• Title/Summary/Keyword: non-structural

Search Result 3,803, Processing Time 0.029 seconds

Ozone Impacts on Soluble Carbohydrates, Antioxidant Activity and Macro-element Concentrations in Rice Seedling

  • Sung Jwa-Kyung;Park So-Hyeon;Lee Su-Yeon;Lee Ju-Young;Jang Byoung-Choon;Hwang Seon-Woong;Kim Tae-Wan;Song Beom-Heon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.51 no.2
    • /
    • pp.142-147
    • /
    • 2006
  • The present study describes carbohydrate metabolism, macro-element utilization and antioxidant defenses in response to an ozone dose (100 ppb, 8d) in two rice varieties. Tolerant (cv. Jinpumbyeo) and sensitive (cv. Chucheongbyeo) varieties of rice were grown in growth chamber for 30 days after sowing. Concentrations of chloroplast pigments and non-structural carbohydrates as well as activity of antioxidant enzymes were determined to evaluate the resistance against ozone stress. Ozone caused the decrease in chlorophyll a and carotenoid contents, and also resulted in faster decomposition of non-structural carbohydrate in leaf blade and leaf sheath. The contents of nitrogen and potassium in leaves were visibly decreased in cv. Chucheongbyeo with an increase in ozone exposure, but not in cv. Jinpumbyeo. Enzymatic antioxidants against ROS in both varieties responded in the order of POD, SOD and CAT, and their capacity was stronger in cv. Jinpumbyeo.

A unified solution for vibration analysis of plates with general structural stress distributions

  • Yang, Nian;Chen, Lu-Yun;Yi, Hong;Liu, Yong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.6
    • /
    • pp.615-630
    • /
    • 2016
  • Complex stress distributions often exist in ocean engineering structures. This stress influences structural vibrations. Finite Element Methods exhibit some shortcomings for solving non-uniform stress problems, such as an unclear physical interpretation, complicated operation, and large number of computations. Analytical methods research considers mainly uniform stress problems, and often, their methods cannot be applied in practical marine structures with non-uniform stress. In this paper, an analytical method is proposed to solve the vibration of plates with general stress distributions. Non-uniform stress is expressed as a special series, and the stress influence is inserted into a vibration equation that is solved through decoupling to obtain an analytical solution. This method has been verified using numerical examples and can be used in arbitrary stress distribution cases. This method requires fewer computations and it provides a clearer physical interpretation, so it has advantages in some qualitative research.

A Method for Checking Missed Eigenvalues in Eigenvalue Analysis with Damping Matrix

  • Jung, Hyung-Jo;Kim, Dong-Hyawn;Lee, In-Won
    • Computational Structural Engineering : An International Journal
    • /
    • v.1 no.1
    • /
    • pp.31-38
    • /
    • 2001
  • In the case of the non-proportionally damped system such as the soil-structure interaction system, the structural control system and composite structures, the eigenproblem with the damping matrix should be necessarily performed to obtain the exact dynamic response. However, most of the eigenvalue analysis methods such as the subspace iteration method and the Lanczos method may miss some eigenvalues in the required ones. Therefore, the eigenvalue analysis method must include a technique to check the missed eigenvalues to become the practical tools. In the case of the undamped or proportionally damped system the missed eigenvalues can easily be checked by using the well-known Sturm sequence property, while in the case of the non-proportionally damped system a checking technique has not been developed yet. In this paper, a technique of checking the missed eigenvalues for the eigenproblem with the damping matrix is proposed by applying the argument principle. To verify the effectiveness of the proposed method, two numerical examples are considered.

