• 제목/요약/키워드: noise analysis

검색결과 9,285건 처리시간 0.044초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

3.0 Tesla 자기공명영상시스템에서 고 해상도 나선주사영상 (High-resolution Spiral-scan Imaging at 3 Tesla MRI)

  • 김판기;임종우;강승원;조상흠;전수열;임헌진;박호종;오승준;이흥규;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • 제10권2호
    • /
    • pp.108-116
    • /
    • 2006
  • 목적 : 3.0 Tesla 고 자장에서 고 해상도 나선주사영상을 수행하였다. 나선주사영상은 초고속 영상기법의 하나로서, Echo Planar Imaging(EPI)에 비하여 eddy current 가 작게 발생하고, 경사자계 파형의 기울기가 완만하여 상대적으로 낮은 slew rate 를 가진 경사자계시스템으로 구현이 가능한 장점이 있다. 또한 고 자장 영상에서 고속스핀에코(Fast Spin Echo: FSE) 등의 rf 에코 기반의 고속영상방법에서 심각하게 대두되는 SAR 문제가 근원적으로 발생하지 않는 장점이 있어 고 자장에서의 초고속영상방법으로 주목을 받고 있다. 본 연구에서는 3.0 Tesla 에서 나선주사방식으로 고 해상도 영상을 얻어 고 자장 MRI에서 나선주사영상기법의 다양한 응용 가능성을 살펴보고자 한다. 대상 및 방법 : 3 Tesla 전신 자기 공명 영상 시스템에서 다양한 해상도의 나선주사영상 방법을 개발하였다. 고차(higher-order) shimming 을 통하여 영상의 화질을 개선하였고, 해상도에 맞게 interleaves 수를 조절하였다. 스핀에코 와 gradient에코 기반 나선주사영상방법을 구현하였고, 에코 time 과 repetition time, rf 회전 각도를 조절하여 영상의 대조도(contrast)와 신호대잡음비를 조절하였다. 결과 : 3 Tesla 전신 자기 공명 영상 시스템에서 나선 주사 방법을 이용하여 다양한 해상도의 영상을 얻었다. 고 자장에서 주 자장의 불균일도(inhomogeneity) 의 절대 크기가 커지기 때문에 이를 줄이기 위한 shimming 이 더욱 중요해진다. 한번의 스캔으로 axial, sagittal, coronal 방향의 불균일도 map을 구하여 spherical harmonics 분석으로 고차 shimming을 하였다. 팬텀과 in-vivo 두부 영상에서 single shot 나선주사 영상으로 $100{\times}100$ 정도의 영상과 6-12 정도의 interleaves 를 적용하여 $256{\times}256$ 의 고 해상도 영상을 얻을 수 있었다. 결론 : 신호대잡음비의 향상과 스펙트럼의 분리, 뇌기능영상에서 BOLD 효과 향상 등으로 고자장 영상에 대한 관심이 높아지고 있다. 그러나 고 자장 영상에서의 rf field 에 의한 SAR 증가는 중요한 제한 요소로 부각되고 있다. 나선주사영상은 SAR 문제가 근원적으로 발생하지 않고, EPI에 비하여 하드웨어 요구 조건이 낮아 고 자장에서의 고속영상방법으로 적합하다. 본 논문에서는 고차 shimming 을 통하여 불균일도를 개선하고, single shot 과 interleaving 을 적용한 multi-shot 나선주사영상 기법으로 $100{\times}100$에서 $256{\times}256$의 고해상도 영상을 얻어 고 자장에서 초고속영상기법으로 다양한 적용 가능성을 보였다.

  • PDF

직접방식 엑스선 검출기를 위한 $BiI_3$ 특성 연구 (A Study on Bismuth tri-iodide for X-ray direct and digital imagers)

