• Title/Summary/Keyword: noise correlation

Search Result 1,265, Processing Time 0.028 seconds

Interior Noise Characteristics in Japanese, Korean and Chinese Subways

  • Soeta, Yoshiharu;Shimokura, Ryota;Jeon, Jin Yong;Lee, Pyoung Jik
    • International Journal of Railway
    • /
    • v.6 no.3
    • /
    • pp.120-124
    • /
    • 2013
  • The aim of this study was to clarify the characteristics of interior noise in Japanese, Korean, and Chinese subways. The octave-band noise levels, A-weighted equivalent continuous sound pressure level ($L_{Aeq}$) and parameters extracted from interaural cross-correlation/autocorrelation functions (ACF/IACFs) were analyzed to evaluate the noise inside running train cars quantitatively and qualitatively. The average $L_{Aeq}$ was 72-83 dBA. The IACF/ACF parameters of the noise showed variations in their values, suggesting they are affected by the characteristics of the trains running, wheel-rail interaction, and cross-section of the tunnels.

A study on the characteristics and actual conditions of operation noise and vibration of rope elevators in high-rise apartments (고층아파트 로프식 승강기의 운행 소음 및 진동 특성과 실태에 관한 연구)

  • Kang, Min-Woo;Oh, Yang-Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.1
    • /
    • pp.84-91
    • /
    • 2021
  • An Elevator is a very important equipment in high-rise apartments. The noise generated by an elevator is causing inconvenience to residents. However, there are no laws and regulations on elevator noise, and moreover it is not clear how to measure and evaluate elevator noise. For these problems, the first priority should be given to grasping the characteristics of noise and vibration generated during elevator operation. In this study, noise and vibration generated when operating a rope-type elevator in a high-rise apartment are divided according to the number of floors and the type of room, and the noise and vibration are simultaneously measured to understand the characteristics of noise and vibration. The correlation coefficient according to the experimental conditions was determined. As a result, it was found that elevator noise was mainly composed of components in the 125 Hz to 500 Hz band, and the correlation with vibration in the 125 Hz to 500 Hz band was also significant. For the top layer, it was confirmed that the correlation coefficient was very high at 0.8 level.

An Algorithm for Leak Locating using Coupled Vibration of Pipe-Water (배관-유체 연성진동을 이용한 누수지점 탐지알고리듬 개발연구)

  • Lee, Yeong-Seop;Yun, Dong-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.985-990
    • /
    • 2004
  • Leak noise is a good source to identify the exact location of a leak point of underground water pipelines. Water leak generates broadband noise from a leak location and can be propagated to both directions of water pipes. This sound propagation due to leak in water pipelines is not a non-dispersive wave any more because of the surrounding pipes and soil. However, the necessity of long-range detection of this leak location makes to identify low-frequency acoustic waves rather than high frequency ones. Acoustic wave propagation coupled with surrounding boundaries including cast iron pipes is theoretically analyzed and the wave velocity was confirmed with experiment. The leak locations were identified both by the acoustic emission (AE) method and the cross-correlation method. In a short-range distance, both the AE method and cross-correlation method are effective to detect leak position. However, the detection for a long-range distance required a lower frequency range accelerometers only because higher frequency waves were attenuated very quickly with the increase of propagation paths. Two algorithms for the cross-correlation function were suggested, and a long-range detection has been achieved at real underground water pipelines longer than 300m.

  • PDF

A Study on the Prediction & Transformation of Blasting Noise for Environmental Regulation Standard (발파소음의 예측기법과 환경규제 기준으로의 변환 연구)

  • 김남수;양형식
    • Explosives and Blasting
    • /
    • v.18 no.2
    • /
    • pp.14-22
    • /
    • 2000
  • The estimation of proper prediction method and the alteration of transformation method of environmental regulation standard were carried out by measuring blasting noise in construction field. The correlation of scaled distance with sound pressure level were better than with sound level, but it was proved to be difficult to control blasting noise because the correlation factor was too 1ow. three methods to transform sound pressure levee to sound level were examined. The method is the transformation by correlation equation of sound pressure level and sound level which are measured at the same time, and simplified transformation of A-weighting network corresponding to dominant frequency, and the transformation of sound pressure level by FFT. There were many errors to transform. The best effective method is the transformation using correlation equation of sound pressure level and sound level which are measured at the same time.

  • PDF

Efficient Correlation Noise Modeling and Performance Analysis for Distributed Video Coding System (분산 동영상 부호화 시스템을 위한 효과적인 상관 잡음 모델링 및 성능평가)

  • Moon, Hak-Soo;Lee, Chang-Woo;Lee, Seong-Won
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.6C
    • /
    • pp.368-375
    • /
    • 2011
  • In the distributed video coding system, the parity bits, which are generated in encoders, are used to reconstruct Wyner-Ziv frames. Since the original Wyner-Ziv frames are not known in decoders, the efficient correlation noise modeling for turbo or LDPC code is necessary. In this paper, an efficient correlation noise modeling method is proposed and the performance is analyzed. The method to estimate the quantization parameters for key frames, which are encoded using H.264 intraframe coding technique, is also proposed. The performance of the proposed system is evaluated by extensive computer simulations.

