• Title/Summary/Keyword: noise generator

Search Result 467, Processing Time 0.027 seconds

A Study of AC Generator Noise Reduction Characteristics of Automobile Using Experimental Analysis (실험적 해석을 통한 차량용 교류발전기 소음 저감 특성 연구)

  • 김대원;신중호
    • Journal of KSNVE
    • /
    • v.8 no.1
    • /
    • pp.112-121
    • /
    • 1998
  • In this report, Experimental analysis for main factors and analyzing methods of electro-magnetic noise and no loading noise was conducted because of noise of AC generator, which is peripheral equipment by reduction of engine noise that would be the main cause of vehicle radiation noise. In addition, This is intended to suggest the noise reduction development basis of AC generator for actual fan and electro-magnetic noise by making-analyzing-testing it's sample.

  • PDF

The Design, Manufacture and Applications of a Gap Noise Generator for Testing the Characteristics of EMI from Transmission Lines (송전선로 EMI 특성 실험용 인공잡음발생장치 설계, 제작 및 적용)

  • Ju, Yun-Ro;Yang, Gwang-Ho;Myeong, Seong-Ho;Lee, Dong-Il;Sin, Gu-Yong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.1
    • /
    • pp.23-28
    • /
    • 2002
  • In order to survey the radiation characteristics of pure line noise of unwanted noise from overhead high voltage AC transmission lines, a disk type gap noise generator was manufactured. Disk size which decides capacitance between the noise generator and earth was selected through preliminary indoor experiments and analysis by using surface charge method. The capacitance is one of principal parameters related to the injection of a proper noise current into lines. On the basis of the capacitance obtained from calculation, 5mm of space was given to the gap of the noise generator to be installed o test line and an aluminum disk of 60cm radius was made. The field experiments were performed with the noise generator hung on the Kochang 765 kV full scale test line. As the results, the useful data which can be used to analysis the radiation characteristics of noise from transmission lines were obtained. Those are the directivity of antenna toward the line, lateral profiles, frequency spectra, height pattern and so on.

A Study on the Radiation Characteristics of Noise from HV AC Transmission Lines Using a Gap Noise Generator (인공잡음 발생장치를 이용한 초고압 시험선로의 잡음 방사특성 연구)

  • Shin, K.Y.;Lee, D.I.;Kim, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2041-2043
    • /
    • 1999
  • In order to investigate the radiation characteristics of unmixed line noise from overhead high voltage AC transmission lines, a gap noise generator was manufactured. Disk size which decides capacitance between the noise generator and earth was selected through preliminary indoor experiments and analysis by charge simulation method. The capacitance is one of principal parameters related to inject a proper noise current into lines. The field experiments were performed with the noise generator installed in Kochang 765 kV full scale test line. As the results, the useful data which can be used to analysis the radiation characteristics of noise from transmission lines was obtained. Those are lateral profiles the directivity of antenna toward lines, frequency spectra and so on.

  • PDF

Design of a Noise Generator for Tinnitus Retraining Therapy Using Auditory Model (청각 모델을 이용한 이명 재훈련 치료용 잡음 발생기의 설계)

  • 이규동;이윤정;김필운;조진호;장용민;이상흔;김명남
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.369-376
    • /
    • 2004
  • The tinnitus retraining therapy(TRT) is an effective method for treating tinnitus patients. This therapy use the white noise to stimulate auditory cells for a wide frequency range. In this paper, the small white noise generator using the thermal noise is proposed. And frequency response controller which can compensate the frequency response changed by the human outer and middle ear system is proposed. We can know that proposed system is more proper type on a purpose of the tinnitus retraining therapy comparing with conventional white noise generator.

A Case Study on Noise Effect Assessment and Countermeasure by Emergency Generators installed in an Exterior and interior Architecture (건축물 내외부에 설치된 비상용 발전기 소음영향 평가 및 대책방안 사례연구)

  • Yun, Dae-Jin;Choi, Jae-Sung;Kim, Chang-Yeol;Hong, Chang-Wan;Kim, Han-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.88-93
    • /
    • 2012
  • Recently data centers are being established or expanded according to IT industry development. A data center must be to install emergency generator. In case of the data center located the densely populated urban area, the operating noise of an emergency generator can be the cause of complains. In this case, in order to establish an effective and economical measure and quantitative and thorough review is needed by noise & vibration specialists. To achieve this, in this study, it is suggested noise reduction measure using noise measurement data and 3D noise analysis method.

