• Title/Summary/Keyword: non-invasive measuring

Search Result 86, Processing Time 0.03 seconds

High-resolution imaging of microneedles in biological tissue with optical coherence tomography (광간섭 단층 영상기술을 이용한 생체 내 microneedle 삽입 구조 영상)

  • Kim, Hun;Heo, Jung;Lee, Kang Ju;Ryu, Su Ho;Ryu, Won Hyoung;Joo, Chulmin
    • Transactions of the Society of Information Storage Systems
    • /
    • v.9 no.1
    • /
    • pp.17-21
    • /
    • 2013
  • Optical coherence tomography (OCT) allows non-invasive, cross-sectional optical imaging of biological tissue with high spatial resolution and acquisition speed. In principle, it is analogous to ultrasound imaging, but uses near-infrared light instead of ultrasound, measuring the time-delay of back-scattered light from within biological tissue. Compared to ultrasound imaging, it exhibits superior spatial resolution (1~10 um) and high sensitivity. Therefore, OCT has been applied to a wide range of applications such as cellular imaging, ophthalmology and cardiology. Here, we describe a novel application of OCT technology in visualizing microneedles embedded in tissue that is developed to deliver drugs into the dermis without the injection mark in the human skin. Detailed three-dimensional structural images of microneedles and biological tissues were obtained. Examining structural modification of microneedles and tissues during insertion process would enable to evaluate performance of various types of microneedles in situ.

Noninvasive Detection of Specific Diagnostic Biomarkers for Atopic Dermatitis

  • Chang, Jeong Hyun
    • Biomedical Science Letters
    • /
    • v.25 no.1
    • /
    • pp.15-22
    • /
    • 2019
  • The diagnosis of atopic dermatitis (AD) includes a test that checks allergen-mediated skin reactions and a method of measuring the total IgE and allergen-specific IgE in blood. However, these test methods are performed directly on the patient, which cause some pain or discomfort. In addition, the skin response test or IgE may result in false negative in about 20% of patients. In the present study, to identify specific biomarkers, HaCaT cells were used as a human keratinocyte that make up the skin, were treated IL-4 and IL-13 for 24 hours to induce a situation similar to keratinocytes in AD patients. In the HaCaT cells, pro-inflammatory cytokine such as IL-5, IL-6, and MCP-1 were increased by IL-4 and IL-13 and skin barrier proteins was reduced by IL-4 and L-13. This results showed that a situation similar to the stratum corneum of an actual patient is induced in HaCaT cells. And then the secretions of Kallikrein (KLK) 5 and KLK7 protease were checked by enzyme-linked immunosorbent assay (ELISA). It was specifically increased by IL-4 and IL-13. This showed that AD-related protease can be detected at the protein level using keratinocytes that can be taken in a non-invasive manner and suggested the possibility of applying it to AD diagnosis.

Study on the interrelationship between the PWV and the temperature difference (맥파전달속도(PWV)와 말초체열분포(DITI)와의 관계 연구)

  • Lee, Yoon-Jae;Cho, Jung-Hoon;Lee, Chang-Hoon;Lee, Jin-Moo;Jang, Jun-Bock;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.6 no.1
    • /
    • pp.23-31
    • /
    • 2008
  • Objective: The purpose of this study is to identify relationship between the PWV and the temperature difference. Methods: When it comes to senile patients who suffer from cold limbs, there is need to see whether or not the patient's low temperature of the limbs is do to arteriosclerosis. The Pulse Wave Velocity(PWV) is a non-invasive method measuring the artery's rigidness. And the Digital Infrared Thermal Imaging(D.I.T.I) is a non-invasive method to see the body's thermal change. Research on the interrelationship of the artery's rigidness and body's thermal distribution was done by using these two tests. The subjects of this research were patients between the age 40~65 who have done both the D.I.T.I and PWV in March 2005~ September 2005. They had to have no history of diabetes, coronary illnesses or cerebrovascular diseases which are diseases that can effect the outcome of the PVW, nor history of spondylopathy or dermatosis which can effect the outcome of the D.I.T.I. Results: The results were as follows. 1. There was a significant interrelationship between the right wrist-ankle PWV and the temperature difference of the right wrist-palm. 2. There was a significant interrelationship between the left wrist-ankle PWV and the temperature difference of the left wrist-palm. 3. There was no significant interrelationship between the right wrist-ankle PWV and the temperature difference of the right thigh-dorsum of foot. 4. There was no significant interrelationship between the left wrist-ankle PWV and the temperature difference of the left thigh-dorsum of foot. 5. The right ABI showed no significant interrelationship between the temperature difference of the right wrist-palm and the right thigh-dorsum of foot. 6. The left ABI showed no significant interrelationship between the temperature difference of the left wrist-palm and the left thigh-dorsum of foot. Conclusion: The study shows that there was a significant interrelationship between wrist-ankle PWV and the temperature difference of wrist-palm.

