• Title/Summary/Keyword: nonmagnetic laboratory

Search Result 10, Processing Time 0.027 seconds

ADD's Test Facilities for National Defense Magnetic Research (국방 자기분야 연구를 위한 국방과학연구소 시험시설)

  • Yang, Chang-Seob;Chung, Hyun-Ju;Jung, Woo-Jin
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.4
    • /
    • pp.114-122
    • /
    • 2014
  • Since 1990, Agency for Defense Development (ADD) has been operating the nonmagnetic laboratory and the magnetic sensors laboratory to develop the key technology of the ship's magnetic silencing and to research the high performance magnetic sensors used in the weapon system and to perform the technical support for Republic of Korea Navy. Recently, the main test equipment in the laboratories has been upgraded to improve the measurement and analysis abilities against magnetic target and to evaluate the performance of the magnetic sensors. In this paper, the capability and the current state of magnetic test facilities of ADD are described.

Exchange Bias Modifications in NiFe/FeMn/NiFe Trilayer by a Nonmagnetic Interlayer

  • Yoon, S.M.;Sankaranarayanan V.K.;Kim, C.O.;Kim, C.G.
    • Journal of Magnetics
    • /
    • v.10 no.3
    • /
    • pp.99-102
    • /
    • 2005
  • Modification in exchange bias of a NiFe/FeMn/NiFe trilayer, on introduction of a nonmagnetic Al layer at the top FeMn/NiFe interface, is investigated in multilayers prepared by rf magnetron sputtering. The introduction of Al layer leads to vanishing of bias of the top NiFe layer. But the bias for the bottom NiFe layer increases steadily with increasing Al layer thickness and attains bias (230 Oe) which is greater than that of the trilayer without the Al layer (150 Oe). When the top NiFe layer thickness is varied, exchange bias has highest value at 12 nm thickness for 1 nm thicknes of Al layer. Ion beam etching of the top NiFe layer also leads to an enhancement in bias for the bottom NiFe layer.

A Three-dimensional Magnetic Field Mapping System for Deflection Yoke of Cathode-Ray Tube

  • Park, K.H.;Yoon, M.;Lee, S.M.;Joo, H.D.;Lee, S.D.;Yang, W.Y.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.868-871
    • /
    • 2002
  • In this paper, we introduce an efficient three-dimensional magnetic field mapping system for a Deflection Yoke (DY) in Cathode-Ray Tube (CRT). A three-axis Hall probe mounted in a small cylindrical bar and three stepping motors placed in a nonmagnetic frame are utilized for the mapping. Prior to the mapping starts, the inner contour of DY is measured by a laser sensor to make a look-up table for inner shape of DY. Three-axis magnetic fields are then digitized by a three-dimensional Hall probe. The results of the mapping can be transformed to various output formats such as multipole harmonics of magnetic fields. Field shape in one, two and three-dimensional spaces can also be displayed. In this paper, we present the features of this mapping device and show some analysis results.

  • PDF

MAGNETISM OF NANOCOMPOSITE CoSm-BASED FILMS

  • Shan, Z.S.;Liu, Y.;Jeong, S.Y.;Zhang, Y.B.;Al-Omari, I.A.;Sellmyer, D.J.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.702-709
    • /
    • 1995
  • In this paper we review recent work in our laboratory on nanocomposite CoSm-based films including CoSm with Cr underlayer (CoSm//Cr), exchange-coupled magnetic films consisting of CoSm and FeCo layers (CoSm/FeCo), and CoSm multilayers with nonmagnetic spacing layers of SmO (CoSm/SmO). The emphasis is on detailed investigations of microstructure and magnetic properties for CoSm//Cr films, exchange-spring effects for CoSm/FeCo films, and interlayer effects for (CoSm/ SmO) multilayers.

  • PDF

INTERLAYER COUPLING AND MAGNETOOPTICS IN MULTILAYERS

  • Lu, M.;Bie, Q.S.;Xu, Y.B.;Zhai, H.R.;Zhou, S.M.;Chen, Liangyao;Jin, Q.Y.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.561-566
    • /
    • 1995
  • Additional magnetooptical Kerr effect (AMOKE) was observed in several multilayer structures. For Fe/Pd and Co/Cu Multilayers, AMOKE enhanced the Kerr rotation in short wavelength side, while for Fe/Ag and FeSi/Cu multilayer systems the Kerr rotation enhancement appeared in long wavelength side. A number of ferromagnetic/nonmagnetic/ferromagnetic(FM/NM/FM) sandwiches showed that the AMOKE led to oscillations of Kerr rotation and Kerr ellipticity in certain wavelength range with changing NM layer thickness similar to the oscillatory interlayer coupling. The oscillation of effective optical constants related to the MOKE oscillation was observed for the first time. The mechanisms of the AMOKE were discussed.

  • PDF

Investigation of a Photothrombosis Inducing System for an Observation of Transient Variations in an in vivo Rat Brain

  • Oh, Sung Suk;Park, Hye Jin;Min, Han Sol;Kim, Sang Dong;Bae, Seung Kuk;Kim, Jun Sik;Ryu, Rae-Hyung;Kim, Jong Chul;Kim, Sang Hyun;Lee, Seong-jun;Kang, Bong Keun;Choi, Jong-ryul;Sohn, Jeong-woo
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.499-507
    • /
    • 2018
  • For the spatiotemporally aligned observation of photothrombosis induction and transient variations of in vivo brain stroke, we developed a novel photothrombosis inducing system compatible to a magnetic resonance imaging (MRI) system using nonmagnetic stereotaxic equipment. From the spatial point of view, the system provides a more reliable level of reproducibility of the photothrombosis in each brain. From the temporal point of view, from T1- and T2-weighted in vivo MR (magnetic resonance) images, the transient variations such as incidence, location, and size of the thrombosis are measured quantitatively. In addition, the final variation is observed in the ex vivo brain by TTC (Triphenyltetrazolium chloride) staining based on histological assay and utilized for the verification of the MR images. From the experimental result of the rat brain, the proposed system shows more reliable characteristics for transient variations of brain strokes.

