• Title/Summary/Keyword: non-thermal sterilization

Search Result 34, Processing Time 0.04 seconds

Sterilization effect of atmospheric pressure non-thermal air plasma on dental instruments

  • Sung, Su-Jin;Huh, Jung-Bo;Yun, Mi-Jung;Chang, Brian Myung W.;Jeong, Chang-Mo;Jeon, Young-Chan
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.1
    • /
    • pp.2-8
    • /
    • 2013
  • PURPOSE. Autoclaves and UV sterilizers have been commonly used to prevent cross-infections between dental patients and dental instruments or materials contaminated by saliva and blood. To develop a dental sterilizer which can sterilize most materials, such as metals, rubbers, and plastics, the sterilization effect of an atmospheric pressure non-thermal air plasma device was evaluated. MATERIALS AND METHODS. After inoculating E. coli and B. subtilis the diamond burs and polyvinyl siloxane materials were sterilized by exposing them to the plasma for different lengths of time (30, 60, 90, 120, 180 and, 240 seconds). The diamond burs and polyvinyl siloxane materials were immersed in PBS solutions, cultured on agar plates and quantified by counting the colony forming units. The data were analyzed using one-way ANOVA and significance was assessed by the LSD post hoc test (${\alpha}$=0.05). RESULTS. The device was effective in killing E. coli contained in the plasma device compared with the UV sterilizer. The atmospheric pressure non-thermal air plasma device contributed greatly to the sterilization of diamond burs and polyvinyl siloxane materials inoculated with E. coli and B. subtilis. Diamond burs and polyvinyl siloxane materials inoculated with E. coli was effective after 60 and 90 seconds. The diamond burs and polyvinyl siloxane materials inoculated with B. subtilis was effective after 120 and 180 seconds. CONCLUSION. The atmospheric pressure non-thermal air plasma device was effective in killing both E. coli and B. subtilis, and was more effective in killing E. coli than the UV sterilizer.

Quality Characteristics and Functionality of Low Alcohol Wines after Heat Sterilization and Non-Thermal Sterilization (저알코올 와인의 가열 및 비가열 살균 후 품질 특성 및 기능성)

  • Shin, Hyerim;Park, Hyejin;Hwang, On Bit;Choi, Sungyeol;Park, Eui Kwang;Yoon, Dong Kyu;Yoon, Hyang-Sik
    • The Korean Journal of Food And Nutrition
    • /
    • v.35 no.5
    • /
    • pp.343-352
    • /
    • 2022
  • Low alcohol (6%) wines were manufactured using Campbell Early. To develop the sterilization process of low alcohol wines, red wines were heat sterilized, and rose wines were nonthermal sterilized by concentration using potassium metasulfite and potassium sorbate. Samples were stored at 25℃ and quality characteristics were investigated by period. Results of this study revealed the pH of the samples after sterilization ranged from 3.15 to 3.19, and the total acidity of wines ranged from 0.011 to 0.024%. The free SO2 contents of wines ranged from 13.00 to 29.678 mg/L, and the total SO2 contents of wines ranged from 47.50 to 121.00 mg/L. L (lightness) of wines decreased whereas a (redness) and b(yellowness) increased. The hue value of wines ranged from 0.52 to 1.03, and decreased significantly(not including rose sweet wines). The color intensity of red and rose dry wines after sterilization increased, whereas red and rose sweet wines decreased. The DPPH radical scavenging activity of red wines and rose wines ranged between 75.50 to 89.23%, and 36.60 to 56.54%, respectively. The total polyphenol contents were 57.51~182.63 mg%. Results of this study provide scientific information to establish the sterilization process of low alcohol wines.

Development of the High Voltage Converter for the Pulsed Light Sterilization (광펄스 살균을 위한 다채널 고전압 컨버터의 개발)

  • Lee, Young-Woo;Kim, Hyung-Won;Choi, Woo-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.6
    • /
    • pp.29-37
    • /
    • 2012
  • As the demand for the fresh non-thermal food is increased, it is required to develop the fast and perfect sterilization method. The conventional sterilization method using ultraviolet lamp has some disadvantages such as imperfect sterilization and longer process time. In this research, IPL(Intense Pulsed Light) sterilization system is introduced to overcome the drawbacks of the conventional system, and suitable power supply architecture for the system is discussed. Since the IPL sterilization system uses Zenon lamps which requires the 600~2,100[V] for the lightning and 16~30[kV] for the trigger, the converter for the system should be able to generate the high voltage and to discharge the large amount of energy instantaneously. In this research a new power system architecture which has a modified forward converter topology with two switches for generating high voltage and a capacitor bank to control the energy for the lightning by switching is introduced.

