• Title/Summary/Keyword: noise addition

Search Result 1,866, Processing Time 0.028 seconds

A Study of Acoustic Noise Analysis and Reduction Method for Driving CD-ROM (CD-ROM 구동 시 발생소음 분석 및 저감 방안에 관한 연구)

  • 이재승;차성운
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.904-907
    • /
    • 2002
  • Optical disk drive device is improved in rotating speed for faster data reading. In the case of CD-ROM, rotating speed is over 10000 rpm in the practical use. As a result of high rotating speed, unexpected effects as like increasing disk fluctuation and acoustic noise are raised by the air friction on the rotating disk and the eccentricity of rotating parts. The overall acoustic noise of running CD-ROM could be classified into two different characterized noise. The first is the structural-borne noise which is generated from vibrating solid body. By the reason, the signal of structural borne noise has very similar to the signal of surface vibrating one. It has dense noise energy at specific frequency region. The other is the air-borne noise which is generated from turbulence or vortex caused by friction between disk and air. The signal of air-borne noise has no dominant peak point at acoustic pressure-frequency domain. The noise energy is widely distributed while comparatively high and large frequency region. The structural-borne noise could be reduced by reducing vibration of structure and in addition it's target reducing frequency is narrow. However the air-borne noise reduction is effectively needed of enclosing method for the noise source located near the disk surface because it is difficult to define target frequency point. In this study, the acoustic noise at driving CD-ROM is classified by the sides of it's character and tried to reduce the overall acoustic noise.

  • PDF

The Study on the Characteristic Sound Intensity and Frequency of Noise Exposure at Occupational Sites (산업장 소음의 강도 및 주파수 특성에 관한 조사연구)

  • Kim, Kwang Jong;Cha, Chul Whan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.181-191
    • /
    • 1991
  • The present study determined the overall noise level and the distribution of sound pressure level over audible frequency range of noise produced at various work sites. Work-related noise greater than 80dBA produced from 98 separate work sites at 37 manufacturing companies and machine shops were analysed for the overall sound level (dBA) and frequency distribution. In addition, to determine the possible hearing loss related to work site noise, a hearing test was also conducted on 1,374 workers in these work sites. The results of the study were as follows ; 1. Of the total 98 work sites, 57 work sites(58.2%) produced noise exceeding threshold limit value (${\geq}90dBA$) set by the Ministry 01 Labor. In terms of different manufacturing industries the proportion of work sites which exceeded 90dBA was the highest for the cut-stone products industry with 6/6 work sites and lowest for the commercial printing industry with 1/13 work sites. 2. The percentage of workers who were exposed to noise greater than 90dBA was 19.8% (1,040 workers) 01 the total 5,261 workers. In terms of different industries, cut-stone products industry had the most workers exposed to noise exceeding 90dBA with 82.8%, textile bleaching and dyeing industry was next at 30.6% followed by fabricated metal products industry with 27.9%, plastic products manufacturing industry had the lowest percentage of workers exposed to 90dBA exceeding noise with 4.5%. 3. There was a statistically significant correlation between the frequency of noise-induced hearing loss and the percentage of workers exposed to noise exceeding 90dBA (P<0.05). 4. The frequency analysis of noise produced at the 98 work sites revealed that 44 work sites (44.9%) had the maximum sound pressure level at high-frequencies greater than 2KHz. In addition, significantly higher sound pressure level was detected at the high-frequencies at 90dBA exceeding work sites as compared to below 90dBA work sites (P<0.01). 5. The differences in sound level meter's A-and C-weighted sound pressure levels were analysed by frequencies. Of the 28 work sites which showed 0-1 dB difference in the two weighted sound levels, 20 work sites (71.4%) had significantly higher sound pressure levels at high-frequencies greater than 2KHz (P<0.01). Furthermore, there was a tendency for higher sound pressure levels to occur in the high-frequency range as the differences in the two weighted sound levels decreased.

