• Title/Summary/Keyword: non-testing methods

Search Result 489, Processing Time 0.023 seconds

Mechanical Stability of TiN and DLC Coated Instrument of Pedicle Screw System (TiN 및 DLC 코팅된 척추경나사못시스템 수술기구의 기계적 안정성 분석)

  • Kang, Kwan-Su;Jung, Tae-Gon;Yang, Jae-Woong;Woo, Su-Heon;Park, Tea-Hyun;Jeong, Yong-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.3
    • /
    • pp.163-170
    • /
    • 2019
  • Durability of instrument is one of the most important factor to ensure accurate treatment and decrease failure for the orthopedic surgical operation. Normally, a set-screw driver tip has been processed with hard coating for their higher durability and wear resistance. And several surface modification methods were obtained such as titanium nitride (TiN) coating, diamond like carbon coating, other nitriding, and etc. In this study, we have surface modified on set-screw driver tip with TiN and DLC, investigated whether the TiN and DLC coatings affect the mechanical properties and durability of the set-screw driver tip in the pedicle screw system. The surface morphologies were observed with scanning-electron microscopy (SEM), and the static/dynamic torsional properties were investigated with universal testing machine based on ASTM F543. Coating thickness of each coatings were commonly around $1^{\circ}C$. Static torsional stiffness, and ultimate torque values for DLC and TiN coated samples were significantly higher than those of non-coated sample by the pared T-test. Surface morphology of after the dynamic torsional test was more clean with less scratch or friction traces from DLC coating than that of TiN coating and non-coated sample.

The Influence of Non-Linear Frequency Compression on the Perception of Speech and Music in Patients with High Frequency Hearing Loss

  • Ahn, Jungmin;Choi, Ji Eun;Kang, Ju Yong;Choi, Ik Joon;Lee, Myung-Chul;Lee, Byeong-Cheol;Hong, Sung Hwa;Moon, Il Joon
    • Korean Journal of Audiology
    • /
    • v.25 no.2
    • /
    • pp.80-88
    • /
    • 2021
  • Background and Objectives: Non-linear frequency compression (NLFC) technology compresses and shifts higher frequencies into a lower frequency area that has better residual hearing. Because consonants are uttered in the high-frequency area, NLFC could provide better speech understanding. The aim of this study was to investigate the clinical effectiveness of NLFC technology on the perception of speech and music in patients with high-frequency hearing loss. Subjects and Methods: Twelve participants with high-frequency hearing loss were tested in a counter-balanced order, and had two weeks of daily experience with NLFC set on/off prior to testing. Performance was repeatedly evaluated with consonant tests in quiet and noise environments, speech perception in noise, music perception and acceptableness of sound quality rating tasks. Additionally, two questionnaires (the Abbreviated Profile of Hearing Aid Benefit and the Korean version of the International Outcome Inventory-Hearing Aids) were administered. Results: Consonant and speech perception improved with hearing aids (NLFC on/off conditions), but there was no significant difference between NLFC on and off states. Music perception performances revealed no notable difference among unaided and NLFC on and off states. The benefits and satisfaction ratings between NLFC on and off conditions were also not significantly different, based on questionnaires, however great individual variability preferences were noted. Conclusions: Speech perception as well as music perception both in quiet and noise environments was similar between NLFC on and off states, indicating that real world benefits from NLFC technology may be limited in Korean adult hearing aid users.

The Influence of Non-Linear Frequency Compression on the Perception of Speech and Music in Patients with High Frequency Hearing Loss

