• 제목/요약/키워드: non-Horn

검색결과 54건 처리시간 0.027초

Understanding Prospective Teachers' Verbal Intervention through Teachers' Group Work Monitoring Routines

  • Pak, Byungeun
    • 한국수학교육학회지시리즈D:수학교육연구
    • /
    • 제23권4호
    • /
    • pp.219-233
    • /
    • 2020
  • Teachers' intervention in small groups is a research area that needs more research attention. Ehrenfeld and Horn (2020) identified teachers' group work monitoring routines that consist of four recurrent talk moves: 1) Initiation, 2) Entry, 3) Focus, and 4) Exit. To better understand prospective teachers' (PTs) intervention in small groups in mathematics classrooms, I investigated how PTs' intervention actions and purposes are related to the monitoring routines, particularly, in terms of Focus moves. I analyzed 26 PTs' responses to four written scenarios, each of which depicts interactions among students in a small group. I identified 1) types of PTs' math talk, 2) types of PTs' non-math talk, 3) types of intervention purposes, and 4) patterns of intervention actions and purposes by scenario. This study contributes to understanding PTs' intervention actions and purposes in mathematics instruction.

Genes Associated with Individual Variation of Electroacupuncture Anti-allodynic Effects in Rat

  • Hwang, Byung-Gil;Kim, Sun-Kwang;Han, Jae-Bok;Bae, Hyun-Su;Min, Byung-Il
    • 동의생리병리학회지
    • /
    • 제21권5호
    • /
    • pp.1285-1290
    • /
    • 2007
  • The present study aims to identify and characterize genes that cause differen genes between non-responders and responders to electroacupuncture (EA) on mechanical allodynia following peripheral nerve injury. Under sodium pentobarbital anesthesia, animals were subjected to unilateral transection of the superior caudal trunk at the level between S1 and S2 spinal nerves. EA stimulation (2Hz, 0.3 ms, 0.2-0.3 mA) was delivered to Zusanli (ST36) for 30 min 2 weeks after the surgery. The degree of mechanical allodynia was assessed quantitatively by touching the tail with von Frey hair (2.0 g) at 10 min intervals. The rats, which showed an EA-induced decrease of response frequencies under 10 %, were classified as non-responders and those displaying an EA-induced decrease of response frequencies 20 % or more were classified as responders. Results from oligonucleotide microarray, to which cDNAs from the spinal dorsal horn (DH) were applied, showed that hemoglobin beta chain complex and chondroitin sulfate proteoglycan-5 decreased and limbic system-associated membrane protein increased in the non-responder group, whereas calcium-independent alpha-Iatrotoxin receptor homolog-3 increased in the responder group. These results suggest that The functional abnormality of molecules regulating cell adhesion, intracellular signal transduction and cell differentiation in the spinal DH may be involved in the anti-allodynic effect of EA.

도축장의 생.해체검사를 통한 경산우 및 미경산우 감별법(I) (Discrimination of cows from heifers by antemortem and postmortem inspection in slaughter house)

  • 최임용;최태석;이달주;이해영;노창식;김규현;김은;권택부;이정학
    • 한국동물위생학회지
    • /
    • 제30권3호
    • /
    • pp.429-436
    • /
    • 2007
  • This study was performed to make helpful standard for discrimination of cows from heifers by uterine and ovarian section inspection. A total of 3,736 heifers and 249 cows were inspected from January to November 2006 in Karak Market Slaughter house. Firstly, it was obvious that non-corpus albicans were observed in almost heifers(3,597/3,736, 96.3%), but there were distinctive corpus albicans in all cows (249/249 100%). Secondly, another evident was that the length and diameter of the horn in uterus was below 30mm in 94.5% (3,267/3,736) heifers, but above 30mm in 90.4% (225/245) cows, and it was easy to distinguish between right and left horn by difference of size in 87.6% (218/249) cows. Thirdly the diameters of pelvic cavity was below 220mm in 96.8% (3,615/3,736) heifers, but was over 200mm in 85.1% (212/249) cows. Fourthly another difference was found in second sacrum union condition and 13th thoracic vertebral process's states. In case of heifers, it was distinctive five lines in each second sacrum, but it was non-distinctive or united in the same each lines of the sacrum in cows. Fifthly in the results of 13th thoracic vertebral colors, the ratio between red color and white color was 7 : 3 in heifers (3,385/3,736, 90.6%), but that was 2 : 8 in cows (199/249, 79.9%). Consequently, it was possible to use the method which discriminated cows from heifers by uterine and ovarian section inspection in large scaled field slaughter house.