Sterilization of Food-Borne Pathogenic Bacteria by Atmospheric Pressure Dielectric Barrier Discharge Plasma (대기압 유전체장벽방전 플라즈마에 의한 식품유해 미생물 살균)

  • Lee, Seung Je;Song, Yoon Seok;Park, Yu Ri;Ryu, Seung Min;Jeon, Hyeong Won;Eom, Sang Heum
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.3
    • /
    • pp.222-227
    • /
    • 2017
  • This study aimed to explore the potential for food-industry application of atmospheric pressure dielectric barrier discharge plasma (atmospheric pressure DBD plasma) as a non-thermal sterilization technology for microorganism. The effects of the key parameters such as power, oxygen ratio, exposure time and distance on Escherichia coli KCCM 21052 sterilization by the atmospheric pressure DBD plasma treatment were investigated. The experimental results revealed that increasing the power, exposure time or oxygen ratio and decreasing the exposure distance led to an improvement in the sterilization efficiency of E. coli. Furthermore, the atmospheric pressure DBD plasma (1.0 kW power, 1.0% (v/v) $O_2$, 5 min exposure time and 20 mm exposure distance) treatment was very effective for the sterilization of food-borne pathogenic bacteria. The sterilization rate of E. coli, Bacillus cereus KCCM 40935, Bacillus subtilis KCCM 12027, Bacillus thuringiensis KCCM 11429 and Bacillus atrophaeus KCCM 11314 were 72.3%, 74.6%, 88.5%, 84.7% and 91.3%, respectively.

Current status of research on microbial disinfection of food using ultrasound (초음파를 활용한 식품 살균 기술의 연구 현황)

  • Song, Kyung-Mo
    • Food Science and Industry
    • /
    • v.53 no.3
    • /
    • pp.277-283
    • /
    • 2020
  • Microbial disinfection is essential to increase the preservation and safety of food. In general, thermal sterilization technology is most frequently used, but it often causes nutrient denaturation, and deterioration of food quality. Accordingly, non-thermal sterilization using a novel technology is emerging as an alternative technology. Among them, ultrasonic technology produces a disinfection effect by promoting the destruction of microorganisms by cavitation. Ultrasound technology alone has a low effect, so research is being actively conducted to develop an effective technology by applying as a hurdle technology with various other technologies. Ultrasound can be treated with various processes including traditional sterilization methods such as heating, high pressure, and chemical treatment, as well as novel technologies such as ultraviolet irradiation. Ultrasound assisted sterilization technology still remains at the laboratory level, requiring additional research such as the development of equipment for industrial application and establishment of an optimal process.

Comparison of UV-Irradiation and High Hydrostatic Pressure Sterilization for Storage Stability of Carrot Juice (UV살균과 초고압살균에 의한 당근주스의 저장성 비교)

  • Oh, Nam Seok;Kim, Min Young;Jang, Gwi Young;Baek, So Yune;Joung, Mi Yeun;Kang, Tae Su;Lee, Junsoo;Jeong, Heon Sang
    • The Korean Journal of Food And Nutrition
    • /
    • v.30 no.5
    • /
    • pp.1113-1118
    • /
    • 2017
  • The objective of this study was to investigate the non-thermal sterilization effect of methods such as high hydrostatic pressure (HHP) and UV-irradiation (specifically with regard to the storage stability and shelf-life of carrot juice. The microbial counts of the non-sterilized product increased from 5.51 to 7.34 log CFU/mL up to the fifth day, and then decreased to 5.46 log CFU/mL at six days. UV-irradiation was increased from 2.37 to 4.92 log CFU/mL. HHP was maintained under the 3 log CFU/mL. The pH of UV-irradiation and HHP was maintained withing the range of 6.29~6.30 and 6.20~6.22 during storage. However, the pH arising from non-sterilization decreased from 6.31 to 4.49. The color of non-sterilization changed significantly during storage, but UV-irradiation and HHP were similar during storage. The ${\beta}$-carotene content of non-sterilization was noted to have decreased from 269.45 to $65.19{\mu}g/mL$ during storage. The UV-irradiation and HHP decreased from 263.46 and $268.35{\sim}281.16{\mu}g/mL$ to 243.42 and $244.09{\sim}269.29{\mu}g/mL$, respectively. In conclusion, these findings suggest that HHP can be used for the pasteurization, or sterilization, of carrot juice and the optimal condition is two minutes.

