• 제목/요약/키워드: noise generator

검색결과 468건 처리시간 0.042초

750 kW 풍력발전기의 소음 실증 (Noise Test and Evaluation of a 750 kW Wind Turbine Generator)

  • 김석현;김태형
    • 한국소음진동공학회논문집
    • /
    • 제16권2호
    • /
    • pp.124-131
    • /
    • 2006
  • This study introduces an environmental noise evaluation procedure for wind turbines(W/T) and the evaluation result of a 750 kW wind turbine(W/T) system. Test and evaluation are performed according to the international standard IEC 61400-11 on J48 W/T which is under operation in Daekwanryung W/T test site. With the meteorological data and W/T operational data, noise data are monitored and analysed. An integrated monitoring system is constructed in the test site and is utilized for the evaluation. From the measured noise data, acoustic power level, directivity and tonality of the W/T are estimated under the wind speeds required fly the International standard. The purpose of the study is to establish an W/T noise evaluating system satisfying the international standard and to obtain noise data for home made 750 kW W/T.

A Design and Measurement of a Reference Signal Generator for a Radar System

  • Kim, Dong-Sik;Kim, Min-Chul;Lee, Su-Ho;Baik, Seung-Hun;Kwon, Ho-Sang;Jeong, Myung-Deuk
    • Journal of electromagnetic engineering and science
    • /
    • 제9권3호
    • /
    • pp.118-123
    • /
    • 2009
  • This paper discusses the design and fabrication of a reference signal generator for a naval radar system, including the vibration environment test. The transmit signals of the S-band radar system are synthesized by the reference signal and the phase noise must lower than - 130 dBc/Hz at a 10 kHz offset frequency. To achieve this specification, the phase noise of the reference signal needs to be less than -165 dBc/Hz at a 10 kHz offset. For achieving very low phase noise performance by the reference signal generator, the phase locked loop technique is applied with a 10 Hz loop bandwidth. Also, this reference signal generator has ${\pm}0.35\;ppb$ short-term stability to minimize instant phase errors and high vibration sensitivity against a ship's shaking, unbalanced rotating of antennas and so on.

선체 진동 특성 규명을 위한 기여도 분석 (Contribution Analysis to Identify the Source of Ship Hull Vibration)

  • 이준우;안세진;오준석;김태형;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제26권5호
    • /
    • pp.528-535
    • /
    • 2016
  • The vibration of a ship gives a significant effect on the noise radiated into the water. This paper focused on the vibration of ship hull due to the sub-generator located on the deck in the anchored condition. The contributions of the transfer paths between sub-generator and ship hull were analyzed using the TPA and the OTPA method. While the sub-generator was operation and the main engine was turned off, the vibrations were measured simultaneously at the 38 locations of the ship and the one hydrophone was arranged to measure the underwater radiated noise at the overside ship. The results of the transfer path by applying TPA and OTPA were compared and discussed. As a result of these methods, the top of stovepipe and valve are contributive. Reinforcing these structures is the most effective to reduce the vibration of ship hull.

Zwicker 파라미터를 이용한 수차발전기 소음의 음질분석 (Sound Quality Analysis of Water Turbing Generator Noise using Zwicker Parameter)

  • 국정훈;윤재현;김재수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.273-277
    • /
    • 2007
  • In case of the Hydraulic Turbine Dynamo operating for Waterpower Generation, it makes very huge and loud noises, and it influences bad effect physically as same as mentally to those people who are working inside of power plant, and brings the decline of an effective working efficiency. However, its evaluation method or measure about such noise reflects merely its physical attribute which is sensuous Loudness of the Noise itself, since the accumulation effect of Noise or the meaning connected with psychological response did not reflect, it is the actual state that a rational evaluation is unable to expect. Consequently, this Study has attempted to evaluate the Noise of Hydraulic Turbine Dynamo by analyzing the sound quality using Zwicker‘s Psychological Acoustic Parameter, after classification by its positions of the Noise occurring at Hydraulic Turbine Dynamo.

  • PDF

CE형 증기발생기 전열관의 행열 변화에 따른 유체유발진동 특성 (Characteristics of Flow-induced Vibration for CE Type Steam Generator Tube with Various Column and Row Number)

  • 유기완;조봉호;박치용;박수기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.927-932
    • /
    • 2002
  • The stability ratio and vibrational amplitude of each tube inside a steam generator have different values. We estimate the characteristics of flow-induced vibration for CE type steam generator with various column and row number of the tube. To obtain the thermal-hydraulic data and stability ratio we use the ATHOS3-MODI and PIAT-FEI/TE code respectively. It turns out that the steam generator has a bounded central zone with the distributed values of the stability ratio and the vibrational amplitude, and those values across the zone boundary become decreased.

