• Title/Summary/Keyword: non-invasive measuring

Search Result 86, Processing Time 0.028 seconds

Non-restraint Master Interface of Minimally Invasive Surgical Robot Using Hand Motion Capture (손동작 영상획득을 이용한 최소침습수술로봇 무구속 마스터 인터페이스)

  • Jang, Ik-Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.105-111
    • /
    • 2016
  • Introduction: Surgical robot is the alternative instrument that substitutes the difficult and precise surgical operation; should have intuitiveness operationally to transfer natural motions. There are limitations of hand motion derived from contacting mechanical handle in the surgical robot master interface such as mechanical singularity, isotropy, coupling problems. In this paper, we will confirm and verify the feasibility of intuitive Non-restraint master interface which tracking the hand motion using infra-red camera and only 3 reflective markers without the hardware handle for the surgical robot master interface. Materials & methods: We configured S/W and H/W system; arranged 6 infra-red cameras and attached 3 reflective markers on hands for measuring 3 dimensional coordinate then we find the 7 motions of grasp, yaw, pitch, roll, px, py, pz. And we connected Virtual-Master to the slave surgical robot(Laparobot) and observed the feasibility. To verify the result of motion, we compare the result of Non-restraint master and that of clinometer (and protractor) through measuring 0~180 degree, 10degree interval, 1000 samples and recorded standard deviation stands for error rate of the value. Results: We confirmed that the average angle values of Non-restraint master interface is accurately corresponds to the result of clinometer (and protractor) and have low error rates during motion. Investigation & Conclusion: In this paper, we confirmed the feasibility and accuracy of 3D Non-restraint master interface that can offer the intuitive motion of non-contact hardware handle. As a result, we can expect the high intuitiveness, dexterousness of surgical robot.

Near Infrared Reflectance Spectroscopy for Non-Invasive Measuring of Internal Quality of Apple Fruit

  • Sohn, Mi-Ryeong;Park, Woo-Churl;Cho, Rae-Kwang
    • Near Infrared Analysis
    • /
    • v.1 no.1
    • /
    • pp.27-30
    • /
    • 2000
  • In this study, we investigated the feasibility of non-destructive determination of internal quality factors of Fuji apple fruit using near infrared(NIR) reflectance spectroscopy and developed the calibration models. As the reference methods, refractometer, titration and texture analyzer for sugar content, acidity and firmness were used, respectively. Samples were scanned from 1100∼2500nm with InfraAlyzer 500C spectrometer and SESAME software was used for data analysis. A multiple linear regression(MLR) analysis was performed to develop the calibrations. The correlation coefficient(R) and standard error of prediction(SEP) were as follows; 0.91, 0.41$^{\circ}$Brix for sugar content, 0.90, 0.04% for acidity and 0.84, 0.094 kg for firmness, respectively. This study shows that NIR spectroscopy can be used to evaluate the sugar content acidity and firmness of apple fruit with acceptable accuracy.

Implementation of the Pulse Wave Measurement System Using Bipolar Biased Head on Mode of the Hall Sensor (홀 센서의 양극 바이어스 수직모드를 이용한 맥파측정시스템 구현)

  • Jin, Sang-Gon;Kim, Myoung-Nam
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.322-328
    • /
    • 2011
  • There are many ways to detect the heart rate non-invasively such as ECG, PPG, strain gauge, and pressure sensor. In this paper, the pulse wave measurement system using bipolar biased head on mode of the Hall sensor is proposed for measuring the radial artery pulse. TMS320F2812 was used to implement the proposed system and a portable wireless network(zig-bee) was used to show the experimental result. It was confirmed from experiment that the performance of the implemented system was more stable and faster than PPG sensor or piezoelectric film pressure sensor.

Development of a Simplified Eddy Current Tester Specialized in Non-Iron Metals

  • Zhang, XiaoDong;Tamura, Muneyoshi;Aoyama, Tomoo;Nagashima, Umpei
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.805-808
    • /
    • 2005
  • We constructed an eddy current tester as education programs of electronics and computers. The tester is designed based on frequency counting of square-waves digitally, where information of phase is lost, but which is very compact. Main controller of the tester is PIC16HC84A. Other parts, detection-coils, oscillators, and stabilizers are made by us. The tester is able to detect change of order(-5) in waves of 1MHz, whose function is kept in several minutes. The measurement period is 10-20 msec in the several minutes. Using the tester, we observed narrow gaps of copper/aluminum wires, and detected resistivity difference of 1.7 or 2.7 [$10^{-8}$ $ohm^{\ast}m$].

