• Title/Summary/Keyword: non-invasive detection

Search Result 144, Processing Time 0.027 seconds

Probe-based qPCR Assay for Rapid Detection of Predominant Candida glabrata Sequence Type in Korea

  • Bae, Jinyoung;Lee, Kyung Eun;Jin, Hyunwoo
    • Biomedical Science Letters
    • /
    • v.25 no.4
    • /
    • pp.407-416
    • /
    • 2019
  • Recent years have seen an increase in the incidence of candidiasis caused by non-albicans Candida (NAC) species. In fact, C. glabrata is now second only to C. albicans as the most common cause of invasive candidiasis. Therefore, the rapid genotyping specifically for C. glabrata is required for early diagnosis and treatment of candidiasis. A number of genotyping assays have been developed to differentiate C. glabrata sequence types (STs), but they have several limitations. In the previous study, multi-locus sequence typing (MLST) has performed with a total of 101 C. glabrata clinical isolates to analyze the prevalent C. glabrata STs in Korea. A total of 11 different C. glabrata STs were identified and, among them, ST-138 was the most commonly classified. Thus, a novel probe-based quantitative PCR (qPCR) assay was developed and evaluated for rapid and accurate identification of the predominant C. glabrata ST-138 in Korea. Two primer pairs and hybridization probe sets were designed for the amplification of internal transcribed spacer 1 (ITS1) region and TRP1 gene. Analytical sensitivity of the probe-based qPCR assay was 100 ng to 10 pg and 100 ng to 100 pg (per 1 μL), which target ITS1 region and TRP1 gene, respectively. This assay did not react with any other Candida species and bacteria except C. glabrata. Of the 101 clinical isolates, 99 cases (98%) were concordant with MLST results. This novel probe-based qPCR assay proved to be rapid, sensitive, highly specific, reproducible, and cost-effective than other genotyping assay for C. glabrata ST-138 identification.

Electroglottographic Measurements of Glottal Function in Voice according to Gender and Age

  • Ko, Do-Heung
    • Phonetics and Speech Sciences
    • /
    • v.3 no.1
    • /
    • pp.97-102
    • /
    • 2011
  • Electroglottography (EGG) is a common method for providing non-invasive measurements of glottal activity. EGG has been used in vocal pathology as a clinical or research tool to measure vocal fold contact. This paper presents the results of pitch, jitter, and closed quotient (CQ) measurements in electroglottographic signals of young (mean = 22.7 years) and elderly (mean = 74.3 years) male and female subjects. The sustained corner vowels /i/, /a/, and /u/ were measured at around 70 dB SPL since the most notable among EGG variables is the phonation intensity, which showed positive correlation with closed phase. The aim of this paper was to measure EGG data according to age and gender. In CQ, there was a significant difference between young and elderly female subjects while there was no significant difference between young and elderly male subjects. The mean value for young males was higher than that for elderly males while the mean value for young females was lower than that for elderly females. Thus, it can be said that in mean values, increased CQ was related to decreased age for females, while CQ decreased for males as the speaker's age decreased. Although the laryngeal degeneration due to increased age seems to occur to a lesser extent in females, the significant increase of CQ in elderly female voices could not be explained in terms of age-related physiological changes. In standard deviation of pitch and jitter, the mean values for young and elderly males were higher than that for young and elderly females. That is, male subjects showed higher in mean values of voice variables than female subjects. This result could be considered as a sign of vocal instability in males. It was suggested that these results may provide powerful insights into the control and regulation of normal phonation and into the detection and characterization of pathology.

