• Title/Summary/Keyword: non-standard type

Search Result 361, Processing Time 0.026 seconds

A NEW STOCHASTIC EVALUATION THEORY OF ARBITRARY ACOUSTIC SYSTEM RESPONSE AND ITS APPLICATION TO VARIOUS TYPE SOUND INSULATION SYSTEMS -EQUIVALENCE TRANSFORMATION TOWARD THE STANDARD HERMITE AND/OR LAGUERRE EXPANSION TYPE PROBABILITY EXPRESSIONS

  • Ohta, Mitsuo;Ogawa, Hitoshi
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.692-697
    • /
    • 1994
  • In the actual sound environmental systems, it seems to be essentially difficult to exactly evaluate a whole probability distribution form of its response fluctuation, owing to various types of natural, social and human factors. Up to now, we very often reported two kinds of unified probability density expressions in the standard expansion from of Hermite and Laguerre type orthonormal series to generally evaluate non-Gaussian, non-linear correlation and/or non-stationary properties of the fluctuation phenomenon. However, in the real sound environment, there still remain many actual problems on the necessity of improving the above two standard type probability expressions for practical use. In this paper, first, a central point is focused on how to find a new probabilistic theory of practically evaluating the variety and complexity of the actual random fluctuations, especially through introducing some equivalence transformation toward two standard probability density expressions mentioned above in the expansion from of Hermite and Laguerre type orthonormal series. Then, the effectiveness of the proposed theory has been confirmed experimentally too by applying it to the actual problems on the response probability evaluation of various sound insulation systems in an acoustic room.

  • PDF

Recognition of Human Typing Pattern Using Neural Network (신경망을 이용한 휴먼 타이핑 패턴 인식)

  • Bae, Jung-Gi;Kim, Byung-Whan;Lee, Sang-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.449-451
    • /
    • 2006
  • With the increasing danger of personal information being exposed, a technique to protect personal information by identifying a non-user in case it is exposed. A study to construct a neural network recognizer for developing a economical and effective user protecting system. For this, time variables regarding user typing patterns from a pattern extraction device. With the variations in the standard deviation for the collected time variables, non-user patterns were generated. The recognition performance increased with the increase in the standard deviation and a higher recognition was achieved at 2.5. Also, five types of training data were generated and the recognition performance was examined as a function of the number of non-user patterns. With the increase in non-suer patterns, the recognition error quantified in the root mean square error (RMSE) was reduced. The smallest RMSE was obtained at the type 5 and 90 non-user patterns. In overall, the type 3 model yielded the highest recognition accuracy Particularly, a perfect recognition of 100% was achieved at 45 non-user patterns.

  • PDF

A Study on the Certification of Miscellaneous Non-Required Electrical Equipment (부가적인 전기 장비품의 인증 방안)

  • Kim, IL-Young;Suh, Jang-Won
    • Journal of Aerospace System Engineering
    • /
    • v.1 no.4
    • /
    • pp.1-6
    • /
    • 2007
  • The interest about the installation and certification for miscellaneous non-required electrical equipment is being increased in the domestic aviation industries. In this paper, the minimum applicable requirements in Airworthiness Standard and the acceptable means of compliance which can be applied to installation and certification for miscellaneous non-required electrical equipment is being researched. As a case study, galley certification procedures are presented by electrical load analysis, installation of warning devices and installation requirements.

  • PDF

Non-contact type AFM using frequency separation scheme (주파수응답 분리방법을 이용한 비접촉식 AFM)

  • 이성규;염우섭;박기환;송기봉;김준호;김은경;박강호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.375-378
    • /
    • 2002
  • In this paper, the frequency response separation scheme is proposed for high scanning speed and simple structure of non-contact type of AFM. A self-sensing cantilever is attached on the actuator for detect the atomic force between tip and the media surface. VCM or PZT are used for actuator. This paper presents the method to simplify the actuator structure and the performance of each actuator for non-contact type AFM. Based on the frequency response separation scheme, the only one actuator plays roles 1311owing low frequency surface and modulating self-sensing cantilever tip in contrast with convention non-contact type AFM. 10 ${\mu}{\textrm}{m}$ standard grid sample imaged to verify proposed scheme. This result shows the possibility simplifying the actuator structure and reducing cost of non-contact type AFM.

  • PDF

Firing Data Calculation Algorithm for Smart Weapon System Under Non-standard Conditions (스마트무장 비 표준조건 사격제원 산출 알고리즘)

  • Moon, Kyujin;Jeong, Ui-Taek;Lee, Yongseon;Choi, Sungho;Ryoo, Chang-Kyung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.4
    • /
    • pp.233-240
    • /
    • 2022
  • The smart weapon system is a new weapon system of the future battlefield environment as a miniature guided weapon that performs precision strike missions through terminal phase guidance. However, it has small coverage to guide due to its low maneuverability because the smart weapon is controlled by using actuator of piezoelectric drive type due to the structural limitations. In this paper, we propose a firing data calculation algorithm under non-standard conditions to increase the effectiveness of the smart weapon. The proposed algorithm calculates firing data under non-standard conditions by calibrating firing data under standard conditions using information acquired in battlefield environments. The performance of the proposed algorithm is verified by numerical simulations under various conditions.