젖소 동결수정란의 비외과적 이식에 있어서 수정란의 상태 및 이시조건이 수태율에 미치는 영향 (Effects of stage and quality of embryo, synchrony between donor and recipient and difficulty of transfer on pregnancy rate following non-surgical transfer of frozen-thawed bovine embryos)

  • 이은송;조충호;황우석
    • 대한수의학회지
    • /
    • 제29권3호
    • /
    • pp.361-371
    • /
    • 1989
  • This study was performed to investigate the effects of stage and quality of embryo, synchrony between donor and recipient and difficulty of transfer on pregnancy rate following non-surgical transfer of frozen-thawed bovine embryos. The results were as follows; 1. The overall pregnancy rate of this experiment was 63.4% and that of heifers(73.1%) was higher than that of cows(46.7%). 2. The pregnancy rates of recipients transferred with morulae, early blastocysts and blastocysts were 50.0%, 64.7% and 71. 4%, respectively. 3. The pregnancy rate of recipients transferred with good embryos(67.9%) was higher than that of recipients transferred with fair embryos(53.8%). 4. The pregnancy rates of embryos transferred to left and right uterine horn were 63.2% and 63.6%, respectively. 5. The pregnancy rate of recipients in estrous synchrony 0(76.2%) was higher than those of recipients in synchrony -1(55.6%) and +1(44.4%). 6. The pregnancy rate of recipients transferred with 2 embryos (71. 4%) was higher than that of recipients transferred with 1 embryo(61.8%). 7. The pregnancy rate of embryos transferred to uterine tip (72.0%) was higher than that of embryos transferred to uterine base(50.0%). 8. Ease of transfer was ranked to a scale of one to three on the basis of increasing difficulty. Transfers ranked as ease score 1 accounted for 77.8% of pregnancies and had higher pregnancy rate than ease score 2(66.7%) or 3(45.5%). 9. The pregnancy rate of recipients with excellent corpus luteum(CL) (70.0%) was higher than those of recipients with good CL(61.1%) or fair CL(61.5) %. In reviewing above results, it was considered that the factors such as embryo stage, embryo quality, estrous synchrony, corpus luteum quality, transfer site within uterus, recipient's parity and ease score affected the pregnancy rate after non-surgical transfer of frozen-thawed bovine embryos.

  • PDF

풍력발전기 부품소재의 마모결함 검출에 관한 연구 (A Study on Wear-type Defects of Part and Materials in Wind Power Generation)

  • 김성현;최승현;정나라;윤천한;김재열
    • 한국생산제조학회지
    • /
    • 제22권6호
    • /
    • pp.989-995
    • /
    • 2013
  • Unlike fossil-or nuclear fuel-based power generation, wind power generation using inexhaustible wind energy is a pollution-free, hazardless power generation method. In this study, ultrasound thermography is used for fabricating specimens of wind power generator bearings and wind power generator supplement flanges, and an optimally designed ultrasound horn and ultrasound excitation system are used for detecting damage to part materials of a wind power generation setup. In addition, thermal flow analysis and ultrasonic thermography imaging are comparatively analyzed for improving the detection reliability in terms of surface and internal defects of part materials and for verifying the developed system's field applicability and reliability.

