 미치는 영향)

  • CHO, Sang-Wan;KWON, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.791-800
    • /
    • 1997
  • Sixty premolars extracted for orthodontic treatment were divided into four groups, and the residual resin was removed with four different rotary finishing instruments at a fixed speed of $18,500{\pm}300 rpm$ on the low speed handpiece. The instruments were G1; No.169L carbide fissure bur, G2: No.2 round bur, G3; No.4 round bur, G4: No.8 round bur. Then, the enamel received a S-second polishing with a rubber cup and a pumice. To find the extent of loss on the enamel at this point, prophylaxis was done with the rubber cup and pumice prior to bonding of the bracket(P1) and removal of residual resin by means of appropriate procedure applicable to each respective group(P2) followed. The final polishing was done with the rubber cup and pumice(P3), and the enamel surface roughness was measured each by the surface measuring instrument. The whole process was observed under a scanning electron microscope to gain the following results: At P2, the enamel surface roughness in G1 showed most smoothly with $2.60{\pm}0.55{\mu}m;\;in\;G2,\;3.24{\pm}0.80{\mu}m;\;in\;G3,\;3.44{\pm}0.94{\mu}m;\;in\;G4,\;3.89{\pm}0.54{\mu}m$, the roughest. G2 and G3 showed no statistical significance(P>0.05). At P3, the enamel surface roughness in G1 showed most smoothly with $2.29{\pm}0.47{\mu}m;\;in\;G2,\;2.44{\pm}0.56{\mu}m;\;in\;G3,\;2.44{\pm}0.56{\mu}m;\;in\;G4,\;2.92{\pm}0.43{\mu}m$, the roughest. G1 vs G2, G3, and G2 vs G3 had no statistical significances(p>0.05). In all groups, P2 and P3 showed rougher in surface roughness than P1, and P2 rougher than P3(p<0.01). In a case of 5-second prophylaxis with the rubber cup and the pumice on a virgin, normal enamel, fine scratches were found under the scanning electron microscope. In all four groups, unremovable gouges remained even after polishing with the ubber and pumice; residual resin was not observed with naked eye when finished with the rubber and pumice, but the resin debris was observed under the scanning electron microscope.

  • PDF

Effect of Vision Training using Fresnel Prism Lens on Fusional Vergence and Accommodation (프레넬 프리즘렌즈를 이용한 시기능 훈련이 조절과 융합버전스에 미치는 영향)

  • Kim, Yong-Gil;Kim, Min-Kyung;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.159-164
    • /
    • 2012
  • Purpose: Of the various methods of vision training, the essay aims to explore the effective ways of using the Fresnel prism lens in order to expand the positive fusional vergence for the patient having specific condition of convergence insufficiency or basic exophoria. Methods: 15 students of city of Daejeon university without an eye disease (average age $22.73{\pm}1.68$) were selected and underwent the subjective refraction test and binocular vision test, and recording their test results before vision training and replacing an identical frame with a lens of same quality after the full calibration, the lens was then adhered with the Fresnel prism lens and continued to train for thirty minutes daily during two weeks. Afterwards, the binocular vision test was reattempted. The observation of the change in the results of the binocular vision test in use of the fresnel prism lens in the vision training test was researched. Results: After training, the positive fusional vergence had increased to a number of $22.27{\pm}2.26$ $\Delta$, to 7.80 $\Delta$, at near, the fused cross cylinder test increased to an average of $0.55{\pm}0.09$ D, 0.40 D after training, showing a normal result. The value of negative relative accommodation after training had an average of $2.22{\pm}0.08$D, showing that 0.42 D had increased. The value of near point of convergence after training had an average of $6.13{\pm}0.53$ cm, showing that 2.80 cm had decreased. To patients who had convergence insufficiency or basic exophoria, the value of the near vision test that used the Fresnel prism lens which was able to expand BO positive fusional vergence had increased without phoria. Conclusions: The changes were tested and the effectiveness of the Fresnel prism lens, due to the nature of the lens itself, helped with both cosmetic effects and cost. It also allows good optical correction effects, in addition to these clinical effects indicated before. Therefore, it may be determined that the Fresnel prism lens binocular vision therapy for patients is more popular and highly recommended.

Serotypes and Antimicrobial Susceptibility of Streptococcus pneumoniae (폐구균의 혈청형 분포와 항생제 감수성에 관한 연구)

