Condensation oscillation characteristic of steam with non-condensable gas through multi-hole sparger at low mass flux

  • Dandi Zhang;Lili Tong;Xuewu Cao
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.780-791
    • /
    • 2023
  • To study oscillation characteristic of steam and non-condensable gas direct contact condensation through multi-hole sparger at low mass flux, a series of experiments of pure steam and mixture gas condensation have been carried out under the conditions of steam mass flux of 20-120kg/m2s, water temperature of 20-95 ℃ and mass fraction of non-condensable gas of 0-5%. The regime map of pure steam condensation through multi-hole sparger is divided into steam chugging, separated bubble, aggregated bubble and escaping aggregated bubble. The bubbles behavior of synchronization in the same hole columns and desynchronized excitation between different hole columns can be found. The coalescence effect of mixture bubbles increases with water temperature and non-condensable gas content increasing. Pressure oscillation intensity of pure steam condensation first increases and then decreases with water temperature increasing, and increases with steam mass flux increasing. Pressure oscillation intensity of mixture gas condensation decreases with water temperature and non-condensable gas content increasing, which is significantly weaker than that of pure steam condensation. The oscillation dominant frequency decreases with the rise of water temperature and non-condensable gas content. The correlations for oscillation intensity and dominant frequency respectively are developed in pure steam and mixture gas condensation at low mass flux.

비평형 습증기 모델을 적용한 증기 응축 유동 해석 (ANALYSIS ON STEAM CONDENSING FLOW USING NON-EQUILIBRIUM WET-STEAM MODEL)

  • 김창현;박재현;고동건;김동일;김영상;백제현
    • 한국전산유체공학회지
    • /
    • 제20권3호
    • /
    • pp.1-7
    • /
    • 2015
  • When the steam is used as working fluid in fluid machinery, different from other gases as air, phase transition (steam condensation) can occur and it affects not only the flow fields, but also machine performance & efficiency. Therefore, considering phase transition phenomena in CFD calculation is required to achieve accurate prediction of steam flow and non-equilibrium wet-steam model is needed to simulate realistic steam condensing flow. In this research, non-equilibrium wet-steam model is implemented on in-house code(T-Flow), the flow fields including phase transition phenomena in convergent-divergent nozzle are studied and compared to results of advance researches.

비열 및 열처리에 따른 보리의 알코올발효 특성 (Properties of Alcohol Fermentation from Barley Treated with Non-steam and Steam)

  • 우승미;김태영;여수환;김상범;정용진
    • 한국식품저장유통학회지
    • /
    • 제14권2호
    • /
    • pp.201-206
    • /
    • 2007
  • 본 연구에서는 비열 및 열처리에 따른 5종류의 보리 품종별 알코올발효 특성을 조사하였다. 비열처리구에서 알코올 함량은 쌀보리, 찰쌀보리 및 흰찰쌀보리가 각각 1.7, 2.9 및 4.3%로 나타났으며 보리와 찰보리는 발효가 되지 않았다. 열처리구에서 비열처리구에 비해 전반적으로 골은 알코올생성능을 보였다. 당도는 비열처리구의 보리 및 찰보리가 $9.0\;^{\circ}Brix$ 전후의 높은 당도를 나타내었고 쌀보리, 찰쌀보리, 흰찰쌀보리가 $5.0\;^{\circ}Brix$ 전후의 당도로 나타났다. 열처리구의 당도는 알코올생성능과 반비례 경향이었으며 알코올발효 종료 후 쌀보리를 제외하고는 당함량이 50%이상 감소되었다. 비열처리구에서 산도는 흰찰쌀보리가 0.51%로 나타났으며 나머지 시료들은0.80%이상의 수치를 보여 산패의 가능성을 보였고, 열처리구에서는 모든 시료들이 0.3%이하의 수치로 나타났다. 유리당은 비열처리구의 보리와 찰보리가 알코올을 생성하지 않았으므로 유리당 총함량은 4,000.0 mg%전후로 높게 나타났고 쌀보리, 찰쌀보리 및 흰찰쌀보리는 300.0mg%전후의 함량으로 나타났다. 열처리구에서는 당도가 높을수록 유리당 총 함량이 높게 나타났으며 이상의 결과 보리는 열처리에 비해 비열처리 알코올 발효에는 적합하지 않았다.

