• Title/Summary/Keyword: no-reference

Search Result 2,171, Processing Time 0.026 seconds

Study of the Application of Gel Electrolyte in the Reference Electrode of $Cu/CuSO_4$

  • Lin, Cunguo;Xu, Likun;Liu, Yang
    • Corrosion Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.179-181
    • /
    • 2008
  • With nano-$SiO_2$ and sulphate acid, a kind of colloid electrolyte is synthesized by sol-gel method. It is placed outside the reference electrode as a layer of gel electrolyte so as to decrease the leaching of $Cu^{2+}$ and increase the life of the reference electrode. The performance of the gel electrode in simulating soil solution is measured as follows: the potential of the electrodes ranging from 60 mV to 80 mV (vs. SCE) with potential variation no more than $\pm10mV$, enough resistance to polarization. The $Cu^{2+}$ effusion rate of the reference electrode without gel electrolyte is 3 times that with colloid electrolyte, which means that gel electrolyte can extend the life of the reference electrode significantly.

Bioequivalence Study of Loxoprofen Sodium in healthy Volunteers (Loxoprofen sodium 제제(레녹스정)의 생물학적 동등성시험)

  • 최주영;유내춘;박민수;김경환
    • Biomolecules & Therapeutics
    • /
    • v.6 no.4
    • /
    • pp.417-422
    • /
    • 1998
  • Loxoprofen sodium (sodium 2-[4-(2-oxocyclopentylmethyl)phenyl] propionate dehydrate) is a nonsteroidal antiinflammatory drug of $\alpha$-phenyl propionic acid derivative. To test the bioequivalence of loxoprofen, the pharmacokinetic parameters of new preparation of loxoprofen, LENOX was compared with LOXONIN as a reference drug. Fourteen healthy volunteers were entered to the stydy (Yonsei University College of Medicine, Severance Hospital IRB approval No. 9608). They were administered 60 mg of loxoprofen in 2$\times$2 cross-over design. There was one week of drug-free interval between doses. The blood sample was taken on schedule up to 8 hours, and the plasma concentration loxoprofen was measured by reverse phase high-performance liquid chromatography (HPLC) with UV-detector. There were no significant difference between two preparations when AUC, Cmax, and Tmax were compared by ANOVA. The mean differences of AUC, Cmax, and Tmax were within 20% of the reference drug: the values were 2.22,5.61, and 12.50%, respectively. The confidence limits of AUC and Cmax but not Tmax satisfied the bioequivalence criteria. These results suggest that the tested LENOX is bioequivalent to the reference drug.

  • PDF

A No-Reference Adaptive Metric for Digital Image Quality Assessment

  • Lim, Jin-Young;Kang, Dong-Wook;Kim, Ki-Doo;Jung, Kyeong-Hoon
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.316-320
    • /
    • 2009
  • In this paper, a reference-free perceptual quality metric is proposed for image assessment. It measures the amount of overall blockiness and blurring in the image. And edge-oriented artifacts, such as ringing, mosaic and staircase noise are also considered. In order to give a single quality score, the individual artifact scores are adaptively combined according to the difference between the edge-oriented artifacts and other artifacts. The quality score obtained by the proposed algorithm shows strong correlation with the MOS values by VQEG.

  • PDF

Bayesian Model Selection in the Gamma Populations

  • Kang, Sang-Gil;Kang, Doo-Young
    • Journal of the Korean Data and Information Science Society
    • /
    • v.17 no.4
    • /
    • pp.1329-1341
    • /
    • 2006
  • When X and Y have independent gamma distributions, we consider the testing problem for two gamma means. We propose a solution based on a Bayesian model selection procedure to this problem in which no subjective input is considered. The reference prior is derived. Using the derived reference prior, we compute the fractional Bayes factor and the intrinsic Bayes factors. The posterior probability of each model is used as a model selection tool. Simulation study and a real data example are provided.

  • PDF

OBJECTIVE BAYESIAN APPROACH TO STEP STRESS ACCELERATED LIFE TESTS

  • Kim Dal-Ho;Lee Woo-Dong;Kang Sang-Gil
    • Journal of the Korean Statistical Society
    • /
    • v.35 no.3
    • /
    • pp.225-238
    • /
    • 2006
  • This paper considers noninformative priors for the scale parameter of exponential distribution when the data are collected in step stress accelerated life tests. We find the Jeffreys' and reference priors for this model and show that the reference prior satisfies first order matching criterion. Also, we show that there exists no second order matching prior in this problem. Some simulation results are given and we perform Bayesian analysis for proposed priors using some data.