  • PDF

A total strain-based hysteretic material model for reinforced concrete structures: theory and verifications

  • Yun, Gun-Jin;Harmon, Thomas G.;Dyke, Shirley J.;So, Migeum
    • Computers and Concrete
    • /
    • v.5 no.3
    • /
    • pp.217-241
    • /
    • 2008
  • In this paper, a total strain-based hysteretic material model based on MCFT is proposed for non-linear finite element analysis of reinforced concrete structures. Although many concrete models have been proposed for simulating behavior of structures under cyclic loading conditions, accurate simulations remain challenging due to uncertainties in materials, pitfalls of crude assumptions of existing models, and limited understanding of failure mechanisms. The proposed model is equipped with a fully generalized hysteresis rule and is formulated for 2D plane stress non-linear finite element analysis. The proposed model has been formulated in a tangent stiffness-based finite element scheme so that it can be used for most general finite element analysis packages. Moreover, it eliminates the need to check that tensile stresses can be transmitted across a crack. The tension stiffening model is a function of the bar orientation and any orientation can be accommodated. The proposed model has been verified with a series of experimental results of 2D RC planar panels. This study also demonstrates how parameters of the proposed model associated with cyclic damage modeling influences the pinched cyclic shear behavior.

Structural and Functional Stability of the Genetic Recombinant Plasmid pCU103 in Different Water Environments

  • Kim, Chi-Kyung;Kwak, Myoung-Ja;Lee, Sung-Gie
    • Journal of Microbiology
    • /
    • v.34 no.3
    • /
    • pp.241-247
    • /
    • 1996
  • The stability of the genetically engineered microorganisms and their recombinant plasmids released in natural environments has been regarded as one of the molecular ecological topics. In this study, the recombinant plasmids pCU103 in which the pcbCD genes involved in biodegradation of biphenyl and 4-chlorobiphenyl were cloned in pBluescript SK(+) vector, were examined for their structural and functional stability in different waters at 15 $^{\circ}C$ by the methods of electrophoresis, Southern hybridization, quantification with fluorescent dye, and transformation. The recombinant plamids maintained their stabilities for about 30 days in sterilized distilled water (SDW), 15 days in autoclaved creek water (AW), 25 days in filtered and autoclaved non-sterile creek water (FAW), 4 days in Luria-Bertani (LB) broth, and less than one day in filtered non-sterile creek water (FW). The covalently closed circular (CCC) form of the plasmid was decreased and open circular (OC) form was increased as a function of incubation time, and then linear (L) form was produced to be ultimately degraded out. The degradation rates of the plasmid were proportionally correlated to trophic level of the water, and the biological factor such as DNases was found to be one of the most critical factors affecting structural and functional stability of the plasmid in non-sterile natural water.

  • PDF

Comparison of immunogenecities of three beta-nodavirus proteins, capsid protein, non-structural protein B1 and B2 in olive flounder

  • Cha, Seung-Ju;Do, Jeong-Wan;Ko, Myoung-Seok;Kim, Jin-Woo;Park, Jeong-Woo
    • Journal of fish pathology
    • /
    • v.22 no.3
    • /
    • pp.219-228
    • /
    • 2009
  • The genomic and subgenomic RNAs of fish nodavirus encode the four proteins, protein A, capsid protein, non-structural protein B1 and B2. In this study, we describe the immune response of olive flounder Paralichthys olivaceus immunized with live fish nodavirus or recombinant capsid protein, non-structural protein B1 and B2 expressed in E. coli. Nodavirus-infected flounder produced antibodies to capsid protein, B1 and B2 and nodavirus-neutralizing activities were detected in the serum of the nodavirus-infected flounder. The flounder were immunized against the three recombinant proteins of fish nodavirus and the sera from these immunized fishes were assayed for nodavirus-specific antibody by ELISA and a neutralization test. In the immunized flounder, all three recombinant proteins induced the production of similar levels of antibody, but only the antibody to capsid protein significantly neutralized nodavirus. These results indicate that all three nodaviral proteins are immunogenic in flounder, but only the capsid protein can induce neutralizing antibody against nodavirus.

Evaluation of Structural Performance of Joints Between Modules With Non-Symmetric Section (비대칭 단면으로 구성된 모듈 간 접합부의 구조 성능 평가)

  • Park, Keum-Sung;Lee, Sang-Sup;Moon, Ji-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.2
    • /
    • pp.35-42
    • /
    • 2019
  • The purpose of this paper is to evaluate the structural performance of joints between modules with steel plate press forming type non-symmetric cross section. The main experimental variables are direction of load, whether vertical bolts are fastened, and whether the concrete inside the column is filled. A total of three experiments were performed for each variable. Experimental results show that the behavior of the joints dominated by the local buckling deformation of the upper and lower beam flanges of the module joints, and the final failure was the fracture of the column-beam welds. In case of short side direction, it is possible to secure the performance of intermediate moment frame (0.02 rad). In case of long side direction, it is evaluated that the performance of special moment frame (0.04 rad) is secured regardless of whether or not concrete is infilled in the column.