  • 이상훈;김윤석;김영빈;정숙희;박지군;정원범;장무영;문치웅;남상희
    • 한국방사선학회논문지
    • /
    • 제3권2호
    • /
    • pp.27-31
    • /
    • 2009
  • 현재 의료용 엑스선 장비는 기존의 아날로그 방식의 필름, 카세트를 대신하여 디지털 방식인 CR, DR 이 널리 사용되면 그에 관한 연구개발이 활발히 진행되고 있다. 본 연구 에서는 디지털 엑스선 장비의 변환물질로 $BiI_3$(Bismuth tri-iodide)를 적용하여 실험하였으며 기존 선행연구에 비해 만족할만한 결과 값은 얻을 수 없었지만 가장 많이 사용되고 있는 a-Se(Amorphous Selenium)의 단점인 고전압인가와 제작방식의 어려움을 보완할 수 있는 새로운 가능성을 제시해 주었다. 본 연구에서 사용되어진 변환 물질은 순도 99.99%의 $BiI_3$가 이용되었으며 $3cm{\times}3cm$의 크기와 200um의 두께를 가지는 변환물질 층이 제작되었다. 변환 물질의 상하부에는 Magnetron Sputtering system장비를 이용한 ITO 전극이 형성되었다. 형성된 $BiI_3$ 엑스선 변환 물질의 특성 평가를 위해 구조적 분석과 전기적 분석이 이루어 졌다. SEM 측정을 통해 제작된 필름의 표면 및 단면적, 구성 성분을 관찰하였고, 전기적 분석을 위해서는 누설전류, 엑스선에 대한 신호량 및 잡음 대 신호비의 관찰이 이루어졌다. 실험 결과 $BiI_3$$1.6nA/cm^2$의 누설전류와 $0.629nC/cm^2$의 신호량을 측정할 수 있었으며, 이렇게 Screen print method로 제작된 엑스선 검출 물질은 PVD방법을 이용해 제작된 물질과 비슷하거나 더 나은 전기적 특성을 가지고 있었고 이는 제작 방법의 간소화 및 수율을 향상 시킬 수 있어 BiI3도 a-Se를 대체하기 위한 변환물질로 적합하다고 사료된다.

  • PDF

두정부 백질 물질을 이용한 수소 자기 공명 분광 분석 (Analysis of $^1H$ MR Spectroscopy of parietal white matter material Phantom)

  • 이재영;임청환;김명수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제26권2호
    • /
    • pp.57-61
    • /
    • 2003
  • 두정부 백질 물질 NAA, Choline(Cho), Creatine(Cr), choline chloride, glutamin 등으로 자체 제작한 phantom을 이용하여 고 자장(4.7T)과 중자장(1.5T)에서의 신호강도 대 잡음비, 스펙트럼 분해능을 알아 볼 수 있는 선폭과 $T_2$, 그리고 $T_E$값의 변화에 따른 각 대사물질의 변화별 스펙트럼 등을 구하여 이론적인 정보와 실제적인 정보와의 차이를 알아보고자 한다. 이용된 기기는 Bruker Biospec 4.7T와 1.5T GE SIGNA를 이용하여 MRS의 결과를 얻었다. 관심영역에서 얻은 정보에서 분광 peak의 면적을 구하였다. 통계처리는 Microsoft사의 Excel program내에 있는 통계 package를 이용하였다. 중자장(1.5T)과 고자장(4.7T)에서의 각각의 대사물질의 스펙트럼을 얻어 본 결과 자장의 균일도와 SNR과 $T_2$값의 차이가 이론적인 값보다는 직선성을 보이지 않았다. 1.5T에서의 선폭은 Cho, Cr, NAA 순서로 $5.30{\pm}1.07,\;4.81{\pm}0.14,\;5.49{\pm}0$, 이에 반해 4.7T에서는 $9.14{\pm}0.55,\;8.87{\pm}0.67,\;9.65{\pm}0.56$ Hz 값이 나왔다. 평균 SNR은 NAA의 물질의 경우를 3회 측정하였는데 그 평균치는 63%의 증가를 보였다. $T_E$ 변화로 스펙트럼을 분석했을 때 $T_E=60ms$일 때 가장 SNR이 좋은 값을 보였고 $T_E=135ms$일 때 가장 낮은 값을 나타나 보였다. 두정부 백질 물질 Phantom을 제작하여 자장의 강도 즉 중자장(1.5T)과 고자장(4.7T)에 따라 분석하게 되었는데 고자장의 영역으로 갈수록 분해능, SNR은 좋아져 보이나 자장의 세기가 커질수록 이론적인 수치보다는 상당히 적은 증가를 보이고 있다는 것을 이 연구를 통해 알게 되었다.