  • PDF

Analysis of Randomness Characteristics of Hardware Noise Generator (하드웨어 잡음발생기의 랜덤 특성 분석)

  • Hong, Jin-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.263-267
    • /
    • 2011
  • This paper analyzed randomness characteristics of output data in generator based on hardware noise source. Also it is enhanced security randomness in the output stream of generator, which is applied on Laplacian filter. First it reviews criteria of randomness verification of output stream of hardware noise generator, and presents the enhanced results of output stream of generator, which is applied on Laplacian filter.

Analysis of High Vibration in Nuclear Turbine-Generator (원자력 발전소 터빈-발전기 고진동 저감에 대한 고찰)

  • Lee, Woo-Kwang;Ko, Woo-Sig;Kim, Kye-Yean;Koo, Jae-Raeyang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.46-50
    • /
    • 2007
  • The nuclear power plant's turbine-generator system had been suffered form some problems, such as high shaft vibration, generator casing crack, stator coil water leakage, high $H_2$ gas consumption rate. Those kinds of problems were related to high vibration. So nuclear plant decided to replace generator in order to reduce rotor high vibration and high thermal sensitivity. A series of effort to reduce turbine-generator vibration was carried out as followings, first of all, replacement of generator, analysis of turbine-generator vibration, LP B rotor shop balancing, improvement of LP B/Gen coupling run-out, improvement of Generator basement and field balancing. Finally the nuclear turbine-generator's shaft vibration was reduced below $60{\mu}m$ from over $200{\mu}m$ which is very excellent vibration in nuclear turbine-generator in Korea.

  • PDF

Analysis of Reducing Tonal Noise of the Gas Turbine Generator in order to Reduce Underwater Radiated Noise of a Naval Vessel (수중방사소음 저감을 위한 함정용 개스터빈 발전기의 순음 저감 분석)

  • Han, Hyung-Suk;Choi, Ki-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.155-162
    • /
    • 2009
  • Because the tonal sound of the underwater noise in a naval vessel can be identified from the sub-marine of the enemy, it should be reduced sufficiently. This kind of the noise usually comes from the structure-borne noise of the onboard machine and transfers to the sea through the hull of the ship. The vibration at the high frequency can be reduced sufficiently with damping material. In this paper, the damping coefficient of the steel plate with damping sheet is evaluated by experiment. Using these evaluated properties, the numerical analysis is performed in order to evaluate how much vibration of the generator can be reduced applying damping sheet on the encloser and base of it.

  • PDF

Noise Performance Test and Evaluation of a Wind Turbing Generator (풍력발전기 소음 성능 실증)

  • Kim, Seock-Hyun;Kim, Tae-Hyung;Park, Moo-Yeol;Chui, C.C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.241-245
    • /
    • 2005
  • This study introduces the wind turbine (W/T) noise evaluation procedure required in the international standard (IEC 61400-11) and monitoring system for the evaluation. Noise emission characteristics of a 750kW W/T generator is investigated. Test and evaluation are performed on J48 W/T model which is under operation in Daekwanryung Wind Test Site. With the noise signal, meteorological data and W/T operational data are monitored in real time by the integrated monitoring system using LabVIEW. From the measured noise data, acoustic power level and tonality of the W/T are estimated under the wind speeds required by the international standard.

  • PDF

Analysis of Reducing Tonal Noise of the Gas Turbine Generator in order to Reduce Underwater Radiated Noise of a Naval Vessel (수중방사소음 저감을 위한 함정용 개스터빈 발전기의 순음 저감 분석)

  • Han, Hyung-Suk;Choi, Ki-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.12
    • /
    • pp.1329-1337
    • /
    • 2009
  • Because the tonal sound of the underwater noise in a naval vessel can be identified from the sub-marine of the enemy, it should be reduced sufficiently. This kind of the noise usually comes from the structure-borne noise of the onboard machine and transfers to the sea through the hull of the ship. The vibration at the high frequency can be reduced sufficiently with damping material. In this paper, the damping coefficient of the steel plate with damping sheet is evaluated by experiment. Using these evaluated properties, the numerical analysis is performed in order to evaluate how much vibration of the generator can be reduced applying damping sheet on the encloser and base of it.