• 제목/요약/키워드: non-vacuum

검색결과 629건 처리시간 0.029초

Stereotactic Vacuum-Assisted Core Biopsy Results for Non-Palpable Breast Lesions

  • Agacayak, Filiz;Ozturk, Alper;Bozdogan, Atilla;Selamoglu, Derya;Alco, Gul;Ordu, Cetin;Pilanci, Kezban Nur;Killi, Refik;Ozmen, Vahit
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권13호
    • /
    • pp.5171-5174
    • /
    • 2014
  • Background: The increase in breast cancer awareness and widespread use of mammographic screening has led to an increased detection of (non-palpable) breast cancers that cannot be discovered through physical examination. One of the methods used in the diagnosis of these cancers is vacuum-assisted core biopsy, which prevents a considerable number of patients from undergoing surgical procedures. The aim of this study was to present the results of stereotactic vacuum-assisted core biopsy for suspicious breast lesions. Materials and Methods: Files were retrospectively scanned and data on demographic, radiological and pathological findings were recorded for patients who underwent stereotactic vacuum-assisted core biopsy due to suspicious mammographic findings at the Interventional Radiology Centre of the Florence Nightingale Hospital between January 2010, and April 2013. Statistical analysis was carried out using Pearson's Chi-square, continuity correction, and Fisher's exact tests. Results: The mean age of the patients was 47 years (range: 36-70). Biopsies were performed due to BIRADS 3 lesions in 8 patients, BIRADS 4 lesions in 77 patients, and BIRADS 5 lesions in 3 patients. Mammography elucidated clusters of microcalcifications in 73 patients (83%) and focal lesions (asymmetrical density, distortion) in 15 patients (17%). In terms of complications, 1 patient had a hematoma, and 2 patients had ecchymoses (3/88; 3.3%). The histopathologic results revealed benign lesions in 63 patients (71.6%) and malignant lesions in 25 patients (28.4%). The mean duration of the procedure was 37 minutes (range: 18-55). Although all of the BIRADS 3 lesions were benign, 22 (28.6%) of the BIRADS 4 lesions and all of the BIRADS 5 lesions were malignant. Among the malignant cases, 80% were in situ, and 20% were invasive carcinomas. These patients underwent surgery. Conclusions: In cases where non-palpable breast lesions are considered to be suspicious in mammography scans, the vacuum-assisted core biopsy method provides an accurate histopathologic diagnosis thus preventing a significant number of patients undergoing unnecessary surgical procedures.

Impact of Non-Calcified Specimen Pathology on the Underestimation of Malignancy for the Incomplete Retrieval of Suspicious Calcifications Diagnosed as Flat Epithelial Atypia or Atypical Ductal Hyperplasia by Stereotactic Vacuum-Assisted Breast Biopsy

  • Chi-Chang Yu;Yun-Chung Cheung;hir-Hwa Ueng;Shin-Cheh Chen
    • Korean Journal of Radiology
    • /
    • 제21권11호
    • /
    • pp.1220-1229
    • /
    • 2020
  • Objective: Stereotactic vacuum-assisted breast biopsy (VABB) is considered a reliable alternative to surgical biopsy for suspicious calcifications. In most cases, the management of flat epithelial atypia (FEA) and atypical ductal hyperplasia (ADH) after VABB with residual calcifications requires surgical excision. This study aimed to evaluate the impact of pathology of non-calcified specimens on the underestimation of malignancy. Materials and Methods: We retrospectively reviewed 1147 consecutive cases of stereotactic VABB of suspicious calcifications without mass from January 2010 to December 2016 and identified 46 (4.0%) FEA and 52 (4.5%) ADH cases that were surgically excised for the retrieval of residual calcifications. Mammographic features and pathology of the calcified and non-calcified specimens were reviewed. Results: Seventeen specimens (17.3%) were upgraded to malignancy. Mammographic features associated with the underestimation of malignancy were calcification extent (> 34.5 mm: odds ratio = 6.059, p = 0.026). According to the pathology of calcified versus non-calcified specimens, four risk groups were identified: Group A (ADH vs. high-risk lesions), Group B (ADH vs. non-high-risk lesions), Group C (FEA vs. high-risk lesions), and Group D (FEA vs. non-high-risk lesions). The lowest underestimation rate was observed in Group D (Group A vs. Group B vs. Group C vs. Group D: 35.0% vs. 20.0% vs. 15.0% vs. 3.6%, p = 0.041, respectively). Conclusion: Considering that the calcification extent and pathology of non-calcified specimens may be beneficial in determining the likelihood of malignancy underestimation, excision after FEA or ADH diagnosis by VABB is required, except for the diagnoses of FEA coexisting without atypia lesions in non-calcified specimens.

