• 제목/요약/키워드: non-local measurement

검색결과 88건 처리시간 0.025초

Recommended Rice Intake Levels Based on Average Daily Dose and Urinary Excretion of Cadmium in a Cadmium-Contaminated Area of Northwestern Thailand

  • La-Up, Aroon;Wiwatanadate, Phongtape;Pruenglampoo, Sakda;Uthaikhup, Sureeporn
    • Toxicological Research
    • /
    • 제33권4호
    • /
    • pp.291-297
    • /
    • 2017
  • This study was performed to investigate the dose-response relationship between average daily cadmium dose (ADCD) from rice and the occurrence of urinary cadmium (U-Cd) in individuals eating that rice. This was a retrospective cohort designed to compare populations from two areas with different levels of cadmium contamination. Five-hundred and sixty-seven participants aged 18 years or older were interviewed to estimate their rice intake, and were assessed for U-Cd. The sources of consumed rice were sampled for cadmium measurement, from which the ADCD was estimated. Binary logistic regression was used to examine the association between ADCD and U-Cd (cut-off point at $2{\mu}g/g$ creatinine), and a correlation between them was established. The lowest estimate was $ADCD=0.5{\mu}g/kg\;bw/day$ [odds ratio (OR) = 1.71; with a 95% confidence interval (CI) 1.02-2.87]. For comparison, the relationship in the contaminated area is expressed by $ADCD=0.7{\mu}g/kg\;bw/day$, OR = 1.84; [95 % CI, 1.06-3.19], while no relationship was found in the non-contaminated area, meaning that the highest level at which this relationship does not exist is $ADCD=0.6{\mu}g/kg\;bw/day$ [95% CI, 0.99-2.95]. Rice, as a main staple food, is the most likely source of dietary cadmium. Abstaining from or limiting rice consumption, therefore, will increase the likelihood of maintaining U-Cd within the normal range. As the recommended maximum ADCD is not to exceed $0.6{\mu}g/kg\;bw/day$, the consumption of rice grown in cadmium-contaminated areas should not be more than 246.8 g/day. However, the exclusion of many edible plants grown in the contaminated area from the analysis might result in an estimated ADCD that does not reflect the true level of cadmium exposure among local people.

표면유속 측정을 통한 지표-평균유속 관계식 일반화 적용성 검토 (Applecation of emprical index velocity equation by local non-contact surface velocity measurement)

  • 이신재;이시윤;이동규
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2019년도 학술발표회
    • /
    • pp.274-274
    • /
    • 2019
  • 최근 하천에서 실시간 유량측정을 위하여 유수에 접촉 또는 비접촉 유속측정방식을 이용한 자동유량측정시스템이 설치 운영되고 있으며, 주로 지표유속법(index velocity method)이 적용되고 있다. 지표유속법 적용을 위해서는 다양한 범위에서 측정된 지표유속과 평균유속관계를 분석해야한다. 그러나 유속계 설치초기에는 측정된 유속이 없기 때문에 측정된 유량을 신뢰하기가 어렵다. 본 연구에서는 비접촉 유속계인 전자파표면유속계(MU2720)로 측정된 표면유속과 지표유속법을 이용하여 일반적인 하천에서 비접촉(레이다 또는 전자파표면유속계 등) 방식에 의한 자동유량측정 시스템 운영초기에 적용 가능한 경험적 지표-평균유속 관계식을 개발하여 검토하였다. 연구 대상지점은 한탄강(1개소), 홍천강(3개소), 내린천(2개소), 북천(1개소), 탄천(1개소), 섬강(1개소) 등 6개 하천 9개 지점이며, 2016~2018년에 지점별로 측정된 총 103개(6~26개)의 측정자료를 이용하여 분석하였다. 지점별 최대유속이 발생하는 지표유속과 평균유속과의 관계를 분석한 결과 결정계수(R2)가 0.8848(원주시(문막교))~0.9874(서울시(대곡교))로 평균 0.9626를 보여 매우 높은 상관성을 보였다. 또한 9개 지점의 모든 유속자료를 통합하여 지표-평균유속 관계식을 개발하였다. 그 결과 결정계수는 0.9247를 보였으며, 유속분포가 일반적이지 않은 홍천강의 홍천군(반곡교), 섬강의 원주시(문막교) 지점 자료를 제외한 7개 지점의 자료만으로 지표-평균유속 관계식을 개발한 결과 결정계수가 0.9603으로 매우 높은 상관성을 보였다. 이러한 결과를 볼 때 일반적인 유속분포(포물선형태)를 가진 하천은 본 연구에서 7개 지점으로 개발된 지표-평균유속 관계식을 운영초기에 활용할 수 있을 것으로 판단된다.