  • Choi, Kyoung-Min;Kim, Jeong-Hyun;Shin, Kyoung-Mi;Yeon, Soo-In;Shin, Jeon-Soo;Yong, Dong-Eun;Lee, Kyoung-Won;Kim, Dong-Soo
    • Pediatric Infection and Vaccine
    • /
    • v.10 no.2
    • /
    • pp.159-166
    • /
    • 2003
  • Purpose : Streptococcus pneumoniae is part of the normal flora but is also responsible for causing many invasive diseases such as pneumonia, meningitis, and sepsis in addition to noninvasive diseases such as otitis in children. Multi-drug resistant strains has raised a lot of concern worldwide and thus the importance of prevention has been emphasized. We have analyzed the current serotypes and antibiotic sensitivity of each serotype as a baseline study to estimate the efficacy of the pneumococcal vaccine in Korean children. Methods : One hundred sixteen cases of pneumococcus cultured at Yonsei Medical Center from September 2001 to January 2003 were analyzed. The serotyping was done with the Quellung reaction and penicillin resistance was tested using the oxacillin disc diffusion method. Results : Pneumococcus were cultured from the sputum in 76 cases(65.5%), from the blood in 13 cases(11.2%), from the ear discharge in 12 cases(10.3%), from the throat in 7 cases(6.0%), from the nasal cavity in 2 cases(1.7%), and one case(0.9%) each from the cerebrospinal fluid, eye discharge, peritoneal fluid, post-operational wound, brain abscess, and catheter tip. Serotyping was possible with 98 cases and the following serotypes were found; 15 cases of type 19F(15.3%), 11 cases of 19A(11.2%), 8 cases of 11A(8.2%), 7 cases each of 6A, 14 and 3(7.1%), 6 cases each of 35, 6B and 23F(6.1%). Eighty two cases(70.7%) out of 116 cases were penicillin resistant and serotypes 19F, 19A, 11A, 23F, 6A, 9V constituted the majority, 48 cases(59.8%). These serotypes showed resistance to cotrimoxazole (74.4%), tetracycline(69.5%), and erythromycin(90.3%) as well. In the 22 cases cultured from children, 19A and 19F were found in 25.0%, 6A, 6B, and 23F in 10.0%, 11A, 14, 19, and 29 in 5.0%. Fifty percent(10/20) of the clinical isolates were represented in the current 7-valent pneumococcal protein conjugate vaccine, and 85%(17/20) when the cross-reacting serotypes were included. Penicillin resistance was found in 86.4%(19/22). Conclusion : The percentage of serotypes included in the 7 valent pneumococcal protein conjugate vaccine found in our study was 40.8% which was less than other prior studies. In anticipation of a change of pneumococcal serotypes, a nationwide multicenter study is needed before the initiation of pneumococcal vaccines in Korea.

  • PDF

The Factors Influencing the Asthenopia of Emmetropia with Phoria (사위를 가진 정시안의 안정피로에 영향을 미치는 요인)

  • Kim, Jung-Hee;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.1
    • /
    • pp.71-82
    • /
    • 2005
  • The aim of this study was to provide fundamental data for the factors influencing the asthenopia of emmetropia with phoria and alleviation of asthenopia. A total of 348 subjects, aged between 19 and 30 years old, who had no strabismus, an eye trouble or whole body disease, were examined using corrected visual acuity, corrected diopter, stereopsis and suppression tests from September of 2002 to September of 2004. We excluded 21 subjects for the following reasons: if they had an amblyopia affecting binocular vision or inaccurate data. After these exclusions, 327 subjects remained. We then individually measured the refractive error correction, pupillary distance, optical center distance, phoria, convergence, accommodation and the AC/A as well as the asthenopia during binocular vision using a questionnaire. After analysis of factors affecting asthenopia, we also examined the reductive effect of a prism on the asthenopia in subjects who had asthenopia. To determine the factors affecting asthenopia during binocular vision, statistic analyses were carried out using the Chi-square test and the multivariate Logistic regression model. The results of this study were as follow. For asthenopia during near binocular vision of emmetropia with phoria, in case of the lower the accommodation and convergence, a significantly higher rate of asthenopia was observed (p<0.001). When the AC/A is lower, the higher the rate of asthenopia was observed but not significantly and there was no association between phoria and asthenopia. When the multivariate logistic regression model was used to determine factors affecting binocular vision of emmetropia with phoria, in case of the lower accommodation and convergence, a significantly higher rate of asthenopia was observed. when the phoria is esophoria or higher exophoria, or when the AC/A is lower than normal, the higher the rate of asthenopia was observed but not significantly and there was no association between phoria. AC/A and asthenopia. Therefore accommodation and convergence could be predictive factors for asthenopia during near distance binocular vision. Prism was used among' subjects who had asthenopia during near distance binocular vision, the symptom of asthenopia was eased up to 74.2% in emmetropia with phoria.

  • PDF

Antiglycemic Effect of Carnosine in Diabetic Mice (당뇨 마우스에서 카르노신의 혈당강하 효과)

