Survey and Evaluation for Exterior Noise of a High Rise Apartment in Seoul (서울시 초고층 아파트의 외부소음 측정과 평가)

  • Lee, Seon-Dong;Park, Yu-Ra;Lee, Sang-Woo;Yoo, Ho-Chun
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.95-101
    • /
    • 2004
  • As a part of acoustical design, it is often necessary to quantify aspects of an existing environment and to predict the result of adding an acoustical treatment. The most common sources of exterior noise, also termed as environmental noise,(or community noise) are traffic noise, air craft noise, industrial noise, etc. Transportation(air, road, and rail)noise is the dominant and most common source of noise exposure in residential neighborhoods, and the annoyance is its most consequential effect. The road traffic noise becomes aggravated due to the rapid increase of vehicles. It has a great effect on the dwelling environment. Therefore we investigate the characteristics and sources of the road traffic noise through grasping the status of the road traffic noise. In the present study, preceding studies investigated the noise level of urban areas in Seoul were reviewed and the noise level of urban areas in Seoul was measured at first, fifth, tenth, and nineteenth floor for two days of weekdays and two days of weekend.

A Study on the Proper Chest Exposure Conditions of Mobile Digital X-ray Unit by Exposure Index (Exposure Index를 이용한 이동형 디지털 X선 장치의 흉부촬영 적정노출조건에 관한 연구)

  • Kim, Jae-In;Lee, Yang-Sub;Jang, Dong-Soo;Jung, Min-Cheol;Bae, Seung-Ho;Lee, Kwan-Sub;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.139-144
    • /
    • 2011
  • The purpose of this report is recommending a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The experiment was performed with mobile digital X-ray unit and used a acrylic phantom for exposure index measurement. Exposure modality was kVp, mAs, SID. After every exposure, make a data sheet for characteristic curve of detector response. The equipment performed Mobile digital X-ray unit provide the user with values ralated to the incident exposure(air kerma)to the digital detector. They are showed as a logarithmic function shaped. As a result, DEI means a relative measure of exposure to the detector, as compared to the expected exposure for a particular anatomical view. Radiographic technique is the combination of factors used to exposure an anatomical part to produce a high quality radiography and technique charts used most commonly by radiographers to produce consistently exposure level which patient dose can be kept acceptably low.

  • PDF

Analysis of Building Facade Noise and Ground Noise in a Roadside Apartment Complex through Noise Mapping (노이즈맵핑을 활용한 도로변 아파트단지의 세대외부소음 및 옥외지면소음 특성 분석)

  • Shin, Hye-Kyung;Kim, Myung-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.4
    • /
    • pp.275-283
    • /
    • 2015
  • The aim of this study is to estimate the noise exposure of roadside apartment complex according to the characteristics of apartment complex. The facade noise level of residential buildings and the ground noise level inside apartment complexes were predicted and analyzed using noise mapping based on a computerized noise model. In addition, the correlation analysis between these noise levels and the characteristics of apartment complex such as traffic volume, building coverage, the number of adjacent roads, etc. was done in a total of 21 apartment complexes. The results showed that building facade noise level and ground noise level were positively correlated with traffic volume (correlation coefficient, r=0.616~0.623) and the number of adjacent roads (r=0.340~0.496). On the other hand, they were negatively correlated with building coverage (r=-0.413~-0.477) and complex area per the number of roads (r=-0.478~-0.615).

A Study on Variables of Aircraft Noise Survey in Korea (국내 항공기 소음 성가심 조사 설계 시 고려해야 할 변수에 관한 연구)

  • Lee, Ki-Jung;Lee, Kun;Chang, Seo-Il;Son, Jin-Hee;Lee, Yeon-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.742-749
    • /
    • 2006
  • For the purpose of finding if aircraft noise annoyance response is affected to variables when noise survey is performed, the questionnaire survey is conducted around the Gimpo International Airport in Seoul, Republic of Korea. This residential area is exposed to the aircraft noise and road traffic noise, simultaneously. Research areas are classified according to three different aircraft noise exposure levels expressed in WECPNL, under 75, between 75 and 80, and above 80 WECPNL, on aircraft noise map. The 7-step numerical magnitude with verbal category scales is used to measure the annoyance level. This surrey suggests that aircraft noise annoyance is not affected to an important extent by other noise sources (road traffic noise, community noise) and demographic variables (sex, age, education, occupation, dwelling type, length of residence). Aircraft noise annoyance would be related to complaint activity which is one of attitudinal variables.