  • PDF

Design of the Blood Pressure Measurement System Using the Inflatable Oscillometric Method (가압식 오실로메트릭 방법을 사용한 혈압측정 시스템의 설계)

  • 노동곤;이윤선;지정호;박성빈;이계형;김해관
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.281-286
    • /
    • 2003
  • Blood Pressure is one of the most fundamental Parameters which reflects physical conditions medically and the blood pressure measurement system using oscillometric method is a Non-Invasive Blood Pressure measurement device by measuring arterial Pressure through a cuff. In this paper. we designed a inflatable wrist blood pressure system which measures blood Pressure during the stepping inflation in the wrist cuff. The hardware system consists of a main power unit, a bladder in cuff unit, signal detection units, signal Processing units. a wireless data transmission unit, and a data display unit. We evaluated the reliability of this system by comparing and analyzing systolic. diastolic blood Pressure, and heart rate with other commercial blood Pressure measurement devices. Characteristic ratio values used to determine systolic and diastolic blood Pressure using MAA(Maximum Amplitude Algorithm) were 0.436 and 0.671 respectively.

Implementation and Estimation of the LUTS Diagnosis System for Home Health Care (홈 헬스케어에 적용 가능한 하부요로계 폐색 모니터링 시스템 구현 및 평가)

  • Jeong Do-Un;Chung Wan-Young;Jeon Gye-Rork
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.697-700
    • /
    • 2006
  • A sensor and measuring system were implemented to measure two signals that uroflow and urophonography during urination for diagnose the lower urinary tract symptom. The implemented system was composed of the uroflow sensor using the load-cell, the urophonography measurement sensor so as stethoscope type, pre-processing part for sensors signal detection, amplifier and filter, system control parts and PC measurement program. A simulator of the lower urinary system that is experimental equipment implemented for evaluate the implemented system. The two signals were measured using implemented system and analyzed these signal by means of time domain and frequency domain for extraction of the characteristic parameter the most influence of effect according to occlusion of the lower urinary system. Furthermore two signals were measured and analyzed with the subject of 5 healthy adult for clinical application possibility of the implemented system. As a result, the most influence bandwidth of effect according to occlusion of the lower urinary system is $253\sim282Hz$ of the urophonography signal.

  • PDF

Monoclonal Antibody-Based Dipstick Assay: A Reliable Field Applicable Technique for Diagnosis of Schistosoma mansoni Infection Using Human Serum and Urine Samples

  • Demerdash, Zeinab;Mohamed, Salwa;Hendawy, Mohamed;Rabia, Ibrahim;Attia, Mohy;Shaker, Zeinab;Diab, Tarek M.
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.1
    • /
    • pp.93-98
    • /
    • 2013
  • A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies.

Evaluation of circulating IGF-I and IGFBP-3 as biomarkers for tumors in dogs

  • Song, Doo-Won;Ro, Woong-Bin;Sur, Jung-Hyang;Seung, Byung-Joon;Kang, Hyun-Min;Kim, Jong-Won;Park, See-Hyoung;Park, Hee-Myung
    • Journal of Veterinary Science
    • /
    • v.22 no.6
    • /
    • pp.77.1-77.10
    • /
    • 2021
  • Background: Serum-based parameters are considered non-invasive biomarkers for cancer detection. In human studies, insulin-like growth factor-I and II (IGF-I and IGF-II) and insulin-like growth factor binding protein-3 (IGFBP-3) are useful as diagnostic or prognostic markers and potential therapeutic targets. Objectives: This study examined the diagnostic utility of circulating IGF-I, IGF-II, and IGFBP-3 levels in healthy dogs and dogs with tumors. Methods: The serum concentrations of these biomarkers in 86 dogs with tumors were compared with those in 30 healthy dogs using an enzyme-linked immunosorbent assay (ELISA). Results: The ELISA results showed no difference between healthy dogs and dogs with tumors in the serum IGF-II concentrations. On the other hand, there was a significant difference in the circulating IGF-I and IGFBP-3 levels between healthy dogs and dogs with tumors. The concentrations of serum IGF-I (median [interquartile range], 103.4 [59.5-175] ng/mL) in dogs with epithelial tumors were higher than those (58.4 ng/mL [43.5-79.9]) in healthy dogs. Thus, the concentrations of serum IGFBP-3 (43.4 ng/mL [33.2-57.2]) in dogs with malignant mesenchymal tumors were lower than those (60.8 ng/mL [47.6-70.5]) in healthy dogs. Conclusions: The serum IGF-I and IGFBP-3 levels can be used as diagnostic biomarkers in dogs with tumors.