  • PDF

Method of Biological Information Analysis Based-on Object Contextual (대상객체 맥락 기반 생체정보 분석방법)

  • Kim, Kyung-jun;Kim, Ju-yeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.41-43
    • /
    • 2022
  • In order to prevent and block infectious diseases caused by the recent COVID-19 pandemic, non-contact biometric information acquisition and analysis technology is attracting attention. The invasive and attached biometric information acquisition method accurately has the advantage of measuring biometric information, but has a risk of increasing contagious diseases due to the close contact. To solve these problems, the non-contact method of extracting biometric information such as human fingerprints, faces, iris, veins, voice, and signatures with automated devices is increasing in various industries as data processing speed increases and recognition accuracy increases. However, although the accuracy of the non-contact biometric data acquisition technology is improved, the non-contact method is greatly influenced by the surrounding environment of the object to be measured, which is resulting in distortion of measurement information and poor accuracy. In this paper, we propose a context-based bio-signal modeling technique for the interpretation of personalized information (image, signal, etc.) for bio-information analysis. Context-based biometric information modeling techniques present a model that considers contextual and user information in biometric information measurement in order to improve performance. The proposed model analyzes signal information based on the feature probability distribution through context-based signal analysis that can maximize the predicted value probability.

  • PDF

The Difference in Tear Film Stability between Normal and Dry Eyes by Wearing Clear and Circle Contact Lenses made of the Same Materials (동일 재질의 투명 및 써클콘택트렌즈 착용 시 정상안과 건성안의 눈물막 안정성 차이)

  • Lee, Sehee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.11-21
    • /
    • 2016
  • Purpose: The aim of this study was to analyze the difference in tear film stability according to the wearing time when wearing clear and circle soft contact lens(circle lens) made of same material. Methods: The clear and circle contact lenses of hilafilcon B and nelfilcon A materials were respectively applied on the subjects classified as normal and dry eyes depending on their tear volume, and their tear film stability was investigated by measuring the non-invasive tear film break-up times, lens centration and the first appearing area of tear breakup after 30 mins and 6 hrs of lens wearing. Results: Non-invasive tear film breakup time significantly reduced with increase of the wearing time for normal and dry eyes when wearing clear and circle contact lenses. The starting ratio of tear film break-up was higher at the peripheral area of clear and circle lenses in all two different materials, and higher at the peripheral area of dry eyes than normal eyes. Starting ratio of tear film break-up was higher at the peripheral area of nelfilcon A lenses compared with hilafilcon B lenses, however, its change with the increase of wearing time showed a different aspect. The number of tear film break-up per unit area when wearing circle lenses of nelfilcon A increased at the central area with the wearing time while its number was higher at the peripheral area when wearing circle lenses of hilafilcon B. The centration of clear lenses made of two materials was closer to pupil compared to circle lenses with the increase of wearing time, however, a larger decentration was shown in dry eyes compared with normal eyes. Conclusions: The research revealed that an effect on tear film stability may be changed by clear lenses as well as circle lenses with coloring process according to the increase of wearing time, and the factors affecting on tear film stability may also vary depending on lens materials. Thus, the appropriate lenses should be selected by the consideration of lens material as well as coloring method/dyes according to the wearers' habit such as daily wearing time and wearing period when trying to wear clear and circle lenses.

