• Title/Summary/Keyword: non-testing methods

Search Result 489, Processing Time 0.022 seconds

Experimental Study on the Aerodynamic Characteristics of a Two-Stage and a Counter-Rotating Axial Flow Fan (2단 축류홴과 엇회전식 축류홴의 공력특성에 관한 실험적 연구)

  • Cho, Jin-Soo;Cho, Lee-Sang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.10
    • /
    • pp.1281-1292
    • /
    • 2001
  • Experiments were done for the comparison of performance and flow characteristics between a two -stage axial flow fan and a counter-rotating axial flow fan. Each stage of the two -stage axial flow fan used fur the present study has an eight bladed rotor and thirteen slater blades. The front and the rear rotor of the counter - rotating axial flow fan have eight blades each and are driven by coaxial counter ro latins shafts through a gearbox located between the rear rotor and the electric motor. Both of the two axial fan configurations have identical rotor blades and the same operating condition fur the one -to-one comparison of the two. Performance curves of the two configurations were obtained and compared by varying the blade pitch angles and axial gaps between the blade rows. The fan characteristic curves were obtained following the Korean Standard Testing Methods for Turbo Fans and Blowers (KS B 6311). The fa n flow characteristics were measured using a five-hole probe by a non-nulling method. The velocity profiles between the hub and tip of the fans were measured and analyzed at the particular operating condition s of peak efficiency, minimum and maximum pressure coefficients. The peak efficiency of the counter-rotating axial fan was improved about 2% respectively, compared with the two stage axial fan. At the minimum pressure coefficient point of the two stage axial fan, the fan inlet flow patterns show that axial velocity highly decreased in the vicinity of the blade tip region. Also, the reverse flow took place at the blade tip.

Quality monitoring of complex manufacturing systems on the basis of model driven approach

  • Castano, Fernando;Haber, Rodolfo E.;Mohammed, Wael M.;Nejman, Miroslaw;Villalonga, Alberto;Lastra, Jose L. Martinez
    • Smart Structures and Systems
    • /
    • v.26 no.4
    • /
    • pp.495-506
    • /
    • 2020
  • Monitoring of complex processes faces several challenges mainly due to the lack of relevant sensory information or insufficient elaborated decision-making strategies. These challenges motivate researchers to adopt complex data processing and analysis in order to improve the process representation. This paper presents the development and implementation of quality monitoring framework based on a model-driven approach using embedded artificial intelligence strategies. In this work, the strategies are applied to the supervision of a microfabrication process aiming at showing the great performance of the framework in a very complex system in the manufacturing sector. The procedure involves two methods for modelling a representative quality variable, such as surface roughness. Firstly, the hybrid incremental modelling strategy is applied. Secondly, a generalized fuzzy clustering c-means method is developed. Finally, a comparative study of the behavior of the two models for predicting a quality indicator, represented by surface roughness of manufactured components, is presented for specific manufacturing process. The manufactured part used in this study is a critical structural aerospace component. In addition, the validation and testing are performed at laboratory and industrial levels, demonstrating proper real-time operation for non-linear processes with relatively fast dynamics. The results of this study are very promising in terms of computational efficiency and transfer of knowledge to manufacturing industry.

The Study on Relation of Obesity and Low Back Pain Based on Body Composition using Segmental Bioelectrical Impedance Analysis and Radiological Parameter (체성분 분석 변수와 X-선 소견을 근거로 한 비만과 요통의 관계 연구)