The Structure, and the Magnetic and Magnetoresistive Characteristics of the Spin Valve Multilayers

  • Stobiecki, T.;Czapkiewicz, M.;Wrona, J.;Powroynik, W.;Stobiecki, F.
    • Journal of Magnetics
    • /
    • v.3 no.3
    • /
    • pp.92-95
    • /
    • 1998
  • In this paper we report the low and high angle diffraction results, and the magnetic and magnetroesistive characteristics of the spin valve multilayer structure prepared by the sputter machine Emerald II in the Balzers Laboratory. The investigated system consists of a ferromagnetic free layer (7 nm NiFe) and a ferromagnetic pinned layer (7 nm NiFe), separated from each other by a nonmagnetic (2.1 nm Cu) spacer. The NiFe pinned layer is fixed by the exchange coupling with an antiferromagnetic layer (10 nm FeMn). For such system the magnetoresistance ratio ΔR/R=3.58%, the interlayer exchange coupling $H_c=6.4$ Oe and the field sensitivity 1.15%/Oe were otained.

  • PDF

Magnetic Field Standards Using Magnetic Resonance

  • Park, Po Gyu;Kim, Wan-Seop;Joo, Sung Jung;Lee, Hyung Kew
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.21 no.1
    • /
    • pp.7-12
    • /
    • 2017
  • The nuclear magnetic resonance (NMR) and atomic magnetic resonance (AMR) plays a fundamental role in achieving a high accuracy of magnetic field measurements. Magnetic field unit (T) was realized based on the shielded proton gyromagnetic ratio (${\gamma}^{\prime}_P$), helium-4 gyromagnetic ratio (${\gamma}_{4He}$) and related techniques. The magnetic field standard system has been disseminated by the NMR magnetometer and electromagnet, a Helmholtz coil system, and AMR magnetometer in the nonmagnetic laboratory. A magnetic field standard below 1 mT has been developed by using Cs and Cs- $^4He$ AMR with automatic compensation of an external magnetic field noise. The standards serve for the calibration of magnetometers and support the test of sensors and materials in the range from $5{\mu}T$ to 2.0 T with (1 to 50) ${\mu}T/T$ uncertainty (k=2).

Coersivity Alteration of Free Layer in the [Co/Pd] Spin-valves with Perpendicular Magnetic Anisotropy ([Pd/Co] 다층박막을 이용한 수직스핀밸브 구조에서 비자성층에 인접한 강자성 물질과 그 두께에 따른 자유층의 보자력 변화)

  • Heo, Jang;Choi, Hyong-Rok;Lee, Ky-Am
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.3
    • /
    • pp.89-93
    • /
    • 2010
  • We study the giant magneto-resistance (GMR), coercivity and their dependence on the ferromagnetic layers adjacent to the nonmagnetic layer in a spin-valve structure, [Pd/ferromagnetic] multilayers with perpendicular anisotropy. We fabricated a basic spinvalve structure of $[Pd/Co]_2$/ferro-magnetic layer/nonmagnet/ferro-magnetic layer/$[Pd/Co]_2$/FeMn and investigated the dependence of its GMR and magnetic properties such ad coercivity on the ferromagnetic material to reduce the coercivity of the free layer. We try to reduce the freelayer coercivity by controlled the anisotropy, we insert the material NiFe, $Co_8Fe_2$, $Co_9Fe_1$ to ferromagnetic layers adjacent to the Cu layer. Then, we have been able to reduce the coercivity as low as 100 Oe, and also achieved 6.7% of magneto-resistance ratio when the ferromagnetic layer thickness was 0,7 nm.

K-DEV: A Borehole Deviation Logging Probe Applicable to Steel-cased Holes (철재 케이싱이 설치된 시추공에서도 적용가능한 공곡검층기 K-DEV)

  • Yoonho, Song;Yeonguk, Jo;Seungdo, Kim;Tae Jong, Lee;Myungsun, Kim;In-Hwa, Park;Heuisoon, Lee
    • Geophysics and Geophysical Exploration
    • /
    • v.25 no.4
    • /
    • pp.167-176
    • /
    • 2022
  • We designed a borehole deviation survey tool applicable for steel-cased holes, K-DEV, and developed a prototype for a depth of 500 m aiming to development of own equipment required to secure deep subsurface characterization technologies. K-DEV is equipped with sensors that provide digital output with verified high performance; moreover, it is also compatible with logging winch systems used in Korea. The K-DEV prototype has a nonmagnetic stainless steel housing with an outer diameter of 48.3 mm, which has been tested in the laboratory for water resistance up to 20 MPa and for durability by running into a 1-km deep borehole. We confirmed the operational stability and data repeatability of the prototype by constantly logging up and down to the depth of 600 m. A high-precision micro-electro-mechanical system (MEMS) gyroscope was used for the K-DEV prototype as the gyro sensor, which is crucial for azimuth determination in cased holes. Additionally, we devised an accurate trajectory survey algorithm by employing Unscented Kalman filtering and data fusion for optimization. The borehole test with K-DEV and a commercial logging tool produced sufficiently similar results. Furthermore, the issue of error accumulation due to drift over time of the MEMS gyro was successfully overcome by compensating with stationary measurements for the same attitude at the wellhead before and after logging, as demonstrated by the nearly identical result to the open hole. We believe that the methodology of K-DEV development and operational stability, as well as the data reliability of the prototype, were confirmed through these test applications.