Basic Investigation for the Won-invasive Measurement of Blood Glucose Concentrations by Millimeter Waves (밀리미터파를 이용한 무혈 혈당 측정에 관한 기초 연구)

  • Kim Dong Kyun;Won Jong Hwa;Potapov Sergey N.;Meriakri Viacheslav V.;Chigryai Evgenii E.
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.1
    • /
    • pp.39-45
    • /
    • 2005
  • As a basic research for the development of a non-invasive blood glucose sensor using millimeter waves, we have presented a method for measuring the dielectric properties of high loss dielectrics, based on the reflection method, and investigated the variation of the dielectric properties of glucose-water and glucose -0.9% NaCl solutions in the 10~90 GHz range. In the proposed method, a minimal reflection condition is formed by placing a specially-chosen low-loss plane-parallel plate in front of a high-loss medium under test at a given frequency range. Using the minimal power reflection coefficient and the corresponding frequency at this condition, tile dielectric properties of the medium can be determined. The measured results on pure water have shown the adequacy of the proposed method. The measured results on glucose-water and glucose -0.9% NaCl solutions in the 10~90 GHz range showed that the variations of the dielectric properties of glucose solutions according to the change of their glucose concentration were maximum in the 30~45 GHz range. From these facts we concluded that the variation of about 3 mole/L in the glucose solutions must be distinguished With the measurement accuracies of ±0.1 dB and ±0.01 GHz.

Recent Progress in Computational Imaging Through Turbid Media (불규칙 매체를 통한 컴퓨테이셔널 이미징의 최근 연구 동향)

  • Jang, Hwanchol;Yoon, Changhyeong;Chung, Euiheon;Choi, Wonshik;Lee, Heung-No
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.12
    • /
    • pp.764-770
    • /
    • 2014
  • It is expected that the techniques of optical imaging through turbid media enables non-invasive imaging through human skin and biological tissues. In recent years, many researches have shown that imaging through turbid media can be made possible by measuring the transmission matrix (TM) of the turbid medium and utilizing it for image recovery. However, this TM based image recovery requires a huge amount of data acquisition and post signal processing of them. Very recently, there were new results that this problem of huge data acquisition and processing can be resolved by using the compressed sensing (CS) framework. CS is a relatively new signal acquisition and reconstruction framework which makes possible to recover the signal of interest correctly with significantly smaller number of signal measurements. In this paper, the TM-based image recovery in imaging through turbid media is reviewed and the recent progress made by using CS is introduced.

Implementation of the Potable Blood Pressure Measurement System Using Wireless Communication Technology and MAA Algorithm (무선통신기술과 MAA 알고리즘을 이용한 휴대형 혈압측정 시스템 구현)

  • Kim, Bo-Sung;Kim, Se-Jin;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.678-681
    • /
    • 2007
  • In this study, an implementation of a system for measuring more accurate blood pressure by non-invasive methods of oscillometric was performed. The system were composed of pressure control, signal measurement, blood pressure signal processing units and wireless sensor network parts. For verify the validity of the system, tests of characteristics evaluations for pressure measurement unit, extraction of characteristic ratios for blood pressure estimation, blood pressure tracking by oscillometric method were performed. A group of five adult male was selected for the clinical test of the implemented system. The results of the oscillometric method in comparison with auscultatory method are that the maximum ratios of PAD of average, systolic and diastolic arterial pressure are 1.38%, 1.63% and 2.97% with SEP of 5.00, 3.72 and 4.34.