  • PDF

FLASH를 이용한 3T 복부검사에 있어서 최적의 T1효과를 위한 적정 Flip Angle (Flip Angle of the Optimal T1 Effect Using FLASH Pulse Sequence at 3T Abdominal MRI)

  • 한재복;최남길
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권1호
    • /
    • pp.101-106
    • /
    • 2009
  • 본 연구는 FLASH 펄스파형을 이용하여 숙임각(flip angle ; FA)변화에 따른 T1 강조영상의 신호강도(signal intensity ; SI)와 대조도 대 잡음비(contrast to noise ratio ; CNR)를 비교함으로써 복부검사에서의 최적의 T1효과를 나타내기 위한 FA를 알아보고자 하였다. 2008년 9월부터 12월까지 본원을 내원하여 복부 MRI 검사를 시행한 환자 20명(남 : 12명, 여 : 8명, 연령 범위 : $28{\sim}63$세, 평균 : 51세)을 대상으로 하였다. 영상 장비는 3Tesla MR scanner(Magnetom Tim Trio, SIEMENS, Germany)였으며, 8 channel body array coil을 사용하였다. 사용된 영상변수는 FLASH 펄스파형과 TR : 120 ms, TE : minimum, FOV : $360{\times}300\;mm$, Matrix : $256{\times}224$, Slice : 6 mm, scan time : 15초로 Breath-hold 기법을 이용하였다. 복부 영상은 물 신호를 동시에 측정하기 위해 관심영역(FOV) 안에 물을 채운 50 ml syringe를 놓고 $10^{\circ}$부터 $90^{\circ}$까지 $10^{\circ}$ 간격으로 FA에 변화를 주면서 얻었다. 획득한 영상은 간(liver), syringe내부의 물(water), 비장(spleen), background의 신호강도(SI)와 대조도 대 잡음비(CNR)를 각각 측정하였으며 신호강도는 관심영역을 설정한 다음 각 부위에서 3번씩 측정하고 그 평균값을 구하였다. 영상 전체의 평가에서는 변이계수(coefficient of variation)를 적용하여 전체영상의 신호강도 균일도를 알아보았고 통계 분석은 SPSS for window version 17.0을 이용하였다. 간(liver)의 신호강도는 $475.54{\pm}81.76$으로 FA $40^{\circ}$에서 가장 높게 나타났으며 syringe내부의 물의 신호는 $475.97{\pm}68.98$로 FA $20^{\circ}$에서 가장 높았으며 FA가 높아짐에 따라 다른 조직의 신호보다 많은 감소를 보였다. 비장의 신호는 $443.02{\pm}55.77$로 FA $30^{\circ}$에서 가장 높은 신호강도를 보였으며 FA가 높아짐에 따라 신호가 감소하였다. 조직의 신호강도에서 Liver vs Water와 Liver vs Spleen은 FA $30^{\circ}$를 제외한 전 구간에서 통계적으로 유의한 차이를 보였고 Water vs Spleen은 FA $60^{\circ}$, FA $70^{\circ}$, FA $80^{\circ}$에서만 유의한 차이를 보였다(p < 0.01). 전체영상의 신호강도는 $175.42{\pm}57.93$으로 FA $10^{\circ}$에서 가장 낮게 나타났으며 FA가 높아짐에 따라 증가하다가 떨어지는 양상을 보였다. 또한 변이계수(coefficient of variation)는 FA $10^{\circ}$와 FA $20^{\circ}$에서 33.02와 31.43으로 가장 높게 나타났다. FA $10^{\circ}$와 FA $20^{\circ}$는 전체영상의 신호강도 균일도가 다소 떨어지는 영상으로 왜곡이 심하게 나타났다. CNR은 liver-water에서 FA $30^{\circ}$에서 12.73으로 가장 낮게 나타났고 FA $10^{\circ}$에서 -46.97, FA $80^{\circ}$에서 29.36으로 가장 높게 나타났다. liver-spleen의 CNR에서는 FA $10^{\circ}$에서 -3.18로 가장 낮게 나타났으며 FA $80^{\circ}$에서 9.65로 가장 높게 나타났다. 결론적으로 FLASH 펄스 파형을 사용한 복부 영상에서 최적의 T1효과를 나타내기 위해서는 FA $80^{\circ}$를 사용하는 것이 유용할 것으로 생각된다.