  • Park, Ji-Hyun;Hong, Seo-Young
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.19 no.2
    • /
    • pp.289-302
    • /
    • 2009
  • Objectives : This study was performed in order to investigate the relation of body composition analysis and radiological parameter(lumbosacral angle, lumbar lordortic angle, lumbar gravity line). Methods : This study was carried out with the data from comprehensive medical testing. 75 subject aged 20-59 performed the segmental bioelectrical impedance analysis, questionnaire. And lumbosacral angle, lumbar lordortic angle and lumbar gravity line were measured in the standing position x-ray. Then we analyzed the data. Results : Low back pain(LBP) prevalence in high obesity index(Body Mass Index(BMI), Percentage of Body Fat(PBF), Waist Hip Ratio(WHR)) group was higher than LBP prevalence in normal obesity index group(p<0.01). In LBP group, lumbosacral angle, lumbar lordortic angle were significantly lager than Non-LBP group(p<0.001). And 75% of LBP group indicated abnormal lumbar gravity line ratio(0.67 < Normal lumbar gravity line ratio <1.00). When it comes to analyze relation between obesity index and radiological parameter, no-significant change was seen. Conclusions : This study carried as following research after the study on relation of obesity, LBP and trunk muscle strength. Results from this investigation showed positive correlation between obesity and LBP prevalence. But obesity index didn't indicate significant correlation with structural changes of lumbar vertebrae. When considering prior research, trunk muscle strength changes were more related to LBP prevelence in obese people. This results are expected to explain causes of LBP in obese group.

An Effectiveness Verification for Evaluating the Amount of WTCI Tongue Coating Using Deep Learning (딥러닝을 이용한 WTCI 설태량 평가를 위한 유효성 검증)

  • Lee, Woo-Beom
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.4
    • /
    • pp.226-231
    • /
    • 2019
  • A WTCI is an important criteria for evaluating an mount of patient's tongue coating in tongue diagnosis. However, Previous WTCI tongue coating evaluation methods is a most of quantitatively measuring ration of the extracted tongue coating region and tongue body region, which has a non-objective measurement problem occurring by exposure conditions of tongue image or the recognition performance of tongue coating. Therefore, a WTCI based on deep learning is proposed for classifying an amount of tonger coating in this paper. This is applying the AI deep learning method using big data. to WTCI for evaluating an amount of tonger coating. In order to verify the effectiveness performance of the deep learning in tongue coating evaluating method, we classify the 3 types class(no coating, some coating, intense coating) of an amount of tongue coating by using CNN model. As a results by testing a building the tongue coating sample images for learning and verification of CNN model, proposed method is showed 96.7% with respect to the accuracy of classifying an amount of tongue coating.

Study on the Improvement of the Image Analysis Speed in the Digital Image Correlation Measurement System for the 3-Point Bend Test

  • Choi, In Young;Kang, Young June;Hong, Kyung Min;Kim, Seong Jong;Lee, Gil Dong
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.523-530
    • /
    • 2014
  • Machine material and structural strain are critical factors for appraising mechanical properties and safety. Particularly in three and four-point bending tests, which appraise the deflection and flexural strain of an object due to external force, measurements are made by the crosshead movement or deflection meter of a universal testing machine. The Digital Image Correlation (DIC) method is one of the non-contact measurement methods. It uses the image analyzing method that compares the reference image with the deformed image for measuring the displacement and strain of the objects caused by external force. Accordingly, the advantage of this method is that the object's surface roughness, shape, and temperature have little influence. However, its disadvantage is that it requires extensive time to compare the reference image with the deformed image for measuring the displacement and strain. In this study, an algorithm is developed for DIC that can improve the speed of image analysis for measuring the deflection and strain of an object caused by a three-point bending load. To implement this algorithm for improving the speed of image analysis, LabVIEW 2010 was used. Furthermore, to evaluate the accuracy of the developed fast correlation algorithm, the deflection of an aluminum specimen under a three-point bending load was measured by using the universal test machine and DIC measurement system.

Low-level laser therapy affects osseointegration in titanium implants: resonance frequency, removal torque, and histomorphometric analysis in rabbits