Development of an advanced atmospheric pressure plasma source with high spatial uniformity and selectiveness for surface treatment

  • 임유봉;최원호;이승훈;한우용;이종현;이상균;하정민;김종훈
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.176-177
    • /
    • 2016
  • In the last few decades, attention toward atmospheric pressure plasma (APP) has been greatly increased due to the numerous advantages of those applications, such as non-necessity of high vacuum facility, easy setup and operation, and low temperature operation. The practical applications of APP can be found in a wide spectrum of fields from the functionalization of material surfaces to sterilization of medical devices. In the secondary battery industry, separator film has been typically treated by APP to enhance adhesion strength between adjacent films. In this process, the plasma is required to have high stability and uniformity for better performance of the battery. Dielectric barrier discharge (DBD) was usually adopted to limit overcurrent in the plasma, and we developed the pre-discharge technology to overcome the drawbacks of streamer discharge in the conventional DBD source which makes it possible to produce a super-stable plasma at atmospheric pressure. Simulations for the fluid flow and electric field were parametrically performed to find the optimized design for the linear jet plasma source. The developed plasma source (Plasmapp LJPS-200) exhibits spatial non-uniformity of less than 3%, and the adhesion strength between the separator and electrode films was observed to increase 17% by the plasma treatment.

  • PDF

진공아크방전으로 제작된 다이아몬드상 탄소 박막이 코팅된 실리콘 전계 방출 소자의 전계 방출 특성 (Field emission properties of the silicon field emission arrays coated with diamond-like carbon film prepared by filtered cathodic vacuum arc technique)

  • 황한욱;김용상
    • 한국전기전자재료학회논문지
    • /
    • 제13권4호
    • /
    • pp.326-331
    • /
    • 2000
  • We have fabricated the field emitter arrays coated with diamond-like carbon (DLC) films that improved the field emission characteristics. The nitrogen doped DLC films are prepared by the filtered cathodic vacuum are (FCVA) tehnique. The activation energy of the nitrogen doped DLC films are derived from electrical conductivity measurements. The silicon field emission arrays (FEAs) were prepared by the VLSI technique. The turn-on field was rapidly decreasing and the emission current was remarkably increasing the DLC-coated FEAs than the non-coated silicon FEAs. In the nitrogen doped FEAs, the turn-on field decreased and the emission current increased with increasing the nitrogen found out the field emission current and the work function of the DLC-coated FEAs was remarkably decreased than that of the non-coated silicon FEAs. As nitrogen doping concentrations are increased the work function of FEAs is decreased and the field emission properties are improved in nitrogen doped DLC-coated FEAs. This phenomenon in due the fact that the Fermi energy level moves to the conduction band by increasing nitrogen doping concentration.

  • PDF

Characterization of a-C/B:H thin films for KSTAR boronization

  • Sun, Jong-Ho;Hong, Suk-Ho;Woo, Hyun-Jong;Park, Eun-Kyong;Kim, Hye-Ran;Chung, Kyu-Sun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.414-414
    • /
    • 2010
  • KSTAR vacuum vessel has been boronized by carborane ($C_2B_{10}H_{12}$) to reduce various kinds of impurities including carbon and oxygen from the wall, since carborane is solid, non-toxic, non-explosive and is easily evaporated, while diborane ($B_2D_6$) is toxic and explosive. To find the best wall condition for the removal of contaminants before application to KSTAR, various amounts (0.3g, 0.5g, 1g) of carborane are tested in a test chamber, where filament discharge was generated in the mixture of helium and carborane with the same KSTAR target pressure (~ 5 mTorr) from base pressure (${\sim}10^-7\;Torr$). Discharge is performed by a pulse sequence mode with 3 second power on and 5 second power off. Deposited films of a-C/B:H are characterized by ellipsometery, AES and XPS, and are compared with those of KSTAR.