  • Hue, Jin-Joo;Kim, Jong-Soo;Kim, Jun-Hyeong;Nam, Sang-Yoon;Yun, Young-Won;Jeong, Jae-Hwang;Lee, Beom-Jun
    • Journal of Food Hygiene and Safety
    • /
    • v.24 no.4
    • /
    • pp.391-397
    • /
    • 2009
  • Carnosine is a dipeptide ($\beta$-alanyl-L-histidine) found in mammalian brain, eye, olfactory bulb and skeletal muscle at high concentrations. Its biological functions include antioxidant and anti-glycation activities. The objectives of this study were to investigate anti-diabetic effects of carnosine as determined by blood glucose levels in glucose tolerance test (GTT) and insulin tolerance test (ITT), insulin level and serum biochemical and lipid levels in male C57BL/6J db/db mice. There were five experimental groups including normal (C57BL/6J), control (vehicle), and three groups of carnosine at doses of 6, 30, and 150 mg/kg b.w. Carnosine was orally administered to the diabetic mice everyday for 8 weeks. There was no significant difference in body weight changes in carnosine-treated groups compared to the control. The treatments of carnosine significantly decreased the blood glucose level in the diabetic mice compared with the control (p < 0.05) after 5 weeks. The treatments of carnosine also significantly decreased the blood glucose levels in GTT and ITT and glycosylated hemoglobin (HbA1c), compared with the control (p < 0.05). Carnosine at the dose of 6 mg/kg significantly decreased the serum insulin level compared to the control (p < 0.05). Carnosine significantly increased total proteins but significantly decreased lactate dehydrogenase and blood urea nitrogen compared with the control (p < 0.05). Carnosine also significantly decreased glucose, LDL, and triglyceride in the serum of diabetic mice compared to the control (p < 0.05). These results suggest that carnosine has a hypoglycermic effect resulting from reduction of glucose and lipid levels and that high carnosine-containing diets or drugs may give a benefit for controlling diabetes mellitus in humans.

The Study of Spontaneous Developmental Abnormalities and Toxicology of Benomyl and Its Metabolite on Salamander, Hynobius leechii.

  • Park, Yong-Uk
    • Proceedings of the Korea Society of Environmental Biology Conference
    • /
    • 2005.12a
    • /
    • pp.38-45
    • /
    • 2005
  • The egg bags of Korean salamander(Hynobius leechii) were collected from farmlands in Gyeongsangnam-do area. The assumed breeding time, numerical variation of embryos in each egg bag, mortality and the rates of abnormalities were investigated. The toxicity of benomyl, the metabolite carbendazim and BIC which were frequently spread in agricultural area and caused spontaneous embryonic malformation was investigated. The assumed breeding time between the end of February and the end of March has the difference about a month because of a habitat and it takes about 2 or 3 weeks from laying eggs to hatching. The length of each egg bag and the number of embryos were very varied in each area. It is due to geographical variation. Among egg bags in total study area, only 406 of egg bags(17.70% of total egg bags) developed all of embryos to normal larvae, and 78.49% of total embryos were normally developed. The patterns of spontaneous embryonic malformation were 26 species from A to Z and the abnormal patterns in individual were 8 species and above. the geographical differences about the abnormal pattern were identified and 11 habitats categorized 4 groups. The most frequent abnormality in Gyeongsangnam-do area is the dysplasia of external gill. The caudal dysplasia, abdominal blister and dysplasia of fin were also frequently observed. Individuals showing severe external defect were histologically studied and they showed retinal hypo-pigmentation, thyroid carcinoma, somatic muscular dysplasia, degeneration of cephalic neuron and various organ dysplasia. Benomyl and carbendazim were treated by 10pM$^{\sim}$10uM and BIC was treated by 1$^{\sim}$40ppm to know the effect of toxicity about toxic substance of salamander. After benomyl was treated, a survival rate was sharply dropped from 2 to 8 days. $LC_{100}$ identified in $1{\mu}M$, $LC_{50}$ identified between 100nM and $1{\mu}M$. $EC_{50}$ was assumed between 10nM and 100nM. The prevalent external malformation was abdomen swelled abnormally and histo-pathological effects were abdomen, neural tube and lens hernia. This suggests that benomyl is the toxicitic substance which inhibits the development of digestive system and nervous system. The result of treated carbendazim was similar to that of the treated benomyl. The survival rate is sharply dropped between 2 and 6 days. $LC_{100}$ was identified $1{\mu}M$ and $LC_{50}$ was identified between 10nM and 100nM. This shows that cabendazim has stronger lethal toxicity than benomyl. Ventral blister, eye dysplasia and cephalic dysplasia in the individual of external malformation mean that cabendazim affected nervous system much more than benomyl. Because the toxicity of BIC affected less in the beginning but affected more in the near hatching period, the period causing toxicity is somewhat different. $LC_{100}$ identified near 40ppm and $LC_{50}$ identified near 25ppm. The external defect shows mainly ventral blister and histo-pathological results show intestinal deformities. This result suggests the BIC inhibited strongly the development of digestive system. These abnormal developments may be caused by antimitotic action, inhibition of tubulin complex, destruction of microtubule, inhibitions of neurulation and closing of neural fold, and by the inhibition of movement of neural crest cells of benomyl. These abnormal developments may be caused by the rupture of epithelium, the loss of microtubule, the reduction of spindle size, the inhibition of spindle assembly formation, the destruction of spindle poles of carbendazim. These abnormal developments may be caused cytotoxicity by inhibition of the synthesis of a number of macromolecules and similar reaction the inhibition of benomyl.

  • PDF