Liquid Biopsy: Current Status and Future Perspective in Gastric Cancer and Helicobacter Infection (액체 생검(Liquid Biopsy): 위암 및 헬리코박터 감염증에서 적응과 전망)

  • Kang, Eun A;Han, Young Min;Park, Jong Min;Yoo, In Kyung;Hong, Sung Pyo;Hahm, Ki Baik
    • The Korean journal of helicobacter and upper gastrointestinal research
    • /
    • v.18 no.3
    • /
    • pp.150-156
    • /
    • 2018
  • Precision medicine stands for 4Ps - precise, preventive, participatory, and personal; in which "precision" is important because the current modern medicine starts from "trial and error," and "one does not fit all". Current targeted therapies for cancer have changed treatment approaches and led the precision medicine; however, clinical use of liquid biopsy, using blood or other liquid specimens to characterize circulating tumor cells (CTC) or tumor genes instead of biopsies of tumor tissues, still awaits availability of more information regarding non-invasive cancer detection and characterization, prediction of treatment response, monitoring the disease course and relapse possibilities, identification of mechanisms of drug resistance, and newer pathogenesis. In this review, we will introduce the basic concept of CTC, circulating cell free DNA, and exosomes and their possible application for gastric cancer relevant with Helicobacter pylori infection.

Role of enzyme immunoassay for the Detection of Helicobacter pylori Stool Antigen in Confirming Eradication After Quadruple Therapy in Children (소아에서 4제요법 후 enzyme immunoassay에 의한 Helicobacter pylori 대변 항원 검출법의 유용성에 대한 연구)

  • Yang, Hye Ran;Seo, Jeong Kee
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.2
    • /
    • pp.153-162
    • /
    • 2004
  • Purpose: The Helicobacter pylori stool antigen (HpSA) enzyme immunoassay is a non-invasive test for the diagnosis and monitoring of H. pylori infection. But, there are few validation studies on the HpSA test after eradication in children. The aim of this study was to assess the diagnostic accuracy of HpSA enzyme immunoassay for the detection of H. pylori to confirm eradication in children. Methods: From January 2001 to October 2003, 164 tests were performed in 146 children aged 1 to 17.5 years (mean $9.3{\pm}4.3$ years). H. pylori infection was confirmed by endoscopy-based tests (rapid urease test, histology, and culture). All H. pylori infected children were treated with quadruple regimens (Omeprazole, amoxicillin, metronidazole and bismuth subcitrate for 7 days). Stool specimens were collected from all patients for the HpSA enzyme immunoassay (Primier platinum HpSA). The results of HpSA tests were interpreted as positive for $OD{\geq}0.160$, unresolved for $$0.140{\leq_-}OD$$<0.160, and negative for OD<0.140 at 450 nm on spectrophotometer. Results: 1) One hundred thirty-one HpSA tests were performed before treatment. The result of HpSA enzyme immunoassay showed three false positive cases and one false negative case. The sensitivity, specificity, positive predictive value, and negative predictive value of HpSA enzyme immunoassay before treatment were 96.4%, 97.1%, 90%, and 99%, respectively. 2) Thirty-three HpSA enzyme immunoassay were performed at least 4 weeks after eradication therapy. The results of HpSA enzyme immunoassay showed two false positive cases and one false negative case. The sensitivity, specificity, positive predictive value, and negative predictive value after treatment were 88.9%, 91.7%, 80%, and 95.7%, respectively. Conclusion: Diagnostic accuracy of the HpSA enzyme immunoassay after eradication therapy was as high as that of the HpSA test before eradication therapy. The HpSA enzyme immunoassay was found to be a useful non-invasive method to confirm H. pylori eradication in children.