  • PDF

Study on Establishment of the Noise Grade Criteria for Household Appliances (가전제품 소음등급 기준설정에 관한 연구)

  • Park, Hyungkyu;Lee, Jaewon;Lee, Wooseok;Han, Jinseok;Gu, Jinhoi
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.12
    • /
    • pp.1237-1242
    • /
    • 2012
  • No matter how low it might be, noise from home appliances in indoor environment cause displeasure for residents as it is produced nearby. Electronic goods including vacuum cleaner and washing machine generate high frequency noise, which interrupts TV-watching or conversations and cause noises between floors in apartment houses. In particular, refrigerators make constant noise late at night, hampering the study for exams and causing sleeplessness. Korea, despite the government's efforts to promote low-noise goods based on the noise test by corporation, there is a lack of standardization in the test method, test condition and measuring equipments. This is a major reason that lowers the reliability of low-noise products. At present, low-noise home appliances are certified with eco labeling in the nation but, only 7 brands of refrigerators, 4 brands of washing machines and 97 brands of air-conditioners obtained certification as of august, 2011. In addition, none of Kimchi-refrigerator and vacuum cleaner brands were approved as low-noise home appliances. This shows Korea's relatively underdeveloped market for low-noise products, which, in part, is because of the difficulties companies face in being certified with eco labeling as they should satisfy various requirements such as power-saving and eco-friendly design besides low-noise features. As a result, low-noise labeling for home appliances should be established for the revised noise and vibration management law and the study was carried out to establish low-noise labeling system for major noise sources including vacuum cleaner, washing machine, air-conditioner and refrigerator.

A Study on the Noise Reduction of Reciprocating Type Air Compressors

  • Lee Kwang-Kil;Kim Kwang-Jong;Lee Gwan-Hyung;Park Jae-Suk;Son Doo-ik;Kim Bong-Ki;Lee Dong-Ju
    • International Journal of Safety
    • /
    • v.3 no.1
    • /
    • pp.6-9
    • /
    • 2004
  • This paper deals with the noise evaluation technique of a reciprocating air-compressor and its noise reduction. The reciprocating air-compressors are widely used in the small, medium sized industrial firms, and lots of their employees are affected and irritated by their noise in the workplace. Thus, noise control actions should be taken appropriately by considering the hearing loss due to the occupational noise exposure. Lead-wrapping techniques are employed to identify the contribution of principal noise sources which are generally known as motor, belts, suction/discharge valves, moving pistons, and flow-induced noise caused by edges or discontinuities along the flow path e.g. expansions, contractions, junctions and bends etc .. As a result, main noise sources of the air-compressor can be categorized by the suction/discharge noise, valve noise, and compressed-air tank noise. Based on the investigations, mufflers are designed to reduce both the suction/discharge noise and the compressed-air tank noise. Instead of the conventional valve plate, polyethylene resin is used as a new one for the reduction of valve impact noise. In addition, attempts are made to reduce the valve noise propagation to the cylinder head and the compressor tank by using the insulation casings. As a result of the countermeasure plans, it can be achieved that the noise reduction of the air-compress is up to 10dB.

Evaluation of Noise Decreasing Effects by Structures in Roadside Buffer Green (도로변 완충녹지 구조에 따른 소음저감효과 평가)

  • Kim, Jeong-Ho;Oh, Deuk-Kyun;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.24 no.5
    • /
    • pp.647-655
    • /
    • 2015
  • In this study, to targeting Songpa of Seoul, were analyzed the effect on the noise mitigation in roadside buffer green spaces. Noise of Songpa Street buffer green space was determined to be higher during the day than at night. In addition, it was most of 60 db or more. However, the noise reduction function of the buffer green was not greatly affected by time. In the case of noise reduction rate, during the day time it was the order of the mounding type (18.14%)> plain type (5.73%)> slope type (4.08%), And, in the case of night time, it was the order of the mounding type (11.29%)> slope type (10.22%)> plain type (4.42%). Noise reduction rate, all of the daytime, was the highest in the mounding type. As a result of the factors on the amount of reduction of noise, More physical structure is mounding type, green structure is the stratification of green space, and the number of individuals is large, the higher the tree planting density, it is determined that the noise reduction effect is high. Also, factors affecting the noise reduction effect of the day and night were different.

Noise characteristics in a jigging fishing vessel of 300 tons class (300톤급 채낚기 어선의 공중소음 특성)

  • Lee, Yoo-Won;Kim, Wook-Sung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.1
    • /
    • pp.91-98
    • /
    • 2012
  • This study is aimed to utilize a basic data for setting up an allowable air noise with IMO standard in accommodation and working areas of 24m longer fishing vessels. The air noise in accommodation and working areas of 300 tons class squid-jigger were evaluated and the levels were compared to the allowable levels of IMO. The results indicated that the maximum range of noise levels was estimated to be between 54.8dB (A) and 83.2dB, and the correlation between the distance from the main engine to measuring point and the maximum noise level of each point was shown to be y=-13.8log (r)+92.91 ($r^2=0.821$). In addition, except the case of making an accommodation area near to the engine room in 24m longer jigging vessels, it was evaluated that the accommodation noise regulation of 1,600 tons international voyage vessels with 60dB (A) or an improved noise level with 65dB (A) could be properly applied.