  • PDF

CE형 증기발생기 튜브의 행열 변화에 따른 유체유발진동 특성 (Characteristics of Flow-induced Vibration for CE Type Steam Generator Tube with Various Column and Row Number)

  • Ryu, Ki-Wahn;Cho, Bong-Ho;Park, Chi-Yong;Park, Su-Ki
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.390.2-390
    • /
    • 2002
  • The stability ratio and vibrational amplitude of each tube inside a steam generator have different values. We estimate the characteristics of flow-induced vibration for CE type steam generator with various column and row number of the tube. To obtain the thermal-hydraulic data and stability ratio we use the ATHOS3 and PIAT-FEI/TE code respectively. It turns out that the steam generator has a bounded central zone which the distributed values of the stability ratio and the vibrational amplitude, and those values across the zone boundary become decreased.

  • PDF

디젤 발전기세트의 구조진동특성 연구 (Analysis and Prediction of Structural Vibration for Diesel Engine Generator Set)

  • 이수목;김관영;김원현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.948-954
    • /
    • 2002
  • The structural vibration of a diesel generator set was investigated through analyses and tests. FE modeling and normal mode analysis were performed and compared with measured results for both structure components and generator set assembly. The results of component analyses were fairly well coincident with measured results but those of assembled generator set showed more or less discrepancies. Discussions were given about the uncertainties for vibration characteristics of component structures and assembled running structures especially concerning their nonlinearities and damping effects. Detailed excitation analysis fellowed by forced response analysis was done from the engine and pressure data to compare with the actual measured vibration. As results the vibration prediction for frame structures of reciprocating internal combustion engine was confirmed reliable to some extent.

  • PDF

전력망에 연결된 디젤 발전기 세트의 비틀림 진동에 대한 기초 연구 (The Fundamental Study for Torsional Vibration of Diesel Generator Set connected Electric Power Grids)

  • 김효정;윤현우;로날드 디 바로;이돈출
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.294-297
    • /
    • 2014
  • A Shipboard power system consists of three or four diesel generator sets connected to a grid. In case of dual fuel diesel generator sets employed LNG ship as a prime mover, large amounts of electricity are required for electric propulsion, auxiliary machinery and accommodation facilities. The electrical connection between generators through a network, torsional vibration can lead power swings. In this paper, the influence on the network by the torsional vibration of diesel generator sets in grid operation were studied. The torsional vibration characteristics were investigated and analyzed through theoretical analysis and the vibration measurement and the results were presented.

  • PDF

박용엔진 배기소음기 개발 및 실선 적용 연구 (Design and Application of Exhaust Silencer for Ships)

  • 황성목;이보하;최충영;권혁
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.883-884
    • /
    • 2012
  • This study deals with design and application of silencer to reduce the exhaust noise, especially at the low frequency range below 200 Hz which is main contribution for the bridge wing noise and the external noise of ships. The designed silencer is composed of side branch resonator, Helmholtz resonator and absorbing material. The resonating frequencies of resonators are set to be the firing order frequencies of the generator engine. Based on the on-board measurement result, it is verified that the designed silencer can effectively reduce the exhaust noise of generator engine.

  • PDF

INTERPRETATION OF ELECTROCHEMICAL NOISE PARAMETERS AS INDICATORS OF INITIATION AND PROPAGATION OF SCC OF AN ALLOY 600 SG TUBE AT HIGH TEMPERATURES

  • Kim, Sung-Woo;Kim, Hong-Pyo
    • Nuclear Engineering and Technology
    • /
    • 제41권10호
    • /
    • pp.1315-1322
    • /
    • 2009
  • The present article is concerned with the application of an electrochemical noise (EN) monitoring technique to analyze the initiation and propagation of Pb-assisted stress corrosion cracking (SCC) of an Alloy 600 material in a simulated environment of a steam generator (SG) sludge pile at high temperatures. A typical increase of electrochemical current noise (ECN) and electrochemical potential noise (EPN) was frequently recorded from the EN measurement in a caustic solution with such impurities as PbO and CuO, indicating that there are localized corrosion events occurring. With the aid of microscopic and spectral analyses, the EN data involving information on such stochastic processes as uniform corrosion and the initiation and propagation of SCC, were analyzed based on a stochastic theory.