  • Kim, Jong-Ryoul;Kim, Sung-Hee;Kim, In-Ryoung;Park, Bong-Soo;Kim, Yong-Deok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.1
    • /
    • pp.2-8
    • /
    • 2016
  • Objectives: The purpose of this study was to investigate the effects of low-level laser therapy (LLLT) with a diode gallium-aluminum-arsenide (Ga-Al-As) low-level laser device on the healing and attachment of titanium implants in bone. Materials and Methods: Thirteen New Zealand white male rabbits weighing $3.0{\pm}0.5kg$ were used for this study. Dental titanium implants (3.75 mm in diameter and 8.5 mm in length, US II RBM plus fixture; Osstem, Seoul, Korea) were implanted into both femurs of each rabbit. The rabbits were randomly divided into a LLLT group and a control group. The LLLT was initiated immediately after surgery and then repeated daily for 7 consecutive days in the LLLT group. Six weeks and 12 weeks after implantation, we evaluated and compared the osseointegration of the LLLT group and control group, using histomorphometric analysis, removal torque testing, and resonance frequency analysis (RFA). The results were statistically significant when the level of probability was 0.05 or less based on a non-parametric Mann-Whitney U-test. Results: The implant survival rate was about 96%. Histologically and histomorphometrically, we observed that the titanium implants were more strongly attached in LLLT group than in control group. However, there was no significant difference between the LLLT group and control group in removal torque or RFA. Conclusion: Histologically, LLLT might promote cell-level osseointegration of titanium implants, but there was no statistically significant effects.

COMPARATIVE STUDY ON THE FRACTURE STRENGTH OF METAL-CERAMIC VERSUS COMPOSITE RESIN-VENEERED METAL CROWNS IN CEMENT-RETAINED IMPLANT-SUPPORTED CROWNS UNDER VERTICAL COMPRESSIVE LOAD

  • Pae, Ahran;Jeon, Kyung-A;Kim, Myung-Rae;Kim, Sung-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.295-302
    • /
    • 2007
  • Statement of problem. Fracture of the tooth-colored superstructure material is one of the main prosthetic complications in implant-supported prostheses. Purpose. The purpose of this in vitro study was to compare the fracture strength between the cement-retained implant-supported metal-ceramic crowns and the indirect composite resinveneered metal crowns under the vertical compressive load. Material and methods. Standard implants of external type (AVANA IFR 415 Pre-mount; Osstem Co., Busan, Korea) were embedded in stainless steel blocks perpendicular to their long axis. Customized abutments were fabricated using plastic UCLA abutments (Esthetic plastic cylinder; Osstem Co., Busan, Korea). Thirty standardized copings were cast with non-precious metal (Rexillium III, Pentron, Walling ford, Conn., USA). Copings were divided into two groups of 15 specimens each (n = 15). For Group I specimens, metal-ceramic crowns were fabricated. For Group II specimens, composite resin-veneered (Sinfony, 3M-ESPE, St. Paul, MN, USA) metal crowns (Sinfony-veneered crowns) were fabricated according to manufacturer's instructions. All crowns were temporary cemented and vertically loaded with an Instron universal testing machine (Instron 3366, Instron Corp., Norwood, MA, USA). The maximum load value (N) at the moment of complete failure was recorded and all data were statistically analyzed by independent sample t-test at the significance level of 0.05. The modes of failure were also investigated with visual analysis. Results. The fracture strength of Sinfony-veneered crowns ($2292.7{\pm}576.0N$) was significantly greater than that of metal-ceramic crowns ($1150.6{\pm}268.2N$) (P < 0.05). With regard to the failure mode, Sinfony-veneered crowns exhibited adhesive failure, while metal-ceramic crowns tended to fracture in a manner that resulted in combined failure. Conclusion. Sinfony-veneered crowns demonstrated a significantly higher fracture strength than that of metal-ceramic crowns in cement-retained implant-supported prostheses.

Characteristics of Corrosion Damages in Bottom Plate of Above Ground Tank by Acoustic Emission Signal (지상탱크 저판부의 부식손상 평가를 위한 음향방출 신호의 분석)

  • Kim, Sung-Dai;Jung, Woo-Gwang;Lee, Jong-O
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.64-72
    • /
    • 2007
  • Under the AE methods, the valid condition analysis and evaluation the leak etc, resulted by the AE signal pattern on the bottom plate of ground tank at full. In next more, the gradient of accumulation amplitude distribution analysis and comparison the energy, count, and duration time that noise of EMI signal were removed. EMI signal showed height-energy, count, and duration time, it also appeared great gradient of accumulation distribution. Then, with the pure remaining AE signals cluster analysis and location. It would possibly assume of damage with corrosion. Total cluster 20 and energy showed between the maximum 11,990 and 8,565 which is much lower than above figure and event number showed from 8 to 5. Even when it difficult to certify damage by open, as it is raised higher height-sensitivity and threshold by 60 dB. It would possibly presume of location source more accurately.