  • PDF

DN 250만 250℃고온 스팀환경에서 운전되는 단열 브러쉬 실 마모효과에 관한 실험적 연구 (Experimental Study on the Wear Effects of a Brush Seal in DN 2.5million in a 250℃ High - temperature Steam Environment)

  • 하윤석;하태웅;이용복
    • Tribology and Lubricants
    • /
    • 제35권2호
    • /
    • pp.99-105
    • /
    • 2019
  • This study presents an experimental investigation of the wear and oxidation of the bristles of a brush seal in a super-heated steam environment. We construct a model reflecting normal force and radial interference to predict the amount of wear. To monitor the volume loss of the bristle induced by the swirl phenomenon of the rotor, we measure the clearance between the rotor and the brush seal by using a non-contact 3-D device. We calculate the area by using the area-wise measurement method. Considering the obvious brush seal wear variables, we use two disks with different roughness($Ra=0.1{\mu}m$ and $100{\mu}m$) to determine the effect of roughness on wear. Considering an actual steam turbine, we utilize a steam generator and super-heater to generate a working fluid (0.95MPa, 523.15K) that has high kinetic energy. We observe the abrasion of the bristles in the hot steam environment through a scanning electron microscope image. This study also conducted energy dispersive X-ray (EDX) analysis for a qualitative evaluation of local chemistry. The results indicate that the wear and elimination of bristles occur on the disk with high roughness, and the weight increases due to oxidation. Furthermore these results, reveal that the bristle oxidation is accelerated more under super-heated steam conditions than under conditions without steam.

Experimental investigation on flexural behaviour of HSS stud connected steel-concrete composite girders

  • Prakash, Amar;Anandavalli, N.;Madheswaran, C.K.;Lakshmanan, N.
    • Steel and Composite Structures
    • /
    • 제13권3호
    • /
    • pp.239-258
    • /
    • 2012
  • In this paper, experimental investigations on high strength steel (HSS) stud connected steel-concrete composite (SCC) girders to understand the effect of shear connector density on their flexural behaviour is presented. SCC girder specimens were designed for three different shear capacities (100%, 85%, and 70%), by varying the number of stud connectors in the shear span. Three SCC girder specimens were tested under monotonic/quasi-static loading, while three similar girder specimens were subjected to non-reversal cyclic loading under simply supported end conditions. Details of casting the specimens, experimental set-up, and method of testing, instrumentation for the measurement of deflection, interface-slip and strain are discussed. It is found that SCC girder specimen designed for full shear capacity exhibits interface slip for loads beyond 25% of the ultimate load capacity. Specimens with lesser degree of shear connection show lower values of load at initiation of slip. Very good ductility is exhibited by all the HSS stud connected SCC girder specimens. It is observed that the ultimate moment of resistance as well as ductility gets reduced for HSS stud connected SCC girder with reduction in stud shear connector density. Efficiency factor indicating the effectiveness of high strength stud connectors in resisting interface forces is estimated to be 0.8 from the analysis. Failure mode is primarily flexure with fracturing of stud connectors and characterised by flexural cracking and crushing of concrete at top in the pure bending region. Local buckling in the top flange of steel beam was also observed at the loads near to failure, which is influenced by spacing of studs and top flange thickness of rolled steel section. One of the recommendations is that the ultimate load capacity can be limited to 1.5 times the plastic moment capacity of the section such that the post peak load reduction is kept within limits. Load-deflection behaviour for monotonic tests compared well with the envelope of load-deflection curves for cyclic tests. It is concluded from the experimental investigations that use of HSS studs will reduce their numbers for given loading, which is advantageous in case of long spans. Buckling of top flange of rolled section is observed at failure stage. Provision of lips in the top flange is suggested to avoid this buckling. This is possible in case of longer spans, where normally built-up sections are used.