마이크로스트립 패치 안테나를 이용한 박리 탐사 모델링 (Modeling of Debonding Detection Using Microstrip Patch Antenna)

  • 임홍철;이효석;우상균;송영철
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.35-39
    • /
    • 2006
  • With a growing concern about the state of infrastructure worldwide, the demand for the development of reliable nondestructive testing techniques (NDT) is ever increasing. Among possible NDT techniques. microwave method is proven to be effective in fast and non-contact inspection of concrete structures and inclusions inside concrete. It is also found that the microwave method has a potential in detecting the delamination between fiber reinforced polymer (FRP) plate and concrete. On the other hand, ultrasonic method can be another way to find the delamination. In this paper, the research work needed for the development of a reliable microwave method and ultrasonic method is studied in actual measurements of concrete specimens reinforced with FRP. Concrete specimens are made with FRP and artificial delamination inside. A microwave measurement system with horn antennas with high center frequency and broad frequency bandwidth are used to image inside concrete specimens for the detection of debonding. between concrete and FRP. Also, the equipment of ultrasonic method which is commercialized are used at the same condition. Both of the results are analyzed in comparison of each other. Microwave and ultrasonic methods have been used for the detection of debonding between concrete and fiber-reinforced plastic (FRP).

  • PDF

자연배란된 처녀우와 경산으로부터 비외과적으로 회수한 수정란의 발육단계에 관한 연구 (A Study on the Stage of Embryos Non-Surgically Recovered from Heifers and Cows in Natural Heat)

  • 정구민;김종국;임경순
    • 한국수정란이식학회지
    • /
    • 제4권1호
    • /
    • pp.41-45
    • /
    • 1989
  • Total thirty of flushing were attempted on day 4 to 15 of estrus cycle with S heifers and 9 cows by nonsurgical method. The flushed or recovered rate among flushings was 86.7% (26/30) or 88.5% (23/26), respectively. There was no difference in the recovered rate between heifers (85.7%,6/7) and cows (89.5%, 17119). The embryo was recovered on day 4 to 15 of estrus cycle from the donors in natural heat without any technical difficulties.The I2FG Foley catheter used for pubertal heifers had sometimes plug in it with uterine mucus during flushing of uterine horn. But the problem could be overcomed by pumping the catherter with fluthing solution or by changing the catheter. Three normal embryos were recovered from 3 pubertal (10-11 month old) heifers. The rate of normal and abnormal eggs was 60.9% (14123) and 39.1% (9/23), respectively. The abnormal eggs were on degenerating except one unfertilized egg and were mostly recovered from heifers or cows flushed consecutively during the estrus cycle. The developmental states of normal embryos were l6-cells on day 5, 32-cells on day 6, compacted-morula on day 7, early-to expanded-blastocyst on day 8-to 9, and hatching-to hatched-blastocyst on day 10 to 11 of estrus cycle. The stage of embryos on day 8 to 10 showed varities among donors. On day 8 to 9 of estrus cycle hatching-blas tocyst was recovered from some donors.

  • PDF

초음파를 이용한 초임계 이산화탄소 에멀젼내 Ni 전해도금 (Ni Electroplating in the Emulsions of Supercritical $CO_2$ Formed by Ultrasonar)

  • 고문성;주민수;박광헌;김홍두;김학원;한성호
    • 한국표면공학회지
    • /
    • 제37권6호
    • /
    • pp.344-349
    • /
    • 2004
  • Emulsions were formed through putting small quantity of nickel electroplating solution into supercritical carbon dioxide, and then electroplating in the $sc-CO_2$ emulsions was conducted. It is an environmental-friendly technology that can solve the treatment of a large quantity of toxic plating wastewater, which is a big problem in the existing wet plating, and also can reduce secondary waste generation fundamentally. Supercritical carbon dioxide emulsions enhanced by ultrasonic horn were formed by non-ionic surfactant and nickel solution. Plating condition within emulsions was set up as 120bar and $55^{\circ}C$ through measurement of electrical conductivity following the pressure change. Experiments were conducted respectively against supercritical carbon dioxide emulsions electroplating and general chemical electroplating, and then their results were compared and analyzed. As the experiment result utilizing emulsions, plating surface was formed very evenly even with a small quantity of electroplating solution, and fine particles were plated compactly without any pinhole or crack due to hydrogenation, which occurs in general electroplating. Used electroplating solution can be reused through recovery process. Therefore, this technology will be able to be applied as new clean technology in electro-plating.

