• 제목/요약/키워드: non-testing methods

검색결과 489건 처리시간 0.024초

Advanced Indentation System을 이용한 천연가스배관 용접열영향부의 응력-변형률 변화 특성 분석 (Evaluation of Stress-Strain Characteristics of Weldment in Natural Gas Pipeline Using Advanced Indentation System)

  • 장재일;손동일;권동일;김우식;박주승
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.483-488
    • /
    • 2001
  • Until now, the tensile properties of materials can be obtained just in accordance with conventional tensile testing methods which are described in several standards such as ASTM (American Society for Testing and Materials) standard and BS (British Standard). For some cases including on-service facility materials, however, the standard testing methods cannot be applicable due to the destructive testing procedure and specimen size requirement. Therefore, simple, non-destructive and advanced indentation technique was proposed. This test measures indentation load-depth curve during indentation and analyzes the mechanical properties related to deformation and fracture. In this paper, the research trend of non-destructive evaluation of tensile properties using AIS (advanced indentation system) and its application fields are reviewed and discussed.

  • PDF

Detection of Damages in Concrete Structures Using Non-Contact Air-Coupled Sensing Methods

  • Shin, Sung-Woo
    • 비파괴검사학회지
    • /
    • 제30권3호
    • /
    • pp.282-289
    • /
    • 2010
  • Most nondestructive testing techniques require good contact between the sensor and tested concrete surface to obtain reliable data. But the surface preparation is often very time and labor consuming due to the rough surface or limited access of concrete structures. One approach to speed up the data collection process is to eliminate the need for physical contact between the sensor and tested structure. Non-contact air-coupled sensing technique can be a good solution to this problem. An obvious advantage of the non-contact air-coupled sensing technique is which can greatly speed up the data collection in field and thus the damage detection process can be completed very rapidly. In this article, recent developments in non-contact air-coupled sensing technique for rapid detection of damages in concrete structures are summarized to evoke interest, discussion and further developments on this technique to a NDT research community in Korea. It is worth noting that the works in this article have been published in the types of thesis, proceedings, and journals. All published sources are cited in the text and listed in reference.

異性材料 마찰용접부의 기계적 성질검사 (Testing of Mechanical Properties on Dissimilar Metal Friction Welds)

  • 나석주
    • 대한기계학회논문집
    • /
    • 제8권1호
    • /
    • pp.41-47
    • /
    • 1984
  • Increase of the requirements on quality of welded structures necessitates the improvement of known inspection methods and the introduction of progressive new techniques. Non-destructive methods are the most advanced, but there are considerable difficulties in using the methods of radiography with electromagnetic rays and ultrasonic testing in the inspection of dissimilar metal friction welds, because their physical and mechanical properties are changed very rapidly at the interface. The values of simple mechanical test for dissimilar metal friction welds have always been dubious, as the strength of the bond is often greater than that of the softer materials being jointed. Thus, in this paper some conventional mechanical testing methods are examined in an attempt to determine a technique for dissimilar metal friction welds, which will give a reliable quantitative indication of the weld quality. From the considered static and dynamic testing methods the impact bending test on unnotched and notched specimens are the most sensitive to find out the small joining defects in the interface.

Upper Bounds for the Infection Rate in Group Testing

  • Kwan, Se-hyug
    • Communications for Statistical Applications and Methods
    • /
    • 제4권1호
    • /
    • pp.317-325
    • /
    • 1997
  • Group testing is an efficient method to classify units from a population as infected or non-infected and useful in estimating the infection rate when the population infection rate is small. Upper bounds are the focus of interest in group testing, but has not been studied extensively. In this paper, the upper bound derived from the uniformly most powerful test is proposed and compared with the classical approachers, Thompson's and Bhattacharyya et al.'s methods.

  • PDF

비파괴시험을 이용한 현장타설말뚝의 건전도 평가에 관한 연구 (Application of Non-Destructive Testing Techniques to the Evaluation of Integrity of Drilled Shaft)

  • 채종훈;유재명;김대규;이우진
    • 한국지반환경공학회 논문집
    • /
    • 제2권4호
    • /
    • pp.5-14
    • /
    • 2001
  • 최근 구조물기초에 큰 변형 및 손상을 가하지 않고 안정성에 대한 정보를 비교적 쉽게 얻을 수 있는 비파괴시험(NDT, Non-Destructive Testing)기법이 큰 관심을 얻고 있다. 본 연구에서는 비파괴시험 중 검측공 기법(CSL, CT, PS)과 표면파 기법(SE, IR)을 현장타설말뚝의 건전도 평가에 이용하기 위한 적용성의 문제를 현장시험을 통하여 고찰하였다. 이를 위하여 결함이 없는 한 본의 정상말뚝과 연약선단, 단면축소 확대, 불량콘크리트 타설 등 현장에서 발생하기 쉬운 결함의 종류, 크기, 위치 등을 변화 조합한 9본의 현장타설말뚝(직경 0.4m, 길이 7.0m)을 시공하여 다양한 비파괴시험을 수행하였다. 시험을 통하여 각 기법을 현장타설말뚝의 건전도 평가에 적용할 때의 문제점과 각 기법의 합리적인 조합에 대하여 고찰하였다.