덴던 비파괴평가를 위한 Total Flux Leakage에서 높은 측정빈도의 데이터를 획득하기 위한 진폭복조의 응용 (Application of Amplitude Demodulation to Acquire High-sampling Data of Total Flux Leakage for Tendon Nondestructive Estimation )

  • 이주형;곽임종;조창빈;최지영;박광연
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권2호
    • /
    • pp.17-24
    • /
    • 2023
  • 이 논문은 total flux leakage (TFL) 방법을 이용해 외부텐던을 비파괴검사 하는 솔레노이드 형태의 센서의 측정 신호를 후처리하는 방법을 소개한다. 기존에 개발된 TFL 솔레노이드 센서는 1차 코일과 2차 코일로 이루어져 1차 코일에 정현파 형태의 교류를 입력하면 2차 코일에 그 미분에 비례하는 신호가 측정된다. 이때 진폭은 텐던의 단면에 비례하므로 파단 및 부식 여부를 확인할 수 있다. 따라서 TFL센서의 측정신호에서 진폭정보를 추출 하는 것이 중요한데 기존에는 단순히 극댓값을 모아 진폭정보를 취득했다. 하지만 이 방법을 사용하면 측정빈도가 크게 낮아져 추가적인 신호처리 및 인공지능 적용에 많은 제약이 생긴다. 이 논문은 높은 측정빈도를 가진 진폭정보를 추출하기 위해 진폭복조를 응용해 진폭정보를 획득하는 방법을 제시한다. 진폭복조를 이용해 진폭정보를 취득하면 측정빈도를 원시신호와 동일한 수준으로 유지할 수 있다. 이 방법은 TFL센서의 1차 코일 입력 주파수 선택과 센서를 외부텐던에 적용하는 속도 등에 제약을 없애주어 개발 방향에 많은 자유도를 부여한다. 또한 높은 측정빈도를 유지하므로 추가적인 신호처리나 인공지능 등을 활용 하는데 유리함을 제공한다. 제안된 방법은 실내실험을 통해 검증 되었으며 기존 방법과 비교해 어떤 장점이 있는지 분석했다. 제시된 예제의 경우 진폭복조를 사용한 방법이 기존 방법에 비해 100배 높은 측정빈도를 제공 하는 것을 확인 할 수 있었다. 주어진 상황과 구체적인 장비 설정에 따라 차이가 있겠지만 대부분의 경우 진폭복조를 사용해 진폭정보를 추출하면 기존 방법 대비 만족할만한 결과를 얻을 수 있을 것이다.

백서 두개골 결손부의 치유과정에 alendronate가 미치는 영향 (The Effects of Alendronate on Healing of the Calvarial Defect in Rats)