  • PDF

Accurate Heartbeat Frequency Extraction Method using UWB Impulse Radar

  • Cho, Hui-Sup;Park, Young-Jin
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.6 no.4
    • /
    • pp.246-252
    • /
    • 2017
  • Non-invasive and non-restrictive methods for measuring the physiological functions of the human body are useful for health care, security, and surveillance. In this paper, a new method that extracts human heartbeat information by utilizing ultra-wideband (UWB) impulse radar is proposed. The amplitude spectra of received radar pulses reflected from the human body are accumulated at specific time intervals, and chirp z-transform (CZT) is used to extract the heartbeat frequency from the amplitude spectra. The heartbeat frequency can be extracted with high-frequency resolution in the frequency band of the heartbeat of interest using CZT. Experimental results to verify the performance of the proposed method show that a highly accurate extraction of the heartbeat frequency is possible using this method.

Ultrasonography in periodontal diagnosis (악안면 초음파의 치주학적 활용)

  • Kim, Dae-Yeob;Lee, Jong-Bin;Pang, Eun-Kyoung
    • The Journal of the Korean dental association
    • /
    • v.55 no.11
    • /
    • pp.800-807
    • /
    • 2017
  • Ultrasonography is one of the most common diagnostic tools in medical imaging with non-invasive and non-radiation loaded characteristics. In the field of dentistry, especially for periodontology, high frequency ultrasonic device can be used for several purposes such as evaluating gingival thickness, identifying the level of alveolar bone, measuring the volume of mucosa of donor site for soft tissue graft and so on. According to recent studies, it was demonstrated that ultrasonic diagnosis had both accuracy and repeatability comparable to conventional diagnostic tools. However, improvement and development of intra-oral probe suitable for adpatation to gingiva and palatal mucosa, are considered as prerequisites for diffusion of ultrasonic diagnosis in periodontology.

  • PDF

Multi-Parameter Approach for Evaluation of Genomic Instability in the Polycystic Ovary Syndrome

  • Sekar, Nishu;Nair, Manju;Francis, Glory;Kongath, Parvathy Raj;Babu, Sandhya;Raja, Sudhakaran;Gopalakrishnan, Abilash Valsala
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.16
    • /
    • pp.7129-7138
    • /
    • 2015
  • Background: The polycystic ovary syndrome (PCOS), characterized by hyperandrogenism and chronic anovulation, is a common endocrine disorder in women. PCOS, which is associated with polycystic ovaries, hirsutism, obesity and insulin resistance, is a leading cause of female infertility. In this condition there is an imbalance in female sex hormones. All the sequelae symptoms of PCOS gradually lead to cancer in the course of time. It is heterogeneous disorder of unknown etiology so it is essential to find the exact cause. Materials and Methods: In this study both invasive and non-invasive techniques were employed to establish the etiology. Diagnosis was based on Rotterdam criteria (hyperandrogenism, ovulatory dysfunction, PCOM) and multiparameters using buccal samples and dermatoglypic analysis and cytogenetic study for 10 cases and four age and sex matched controls. Results: In clinical analysis we have observed the mean value of total testosterone level was 23.6nmol/L, total hirsutism score was from 12-24, facial acne was found in in 70% patients with 7-12 subcapsular follicular cysts, each measuring 2-8 mm in diameter. In dermatoglypic analysis we observed increases in mean value ($45.9^{\circ}$) of ATD angle when compared with control group and also found increased frequency (38%) of Ulnar loops on both fingers (UU), (18%) whorls on the right finger and Ulnar loop on left finger (WU) and (16%) arches on right and left fingers (AA) were observed in PCOS patients when compared with control subjects. Features which could be applied as markers for PCOS patients are the presence of Ulnar loops in middle and little fingers of right and left hand. The buccal micronucleus cytome assay in exfoliated buccal cells, we found decrease in frequency of micronuclei and significant increases in frequency of karyolysed nuclei in polycystic ovarian syndrome patients. Chromosome aberration analysis revealed a significant increase in frequency of chromosome aberrations (CAs) in PCOS patients when compared with controls. Conclusions: From this present work it can be concluded that non-invasive technique like dermatoglypics analysis and buccal micronucleus cytome assays with exfoliated buccal cell can also be effective biomarkers for PCOS, along with increased CAs in lymphocytes as a sign of genetic instability. There is a hypothesis that micronuclei and chromosomal aberrations could have a predictive value for cancer. From this present work it can be concluded to some extent that non-invasive technique like dermatoglypics and buccal cell analysis can also be effective for diagnosis.