Operation and Improvement Cases of FGD Non-leakage Type Gas-Gas Heater(GGH) for Coal Fired Power Plants (석탄화력 탈황설비 Non-leakage Type Gas-Gas Heater(GGH) 운영 및 개선사례)

  • Seong, Kijong;Lee, Changsik
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.4
    • /
    • pp.35-42
    • /
    • 2017
  • This case covers the issues related to the operation problem, cause analysis and improvement cases of the FGD that employed the non-leakage type GGH in coal-fired power plant for the first time in Korea. In the Cooler, there was a main problem that the tube is damaged by the ash cutting due to the high velocity of flue gas in the duct and by the weak wear resistance of material. In the Reheater, there was a main problem that the tube was corroded due to chlorine and sulfur in the circumstance of the low temperature. In order to solve those problems, we have improved the Reheater tube and tube fins by coating enamel to reduce corrosion rate.

Concentration of elemental ions released from non-precious dental casting alloys (치과주조용 비귀금속 합금의 금속 용출 수준)

  • Sakong, Joon;Park, Soo-Chul
    • Journal of Technologic Dentistry
    • /
    • v.35 no.1
    • /
    • pp.1-17
    • /
    • 2013
  • Purpose: This study was to assess the extents of the release of metals from the non-precious alloys used for dental casting by measuring the differences in the extents of the release of metals by types of alloys, pH level and elapsed time. Methods: Uniform-sized specimens(10 each) were prepared according to the Medical Device Standard of the Korea Food and Drug Administration(2010) and International Standard Organization(ISO22674, 2006), using four types of alloys(one type of Ni-Cr and one type of Co-Cr used for fixed prosthesis, and one type of Ni-Cr and one type of Co-Cr used for removable prosthesis). A total of 12 metal-release tests were performed at one-day, three-day, and two-week intervals, for up to 20 weeks. The metal ions were quantified using an Inductively Coupled Plasma-Atomic Emission Spectrometer. Results: The results showed that the extent of corrosion was higher in the ascending order of Jdium-$100^{(R)}$, Bellabond-$Plus^{(R)}$, Starloy-$C^{(R)}$, and Biosil-$F^{(R)}$. The lower the pH and the longer the elapsed time were, the greater the increase in metal corrosion. At pH 2.4, the release of Ni from Jdium-$100^{(R)}$, a Ni-Cr alloy, was up to 15 times greater than the release of Co from the Co-Cr alloy from two weeks over time, indicating that the Ni-Cr alloy is more susceptible to corrosion than the Co-Cr alloy. Conclusion: It is recommended that Co-Cr alloy, which is highly resistant to corrosion, be used for making dental prosthesis with a non-precious alloy for dental casting, and that non-precious alloy prosthesis be designed in such a way as to minimize the area of its oral exposure. For patients with non-precious alloy prostheses, a test of the presence or absence of periodontal tissue inflammation or allergic reaction around the prosthesis should be performed via regular examination, and education on the good management of the prosthesis is needed.

A Study on Ease for the Skirt of Stretch Fabric according to the Body Types(I) (신축성 직물 스커트의 체형별 여유분에 관한 연구(I)-표준 체형을 중심으로-)

  • 설경희;서미아
    • The Research Journal of the Costume Culture
    • /
    • v.9 no.3
    • /
    • pp.433-446
    • /
    • 2001
  • Recently, according to changes in fashion trends, the importance of stretch fabric stands out. A lot of studies on non-stretch woven fabrics have been made, but few studies on stretch fabrics has been made yet. Especially, the study on ease for the patterns, according to body types, of stretch has not been made at all. The purpose of this study was to make clear reduction ratio due to the stretch ratio and to find out the ease for the patterns of stretch skirt according to standard body type to improve the aesthetics and wearing satisfaction. Therefore, fundamental data for aesthetic and functional patternmaking of the stretch skirt can be suggested. The results from the study were as follows: 1. The results from the appearance test were as follows. For the ease on waist, W+0㎝ and W-1㎝ for standard body type were suggested for the best fit. For the ease on hip, H+2㎝ and H+0㎝ for standard body type were suggested for the best wearing best fit. 2. The results from wearing satisfaction test were as follows. W+0㎝, H+2㎝ for standard body type were suggested for the best wearing satisfaction. 3. Based on the results from the above tests, the pattern reduction ratios for stretch skirt were as follows: pattern reduction ratio 3.0∼4.6% of waist, 2.1∼4.3% of hip for standard body type were suggested for the appropriate reduction ratio for stretch skirt. 4. The result from this study for stretch skirt was as follows: For standard body type, W+0㎝, W-1㎝ for waist and H+2㎝, H+0㎝ for hip were appropriate for stretch skirt pattern.

  • PDF

Mating Type Alleles of Magnaporthe grisea in Korea (한국에서 분리한 도열병균의 교배형)

  • 최우봉;이용환
    • Korean Journal Plant Pathology
    • /
    • v.10 no.4
    • /
    • pp.249-253
    • /
    • 1994
  • Twenty six isolates of Magnaporthe grisea originated from rice and other gramineous hosts Korea were tested for mating type with MAT1-1 and MAT1-2 standard isolates. Ninety three and 64% of rice and grass isolated mated and produced perithecia with standard isolates, respectively. Both mating types were found from rice and non-rice isolates, but MAT1-1 allele of M. grisea was predominant in Korea.

  • PDF