A Combined Pseudo-random Noise Signal Based Advanced Region Correlation Scheme for BOC(pn,n) Modulated GNSS Signals in Repeat-back Jamming Environment (재방송 재밍 환경에서 BOC(pn,n) GNSS 변조된 신호를 위한 CP-ARC 기법)

  • Yoo, Seungsoo;Yeom, Dong-Jin;Jee, Gyu-In;Kim, Sun Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.11
    • /
    • pp.977-983
    • /
    • 2016
  • This paper proposes a novel code-tracking scheme to track the fine code synchronization for BOC (pn,n)-modulated global navigation satellite system signals in a repeat-back jamming environment. The correlation function of BOC (pn,n)-modulated signals has several peaks. The correlation function in the advanced offset region remains almost unchanged due to the repeat-back signals being received later than a line-of-sight signal in the same multipath signal receiving case. Additionally, the combined pseudo-random noise signal can be treated as repeat-back jamming signals, like multipath signals. In this paper, we propose a novel code-tracking scheme utilizing the advantages of using a combined pseudo-random noise signal in the advanced offset region and verify its performance through simulation.

Time Delay Estimation for the Identification of Leak Location (시간지연 추정을 통한 누수위치 식별 연구)

  • Lee, Young-Sup;Yoon, Dong-Jin;Kim, Chi-Yup
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.327-332
    • /
    • 2004
  • Leak noise is a good source to identify the exact location of a leak point of underground water pipelines. Water leak generates broadband noise from a leak location and can be propagated to both directions of water pipes. This sound propagation due to leak in water pipelines is not a non-dispersive wave any more because of the surrounding pipes and soil. However, the necessity of long-range detection of this leak location makes to identify low-frequency acoustic waves rather than high frequency ones. Acoustic wave propagation coupled with surrounding boundaries including cast iron pipes is theoretically analyzed and the wave velocity was confirmed with experiment. The leak locations were identified both by the acoustic emission (AE) method and the cross-correlation method. In a short-range distance, both the AE method and cross-correlation method are effective to detect leak position. However, the detection for a long-range distance required a lower frequency range accelerometers only because higher frequency waves were attenuated very quickly with the increase of propagation paths. Two algorithms for the cross-correlation function were suggested, and a long-range detection has been achieved at real underground water pipelines longer than loom.

  • PDF

An anti-noise real-time cross-correlation method for bolted joint monitoring using piezoceramic transducers

  • Ruan, Jiabiao;Zhang, Zhimin;Wang, Tao;Li, Yourong;Song, Gangbing
    • Smart Structures and Systems
    • /
    • v.16 no.2
    • /
    • pp.281-294
    • /
    • 2015
  • Bolted joint connection is the most commonly used connection element in structures and devices. The loosening due to external dynamic loads cannot be observed and measured easily and may cause catastrophic loss especially in an extreme requirement and/or environment. In this paper, an innovative Real-time Cross-Correlation Method (RCCM) for monitoring of the bolted joint loosening was proposed. We apply time reversal process on stress wave propagation to obtain correlation signal. The correlation signal's peak amplitude represents the cross-correlation between the loosening state and the baseline working state; therefore, it can detect the state of loosening. Since the bolt states are uncorrelated with noise, the peak amplitude will not be affected by noise and disturbance while it increases SNR level and increases the measured signals' reliability. The correlation process is carried out online through physical wave propagation without any other post offline complicated analyses and calculations. We implemented the proposed RCCM on a single bolt/nut joint experimental device to quantitatively detect the loosening states successfully. After that we implemented the proposed method on a real large structure (reaction wall) with multiple bolted joint connections. Loosening indexes were built for both experiments to indicate the loosening states. Finally, we demonstrated the proposed method's great anti-noise and/or disturbance ability. In the instrumentation, we simply mounted Lead Zirconium Titanate (PZT) patches on the device/structure surface without any modifications of the bolted connection. The low-cost PZTs used as actuators and sensors for active sensing are easily extended to a sensing network for large scale bolted joint network monitoring.

An Experimental Study on the Subjective Response for Water Supply and Drain Installations in Apartment Bathroom (공동주택 급배수 설비소음의 주관반응에 관한 실험적 연구)

  • Lee, Tai-Gang;Ko, Kwang-Pil;Kim, Hang;Song, Guk-Gon;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.6
    • /
    • pp.663-673
    • /
    • 2008
  • The purpose of this study is to analyze the appropriate evaluation method for the water supply and drain noise of bathroom in apartment and to propose some fundamental idea on its regulation. For this reason, it was studied the acoustical characteristics of water supply and drain noise as modifying the water supply pressure for the washbasins and toilet stools and suggested the optimum evaluation method through psychoacoustic test. As a result of investigation of the levels by evaluating the adjectives and noise sources with 7-step criteria corresponding to each level of plumbing noises and analysis of the correlation between physical evaluation values by comparing the criteria, dB(A), N, and NC, with subject's response, determination coefficient($R^2$) was shown to be relatively fair or higher ranged from 0.65 to 0.92. It is shown that 'Harsh', 'Nervous', 'Unpleasant', 'Distasteful', and 'Repellent' as a second factor are to be appropriate to evaluate plumbing noise. Above these results could be used in basic data establishing KS(Korean Standard) for evaluation and rating procedure and measures reducing these noise.

Analysis on the Correlation between Noise and Urban Forests (도시림과 소음의 상호 연관관계 분석)

  • Ahn, Byeong-Il;Yang, Jun-Seok;Kim, Eui-Gyeong
    • Journal of agriculture & life science
    • /
    • v.43 no.5
    • /
    • pp.47-55
    • /
    • 2009
  • This study analyzes the correlation between noise and the size of urban forests. Under the assumption that the main cause of the noise m the city is the population density, the size of urban forests per capita and the ratio of urban forests with respect to the size of urban per 100 thousand persons are used for the calculation of correlations with noise. The results of the calculations of Pearson's and Spearman's correlation coefficients indicate that the increase in the size of urban forests has a significant effects in reducing the day-time as well as night-time noise for most regions in the cities. The size of urban forests within public parks has a significantly negative correlation with the noise. However, calculated correlation coefficients imply the increase in the size of total urban forests is more effective in reducing the noise than the increase in the urban forests in public parks.