  • 김재형;이재목;박진우;서조영
    • Journal of Periodontal and Implant Science
    • /
    • 제34권4호
    • /
    • pp.733-746
    • /
    • 2004
  • Bisphosphonates는 파골세포에 의한 골흡수를 방지하는 물질로 알려져 있으며 임상에서 널리 쓰이고 있다. 그 중 Alendronate는 Aminobisphosphonates의 한 종류로 non-aminobisphosphonates인 etidronate보다 100-1000배 더 강한 효과를 보이는 것으로 알려져 있다. 본 실험의 목적은 백서두개골 결손부의 골재생을 실험모델로 하여 alendronate의 국소투여 효과를 알아보는 것으로 액체의 흡수성과 골전도성이 우수한 것으로 알려진 collagen membrane을 사용하여 결손부 양측에 alendronate와 physiologic saline을 각각 적용하여 1주, 2주, 4주의 조직학적 치유양상, 파골세포활성도, 경도를 평가하였다. 조직학적 치유양상은 1주째 collagen membrane에 의한 염증성 침윤이 나타났으며 2주째부터 골성회복이 관찰되었고 4주째 완전한 골성회복을 보여 각주별 실험군, 대조군 공히 유사한 양상을 보였고 실험에 사용한 $200{\mu}g$의 용량은 조직학적으로 관찰할만한 골재생의 향상을 위해서는 부족한 용량으로 사료되는 바이다. TRAP(+) cell은 1주째 대조군에 비해 실험군에서 유의하게 적은 수를 보였으며(p<0.01) 2주와 4주째는 유의한 차이를 나타내지 않았고 경도측정에서는 2주째 대조군에 비해 실험군에서 유의하게 높은 경도를 보였으며 4주째 유의한 차이를 나타내지 않았다(p<0.05). 이상의 실험에서 alendronate는 골조직 치유과정의 초기에 파골세포의 활성도와 경도에 다소 영향을 미친 것으로 사료되며 향후 골조직 재생을 위한 임상적용에 응용을 위해서는 치유과정을 더욱 향상시킬 수 있는 추가적인 연구가 필요하리라 사료된다.

전자파 위험 지형도의 상이한 구성: 지중 송전선로 위험 논쟁을 중심으로 (Constructing Topographies of EMF Risks from Underground Power Lines)

  • 김주희
    • 과학기술학연구
    • /
    • 제19권3호
    • /
    • pp.119-166
    • /
    • 2019
  • 일상 공간을 가득 메우고 있는 다양한 종류의 전자파. 그중에서도 송전선에서 발생하는 전자파의 위험성은 고압 송전탑이 건설될 때마다 여러 차례 논란이 되었는데, 이때 대안으로 떠오른 것이 바로 송전선을 땅속에 묻는 송전선로 지중화(地中化)였다. 하지만 2014년 서울의 한 초등학교 과학 교사가 지중 송전선로 구간의 전자파 측정 결과를 환경보건 시민센터에 제보하면서, 송전선로 지중화에 대한 논의는 새로운 국면을 맞이하게 된다. 송전탑보다 지중 송전선로에서 발생하는 전자파가 더 세고, 따라서 더 유해할 수도 있다는 주장이 제기된 것이다. 이후 지중 송전선로 전자파의 위험성을 둘러싸고 벌어진 논쟁에서 환경보건시민센터와 국립환경과학원은 눈에 보이지 않는 전자파 위험의 지형을 서로 다르게 재현해냈다. 이에 본 논문은 양측이 전자파를 측정할 때 측정 지점, 측정기기, 측정 높이의 측면에서 어떤 차이를 보였으며, 나아가 측정값의 의미를 해석하고 그것을 지도나 표로 재현하는 과정에서 다양한 종류의 표준들(인체보호기준, 측정의 국제 가이드라인, 발암물질 그룹 분류)을 어떻게 동원했는지를 살펴본다. 서울의 지중 송전선로에서 발생하는 전자파를 두고 벌어진 이와 같은 위험 논쟁은 그동안 주목받지 못했던, 전자파 장기 노출의 비열적 영향에 대한 관심을 불러일으키는 것이었으며, 송전선로 지중화가 과연 전자파 문제의 해결책인지에 대해서도 의문을 갖게 하는 것이었다. 나아가 이는 송전선로 지중화율이 약 90%에 육박하는 서울이라는 공간이 안전하게 관리되는 일상 공간인지, 통제되지 않는 위험한 공간인지에 대해 상충되는 대답을 암시하는 것이기도 했다.