  • PDF

Altered Peripheral Nerve Excitability Properties in Acute and Subacute Supratentorial Ischemic Stroke (급성 및 아급성 천막상 허혈성 뇌졸중에서 발생하는 말초신경 흥분성 변화)

  • Seo, Jung Hwa;Ji, Ki Whan;Chung, Eun Joo;Kim, Sang Gin;Kim, Oeung Kyu;Paeing, Sung Hwa;Bae, Jong Seok
    • Annals of Clinical Neurophysiology
    • /
    • v.14 no.2
    • /
    • pp.64-71
    • /
    • 2012
  • Background: It is generally accepted that upper motor neuron (UMN) lesion can alter lower motor neuron (LMN) function by the plasticity of neural circuit. However there have been only few researches regarding the axonal excitability of LMN after UMN injury especially during the acute stage. The aim of this study was to investigate the nerve excitability properties of the LMNs following an acute to subacute supratentorial corticospinal tract lesion. Methods: An automated nerve excitability test (NET) using the threshold tracking technique was utilized to measure multiple excitability indices in median motor axons of 15 stroke patients and 20 controls. Testing of both paretic and non-paretic side was repeated twice, during the acute stage and subacute stage. The protocols calculated the strength-duration time constant from the duration-charge curve, parameters of threshold electrotonus (TE), the current-threshold relationship from sequential sub-threshold current, and the recovery cycle from sequential supra-threshold stimulation. Results: On the paretic side, compared with the control group, significant decline of superexcitablity and increase in the relative refractory period were observed during the subacute stage of stroke. Additionally, despite the absence of statistical significance, a mildly collapsing in ('fanning in') of the TE was found. Conclusions: Our results suggest that supratentorial brain lesions can affect peripheral axonal excitability even during the early stage. The NET pattern probably suggests background membrane depolarization of LMNs. These features could be associated with trans-synaptic regulation of UMNs to LMNs as one of the "neural plasticity" mechanisms in acute brain injury.

Bonding values of two contemporary ceramic inlay materials to dentin following simulated aging

  • Khalil, Ashraf Abdelfattah;Abdelaziz, Khalid Mohamed
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.6
    • /
    • pp.446-453
    • /
    • 2015
  • PURPOSE. To compare the push-out bond strength of feldspar and zirconia-based ceramic inlays bonded to dentin with different resin cements following simulated aging. MATERIALS AND METHODS. Occlusal cavities in 80 extracted molars were restored in 2 groups (n=40) with CAD/CAM feldspar (Vitablocs Trilux forte) (FP) and zirconia-based (Ceramill Zi) (ZR) ceramic inlays. The fabricated inlays were luted in 2 subgroups (n=20) with either etch-and-bond (RelyX Ultimate Clicker) (EB) or self-adhesive (RelyX Unicem Aplicap) (SA) resin cement. Ten inlays in each subgroup were subjected to 3,500 thermal cycles and 24,000 loading cycles, while the other 10 served as control. Horizontal 3 mm thick specimens were cut out of the restored teeth for push out bond strength testing. Bond strength data were statistically analyzed using 1-way ANOVA and Tukey's comparisons at ${\alpha}=.05$. The mode of ceramic-cement-dentin bond failure for each specimen was also assessed. RESULTS. No statistically significant differences were noticed between FP and ZR bond strength to dentin in all subgroups (ANOVA, P=.05113). No differences were noticed between EB and SA (Tukey's, P>.05) bonded to either type of ceramics. Both adhesive and mixed modes of bond failure were dominant for non-aged inlays. Simulated aging had no significant effect on bond strength values (Tukey's, P>.05) of all ceramic-cement combinations although the adhesive mode of bond failure became more common (60-80%) in aged inlays. CONCLUSION. The suggested cement-ceramic combinations offer comparable bonding performance to dentin substrate either before or after simulated aging that seems to have no adverse effect on the achieved bond.