Study of the Indoor Noise Limit for Naval Vessels Considering the Satisfaction of the Crew (승조원의 만족도를 고려한 함정의 함내소음 기준 분석)

  • Han, Hyung-Suk;Park, Mi-Yoo;Cho, Heung-Gi
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.4
    • /
    • pp.589-597
    • /
    • 2010
  • The indoor noise of the naval vessel is very important considering hearing protection, improvement of working environment and easily communication between crews. When the environment of the naval vessel suffering from the noise is considered, it is very important to be quiet in the living area where the crews have a rest sufficiently. In addition, the noise of the working area should be reduced in order to increase working efficiency. Therefore, in this research, the satisfactions about the indoor noise are survey for crews working in a naval vessel. Through this survey, the relationship between the indoor noise and crew's satisfaction about it can be found. As a result, the limit of sound pressure level which almost all crew can be satisfied with the indoor noise about their living and working area is suggested base on the survey in this research.

Adaptive Noise Detection and Removal Algorithm Using Local Statistics and Noise Estimation (국부 통계 특성 및 노이즈 예측을 통한 적응 노이즈 검출 및 제거 방식)

  • Nguyen, Tuan-Anh;Kim, Beomsu;Hong, Min-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.2
    • /
    • pp.183-190
    • /
    • 2013
  • In this paper, we propose a spatially adaptive noise detection and removal algorithm for a single degraded image. Under the assumption that an observed image is Gaussian-distributed, the noise information is estimated by local statistics of degraded image, and the degree of the additive noise is detected by the local statistics of the estimated noise. In addition, we describe a noise removal method taking a modified Gaussian filter which is adaptively determined by filter parameters and window size. The experimental results demonstrate the capability of the proposed algorithm.

Performance evaluation of noise reduction algorithm with median filter using improved thresholding method in pixelated semiconductor gamma camera system: A numerical simulation study

  • Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.439-443
    • /
    • 2019
  • To improve the noise characteristics, software-based noise reduction algorithms are widely used in cadmium zinc telluride (CZT) pixelated semiconductor gamma camera system. The purpose of this study was to develop an improved median filtering algorithm using a thresholding method for noise reduction in a CZT pixelated semiconductor gamma camera system. The gamma camera system simulated is a CZT pixelated semiconductor detector with a pixel-matched parallel-hole collimator and the spatial resolution phatnom was designed with the Geant4 Application for Tomography Emission (GATE). In addition, a noise reduction algorithm with a median filter using an improved thresholding method is developed and we applied our proposed algorithm to an acquired spatial resolution phantom image. According to the results, the proposed median filter improved the noise characteristics compared to a conventional median filter. In particular, the average for normalized noise power spectrum, contrast to noise ratio, and coefficient of variation results using the proposed median filter were 10, 1.11, and 1.19 times better than results using conventional median filter, respectively. In conclusion, our results show that the proposed median filter using improved the thresholding method results in high imaging performance when applied in a CZT semiconductor gamma camera system.

DWT-Based Parameter and Iteration Algorithm for Preventing Arc False Detection in PV DC Arc Fault Detector (태양광 직렬 아크 검출기의 오검출 방지를 위한 DWT 기반 파라미터 및 반복 알고리즘)

  • Ahn, Jae-Beom;Lee, Jin-Han;Lee, Jin;Ryoo, Hong-Je
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.2
    • /
    • pp.100-105
    • /
    • 2022
  • This paper applies the arc detection algorithm to prevent the false detection in photo voltaic series arc detection circuit, which is required not only to detect the series arc quickly, but also not falsely detect the arc for the non-arc noise. For this purpose, this study proposes a rapid and preventive false detection method of single peak noise and short noise signals. First, to prevent false detection by single peak noise, Discrete wavelet transform (DWT)-based characteristic parameters are applied to determine the shape and the amplitude of the noise. In addition, arc fault detection within a few milliseconds is performed with the DWT iterative algorithm to quickly prevent false detection for short noise signals, considering the continuity of serial arc noise. Thus, the method operates not only to detect series arc, but also to avoid false arc detection for peak and short noises. The proposed algorithm is applied to real-time serial arc detection circuit based on the TMS320F28335 DSP. The serial arc detection and peak noise filtering performances are verified in the built simulated arc test facility. Furthermore, the filtering performance of short noise generated through DC switch operation is confirmed.