  • PDF

Estimation in Group Testing when a Dilution Effect exists

  • Kwon, Se-Hyug
    • Communications for Statistical Applications and Methods
    • /
    • 제13권3호
    • /
    • pp.787-794
    • /
    • 2006
  • In group testing, the test unit consists of a group of individuals and each group is tested to classify units from a population as infected or non-infected or estimate the infection rate. If the test group is infected, one or more individuals in the group are presumed to be infected. It is assumed in group testing that classification of group as positive or negative is without error. But, the possibility of false negatives as a result of dilution effects happens often in practice, specially in many clinical researches. In this paper, dilution effect models in group testing are discussed and estimation methods of infection rate are proposed when a dilution effect exists.

Predicting the Firmness of Apples using a Non-contact Ultrasonic Technique

  • Lee, Sangdae;Park, Jeong-Gil;Jeong, Hyun-Mo;Kim, Ki-Bok;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • 제38권3호
    • /
    • pp.192-198
    • /
    • 2013
  • Purpose: Methods for non-destructive estimation of product quality have been reported in various industrial fields, but the application of ultrasonic techniques for the agricultural products of potatoes, pears, apples, watermelons, kiwis and tomatoes etc. have been rarely reported since the application of a contact-type ultrasonic transducer in agricultural products is very difficult. Therefore, this study sought to determine the firmness of apples using non-contact ultrasonic techniques. Methods: For this experiment, an ultrasonic experimental tester using a non-contact ultrasonic transducer was created, and a signal processing program was used to analyze the acquired ultrasonic reflected signal. Also, a universal testing machine was used to measure firmness parameters of the apples such as bioyield strength, a firmness factor, after the ultrasonic tests had been performed. Results: Six distance correction factors were calculated to obtain consistent values of ultrasonic properties regardless of the distance between the transducer and the surface of the subject. We developed prediction models of the bioyield strength using the distance correction factors. Conclusions: The optimum prediction model of the bioyield strength of apples using a non-contact ultrasonic technique was a multiple regression model ($R^2=0.9402$).

Defect Monitoring In Railway Wheel and Axle

  • Kwon, Seok-Jin;Lee, Dong-Hyoung;You, Won-Hee
    • International Journal of Railway
    • /
    • 제1권1호
    • /
    • pp.1-5
    • /
    • 2008
  • The railway system requires safety and reliability of service of all railway vehicles. Suitable technical systems and working methods adapted to it, which meet the requirements on safety and good order of traffic, should be maintained. For detection of defects, non-destructive testing methods-which should be quick, reliable and cost-effective - are most often used. Since failure in railway wheelset can cause a disaster, regular inspection of defects in wheels and axles are mandatory. Ultrasonic testing, acoustic emission and eddy current testing method and so on regularly check railway wheelset in service. However, it is difficult to detect a crack initiation clearly with ultrasonic testing due to noise echoes. It is necessary to develop a non-destructive technique that is superior to conventional NDT techniques in order to ensure the safety of railway wheelset. In the present paper, the new NDT technique is applied to the detection of surface defects for railway wheelset. To detect the defects for railway wheelset, the sensor for defect detection is optimized and the tests are carried out with respect to surface and internal defects each other. The results show that the surface crack depth of 1.5 mm in press fitted axle and internal crack in wheel could be detected by using the new method. The ICFPD method is useful to detect the defect that initiated in railway wheelset.

  • PDF

비파괴충격파 시험법을 이용한 동탄성계수 평가 (Evaluation of the Dynamic Modulus by using the Impact Resonance Testing Method)

  • 김도완;장병관;문성호
    • 한국도로학회논문집
    • /
    • 제16권3호
    • /
    • pp.35-41
    • /
    • 2014
  • PURPOSES : The dynamic modulus for a specimen can be determined by using either the non-destructed or destructed testing method. The Impact Resonance Testing (IRT) is the one of the non-destructed testing methods. The MTS has proved the source credibility and has the disadvantages which indicate the expensive equipment to operate and need a lot of manpower to manufacture the specimens because of the low repeatability with an experiment. To overcome these shortcomings from MTS, the objective of this paper is to compare the dynamic modulus obtained from IRT with MTS result and prove the source credibility. METHODS : The dynamic modulus obtained from IRT could be determined by using the Resonance Frequency (RF) from the Frequency Response Function (FRF) that derived from the Fourier Transform based on the Frequency Analysis of the Digital Signal Processing (DSP)(S. O. Oyadigi; 1985). The RF values are verified from the Coherence Function (CF). To estimate the error, the Root Mean Squared Error (RMSE) method could be used. RESULTS : The dynamic modulus data obtained from IRT have the maximum error of 8%, and RMSE of 2,000MPa compared to the dynamic modulus measured by the Dynamic Modulus Testing (DMT) of MTS testing machine. CONCLUSIONS : The IRT testing method needs the prediction model of the dynamic modulus for a Linear Visco-Elastic (LVE) specimen to improve the suitability.

A Simulation Approach for Testing Non-hierarchical Log-linear Models

  • Park, Hyun-Jip;Hong, Chong-Sun
    • Communications for Statistical Applications and Methods
    • /
    • 제6권2호
    • /
    • pp.357-366
    • /
    • 1999
  • Let us assume that two different log-linear models are selected by various model selection methods. When these are non-hierarchical it is not easy to choose one of these models. In this paper the well-known Cox's statistic is applied to compare these non-hierarchical log-linear models. Since it is impossible to obtain the analytic solution about the problem we proposed a alternative method by extending Pesaran and pesaran's (1993) simulation approach. We find that the values of proposed test statistic and the estimates are very much stable with some empirical results.

  • PDF