  • PDF

Community Annoyance from Transportation Noise in Korea (한국인의 교통소음에 대한 불쾌감 연구)

  • Lee, Soo-Gab;Lim, Chang-Woo;Kim, Jae-Hwan;Hong, Ji-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.33-42
    • /
    • 2005
  • Studies on community annoyance caused by transportation noise exposure were carried out in fifty-one areas around Gimpo and Gimhae international airports, Gyungbu and Honam railway lines and east and riverside-northen motorway to accumulate social survey data and to assess the relationship between each transportation noise level and degree of annoyance in Korea. The measurements of transpotation noise were carried out using portable precision sound level meters (B&K type 2238 and LD 812) except in aircraft noise. Aircraft noise levels were measured automatically by airport noise monitoring system, B&K type 35n Social surveys were carried out to people living around noise measurement points. Questionnaires were only aggregated by face-to-face interviews using various questions concerned with demographic factors, degree of noise annoyance, interference with daily activities and health-related symptoms. The questions of noise annoyance were answered on an 11-point numerical scale. The respondents, from 18 to 70 years of age, were randomly selected and completed the questionnaire for themselves. The total number of respondents for the questionnaires was 1,839. The results showed that community annoyance of railway noise in Korea is similar to that in Japan, but is more severe than that in European countries.

  • PDF

Changes of Acoustic Reflex Thresholds and Speech-In-Noise Perception Using Personal Listening Device Under Subway Interior Noise (지하철 실내 소음 하에서 음향기기 사용에 따른 음향반사역치와 소음 속 어음인지 변화)

  • Han, Woojae;Chun, Hyungi;Ma, Sunmi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.2
    • /
    • pp.138-145
    • /
    • 2015
  • Although it is well-known that environmental noise can lead to hearing loss in individuals, the true extent of subway noise effects in the general population remains poorly understood. The purpose of the present study is to see changes of acoustic reflex thresholds and speech perception scores when passengers listen to music presented from their personal listening device in the subway. Forty subjects with normal hearing participated being divided into two groups, experimental and control groups. As a baseline, all subjects were measured by acoustic reflex thresholds in five test frequencies and Korean speech perception in noise (KSPIN) test at 0 and -5 dB SNR. In the experiment, the control group read newspaper or magazine in the subway noise, whereas the experimental group listened to music presented from their smartphone under the subway noise through speakers at 73.45 dBA for 60 min. After completing the experiment, two groups also conducted both acoustic reflex thresholds and KSPIN tests in the same condition as the baseline. The results showed that there was a significant difference of correct percent in speech-in-noise test between experimental and control groups and of that between two signal-to-noise ratios, which means the double noise exposure of 60 min might cause some degradation of speech perception when noise increases compared to only subway noise condition that was not statistically significant difference. We concluded that a risk of some degraded speech perception ability would be expected when passengers have a habit of listening to music in the subway noisy situation for a long duration.

Measurements of Whole-body Vibration Exposed from UH60-Helicopter and Their Analysis Results (UH60 헬기 조종사의 피폭진동 측정 및 평가 결과)

  • Cheung, Wan-Sup;Byeon, Joo-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.132-137
    • /
    • 2005
  • This paper addresses what amount of whole-body vibration is exposed to pilots of UH60 helicopters during flight. To measure the whole-body exposed from the feet and seat, the 12-axis vibration measurement system was used. It enables simultaneous measurement of vibration exposure from the body contact area of the feet, hip and back. The measured 12-axis vibration signals are exploited to the comfort level of UH60 helicopters during flight. It is shown that the evaluated ride value is close to $0.74{\sim}0.79m/s^2$ and that it is equivalent to the semantic scale of 'fairly uncomfortable'. To assess the health effects of whole-body vibration exposed to pilots of UH60 helicopters during their flight, the rms-based and VDV(vibration dose value)-based evaluation results of measured four-axis vibration signals are shown in this work. The fatigue-decreased proficiency limit, whose level is half of the exposure limit, is expected to come after the two-hour flight. The exposure limit is shown to reach after the 10-hour flight.