  • PDF

국민참여형 도로계획의 수립방향 (Building up User-Oriented Road Planning and Design Schemes)

  • 김응철;권영인;윤성순;강진구
    • 대한교통학회지
    • /
    • 제23권5호
    • /
    • pp.47-55
    • /
    • 2005
  • 1960년대 이후에 추진된 국가경제개발과 함께 지속적으로 건설되기 시작한 우리나라의 도로는 2003년말 현재 총 도로연장 약 97,000km, 그 중에 고속도로가 약 2,800km에 이르게 되었으며, 국가경제와 사회, 문화발전에 지대한 공헌을 하였고 중요한 역할을 담당하고 있다. 이와 함께 도로사업에 대한 국민의 관심이 증가하여 서울외곽순환도로 사패산 구간 등의 경우에는 불교계와 환경단체의 반대로 약 1년 8개월간의 공사중단사태가 발생하기도 하였으며, 1997년에 기본계획이 수립된 강남순환도로는 아직까지 공사가 착공하고 있지 못한 상태로써 국가가 주도적으로 사업을 시행하고 대다수 국민들이 이를 수동적으로 수용하던 과거와는 달리 최근에는 국민의 의식수준향상과 정책에의 참여욕구가 증대되고 또한 환경에 대한 관심이 고조되면서 대규모도로사업에 대한 반대 및 물리적인 충돌로 사업시행이 지체되면서 국가 경제적인 손실로 갈등이 빈번히 발생되고 있는 실정이다. 선진 외국의 경우에는 도로사업의 효율적인 추진을 위하여 약 20-30년 전부터 국민참석 (주민참여, Public Involvement)기법을 적극적으로 도입하여 시행하고 있으며 이러한 시점에서 국가적으로 중요한 도로사업의 정책방향수립을 위하여 도로사업의 단계별 추진과정과 문제점을 점검하여 적극적인 국민참여의 방안을 제시하여 도로사업에 있어서의 원활한 추진을 도모하기 위한 국민참여형 도로사업의 정책방향이 제시되어야 한다. 도로사업의 원활한 시행을 위한 국민참여형 도로계획의 수립방안을 실현하기 위하여는 다음과 같은 개선방안이 시행되어야 할 것이다. 첫째 사업의 투명성과 객관성 확보방안이 마련되어야 할 것이다. 둘째, 기존 갈등에 대한 합의사례를 바탕으로 합리적인 조정방안과 기준이 제시되어야 할 것이다. 셋째, 도로사업의 원활한 추진을 위한 국민참여형 도로계획은 우리나라의 여건상 점진적으로 도입, 확대되어야 할 것이며, 마지막으로 사전교육을 위한 전문가 양성, 관계자의 교육 및 훈련프로그램 등에 대한 방안을 검토하여야 한다.

가정산소치료의 보험급여 실시 이후 처방 실태: 다기관 조사 -만성기도폐쇄성질환 임상연구센터 제3세부과제 만성기도폐쇄성질환 진료지침 개발/보급 연구- (Long-term Oxygen Therapy for Chronic Respiratory Insufficiency: the Situation in Korea after the Health Insurance Coverage: a Multi-center Korean Survey -Study for the Development and Dissemination of the COPD Guidelines, Clinical Research Center for Chronic Obstructive Airway Disease-)

  • 박명재;유지홍;최천웅;김영균;윤형규;강경호;이승룡;최혜숙;이관호;이진화;임성철;김유일;신동호;김태형;정기석;박용범
    • Tuberculosis and Respiratory Diseases
    • /
    • 제67권2호
    • /
    • pp.88-94
    • /
    • 2009
  • Background: From November 2006, The national health insurance system in the Republic of Korea began to cover prescribed long-term oxygen therapy (LTOT) in patients with chronic respiratory insufficiency. This study examined the current status of LTOT after national health insurance coverage. Methods: Between November 1, 2006 and June 30, 2008, the medical records of patients who were prescribed LTOT by chest physicians were reviewed. The data was collected from 13 university hospitals. Results: 197 patients (131 male and 66 female) were prescribed LTOT. The mean age was 64.3${\pm}$13.0 years. The most common underlying disease was chronic obstructive pulmonary disease (n=103, 52.3%). Chest physicians prescribed LTOT using arterial blood gas analysis or a pulse oxymeter (74.6%), symptoms (14%), or a pulmonary function test (11.2%). The mean oxygen flow rate was 1.56${\pm}$0.68 L/min at rest, 2.08${\pm}$0.91 L/min during exercise or 1.51${\pm}$0.75 L/min during sleep. Most patients (98.3%) used oxygen concentrators. Only 19% of patients used ambulatory oxygen supplies. The oxygen saturation before and after LTOT was 83.18${\pm}$10.48% and 91.64${\pm}$7.1%, respectively. After LTOT, dyspnea improved in 81.2% of patients. The mean duration of LTOT was 16.85${\pm}$6.71 hours/day. The rental cost for the oxygen concentrator and related electricity charges were 48,414${\pm}$15,618 won/month and 40,352${\pm}$36,815 won/month, respectively. Approximately 75% of patients had a regular visit by the company. 5.8% of patients had personal pulse oxymetry. 54.9% of patients had their oxygen saturation checked on each visit hospital. 8% of patients were current smokers. The most common complaint with LTOT was the limitation of daily activity (53%). The most common complaint with oxygen concentrators was noise (41%). Conclusion: The patients showed good compliance with LTOT. However, only a few patients used an ambulatory oxygen device or had their oxygen saturation measured.