Investigation of condensation with non-condensable gas in natural circulation loop for passive safety system

  • Jin-Hwa Yang;Tae-Hwan Ahn;Hwang Bae;Hyun-Sik Park
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.1125-1139
    • /
    • 2023
  • The system-integrated modular advanced reactor 100 (SMART100), an integral-type pressurized water small modular reactor, is based on a novel design concept for containment cooling and radioactive material reduction; it is known as the containment pressure and radioactivity suppression system (CPRSS). There is a passive cooling system using a condensation with non-condensable gas in the SMART CPRSS. When a design basis accident such as a small break loss of coolant accident (SBLOCA) occurs, the pressurized low containment area (LCA) of the SMART CPRSS leads to steam condensation in an incontainment refuelling water storage tank (IRWST). Additionally, the steam and non-condensable gas mixture passes through the CPRSS heat exchanger (CHX) submerged in the emergency cooldown tank (ECT) that can partially remove the residual heat. When the steam and non-condensable gas mixture passes through the CHX, the non-condensable gas can interrupt the condensation heat transfer in the CHX and it degrades CHX performance. In this study, condensation heat transfer experiments of steam and non-condensable gas mixture in the natural circulation loop were conducted. The pressure, temperature, and effects of the non-condensable gas were investigated according to the constant inlet steam flow rate with non-condensable gas injections in the loop.

다변량 로지스틱 회귀분석을 이용한 증기발생기 전열관 ODSCC의 POD곡면 분석 (Evaluation of the Probability of Detection Surface for ODSCC in Steam Generator Tubes Using Multivariate Logistic Regression)

  • 이재봉;박재학;김홍덕;정한섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.250-255
    • /
    • 2007
  • Steam generator tubes play an important role in safety because they constitute one of the primary barriers between the radioactive and non-radioactive sides of the nuclear power plant. For this reason, the integrity of the tubes is essential in minimizing the leakage possibility of radioactive water. The integrity of the tubes is evaluated based on NDE (non-destructive evaluation) inspection results. Especially ECT (eddy current test) method is usually used for detecting the flaws in steam generator tubes. However, detection capacity of the NDE is not perfect and all of the "real flaws" which actually existing in steam generator tunes is not known by NDE results. Therefore reliability of NDE system is one of the essential parts in assessing the integrity of steam generators. In this study POD (probability of detection) of ECT system for ODSCC in steam generator tubes is evaluated using multivariate logistic regression. The cracked tube specimens are made using the withdrawn steam generator tubes. Therefore the cracks are not artificial but real. Using the multivariate logistic regression method, continuous POD surfaces are evaluated from hit (detection) and miss (no detection) binary data obtained from destructive and non-destructive evaluation of the cracked tubes. Length and depth of cracks are considered in multivariate logistic regression and their effects on detection capacity are evaluated.

  • PDF

두 개의 비대칭 축방향 관통균열이 존재하는 증기발생기 세관의 소성붕괴압력 평가 (Evaluation of Plastic Collapse Pressure for Steam Generator Tube with Non-Aligned Two Axial Through-Wall Cracks)

  • 문성인;장윤석;이진호;송명호;최영환;김영진
    • 대한기계학회논문집A
    • /
    • 제29권8호
    • /
    • pp.1070-1077
    • /
    • 2005
  • The $40\%$ of wall thickness criterion which has been used as a plugging rule is applicable only to a single cracked steam generator tubes. In the previous studies performed by authors, several failure prediction models were introduced to estimate the plastic collapse pressures of steam generator tubes containing collinear or parallel two adjacent axial through-wall cracks. The objective of this study is to examine the failure prediction models and propose optimum ones for non-aligned two axial through-wall cracks in steam generator tubes. In order to determine the optimum ones, a series of plastic collapse tests and finite element analyses were carried out for steam generator tubes with two machined non-aligned axial through-wall cracks. Thereby, either the plastic zone contact model or COD based model was selected as the optimum one according to axial distance between two clacks. Finally, the optimum failure prediction model was used to demonstrate the conservatism of flaw characterization rules for various multiple flaws according to ASME code.

The Effect of Non-condensable Gas on Direct Contact Condensation of Steam/Air Mixture

  • Lee, Hanchoon;Kim, Moohwan;Park, Suki
    • Nuclear Engineering and Technology
    • /
    • 제33권6호
    • /
    • pp.585-595
    • /
    • 2001
  • A series of experiments have been carried out to investigate the effects of non-condensable gas on the direct contact film condensation of vapor mixture under an adiabatic wall condition. The average heat transfer coefficient of the direct contact condensation was obtained at the atmospheric pressure with four main parameters ; air-mass fraction, mixture velocity, film Reynolds number, and the degree of water film subcooling having an influence on the condensation heat transfer coefficient. With the analysis of 88 experiments, a correlation of the average Nusselt number for direct contact film condensation of steam/air mixture at an adiabatic vertical wall was proposed as functions of film Reynolds number, mixture Reynolds number, air mass fraction, and Jacob number. The average heat transfer coefficient for steam/air mixture condensation decreased significantly while air mass fraction increased. The average heat transfer coefficients also decreased as the Jacob number increased, and were scarcely affected by the film Reynolds number below a mixture Reynolds number of about 245,000.