  • Ahn, Jungmin;Choi, Ji Eun;Kang, Ju Yong;Choi, Ik Joon;Lee, Myung-Chul;Lee, Byeong-Cheol;Hong, Sung Hwa;Moon, Il Joon
    • Journal of Audiology & Otology
    • /
    • v.25 no.2
    • /
    • pp.80-88
    • /
    • 2021
  • Background and Objectives: Non-linear frequency compression (NLFC) technology compresses and shifts higher frequencies into a lower frequency area that has better residual hearing. Because consonants are uttered in the high-frequency area, NLFC could provide better speech understanding. The aim of this study was to investigate the clinical effectiveness of NLFC technology on the perception of speech and music in patients with high-frequency hearing loss. Subjects and Methods: Twelve participants with high-frequency hearing loss were tested in a counter-balanced order, and had two weeks of daily experience with NLFC set on/off prior to testing. Performance was repeatedly evaluated with consonant tests in quiet and noise environments, speech perception in noise, music perception and acceptableness of sound quality rating tasks. Additionally, two questionnaires (the Abbreviated Profile of Hearing Aid Benefit and the Korean version of the International Outcome Inventory-Hearing Aids) were administered. Results: Consonant and speech perception improved with hearing aids (NLFC on/off conditions), but there was no significant difference between NLFC on and off states. Music perception performances revealed no notable difference among unaided and NLFC on and off states. The benefits and satisfaction ratings between NLFC on and off conditions were also not significantly different, based on questionnaires, however great individual variability preferences were noted. Conclusions: Speech perception as well as music perception both in quiet and noise environments was similar between NLFC on and off states, indicating that real world benefits from NLFC technology may be limited in Korean adult hearing aid users.

Estimation of liquid limit of cohesive soil using video-based vibration measurement

  • Matthew Sands;Evan Hayes;Soonkie Nam;Jinki Kim
    • Geomechanics and Engineering
    • /
    • v.33 no.2
    • /
    • pp.175-182
    • /
    • 2023
  • In general, the design of structures and its construction processes are fundamentally dependent on their foundation and supporting ground. Thus, it is imperative to understand the behavior of the soil under certain stress and drainage conditions. As it is well known that certain characteristics and behaviors of soils with fines are highly dependent on water content, it is critical to accurately measure and identify the status of the soils in terms of water contents. Liquid limit is one of the important soil index properties to define such characteristics. However, liquid limit measurement can be affected by the proficiency of the operator. On the other hand, dynamic properties of soils are also necessary in many different applications and current testing methods often require special equipment in the laboratory, which is often expensive and sensitive to test conditions. In order to address these concerns and advance the state of the art, this study explores a novel method to determine the liquid limit of cohesive soil by employing video-based vibration analysis. In this research, the modal characteristics of cohesive soil columns are extracted from videos by utilizing phase-based motion estimation. By utilizing the proposed method that analyzes the optical flow in every pixel of the series of frames that effectively represents the motion of corresponding points of the soil specimen, the vibration characteristics of the entire soil specimen could be assessed in a non-contact and non-destructive manner. The experimental investigation results compared with the liquid limit determined by the standard method verify that the proposed method reliably and straightforwardly identifies the liquid limit of clay. It is envisioned that the proposed approach could be applied to measuring liquid limit of soil in practical field, entertaining its simple implementation that only requires a digital camera or even a smartphone without the need for special equipment that may be subject to the proficiency of the operator.

A Study on the Viscoelastic Model of Asphalt Concrete Pavement (아스팔트 포장의 점탄성 거동 모델에 관한 연구)

  • Jo, Byung Wan;Tae, Ghi Ho;Noh, Dong Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3A
    • /
    • pp.429-437
    • /
    • 2006
  • Existing basic mechanical models which are methods characterizing viscoelastic materials were first reviewed to account for viscoelastic behavior of the asphalt pavement structure in this paper. A viscoelastic mechanical model considering a single load of vehicles subsequently was suggested and an equation that indicates the time-dependant behavior of asphalt pavements was derived from the proposed model. Non-destructive tests using falling weight deflectometer(FWD) were performed for a test section to estimate the application of the model. Both deflections and strains procured by the equation were compared to testing results according to loading history. By observing field measurements and theoretical evaluations, if two results are compared by the features of deflection according to time history, it could be concluded that the proposed model is expected to be suitable for prediction of the behavior of asphalt pavements because there is hardly difference between field data and calculated data.