게이트 심근 SPECT 분석 소프트웨어의 개발과 좌심실 수축 기능 평가 (Development of Gated Myocardial SPECT Analysis Software and Evaluation of Left Ventricular Contraction Function)

  • 이병일;이동수;이재성;정준기;이명철;최흥국
    • 대한핵의학회지
    • /
    • 제37권2호
    • /
    • pp.73-82
    • /
    • 2003
  • 목적: 게이트 심근 SPECT 영상 데이터에서 좌심실을 분할하고 단위영상 각각의 심실부피를 계산하는 소프트웨어를 개발하였다. 개발한 소프트웨어에서 얻은 구혈률을 상용 소프트웨어QGS (Quantitative Gated SPECT)에서 산출한 값과 비교하여 검증하였다. 대상 및 방법: 게이트 심근 SPECT를 시행하여 구혈률 15%-80%, 확장기말 부피는 49 mL-293 mL, 수축기말 부피는 8 mL-250 mL인 40명의 영상데이터를 사용하여 이 연구에서 개발한 CSA (Cardiac SPECT Analyzer)로 구혈률과 부피를 산출하여 QGS로 얻은 결과와 비교하였다. 같은 영상을 CSA로 두 번 분석하여 구혈률과 부피가 같은 값이 나오는지 보고, 26명의 환자에서 같은 자리에서 두 번 이어서 얻은 게이트 SPECT 영상을 CSA로 분석하여 편차를 조사하였다. 결과: CSA측정과 QGS 측정의 상관성은 상관계수가 구혈률, 확장기말 부피, 수축기말 부피 각각 0.97, 0.92, 0.96이었고 Bland Altman 도표에 치우침 없이 2표준편차가 구혈률의 경우 10.1%이었다. 같은 영상에 대한 CSA 2회 측정 결과의 상관은 0.96, 0.99, 0.99 이었고 구혈률의 2표준편차는 3.4%이었다. 두 번 연속 촬영한 영상으로 CSA 분석한 결과 상관계수는 0.89, 0.97, 0.98, 이었고 변이계수는 8.2%, 5.4mL, 8.5mL, Bland Altman 도표 2표준편차는 구혈률의 경우 10.6%이었다. 결론: 게이트 심근 SPECT에서 얻은 영상으로 구혈률을 측정할 수 있는 소프트웨어를 개발하였다. 이 소프트웨어로 얻은 구혈률, 화장기말 부피, 수축기말 부피는 정확하며 정밀하였다. 구혈률의 2표준편차는 10.6%이었다.

국산 산소 농축기의 개발 및 동물실험 (Development and Animal Tests of Prototype Oxygen Concentrator)