Thermal imaging and computer vision technologies for the enhancement of pig husbandry: a review

  • Md Nasim Reza;Md Razob Ali;Samsuzzaman;Md Shaha Nur Kabir;Md Rejaul Karim;Shahriar Ahmed;Hyunjin Kyoung;Gookhwan Kim;Sun-Ok Chung
    • Journal of Animal Science and Technology
    • /
    • v.66 no.1
    • /
    • pp.31-56
    • /
    • 2024
  • Pig farming, a vital industry, necessitates proactive measures for early disease detection and crush symptom monitoring to ensure optimum pig health and safety. This review explores advanced thermal sensing technologies and computer vision-based thermal imaging techniques employed for pig disease and piglet crush symptom monitoring on pig farms. Infrared thermography (IRT) is a non-invasive and efficient technology for measuring pig body temperature, providing advantages such as non-destructive, long-distance, and high-sensitivity measurements. Unlike traditional methods, IRT offers a quick and labor-saving approach to acquiring physiological data impacted by environmental temperature, crucial for understanding pig body physiology and metabolism. IRT aids in early disease detection, respiratory health monitoring, and evaluating vaccination effectiveness. Challenges include body surface emissivity variations affecting measurement accuracy. Thermal imaging and deep learning algorithms are used for pig behavior recognition, with the dorsal plane effective for stress detection. Remote health monitoring through thermal imaging, deep learning, and wearable devices facilitates non-invasive assessment of pig health, minimizing medication use. Integration of advanced sensors, thermal imaging, and deep learning shows potential for disease detection and improvement in pig farming, but challenges and ethical considerations must be addressed for successful implementation. This review summarizes the state-of-the-art technologies used in the pig farming industry, including computer vision algorithms such as object detection, image segmentation, and deep learning techniques. It also discusses the benefits and limitations of IRT technology, providing an overview of the current research field. This study provides valuable insights for researchers and farmers regarding IRT application in pig production, highlighting notable approaches and the latest research findings in this field.

Implementation of Impedance Method to Estimate Blood Flow Variation with Cuff Pressure Change (커프 압력 조절에 따른 혈류량 변화 평가를 위한 임피던스법의 구현)

  • Jeong, Do-Un;Bae, Jin-Woo;Shon, Jung-Man;Yae, Su-Yung;Choi, Byeong-Cheol;Nam, Ki-Gon;Kim, Cheol-Han;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.462-472
    • /
    • 2004
  • In this study, we measured the blood flow on arm by non-invasive method and implemented a system to measure variation of the blood flow by estimating bio-electrical impedance and arterial pressure according to cuff pressure. The implemented system measured impedance variation according to pressure variation applied by artificial cuff pressure on the measuring position. The system consisted of pressure measuring part and impedance measuring part using 4-electrode method. Pressure measuring part was composed of semiconductor pressure sensor and electronic circuit for signal processing of sensor output signal. In addition, impedance measuring part was composed of constant current source circuit and lock-in amplifier for detecting impedance signal. We conducted experiments of impedance measuring part using standard resistance for performance evaluation of the implemented system. In addition we experimented to estimate variation of the blood flow by measuring impedances of the experimental group. We estimated ratio of the blood flow resistance using mean arterial pressure and variation of the blood flow. As a result the ratio of the blood flow resistance and variation of blood flow were in an inverse relationship with each other and the correlation coefficient was -0.96776.

Association of Uric Acid Levels with Arterial Stiffness in Korean Women and Non-smoking Men

  • Sull, Jae Woong;Koh, Eun Na;Cho, Sung Kweon;Bae, Hyung-Joon;Jee, Sun Ha
    • Biomedical Science Letters
    • /
    • v.23 no.3
    • /
    • pp.201-207
    • /
    • 2017
  • Measuring the pulse wave velocity (PWV) is a non-invasive method for evaluating the stiffness of the vessel wall. While previous studies investigated the association of uric acid level with arterial stiffness, most did not consider smoking status and obesity as covariates. The objective of this study was to investigate the relationship between uric acid levels and arterial stiffness, considering smoking status and obesity. We studied 3390 subjects (1940 males and 1450 females). Abnormal PWV was also defined as the highest quartile of values in the subjects. Data were analyzed using Pearson correlation, t-test, and multiple regression analysis. Approximately 41.9% of men and 3.7% of women were current smokers. Prevalence of hypertension was 11.4% in men and 7.0% in women. In women, hyperuricemia was associated with abnormal PWV (OR 1.58; 95% CI 1.03~2.43). Hyperuricemia was also associated with abnormal PWV (OR 2.37; 95% CI 1.01~5.59) in non- or light male smokers with normal blood pressure. This study suggests that uric acid is associated with arterial stiffness in women and non-smoking men.