ARIMA와 VAR·VEC 모형에 의한 부산항 물동량 예측과 관련성연구 (Study on the Forecasting and Relationship of Busan Cargo by ARIMA and VAR·VEC)

  • 이성윤;안기명
    • 한국항해항만학회지
    • /
    • 제44권1호
    • /
    • pp.44-52
    • /
    • 2020
  • 세계적인 장기경기침체 속에서 보다 정확한 물동량 예측은 항만정책 수행에 중요하다. 따라서, 본 연구에서는 부산항 컨테이너 물동량(수출입화물과 환적화물)을 단변량 모형인 ARIMA 뿐만 아니라 인과관계가 있을 것으로 예상되는 경제규모(한국, 중국, 미국의 국내총생산), 금리수준 그리고 경기변동을 고려한 벡터자기회귀모형과 벡터오차수정모형을 활용하여 추정하고 비교하였다. 측정자료는 2014년 1월부터 2019년 8월까지 월별 부산항 컨테이너 물동량이다. 분석결과에 의하면, 수출입물동량 시계열은 비교적 안정적(stationary)이어서 VAR에 의해 추정하였고 환적화물은 불안정적(non-stationary)하지만, 경제규모, 금리 및 경기변동과 공적분(장기적인 균형관계)를 띠고 있어 VEC모형으로 추정하였다. 추정결과, 안정적인 수출입화물 추정에서는 단변량 모형인 ARIMA가 우수하고 추세가 있는 환적화물은 다변량모형인 VEC모형이 보다 예측력이 우수한 것으로 나타나고 있다. 특히 수출입화물은 우리나라 경제규모와 관련이 있고, 환적화물은 중국과 미국 경제규모와 밀접한 관련이 있다. 또한 중국 경제규모가 미국에 비하여 더 밀접하게 나타나고 있어 환적화물 증대전략에 시사점을 주고 있다.

EIS(Electro Interstitial Scan) 방법의 임상적 유효성 연구 (Evaluation of Clinical Usefulness of EIS(Electro Interstitial Scan))

  • 김수찬;배장한;전민호;김재욱
    • 전자공학회논문지
    • /
    • 제52권12호
    • /
    • pp.124-133
    • /
    • 2015
  • 전기체간스캔법(EIS, electro interstitial scan)은 미세 직류전류를 인체의 사지말단 또는 국소적 인가를 통해 인체의 전류 반응을 기준으로 인체의 질병 유무를 판별할 수 있는 비침습적인 질병 스크리닝 방법으로 가능성을 보이고 있다. 프랑스에서 개발된 DDFAO는 다채널 EIS로 다양한 질병, 특히 당뇨와 같은 내분비 기관의 진단에 효과적이라고 주장한다. 본 연구에서는 RC 팬텀 모델을 이용하여 DDFAO의 측정의 반복성과 민감도를 확인하고, 정상군과 당뇨 질환군을 대상으로 임상적 유용성을 검정하였다. 그 결과, 팬텀을 이용할 경우, 반복 측정시 값의 변화가 없고 팬텀 특성이 변화될 때 DDFAO의 측정 결과도 변화되었다. 그러나 임상 측정에 있어서 6개의 표면 전극을 이용하여 비침습적 방법으로 정상인과 당뇨병 환자의 구별은 어려울 뿐만 아니라 반복성과 정확성도 우수하지 않았다. 그러나, 이러한 문제점에도 불구하고 측정 방법의 편리성과 간편성으로 인해 국소적인 영역보다 인체 전반적인 특성을 파악하는 스크린 장비로써의 개발 가능성은 여전히 보이고 있기에 EIS에 대한 다양한 기반 연구가 필요하다.