  • PDF

Implementation Status of Performance Demonstration Program for Steam Generator Tubing Analysts in Korea

  • Cho, Chan-Hee;Lee, Hee-Jong;Yoo, Hyun-Ju;Nam, Min-Woo;Hong, Sung-Yull
    • 비파괴검사학회지
    • /
    • 제33권1호
    • /
    • pp.63-68
    • /
    • 2013
  • Some essential components in nuclear power plants are periodically inspected using non-destructive examinations, for example ultrasonic, eddy current and radiographic examinations, in order to determine their integrity. These components include nuclear power plant items such as vessels, containments, piping systems, pumps, valves, tubes and core support structure. Steam generator tubes have an important safety role because they constitute one of the primary barriers between the radioactive and non-radioactive sides of the nuclear power plant. There is potential that if a tube bursts while a plant is operating, radioactivity from the primary coolant system could escape directly to the atmosphere. Therefore, in-service inspections are critical in maintaining steam generator tube integrity. In general, the eddy current testing is widely used for the inspection of steam generator tubes due to its high inspection speed and flaw detectability on non-magnetic tubes. However, it is not easy to analyze correctly eddy current signals because they are influenced by many factors. Therefore, the performance of eddy current data analysts for steam generator tubing should be demonstrated comprehensively. In Korea, the performance of steam generator tubing analysts has been demonstrated using the Qualified Data Analyst program. This paper describes the performance demonstration program for steam generator tubing analysts and its implementation results in Korea. The pass rate of domestic analysts for this program was 71.4%.

Effect of Water-impregnation on Steam Explosion of Pinus densiflora

  • Jung, Ji Young;Ha, Si Young;Yang, Jae-Kyung
    • Journal of the Korean Wood Science and Technology
    • /
    • 제47권2호
    • /
    • pp.189-199
    • /
    • 2019
  • This study addresses the biorefinery feedstock from Pinus densiflora. This raw material is a major tree species in the Republic of Korea; it is renewable, has cost-effective, and is readily available. In this study, steam explosion of P. densiflora was performed in a reactor at $225^{\circ}C$ and with 1 to 13 min reaction times with or without previous water impregnation. The combined severity factor (Ro), which is an expression relating the reaction temperature and reaction time used in the steam explosion treatment, ranged from 3.68 to 4.79. The influence of both impregnation and steam explosion conditions were investigated by examining color variations, chemical composition, and mass balance on the pretreated solids. The results showed that steam-exploded P. densiflora that was not impregnated with water exhibited significantly darker color (chroma 28.8-41.4) than water-impregnated and steam-exploded P. densiflora (chroma 18.8-37.3). The increased ${\alpha}$-cellulose and lignin contents were detected as the severity factor increased. Furthermore, the ${\alpha}$-cellulose and lignin contents in the non-impregnated/steam-exploded P. densiflora were higher than those in the water-impregnated/steam-exploded P. densiflora. However, the decreased holocellulose content was detected as the severity factor increased. In mass balance, the holocellulose yield from water-impregnated/steam-exploded P. densiflora was higher than that from the non-impregnated P. densiflora.

잎담배의 팽화방법에 따른 팽화율 및 내용성분 특성 (Physico-chemical Properties of leaf tobacco by expansion processes.)

  • 김병구;김기환;정한주;이경구;이태호
    • 한국연초학회지
    • /
    • 제18권1호
    • /
    • pp.76-84
    • /
    • 1996
  • Flue-cured tobaccos(cv. NC82, grade AB3O-1) expanded by super steam, volatile organic solvents(tricuorofluoromethane, propane), carbon dioxide, nitrogen, and by freeze-drying were examined for their physico-chemical properties. The expanding rate by using the organic solvents or carbon dioxide at the impregnated pressure was 70% or more, whereas the rate by super steam and freeze-drying was 49.4 and 42.9%, respectively. The contents of total sugar, alkaloid and ether extracts of the expanded tobacco by organic solvents or carbondioxide were decreased to 27.6, 20% or more, and 13%, respectively, when compared to non-expanded one. The contents of citric acid of the tobacco expanded by using trichlorofluoromethane and carbon dioxide were increased to 19.1, 14.0%, respectively. Linoleic acid in the tobacco expanded by super steam or trichlorofluoromethane was also increased to 17.3%, but malonic acid in the tobacco expanded by super steam was 18.5% less than that in the non-expanded one. Nineteen essential oil among 22 assayed in this experiment were decreased in the expanded tobaccos. Key words : expanding method, tobacco, physico-chemical properties.

  • PDF