Antimicrobial Activity and Mechanism of Supercritical Fluids (초임계 유체의 미생물 불활성화 특성 및 기작)

  • Mun, Sungmin;Kim, Jungchan;Lee, Youn-Woo;Yoon, Jeyong
    • Applied Chemistry for Engineering
    • /
    • v.22 no.5
    • /
    • pp.453-460
    • /
    • 2011
  • Recently, there is growing interests in the application of supercritical fluids for food and medical fields since supercritical fluids ($CO_2$ and $N_2O$) have known to be safe and effective as a non-thermal sterilization technique. Although supercritical fluids have been investigated for various kinds of products, they have not yet been used in common currency due to their lack of knowledge related to the antimicrobial activity or detailed mechanisms. In this review paper, we summarized the characteristics, antimicrobial activity and mechanisms, important factors, and applicability of supercritical fluids to help the investigation and commercialization of supercritical fluids sterilization technique.

Effect of Acid Soaking and Thermal Sterilization on the Shape and Quality Characteristics of Tteokbokki Rice Cake (산침지와 가열 살균이 떡볶이 떡의 형상 변화와 품질 특성에 미치는 영향)

  • Jung, Hwabin;Yu, Chae Rin;Park, Hyeon Woo;Yoon, Won Byong
    • The Korean Journal of Food And Nutrition
    • /
    • v.31 no.5
    • /
    • pp.737-750
    • /
    • 2018
  • Effects of acid soaking (AS) and thermal sterilization (TS) on the shape and quality characteristics of Tteokbokki rice cake (TRC) were investigated. The F-value of a sequential process (SP) of the combination of AS and TS was quantitatively determined with a reference microorganism of Bacillus cereus. F-values were evaluated according to the minimum and the maximum D-value of B. cereus and the reduction exponent (m=12). The heat penetration curves at cold point (CP) of TRC (400 g) were used to estimate the TS time at 121, 100, and $95^{\circ}C$. F-values of the SP were revised according to the adjusted m values after AS at different pH. The non-uniformity parameters (NUP) of TRC had no significant changes during AS but it dramatically increased after applying TS at a low pH by AS. The result of solubilized starch contents (SSC) demonstrated that the shape changes during SP are related to SSC. The texture characteristics and the whiteness were significantly influenced by a low pH condition (3.5) (p<0.05). Sensory analysis showed that a lower pH and a longer thermal processing time influenced negatively on the acceptability. This study showed that pH 4.0 and $95^{\circ}C$ was an optimum condition for the SP.

Microbial Inactivation in Kimchi Saline Water Using Microwave Plasma Sterilization System (Microwave Plasma Sterilization System을 이용한 배추 절임수의 미생물 저감화)

  • Yu, Dong-Jin;Shin, Yoon-Ji;Kim, Hyun-Jin;Song, Hyeon-Jeong;Lee, Ji-Hye;Jang, Sung-Ae;Jeon, So-Jung;Hong, Soon-Taek;Kim, Sung-Jae;Song, Kyung-Bin
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.1
    • /
    • pp.123-127
    • /
    • 2011
  • This study was conducted to decrease the microbial hazard in kimchi saline water with microwave plasma sterilization system and to evaluate the inactivation of foodborne pathogens by the microwave plasma sterilization system as a non-thermal treatment. Contamination of coliform, Escherichia coli, and yeasts and molds were detected in the used saline water, and the microbial populations increased as the saline water was reused repeatedly. The $D_{10}$-values of E. coli O157:H7, Salmonella Typhimurium, and Listeria monocytogenes by the microwave plasma sterilization system were 0.48, 0.52, and 0.45 cycle, respectively. In addition, the microbial populations of coliform, E. coli, Salmonella spp., total aerobic bacteria, and yeasts and molds in the used kimchi saline water were significantly decreased by treating the saline water using the microwave plasma sterilization system. Therefore, these results suggest that microwave plasma sterilization system can be useful in improving the microbial safety of the used saline water.

Recent Research on and Development of Thermal and Pulsed Electric Field Systems for Pasteurization of Milk and Milk Products (우유 및 유제품의 열처리 및 펄스 전기장 살균 최근 연구 개발 동향)

  • Kang, Shin-Ho;Shin, Yong Kook
    • Journal of Dairy Science and Biotechnology
    • /
    • v.32 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • Thermal pasteurization has been effectively used for decades as a method to extend the shelf life of milk and to inactivate any pathogenic bacteria that it may contain; however, it can negatively affect the nutritional properties of milk. In recent years, the food industry has sought new, less aggressive technologies that affect food freshness and its nutritive and health benefits less significantly. Various means have been used to extend the shelf life of dairy foods, such as high-pressure processing, irradiation, ohmic heating, and pulsed electric field (PEF) technologies. Of these, PEF technologies are potential alternatives to traditional thermal milk pasteurization, owing to their advantages in minimizing sensory and nutritional damage. In this review, we have primarily focused on the feasibility of applying PEF technologies to the sterilization of dairy products and briefly discussed whether they should be adopted for use in the dairy beverage industry in the future.

  • PDF