  • PDF

Changes of the Blood Pressure and the Pulse Rate of the Rat after the Noise Exposure (소음이 백서 혈압 및 맥박수에 미치는 영향)

  • Roh, Jae-Hoon;Shin, Dong-Chun;Cha, Bong-Suk;Moon, Young-Hahn
    • Journal of Preventive Medicine and Public Health
    • /
    • v.17 no.1
    • /
    • pp.239-243
    • /
    • 1984
  • The vascular reaction such as the indirect blood pressure and the pulse rate of the tail to the noise were examined in 8 naive Sprague-Dawley rats of both sexes. The sounds used in the experiment were 1KHz and 4 KHz, 95dB pure tone generated by Nagashima Audiometry. The indirect blood pressure and the pulse rate were checked at the rat tail by Polygraph at 5 minutes interval. The results were as follows: 1. The blood pressure and the pulse rate increased maximally 5 minutes after the exposure to both sounds. 2. The blood pressure and the pulse rate returned normal range within 20 minutes after the exposure of both sounds. 3. The increment of the blood pressure and the pulse rate was greater after the sound of 4KHz than after that of 1KHz, but it wasn't statistically significant.

  • PDF

Median Modified Wiener Filter for Noise Reduction in Computed Tomographic Image using Simulated Male Adult Human Phantom (시뮬레이션된 성인 남성 인체모형 팬텀을 이용한 전산화단층촬영 에서의 노이즈 제거를 위한 Median Modified Wiener 필터)

  • Ju, Sunguk;An, Byungheon;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.21-28
    • /
    • 2021
  • Computed tomography (CT) has the problem of having more radiation exposure compared to other radiographic apparatus. There is a low-dose imaging technique for reducing exposure, but it has a disadvantage of increasing noise in the image. To compensate for this, various noise reduction algorithms have been developed that improve image quality while reducing the exposure dose of patients, of which the median modified Wiener filter (MMWF) algorithm that can be effectively applied to CT devices with excellent time resolution has been presented. The purpose of this study is to optimize the mask size of MMWF algorithm and to see the excellence of noise reduction of MMWF algorithm for existing algorithms. After applying the MMWF algorithm with each mask sizes set from the MASH phantom abdominal images acquired using the MATLAB program, which includes Gaussian noise added, and compared the values of root mean square error (RMSE), peak signal-to-noise ratio (PSNR), coefficient correlation (CC), and universal image quality index (UQI). The results showed that RMSE value was the lowest and PSNR, CC and UQI values were the highest in the 5 x 5 mask size. In addition, comparing Gaussian filter, median filter, Wiener filter, and MMWF with RMSE, PSNR, CC, and UQI by applying the optimized mask size. As a result, the most improved RMSE, PSNR, CC, and UQI values were showed in MMWF algorithms.

Noise Exposure Levels for the Middle and the High School Students using Headsets in the PC Rooms (PC방(게임방)에서 헤드셋을 착용한 중•고등학생의 소음 노출수준)

  • Shin, Jaewoo;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.2
    • /
    • pp.135-143
    • /
    • 2005
  • This study was conducted to measure the exposure levels to noise for the middle and the high school students who worn headsets in the PC rooms. The noise levels from the headsets were measured with noise dosimeters, and the statistical relationships between the utilization pattern, user's views on the PC rooms and it's environment were analyzed for the selected PC rooms in the Ahnshan area. The results were as follows; 1. No significant difference was found in the number of uses and average time spent per day by education level and by sex of the users(p>0.05). 2. No statistical significant difference was found between the contents selected by education level of the users (p>0.05). The male participants overwhelmingly enjoyed the PC games (98.3 %) while females selected for listening music (75.0 %) with significant difference(P<0.05), followed by browsing internet and PC communications (70.0 %), PC game (66.7 %) and chatting (33.3 %). 3. The actual noise measurements of the headsets worn by the users of different sexes and educational backgrounds produced no differences(p>0.05), while a significant difference was found between genders (p<0.05). 4. For sound pressure level measurements, the weighted average(Lavg) of 84.5 dB(A) on the left headsets exceeded that of 79.8 dB(A) on the right headsets significantly(p<0.01) and the maximum value of 96.9 dB(A) on the left headsets exceeded the maximum value of 93.5 dB(A) on the right headsets(p<0.01). 5. The actual noise measurements of the headsets worn by the users of different sexes and educational backgrounds produced no differences(p>0.05), however, the contents selected by the users with different educational backgrounds were noted with significant difference(p<0.05) while no difference was found by gender(p>0.05).