  • PDF

Non-invasive Fdlow-up of Pulmonary artey by EBT Other Palliatrve Shunt Operatin (청색증형 선천성 심질환아의 고식적 수술 이후 EBT에 의한 폐혈관계이 비침습적 추적 검사)

  • 김민정;박영환;홍유선;이종균;최규옥;조범구
    • Journal of Chest Surgery
    • /
    • v.33 no.1
    • /
    • pp.7-19
    • /
    • 2000
  • Background :To assess the accuracy of Electron-Beam Tomography(EBT) in following evaluation of the pulmonary vascular system after a shunt operation in the cyanotic con-genital heart disease with pulmonary stenosis or pulmonary atresia. Material and Method : Sixteen patients(M:F=11:5) who received Blalock-Taussig(n=8) bidirectional cavo-pulmonary shunt(n=10) and unifocalization (n=2) were ncluded in the study. We evaluated the patency of the shunt the morphology of intrapericardial and hilar pulmonary arteries(PA) peripheral pulmonary vascularity by background lung attenuation and the abundance of arterial & venous collateral. Angiography(n=12) and echocardiography(n=20) were used as the gold standard for the comparison of EBT results. Result: EBT was consistent with angiogram/ echo in 100% of the evaluation for the patency of the shunt and in 12(by angiogram 100%) and 19(by echo 95%) for the detection the hypoplasia stenosis or interruption of central PA In measuring of PA EBT and angiogram corrlated(r=0.91) better than EBT-echo(r=0.88) or echo-angiogram(r=0.72) Abundant systemic arterial collateral were noted in 4 and venous collateral in 3 cases. In evaluating the peripheral pulmonary vascularity the homogenous and normal-ranged lung attenuation(m=6) decreased but homo-genous attenuation(n=1) segment-by-sgment heterogeneous attenuation(n=3) homogenous but asymmetrical attenuation(n=3) segment-by-segment heterogeneous attenuation(n=3) homogenous but asymmetrical attenuation(n=3) and venous congestion(n=2) were observed nd 12 of them were compatible with the blood flow pattern revealed by cardiac catheterization. Conclusion: EBT was accurate in the integrated evaluation of the pulmonary vascular system after the shunt including the patency of the shunt operaion the morphology and dimension of the central and hilar PAs and the loco-regional pulmonary flow in the lung parenchyma. It suggests the useful information about the need of secondary shunt operation the proper timing time for total repair and the need of interventional procedure prior to total repair.

  • PDF

The comparison between normal and cerebral infarction subject;using Transcranial Doppler (경두개 도플러(TCD)를 이용한 정상군과 뇌경색군의 상호비교연구)

  • Choi, Jae-Young;Lee, Dong-Won;Jeong, Sung-Hyun;Lee, Won-Chul
    • The Journal of Internal Korean Medicine
    • /
    • v.19 no.1
    • /
    • pp.157-167
    • /
    • 1998
  • Background and Purpose : Cerebrovascular reactivity(CVR) can be estimated by measuring the change of cerebral blood flow that occurs during vasostimulation. To estimate the cerebrovascular reactivity, we investigated the change of flow velocity of the middle cerebral artery(MCA) during hyperventilation and hypoventilation with the transcranial doppler. So we studied whether the CVR measured by this method could show a significant difference between the normal and the cerebral infarction subjects and whether the CVR may decrease with age in normal subjects. Methods : Using transcranial doppler, we measured the mean velocity(Vm), the pulsatility index(P.I.) at the resting state, the end of breath-holding and the end of hyperventilation in 36 normal and 10 cerebral infarction subjects, so we calculated the percentile change of mean velocity(%${\Delta}$Vm) and P.I.(%${\Delta}$P.I.) after the vasostimulation. We estimated the change of Vm, P.I., %${\Delta}$Vm and %${\Delta}$P.I. by the age group and compared those parameters between the age-matched normal control and cerebral infarction subjects. Results : The Vm in MCA significantly decreased with age(p<0.05), but there was no significant difference in Vm and P.I. between normal and cerebral infarction subjects. The %${\Delta}$Vm and %${\Delta}$P.I. in response to hyperventilation significantly decreased with age in MCA and there was significant difference in $%{\Delta}Vm$ of MCA after breath-holding between the normal and cerebral infarction subjects. Conclusion : The breath-holding and hyperventilation tests could be non-invasive and useful methods in estimation of the cerebrovascular reactivity and could be applied in the basal and follow-up evaluation of the cerebrovascular reserve of the ischemic stroke patients.

  • PDF