Review of Environmental Characteristics and Building Finishes Controlling the Spread of SARS-CoV-2 - Focused on overseas literature related to antiviral experiments (코로나 바이러스 확산억제를 위한 환경 및 건축마감재료 고찰 - 항바이러스 재료 관련 해외 문헌을 중심으로)

  • Park, Yonghyun;Lee, Hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.4
    • /
    • pp.37-44
    • /
    • 2023
  • Purpose: Currently, research on environmental conditions and finishing materials for medical facilities with proven antiviral performance is poor in Korea. Through this study, we have explored environmental characteristics and finishing materials that can be used to control cross-infection when constructing medical facilities. Methods: Experiments in overseas papers related to antiviral effects of environmental conditions, spatial compartments, and interior finishes have been analyzed. Results: The higher the temperature, the higher the humidity, and the higher the illuminance of sunlight, the lower the viability of the corona-virus. The proliferation of viruses was suppressed on the surface of the copper alloy. Materials such as brushed steel are the ones that maintain the strongest viability. Among the characteristics of the surface, survival and propagation power differ depending on whether it is porous or hydrophilic. In the case of infection ward actually operated in Italy, the presence of airborne viruses in contaminated and non-contaminated spaces differed significantly. Corona-virus has been identified in reachable parts such as door handles and medical shelves in quasi-contaminated spaces, which are spaces between contaminated and non-contaminated spaces, but the corona-virus has not been identified in cases of out-of-touch walls. Implications: It is necessary to evaluate the performance by testing the construction finishing materials of infection control facilities according to domestic conditions.

Questionnaire Survey on Perception and Attitude Toward of Remote Treatment by Korean Medicine Doctors (한의사의 비대면 진료에 대한 인식과 수용도 설문조사연구)

  • Juchul Kim;Sohyun Kim;Hyunjoo Oh;Eunji Ahn;Dongsu Kim
    • The Journal of Korean Medicine
    • /
    • v.45 no.1
    • /
    • pp.100-113
    • /
    • 2024
  • Objectives: Following the global COVID-19 pandemic, with the escalation of remote medical care formalization in Korea, there is a pressing need for objective data in the Korean medicine field to respond to remote treatment medical care policies. This study aims to investigate the perceptions and acceptance of remote treatments among Korean Medicine Doctors (KMDs). Methods: After expert reviews and pilot testing, the 31-question survey covered participant characteristics, experiences, forms, intentions, and perceptions related to Remote Treatments. The survey was electronically distributed to members of the Association of Korean Medicine, and 662 clinical KMDs provided valid responses. Results: Among respondents, 76.1% engaged in remote treatments, utilizing various platforms. Those with experience in Remote Treatments showed a significantly higher willingness to continue participating during the institutionalization process (p<0.001). 49.7% of respondents stated that traditional Korean medicine is competitive in remote treatments, with the main reasons being the ability for regular management after herbal medication(26.1%) and increased patient satisfaction due to sufficient counseling compared to Western medicine(25.2%). Respondents preferred Remote Treatment conditions with a treatment time of less than 10 minutes(47.6%) and equivalent fees to in-person visits(45.6%). Regarding suitable intervention tools during Remote Treatment, respondents favored non-covered herbal prescriptions(39.0%), covered herbal granules(24.6%), and non-covered herbal granules(23.0%). Conclusion: This study investigated the perceptions and acceptance of KMDs regarding remote treatments. These findings provide valuable insights for policymakers aiming to establish effective policies for Remote Treatments suitable for the Korean medicine healthcare environment.

Evaluation of the influence of a visual design of an examination guide on patient comprehension and testing accuracy (검사 안내문의 시각적 디자인화가 환자의 검사 이해도 및 정확성에 미치는 영향 평가)