골반부 방사선 치료 환자에서 in vivo 선량측정시스템의 임상적용 (Clinical Application of in Vivo Dosimetry System in Radiotherapy of Pelvis)

  • 김보경;지의규;허순녕;이형구;하성환
    • Journal of Radiation Protection and Research
    • /
    • 제27권1호
    • /
    • pp.37-49
    • /
    • 2002
  • 방사선치료 시 종양에 정확한 양의 방사선을 조사하는 것은 국소 재발을 방지하고 합병증의 빈도를 낮춰 효과적인 치료를 가능하게 하는 중요한 요소이다. 종양에 조사되는 방사선량의 측정을 통해 치료의 정확성을 확인하기 위한 여러 방법들이 시도되고 있으며, 투과선량을 이용한 측정법도 그 중 한 예로 비침습적이며 매 치료 시 측정이 가능한 장점을 가지고 있다. 본 교실에서는 투과선량을 이용한 in vivo 선량측정시스템과 임의의 치료 조건에서 투과선량을 계산하기 위한 알고리즘을 개발하였다. 본 교실에서 개발한 in vivo 선량측정시스템의 단기간 및 장기간의 재현성을 확인하고, 환자의 방사선치료에서의 이용 시 발생할 수 있는 문제점을 파악하고 알고리즘의 정확성을 확인하기 위하여 본 연구를 시행하였다. 2000년 7월 25일부터 8월 14일 사이에 방사선치료를 시행 받은 환자 66명을 대상으로 투과선량의 측정을 시행하였으며, 이 중 골반부위의 방사선 치료를 3회 이상 시행 받은 11명의 환자를 대상으로 측정선량과 예측선량의 비교 분석을 시행하였다. 측정시스템의 재현성의 확인을 위하여 환자의 치료 전 및 치료 중 매시간 기준 조사조건에서 측정치를 확인하였다. 일별 및 일 중 변동은 ${\pm}2%$ 이내로 재현성을 확인할 수 있었다. 본 시스템의 사용 시 별다른 문제점은 없었으나, 2명의 흉부 치료환자에서 투과선이 치료용테이블의 측면 금속을 관통하는 문제가 발생하였다. 골반부위 환자에서는 골반부위의 불균질조직에 의한 영향의 확인을 위하여, CT 및 simulation film을 이용하여 골 조직의 두께를 확인하여 보정 전 및 후의 값을 비교하였다. 전후방 및 후방조사야의 경우 골 조직의 보정을 시행하지 않은 경우 평균오차가 -5.20% 내지 +2.20%이었으며, 보정을 시행한 경우 -0.62%내지 +3.32%로 환자에 따라 정도의 차이는 있으나 골 보정이 필요함을 확인할 순 있었다. 측정치와 예측치 간 오차의 표준편차는 1.19%내지 2.46%로서 재현성이 높음을 확인할 수 있었다. 좌우 측방조사야에서 골 보정을 시행하지 않은 경우 평균오차는 -10.80%내지 +3.46%로서 골 조직의 보정이 필요하지 않은 1인의 환자를 제외하면 모두 음수 값을 지녔고, 보정을 시행한 경우 -0.55% 내지 +3.50%의 평균오차를 지녀 골 보정의 필요성을 확인할 수 있었다. 측정치와 예측치 간 오차의 표준편차는 1.09%내지 6.98%로 전후방조사야의 경우보다 재현성이 낮음을 알 수 있었다. 복와위로 방사선치료를 시행 받은 환자의 경우를 제외하면, 표준편차는 1.09%내지 3.12%로 1례 외에는 2.57% 이내로 재현성이 높음을 확인할 수 있었다. 본 실험을 통하여 in vivo 선량측정시스템의 안전성과 재현성을 확인할 수 있었다. 정확한 예측치를 얻기 위하여 불균질 조직이 조사야에 포함되는 경우 보정이 요구되며, 골반의 경우 골 조직의 보정이 중요한 요인임을 알 수 있었다. 이를 위하여 불균질 조직에 대한 정확한 정보가 요구되며, 이는 CT 영상을 이용하는 것이 크게 도움이 되리라 생각된다.