Browse > Article
http://dx.doi.org/10.5369/JSST.2011.20.5.322

Implementation of the Pulse Wave Measurement System Using Bipolar Biased Head on Mode of the Hall Sensor  

Jin, Sang-Gon (Team of R&D, SOHA Electronic Co.)
Kim, Myoung-Nam (Dept. of Biomedical Eng., School of Medicine, Kyungpook National University)
Publication Information
Journal of Sensor Science and Technology / v.20, no.5, 2011 , pp. 322-328 More about this Journal
Abstract
There are many ways to detect the heart rate non-invasively such as ECG, PPG, strain gauge, and pressure sensor. In this paper, the pulse wave measurement system using bipolar biased head on mode of the Hall sensor is proposed for measuring the radial artery pulse. TMS320F2812 was used to implement the proposed system and a portable wireless network(zig-bee) was used to show the experimental result. It was confirmed from experiment that the performance of the implemented system was more stable and faster than PPG sensor or piezoelectric film pressure sensor.
Keywords
Hall Sensor; Bipolar Head on Mode; Radial Artery Pulse; Heart; Pressure Sensor; Non-Invasive;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 J. C. Back, Texs Instruments DSP TMS320F28XX CPU Hand Book, Sync Works, 2006.
2 G. H. Lee, Digital Signal Processor TMS320C6000 LABSTAR-CCS3.1(code composer studio)Start, chapter 3, pp. 2-16, 2002.
3 W. D. Peterson, D. A. Skramsted, and D. E. Glumac, "Piezo Film Pulse Sensor", Blood Pressure Monitor Project - Sub project, 2005.
4 미카미 나오키, C 언어에 의한 디지털 신호처리입문, 성안당, pp. 190-218, 2006.
5 J. H. McClellan, R. W. Schafer, and M. A. Yoder, DSP First, Prentice-Hall, pp. 132-174, 1998.
6 강필순, 현석환, 권영훈, 내 손으로 완성하는 LabVIEW, Infinity Books, 2008.
7 주왕기, 조화로운 삶, 행복한 삶을 위한 건강학, 라이브사이언스, 2004.
8 정병주, 유비쿼터스사회의 의료, 보건 비즈니스 트렌드, 한국전산원 정보화기획단, 제17호, 2006.
9 J. Y .Lee and J. C. Lin, "A microprocessor based noninvasive arterial pulse wave analyzer", IEEE Trans. Biomedical. Eng. vol. BME-32, no. 1, pp. 43-50, 1985.   DOI   ScienceOn
10 정동근, 김광년, 연규선, 최병철, 서덕준," 광전용적맥파를 이용한 요골동맥 맥파 검출", 생명과학지, 제13권, 제1호, pp. 42-46, 2003.   과학기술학회마을   DOI   ScienceOn
11 윤영준, 조정현, 정형민, 신학수, 소강섭," 압력 조절식 맥진 센서의 개발", 의공학회지, 제20권 제5호, pp. 567-572, 1999.   과학기술학회마을
12 윤창희, 이충순, 손대락," 홀 센서를 이용한 맥박측정", 한국자기학회 학술연구발표회 논문개요집, 제15권, 제1호, pp. 218-219, 2005.
13 손병기, 이정일, Sensor Engineering , 일진사, 2005.
14 Allegro Micro Systems. Inc., 3503 Ratiometric Linear Hall-effect Sensors Data Sheet, 2002.
15 Sensing and Control Honeywell Inc., Hall Effect Sensing and Application Hand Book, chapter 3, pp. 10-17, 2003.