  • Kang, Young-Eun;Jung, Woo-Young;Hong, Bo-Ruem
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.29-34
    • /
    • 2019
  • Purpose An examination guide is a useful medium to provide the patient with an overview, pre- and post-test preparation, and precautions of nuclear testing. The design and arrangement of existing written texts and announcements were evaluated to elucidate the comprehension of patients undergoing testing. Materials and Methods Informational material describing bone scanning and $^{201}thallium$ myocardium perfusion single-photon emission computed tomography (SPECT), as a secondary examination, which accounts for the largest portion of gamma imaging at Asan Hospital (Seoul, South Korea), was selected as an improvement target in consultation with a national innovation center. Existing informational material was dispensed to patients scheduled for bone scans from November 2016 to February 2017 and the revised material was issued from March 2017 to May 2017. A survey was conducted of 200 patients who underwent $^{201}thallium$ myocardium perfusion SPECT before and after the revisions (n = 100 each time period) to assess the patients' understanding of the informational material. Results When comparing the use of the conventional vs. revised material, the number of patients who received treatment before bone scanning had decreased from 130 to 60, while the number of those who required additional imaging decreased from 53 to 14. Prior to the revision, 43% of patients underwent testing before preparation and 18% underwent additional testing. The decreased need for additional image acquisition after revision of the informational material resulted in a decrease in acquisition time of about 2 min, from 16.5 to 14.2 min. In the case of $^{201}thallium$ myocardium perfusion SPECT, patient comprehension of all five items surveyed had increased, while the number of patients who had repeatedly asked about various facets of the procedure pre- and post-testing had decreased from 36% to 16% and 31% to 14%, respectively. Conclusion Lower patient comprehension is accompanied by a decrease in image quality due to non-compliance during pre-testing and may lead to repetitive questions from the patient, which may also negatively affect the fatigue and work efficiency of the examiner. Improved readability and visibility of informational material through visualization was correlated with greater patient comprehension as well as improved image quality and acquisition time.

Reduction of Radiographic Quantum Noise Using Adaptive Weighted Median Filter (적응성 가중메디안 필터를 이용한 방사선 투과영상의 양자 잡음 제거)

  • Lee, Hoo-Min;Nam, Moon-Hyon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.465-473
    • /
    • 2002
  • Images are easily corrupted by noise during the data transmission, data capture and data processing. A technical method of noise analyzing and adaptive filtering for reducing of quantum noise in radiography is presented. By adjusting the characteristics of the filter according to local statistics around each pixel of the image as moving windowing, it is possible to suppress noise sufficiently while preserve edge and other significant information required in reading. We have proposed adaptive weighted median(AWM) filters based on local statistics. We show two ways of realizing the AWM filters. One is a simple type of AWM filter, whose weights are given by a simple non-linear function of three local characteristics. The other is the AWM filter which is constructed by homogeneous factor(HF). Homogeneous factor(HF) from the quantum noise models that enables the filter to recognize the local structures of the image is introduced, and an algorithm for determining the HF fitted to the detection systems with various inner statistical properties is proposed. We show by the experimented that the performances of proposed method is superior to these of other filters and models in preserving small details and suppressing the noise at homogeneous region. The proposed algorithms were implemented by visual C++ language on a IBM-PC Pentium 550 for testing purposes, the effects and results of the noise filtering were proposed by comparing with images of the other existing filtering methods.

Comparison of Instrument Characteristics on the Total Organic Carbon Analysis Method in Water Samples (수질분야 총유기탄소 분석방법에 따른 장비별 특성 비교)

  • Hye-Sung Kim;Eun-Tae Hwang;Chan-Geun Lee;Young-Cheol Cho
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.5
    • /
    • pp.353-362
    • /
    • 2023
  • TOC, which can measure more than 90% of organic substances, can be measured quickly and easily,replacing BOD and COD, which were indicators of organic pollutants. According to water quality pollution control standards, when measuring TOC, if the inorganic carbon ratio in the sample is over 50%, the NPOC (Non-Purgeable Organic Carbon) method should be used. If volatile organic compounds (VOCs) are present at a certain concentration, the TC-IC (subtracting inorganic carbon from total carbon) method should be used. To validate the limitations of these analytical conditions, experiments were conducted by varying the ratio of TOC to IC in purified water and measuring the concentration of TOC in test solutions. The results showed no significant difference between the TC-IC method and the NPOC method. When measuring samples with added VOC standard solutions, it was observed that the carbon loss due to purging was not significant when using the NPOC method. Therefore, it is concluded that the choice of analytical method does not lead to significant differences when VOCs are present in the sample. To account for potential variations in results based on water quality pollution control standards and regulations regarding the approval and testing of environmental measurement devices, a comparison of field sample concentration values was made using two widely used types of TOC analyzers in Korea. The results showed variations of 0.02 to 0.83 mg/L between methods depending on the manufacturer, highlighting the need for caution when selecting an instrument.