  • PDF

Sterilization of Freeze Dried Manila Clam (Ruditapes philippinarum) Porridge for Immuno-Compromised Patients

  • Song, Beom-Seok;Park, Jae-Nam
    • 방사선산업학회지
    • /
    • 제10권4호
    • /
    • pp.205-210
    • /
    • 2016
  • This study was conducted to evaluate the combined effect of gamma irradiation and different conditions (vacuum packaging, antioxidant and freezing) on the microbiological and sensory characteristics of freeze dried Manila clam porridge (MCP) for immuno-compromised patient food. MCP can be sterilized at 1 kGy to 10 kGy. The initial counts of total aerobic bacteria and yeast molds in the non-irradiated MCP were $2.4{\pm}0.5$ and $1.2{\pm}0.3{\log}\;CFU\;g^{-1}$, respectively, but gamma irradiation significantly decreased the total aerobic bacteria to below the detection limit ($1{\log}\;CFU\;g^{-1}$) (5 kGy). Moreover, gamma irradiation effectively eliminated yeasts/molds at dose below than 1 kGy. However, gamma irradiation accelerated the increase of lipid oxidation and therefore, decreased the sensory characteristics of MCP as irradiation dose increased. To improve the sensory qualities of gamma irradiated MCP, combination treatment (vacuum packaging, 0.1% vitamin C) were applied. There was no significant difference in the overall acceptance scores between the combined-treatment sample (5.6 points) and the non-irradiated samples (6.0). The results indicate that combination treatment (vacuum packaging, 0.1% vitamin C) may help to maintain the quality of MCP. Therefore, it considered that irradiation of MCP with combined treatment and this is an effective method for the consumption as a special purpose food such as for space travel or immuno-compromised patients.

전자선조사와 포장방법이 발효소시지의 냉장 저장 중 품질 특성에 미치는 영향 (Combination Effect of Packaging and Electron Beam Irradiation on Quality Traits of Fermented Sausages During Storage)

  • 임동균;이무하
    • Journal of Animal Science and Technology
    • /
    • 제49권4호
    • /
    • pp.539-548
    • /
    • 2007
  • 본 실험은 전자선 조사와 포장방법을 병행하여 저장기간에 따른 발효소시지의 지질산화와 육색에 미치는 영향을 조사하였다. 발효, 숙성과정을 통해 얻어진 발효소시지를 총흡수선량이 2 kGy가 되도록 전자선 조사한 후 진공포장과 함기포장으로 나누어 4±1℃에서 저장하면서 실험을 수행하였다. 조사유무와 상관없이 저장 14일째 pH의 경우 진공포장처리구가 함기포장처리구보다 유의적으로 더 높은 수치를 보였다(p<0.05). 총균수와 젖산균수의 경우 저장기간에 따라 미생물수가 감소하였고, 함기포장의 경우 저장 7일차의 비조사구가 조사구(2 kGy)보다 미생물수가 유의적으로 더 높았다(p<0.05). 저장 TBA 값의 경우 조사구(2 kGy)가 비조사구보다 더 높았고, 진공포장한 시료의 TBA 값이 함기포장한 시료보다 더 낮았다(p<0.05). 저장기간에 따라 L*, a* 그리고 b* 값이 감소하는 경향을 나타내었고, 조사구(2 kGy)가 비조사구보다 a*와 b* 값이 더 높게 나타났다(p<0.05). 관능평가의 경우는 향기와 불쾌취에 있어 함기포장시료에서 조사구(2 kGy)가 비조사구보다 유의적으로 더 높은 수치를 나타내었다(p<0.05). 따라서 저장기간동안 비조사구보다 조사처리구(2 kGy)에서 훨씬 높은 산패도를 나타냈으며, 조사처리구(2kGy)의 경우 함기포장보다 진공포장시 지방산패도가 더 낮음을 확인하였다.