Investigation of Dynamic Characteristcs Uninterruptible Power Supply System (UPS) Using Shaking Table Tests (무정전전원장치(UPS)의 진동대 실험 및 동적특성 분석)

  • Lee, Seung-Jae;Kim, Joo-Young;Choi, Kyoung-Kyu
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.11
    • /
    • pp.129-136
    • /
    • 2019
  • Non-structural elements are vulnerable to earthquake ground motion. In this study, an experimental study for the electrical non-structural element was performed using tri-axial shaking table tests. A 100kVA UPS(Uninterruptible Power Supply system) was used as the test specimen. The test specimen was anchored to the concrete slab using the conventional installation detail. The input acceleration were generated in accordance with ICC-ES AC156 code. Scale factors of the input acceleration with respect to the required response spectrum defined in ICC-ES AC156 were from 25% to 600%. Based on the test results, damage and dynamic characteristics of UPS were evaluated and analyzed including natural frequency, damping ratio, acceleration time history response, dynamic amplification factor and relative displacement.

An equivalent linear SDOF system for prediction of nonlinear displacement demands of non-ductile reinforced concrete buildings with shear walls

  • Saman Yaghmaei-Sabegh;Shabnam Neekmanesh;Nelson Lam;Anita Amirsardari;Nasser Taghizadieh
    • Structural Engineering and Mechanics
    • /
    • v.85 no.5
    • /
    • pp.655-664
    • /
    • 2023
  • Reinforced concrete (RC) shear wall structures are one of the most widely used structural systems to resist seismic loading all around the world. Although there have been several efforts to provide conceptually simple procedures to reasonably assess the seismic demands of structures over recent decades, it seems that lesser effort has been put on a number of structural forms such as RC shear wall structures. Therefore, this study aims to represent a simple linear response spectrum-based method which can acceptably predict the nonlinear displacements of a non-ductile RC shear wall structure subjected to an individual ground motion record. An effective period and an equivalent damping ratio are introduced as the dynamic characteristics of an equivalent linear SDOF system relevant to the main structure. By applying the fundamental mode participation factor of the original MDOF structure to the linear spectral response of the equivalent SDOF system, an acceptable estimation of the nonlinear displacement response is obtained. Subsequently, the accuracy of the proposed method is evaluated by comparison with another approximate method which is based on linear response spectrum. Results show that the proposed method has better estimations for maximum nonlinear responses and is more utilizable and applicable than the other one.

Causes of local collapse of a precast industrial roof after a fire

  • Bruno Dal Lago;Paride Tucci
    • Computers and Concrete
    • /
    • v.31 no.5
    • /
    • pp.371-384
    • /
    • 2023
  • Precast roofing systems employing prestressed elements often serve as smart structural solutions for the construction of industrial buildings. The precast concrete elements usually employed are highly engineered, and often consist in thin-walled members, characterised by a complex behaviour in fire. The present study was carried out after a fire event damaged a precast industrial building made with prestressed beam and roof elements, and non-prestressed curved barrel vault elements interposed in between the spaced roof elements. As a consequence of the exposure to the fire, the main elements were found standing, although some locally damaged and distorted, and the local collapse of few curved barrel vault elements was observed in one edge row only. In order to understand and interpret the observed structural performance of the roof system under fire, a full fire safety engineering process was carried out according to the following steps: (a) realistic temperature-time curves acting on the structural elements were simulated through computational fluid dynamics, (b) temperature distribution within the concrete elements was obtained with non-linear thermal analysis in variable regime, (c) strength and deformation of the concrete elements were checked with non-linear thermal-mechanical analysis. The analysis of the results allowed to identify the causes of the local collapses occurred, attributable to the distortion caused by temperature to the elements causing loss of support in early fire stage rather than to the material strength reduction due to the progressive exposure of the elements to fire. Finally, practical hints are provided to avoid such a phenomenon to occur when designing similar structures.