Determination of Terrestrial Reference Frame using a Space Geodetic Technique (우주측지기술을 이용한 지구기준좌표계 결정)

  • Yoo, Sung-Moon;Cho, Jung-Ho
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2010.04a
    • /
    • pp.43-44
    • /
    • 2010
  • We present the analysis of space geodetic technique observation, Satellite Laser Ranging (SLR), to LAGEOS1 and LAGEOS2 for the definition of the Terrestrial Reference Frame (TRF). The data were analyzed in 7day arcs during about 9 years (2000/01/10 ~ 2008/12/29) using NASA Goddard's GEODYN/SOLVE II software. The comparison of the coordinates between ITRF2005 and TRF solutions determined in this work shows that there is no significant bias.

  • PDF

Reference Prior and Posterior in the AR(1) Model

  • Lee, Yoon-Jae
    • Journal of the Korean Data and Information Science Society
    • /
    • v.16 no.1
    • /
    • pp.71-78
    • /
    • 2005
  • Recently an important issue in Bayesian methodology is determination of noninformative prior distributions, often required when there is no idea of prior information. In this thesis attention is focused on the development of noninformative priors for stationary AR(1) model. The noninformative priors primarily discussed are the Jeffreys prior, and the reference priors. The remarkable points in the result are that the Jeffreys prior coincides with the reference prior for the case that $\rho$ is the parameter of interest.

  • PDF

A study on the renal dysfunction among workers exposed to organic solvent mixtures (저농도 복합유기용제 노출근로자의 신기능 변화에 관한 연구)

  • Kim, Jung Won;Paik, Soo Dong;Lee, Chang Hee;Kim, Jung Ho;Kang, Dong Mug;Moon, Deog Hwan;Lee, Chae Un
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.2
    • /
    • pp.153-160
    • /
    • 2001
  • Objectives : The authors evaluated the effects on renal function of workers chronically exposed to low-level organic solvent mixtures. Methods : The authors measured the level of urine ${\beta}2$-microglobulin(${\beta}2$-MG) and microalbumin as biochemical markers of renal function and damage in 29 male workers exposed to organic solvents for more than five years and compared their results with those of 30 male office clerks as a reference group. Results : 1. The mean values of hemoglobin, hematocrit, SGOT, SGPT, ${\gamma}$-GTP were all within normal limits and there was no significant difference, except for hemoglobin(p<0.01), between exposed and reference group. 2. The values of BUN and serum creatinine were within reference limits and there was no significant difference between exposed and reference group. 3. The difference of mean values of urine microalbumin corrected by urine creatinine were statistically significant (p<0.01), but those of urine ${\beta}2$-MG was not. 4. There were no correlation of urine hippuric acids with BUN, serum creatinine, urine microalbumin and ${\beta}2$-MG. 5. There were no significant difference of BUN, serum creatinine, urine microalbumin and ${\beta}2$-MG upon work duration. Conclusions: It is assumed that chronic low-level organic solvent exposure in these workers shows early renal dysfunction, glomerular changes. The result corresponds to previous studies showing the relationship between hydrocarbon exposure and glomerulonephritis. For evaluation of impairment on kidney tubules, we need further study using more precise markers and long-term follow-up.

  • PDF

A Study on Site Positions for Monitoring Efficiency Improvements of the Aircraft Noise Monitoring Stations (항공기소음 자동측정국 감시효율 향상을 위한 위치설정에 대한 연구)

  • Son, Jung-Gon;Jeong, Woo-Hong;Hwang, Min-Gee;Gwon, Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.1
    • /
    • pp.50-55
    • /
    • 2009
  • The monitoring efficiency of the aircraft noise monitoring stations is decided to the reference noise level and the infringement of each monitoring stations. We calcurates the monitoring efficiency of three noise monitoring station among twelve in the vicinity of Gimpo Int'l Airport. As a result, the monitoring efficiency shows that the noise monitoring stations No#3, No#5 and No#6 are 14.3%, 18.5% and 29.3% respectively, Among them No#6 staion looks higher efficiency than another two stations because of underneath the flight trackas.