An anti-noise real-time cross-correlation method for bolted joint monitoring using piezoceramic transducers  

Ruan, Jiabiao (Department of Mechanical Engineering, University of Houston)
Zhang, Zhimin (Institute of Applied Physics, University of Electronic Science and Technology of China)
Wang, Tao (College of Mechanical Engineering and Automation, Wuhan University of Science and Technology)
Li, Yourong (College of Mechanical Engineering and Automation, Wuhan University of Science and Technology)
Song, Gangbing (Department of Mechanical Engineering, University of Houston)
Publication Information
Smart Structures and Systems / v.16, no.2, 2015 , pp. 281-294 More about this Journal
Abstract
Bolted joint connection is the most commonly used connection element in structures and devices. The loosening due to external dynamic loads cannot be observed and measured easily and may cause catastrophic loss especially in an extreme requirement and/or environment. In this paper, an innovative Real-time Cross-Correlation Method (RCCM) for monitoring of the bolted joint loosening was proposed. We apply time reversal process on stress wave propagation to obtain correlation signal. The correlation signal's peak amplitude represents the cross-correlation between the loosening state and the baseline working state; therefore, it can detect the state of loosening. Since the bolt states are uncorrelated with noise, the peak amplitude will not be affected by noise and disturbance while it increases SNR level and increases the measured signals' reliability. The correlation process is carried out online through physical wave propagation without any other post offline complicated analyses and calculations. We implemented the proposed RCCM on a single bolt/nut joint experimental device to quantitatively detect the loosening states successfully. After that we implemented the proposed method on a real large structure (reaction wall) with multiple bolted joint connections. Loosening indexes were built for both experiments to indicate the loosening states. Finally, we demonstrated the proposed method's great anti-noise and/or disturbance ability. In the instrumentation, we simply mounted Lead Zirconium Titanate (PZT) patches on the device/structure surface without any modifications of the bolted connection. The low-cost PZTs used as actuators and sensors for active sensing are easily extended to a sensing network for large scale bolted joint network monitoring.
Keywords
Real-time Cross Correlation Method (RCCM); bolted joint loosening detection; PZT; time reversal; stress wave propagation; active sensing;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Amerini, F. and Meo, M. (2011), "Structural health monitoring of bolted joints using linear and nonlinear acoustic/ultrasound methods", Struct. Health Monit., 10(6), 659-672.   DOI
2 Amerini, F., Barbieri, E., Meo, M. and Polimeno, U. (2010), "Detecting loosening/tightening of clamped structures using nonlinear vibration techniques", Smart Mater. Struct., 19(8), 085013.   DOI
3 Argatov, I. and Sevostianov, I. (2010), "Health monitoring of bolted joints via electrical conductivity measurements", Int. J. Eng. Sci., 48(10), 874-887.   DOI
4 Ayres, J.W., Lalande, F., Chaudhry, Z. and Rogers, C.A. (1998), "Qualitative impedance-based health monitoring of civil infrastructures", Smart Mater. Struct., 7(5), 599.   DOI
5 Caccese, V., Mewer, R. and Vel, S.S. (2004), "Detection of bolt load loss in hybrid composite/metal bolted connections", Eng. Struct., 26(7), 895-906.   DOI
6 Giurgiutiu, V., Reynolds, A. and Rogers, C.A. (1999), "Experimental investigation of E/M impedance health monitoring for spot-welded structural joints", J. Intel. Mat. Syst. Str., 10(10), 802-812.   DOI
7 Heyman, J.S. (1997), "A CW ultrasonic bolt-strain monitor", Experimental Mech., 17(5), 183-187.   DOI
8 Huda, F., Kajiwara, I., Hosoya, N. and Kawamura, S. (2013), "Bolted joint loosening detection by using laser excitation", SPIE Smart Structures and Materials+ Nondestructive Evaluation and Health Monitoring, 869531-869531.
9 Jhang, K.Y., Quan, H.H., Ha, J. and Kim, N.Y. (2006), "Estimation of clamping force in high-tension bolts through ultrasonic velocity measurement", Ultrasonics , 44, 1339-1342.   DOI
10 Johnson, G.C., Holt, A.C. and Cunningham, B. (1986), "An ultrasonic method for determining axial stress in bolts", J. Test. Eval., 14(5), 253-259.   DOI
11 Marioli, D., Narduzzi, C., Offelli, C., Petri, D., Sardini, E. and Taroni, A. (1991), "Digital time of flight measurement for ultrasonic sensors", Proceedings of the Instrumentation and Measurement Technology Conference, Atlanta, May
12 Nakahara, T., Yamamoto, M., Ohya, Y., and Okuma, M. (2004), Bolt loosening detection using vibration characteristics of thin plate with piezoelectric elements, Smart Structures and Materials (pp. 667-678), July.
13 Peairs, D.M., Park, G. and Inman, D.J. (2004), "Improving accessibility of the impedance-based structural health monitoring method", J. Intel. Mat. Syst. Str., 15(2), 129-139.   DOI
14 Park, G., Sohn, H., Farrar, C.R. and Inman, D.J. (2003), "Overview of piezoelectric impedance-based health monitoring and path forward", Shock Vib. Digest, 35(6), 451-464.   DOI
15 Park, S., Anton, S.R., Kim, J.K., Inman, D.J. and Ha, D.S. (2010), "Instantaneous baseline structural damage detection using a miniaturized piezoelectric guided waves system", KSCE J. Civil Eng., 14(6), 889-895.   DOI   ScienceOn
16 Park, S., Yun, C.B., Roh, Y. and Lee, J.J. (2006), "PZT-based active damage detection techniques for steel bridge components", Smart Mater. Struct,, 15(4), 957.   DOI
17 Ritdumrongkul, S., Abe, M., Fujino, Y. and Miyashita, T. (2004), "Quantitative health monitoring of bolted joints using a piezoceramic actuator.sensor", Smart Mater. Struct., 13(1), 20.   DOI
18 Song, S., Moran, K.P. and Lee, S. (1993), "Thermal and electrical resistances of bolted joints between plates of unequal thickness", Proceedings of the Semiconductor Thermal Measurement and Management Symposium, Austin, Feb.
19 Tadolini, S.C. (1990), Evaluation of ultrasonic measurement systems for bolt load determinations, US Department of the Interior, Bureau of Mines.
20 Todd, M., Nichols, J., Nichols, C. and Virgin, L. (2004), "An assessment of modal property effectiveness in detecting bolted joint degradation: theory and experiment", J. Sound Vib., 275, 1113-1126.   DOI
21 Wang, T., Song, G., Wang, Z. and Li, Y. (2013), "Proof-of-concept study of monitoring bolt connection status using a piezoelectric based active sensing method", Smart Mater. Struct., 22(8), 087001.   DOI
22 Yu, L. and Giurgiutiu, V. (2005), "Advanced signal processing for enhanced damage detection with piezoelectric wafer active sensors", Smart Struct. Syst., 1(2), 185-215.   DOI
23 Yasui, H. and Kawashima, K. (2000), "Acoustoelastic measurement of bolt axial load with velocity ratio method", Proceedings of the 15th World Conf. on Non-Destructive Testing, Rome, Oct.