  • PDF

Diagnostic Values of Serum Levels of Pepsinogens and Gastrin-17 for Screening Gastritis and Gastric Cancer in a High Risk Area in Northern Iran

  • Nejadi-Kelarijani, Fatemeh;Roshandel, Gholamreza;Semnani, Shahryar;Ahmadi, Ali;Faghani, Behzad;Besharat, Sima;Akhavan-Tabib, Atefeh;Amiriani, Taghi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7433-7436
    • /
    • 2014
  • Background: Gastric cancer (GC) is the second cause of cancer related death in the world. It may develop by progression from its precancerous condition, called gastric atrophy (GA) due to gastritis. The aim of this study was to evaluate the accuracy of serum levels of pepsinogens (Pg) and gastrin-17 (G17) as non-invasive methods to discriminate GA or GC (GA/GC) patients. Materials and Methods: Subjects referred to gastrointestinal clinics of Golestan province of Iran during 2010 and 2011 were invited to participate. Serum levels of PgI, PgII and G17 were measured using a GastroPanel kit. Based on the pathological examination of endoscopic biopsy samples, subjects were classified into four groups: normal, non-atrophic gastritis, GA, and GC. Receiver operating curve (ROC) analysis was used to determine cut-off values. Indices of validity were calculated for serum markers. Results: Study groups were normal individuals (n=74), non-atrophic gastritis (n=90), GA (n=31) and GC patients (n=30). The best cut-off points for PgI, PgI/II ratio, G17 and HP were $80{\mu}g/L$, 10, 6 pmol/L, and 20 EIU, respectively. PgI could differentiate GA/GC with high accuracy (AUC=0.83; 95%CI: 0.76-0.89). The accuracy of a combination of PgI and PgI/II ratio for detecting GA/GC was also relatively high (AUC=0.78; 95%CI: 0.70-0.86). Conclusions: Our findings suggested PgI alone as well as a combination of PgI and PgI/II ratio are valid markers to differentiate GA/GC. Therefore, Pgs may be considered in conducting GC screening programs in high-risk areas.

Stereotactic Vacuum-Assisted Core Biopsy Results for Non-Palpable Breast Lesions

  • Agacayak, Filiz;Ozturk, Alper;Bozdogan, Atilla;Selamoglu, Derya;Alco, Gul;Ordu, Cetin;Pilanci, Kezban Nur;Killi, Refik;Ozmen, Vahit
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5171-5174
    • /
    • 2014
  • Background: The increase in breast cancer awareness and widespread use of mammographic screening has led to an increased detection of (non-palpable) breast cancers that cannot be discovered through physical examination. One of the methods used in the diagnosis of these cancers is vacuum-assisted core biopsy, which prevents a considerable number of patients from undergoing surgical procedures. The aim of this study was to present the results of stereotactic vacuum-assisted core biopsy for suspicious breast lesions. Materials and Methods: Files were retrospectively scanned and data on demographic, radiological and pathological findings were recorded for patients who underwent stereotactic vacuum-assisted core biopsy due to suspicious mammographic findings at the Interventional Radiology Centre of the Florence Nightingale Hospital between January 2010, and April 2013. Statistical analysis was carried out using Pearson's Chi-square, continuity correction, and Fisher's exact tests. Results: The mean age of the patients was 47 years (range: 36-70). Biopsies were performed due to BIRADS 3 lesions in 8 patients, BIRADS 4 lesions in 77 patients, and BIRADS 5 lesions in 3 patients. Mammography elucidated clusters of microcalcifications in 73 patients (83%) and focal lesions (asymmetrical density, distortion) in 15 patients (17%). In terms of complications, 1 patient had a hematoma, and 2 patients had ecchymoses (3/88; 3.3%). The histopathologic results revealed benign lesions in 63 patients (71.6%) and malignant lesions in 25 patients (28.4%). The mean duration of the procedure was 37 minutes (range: 18-55). Although all of the BIRADS 3 lesions were benign, 22 (28.6%) of the BIRADS 4 lesions and all of the BIRADS 5 lesions were malignant. Among the malignant cases, 80% were in situ, and 20% were invasive carcinomas. These patients underwent surgery. Conclusions: In cases where non-palpable breast lesions are considered to be suspicious in mammography scans, the vacuum-assisted core biopsy method provides an accurate histopathologic diagnosis thus preventing a significant number of patients undergoing unnecessary surgical procedures.