서-나무 위축병(萎縮病)과 그 병원균(病原菌) (Notes on the Endothia Canker of Carpinus laxiflora and its Pathogenic Fungus, Endothia fluens Schw Shear et Stevens)

  • 김기청
    • 한국산림과학회지
    • /
    • 제6권1호
    • /
    • pp.6-10
    • /
    • 1967
  • In the present paper author investigated the symptom, pathogenic fungus and pathogenicity of Endothia canker of Carpinus laxiflora in Korea, and made clear the indistinct discription on its pathogen in the past. 1. The pathogen is identified as Endothia fluens (Schw.) Shear et Stevens. The discription is recorded as follows: Stromata cortical, erumpent, spherical or conical, outer yellowish-brown and inner yellowish, 0.5 to 2.5 mm in diameter; perithecia irregularly embeded in the bottom of stroma, 7 to 23 in a stroma usually spherical to elliptical or irregular, 235 to $370{\mu}$ in diameter, with black slender necks; each neck open the papilliate ostiole to the surface, about 250 to $400{\mu}$ in length; asci clavate or fusoid, colorless, 31.16 to 42.64 by 6.54 to $8.20{\mu}$ in size, average 37.02 by $6.84{\mu}$, with 8 ascospores in double line; ascospores elliptical, ovate or cylindrical, with rounded ends, hyaline, 1-septate, not constrict at the septum, 6.51 to 9.30 by 3.16 to $3.72{\mu}$, average 7.61 by $3.44{\mu}$ in size; pycnidia formed abundantly in stroma. spherical at first but later irregular large cavity by fussing each other; pycnospores oblong or rod-shaped, hyaline, non-septate, 3.8 by $1.9{\mu}$ in size; spore-horn formed abundantly under moist condition. 2. The pathogen is wound parasite invading the hosts through the wound. But after the infection is established, expanding the disease lesion is swiftly vigorus.

  • PDF

PIV를 이용한 초음파 진동에 의해 유도된 음향유동의 가시화 (Flow Visualization of Acoustic Streaming Induced by Ultrasonic Vibration Using Particle Imaging Velocimetry)

  • 노병국;권기정;이장연;이동렬
    • 한국소음진동공학회논문집
    • /
    • 제14권6호
    • /
    • pp.528-535
    • /
    • 2004
  • Ultrasonic Vibrator is designed to achieve the maximum vibration amplitude at 30 kHz by in-cluding a horn (diameter, 40 mm), mechanical vibration amplifier at the top of the ultrasonic vibrator in the system and making the complete system resonate. In addition, it is experimentally visualized by particle imaging velocimetry (PIV) that the acoustic streaming velocity in the gap is at maximum when the gap between the ultrasonic vibrator and stationary plate agrees with the multiples of half-wavelength of the ultrasonic wave. This fact results from the resonance of the sound wave and the theoretical analysis of that is also accomplished and verified by experiment. It is observed that the magnitude of the acoustic streaming dependent upon the gap between the ultrasonic vibrator and stationary plate possibly changes due to the measurement of the average velocity fields of the acoustic streaming induced by the ultrasonic vibration at resonance and non-resonance. There exists extremely small average velocity at non-resonant gaps while the relatively large average velocity exists at resonant gaps compared with non-resonant gaps. It also reveals that there should be larger axial turbulent intensity at the hub region of the vibrator and at the edge of it in the resonant gap where the air streaming velocity is maximized and the flow phenomena is conspicuous than that at the other region. Because the variation of the acoustic streaming velocity at resonant gap is more distinctive than that at non-resonant gap, shear stress increases more in the resonant gap and is also maximized at the center region of the vibrator except the local position of center (r〓0). At the non-resonant gap there should be low values of vorticity distribution, but in contrast to the non-resonant gap, high and negative values of it exist at the center region of the vibrator with respect to the radial direction and in the vicinity of the middle region with respect to the axial direction. Acoustic streaming is noise-free due to the ultrasonic vibration and maintenance-free because of the absence of moving parts. Moreover, the proposed method by acoustic streaming can be utilized to the nano and micro-electro mechanical systems as a driving mechanism in addition to the augmentation of the streaming velocity.