  • 변정욱;성숙환;이태수
    • Journal of Chest Surgery
    • /
    • 제31권7호
    • /
    • pp.643-649
    • /
    • 1998
  • 장기간 산소 호흡치료가 필요한 만성호흡부전증 환자에서 가정내 산소 농축기의 사용은 이미 보편화 되어있고 적응 및 사용빈도도 증가추세에 있다. 본 연구팀이 최근 개발한 국산 산소농축기의 성능검사와 보완점을 찾기위해 이미 시판되어 사용중인 외국산 산소농축기(FOR LIFE\ulcorner, Air Sep Corp. USA)와 비교 분석하여 효용성 및 안정성을 검증하고자 하였다. 기계적 성능 시험으로는 제작한 시제품과 외굿산 산소농축기를 4시간 연속 작동후 발생되는 산소농도를 측정하였으며, 동물실험은 잡견 16마리를 각 군당 8마리씩 A군, B군으로 나누어 A군은 외국산 산소농축기로, B군은 자체 개발한 산소농축기로 분당 5 리터의 산소를 공급하여 기본활력증후, 동맥혈 가스분석 및 혈액 화학 검사 등을 검사하였다. 4시간 연속 작동후 발생하는 산소 농도는 외산 98$\pm$3%, 국산 91$\pm$1 %로 외산이 우수하였다. 동물실험에서 산소 공급후 1, 2, 3, 4시간에 산소마스크 주입구에서 측정한 산소 농도는 A군에서 각각 70.6$\pm$2.5%, 67.1$\pm$2.9%, 68.2$\pm$2.6%, 64.9$\pm$3.9%, B군에서는 65.1$\pm$4.8%, 65.2$\pm$3.6%, 68.7$\pm$4.3%, 66.0$\pm$5.0%로 두 군간에 유의한 차이를 보이지 않았으며 (반복측정 분산분석 p=0.70), 산소투여 전 및 투여 후 1, 2, 3, 4 시간의 동맥혈 산소분압은 A군에서 각각 87.2$\pm$2.5 mmHg, 347.4$\pm$29.3 mmHg, 353.4$\pm$21.2 mmHg, 343.0$\pm$28.8 mmHg, 321.6$\pm$24.4 mmHg, B군에서 각각 102.5$\pm$9.6 mmHg, 300.3$\pm$17.1 mmHg, 321.6$\pm$23.7 mmHg, 303.4$\pm$27.4 mmHg, 273.5$\pm$25.9 mmHg로 비록 통계적 유의성은 없었으나(p=0.24) 외산 산소 농축기를 사용한 군에서 동맥혈 산소분압이 다소 높은 경향을 보였다. 이상으로부터 본연구팀이 현재 개발중인 국산 산소 농축기의 시제품의 성능을 시험한 결과 외산 산소 농축기와 비교하여 비교적 만족스러운 성능을 보였으나 소음, 내구성 등의 개선할 부분이 지적되었다.

  • PDF

한국인 조현병 환자에서CNR1 유전자의 (AAT)n 삼핵산 반복 다형성과 안구추적운동 이상에 대한 연합 연구 (No Association between (AAT)n Repeat Polymorphisms in the Cannabinoid Receptor 1 Gene and Smooth Pursuit Eye Movement Abnormality in Korean Patients with Schizophrenia)

  • 김민재;김채리;박진완;백두현;신형두;최인근;한상우;황재욱;이연정;우성일
    • 생물정신의학
    • /
    • 제23권4호
    • /
    • pp.148-156
    • /
    • 2016
  • Objectives According to previous studies, the cannabinoid receptor 1 (CNR1) gene could be an important candidate gene for schizophrenia. Some studies have linked the (AAT)n trinucleotide repeat polymorphism in CNR1 gene with the risk of schizophrenia. Meanwhile, smooth pursuit eye movement (SPEM) has been regarded as one of the most consistent endophenotypes of schizophrenia. In this study, we investigated the association between the (AAT)n trinucleotide repeats in CNR1 gene and SPEM abnormality in Korean patients with schizophrenia. Methods We measured SPEM function in 167 Korean patients with schizophrenia (84 male, 83 female) and they were divided according to SPEM function into two groups, good and poor SPEM function groups. We also investigated allele frequencies of (AAT)n repeat polymorphisms on CNR1 gene in each group. A logistic regression analysis was performed to find the association between SPEM abnormality and the number of (AAT)n trinucleotide repeats. Results The natural logarithm value of signal/noise ratio (Ln S/N ratio) of the good SPEM function group was $4.34{\pm}0.29$ and that of the poor SPEM function group was $3.21{\pm}0.70$. In total, 7 types of trinucleotide repeats were identified, each containing 7, 10, 11, 12, 13, 14, and 15 repeats, respectively. In the patients with $(AAT)7$ allele, the distributions of the good and poor SPEM function groups were 18 (11.1%) and 19 (11.0%) respectively. In the patients with $(AAT)_{10}$ allele, $(AAT)_{11}$ allele, $(AAT)_{12}$ allele, $(AAT)_{13}$ allele, $(AAT)_{14}$ allele and $(AAT)_{15}$ allele, the distributions of good and poor SPEM function groups were 13 (8.0%) and 12 (7.0%), 4 (2.5%) and 6 (3.5%), 31 (19.8%) and 35 (20.3%), 51 (31.5%) and 51 (29.7%), 36 (22.2%) and 45 (26.2%), 9 (5.6%) and 4 (2.3%) respectively. As the number of (AAT) n repeat increased, there was no aggravation of abnormality of SPEM function. Conclusions There was no significant aggravation of SPEM abnormality along with the increase of number of (AAT)n trinucleotide repeats in the CNR1 gene in Korean patients with schizophrenia.