• Title/Summary/Keyword: no-insulation

Search Result 305, Processing Time 0.023 seconds

A Study on the Application of Finishing Materials According to the Locational Function of the Chapel in Church Space (교회공간 예배실의 위치적 기능에 따른 마감재 적용 연구)

  • Yeo, Mi;Lee, Chang No
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.1
    • /
    • pp.178-188
    • /
    • 2015
  • This study has the main objective of being of help as a reference data for the application of the finishing materials when designing the interior of the chapel of the church space through analysis of the finishing materials against the chapels of church space which has complex function. As precedent studies for this, the composition of the function and concept of the church space was surveyed and the complex function of the church space was surveyed. The theoretical surveyed was performed according to the casual composition, behavior of the community and role and location of the duties of the church members. The case objects were 10 chapels constructed by 5 professional interior design companies. The content of the analysis was the finishing materials in the chapels and their application characteristics. The detailed considerations to be referred to when designing the interior of the chapels of church space in the future were proposed. The analysis result of the application of the finishing materials according to the locational function of the chapels of church space can be explained as follows. First, the platform area was the characteristic of applying finishing materials which induce visual immersion. As for the floor materials in the platform, in order to minimize the floor sound and vibration phenomenon occurring during movements, noise insulation and dust protection rubber sheet was place and on top of it the floor or the carpet was placed. Second, the Choir area had the difficult problem of having to consider the appropriate sound absorption occurring due to the proliferation of sound and performance of classical instruments at the same time. However, in the case, this problem was solved through the sculptures of convex shape. Third, since the scheelite is a space where many people move around, the finishing material which absorbs sound was mainly used. Fourth, the entrance area was composed of thick wall materials compared to other walls, and the sound absorption character was most significantly considered when applying the finishing material. Fifth, the broadcasting room was composed either in independent type or an open type and performed its function and the main finishing materials was transparent glass which was highest use frequency.

Analysis Method for Damage Patterns of Low Voltage Switches for PL Judgment (PL 판정을 위한 저압용 스위치의 소손 패턴 해석기법)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.136-141
    • /
    • 2010
  • The purpose of this study is to examine the structure and heat generation mechanism of low voltage switches used to turn on or off the power supply to an indoor lighting system and investigate how the fixtures and movable contacts of the switches are damaged depending on the types of energy sources in order to secure the judgment base for expected PL disputes. Based on the Korean Standard (KS) testing method for incombustibility, this study applied a general flame to the switch. In addition, current was supplied to the switch using the PCITS (Primary Current Injection Test System). The ambient temperature and humidity were maintained at $22{\pm}2^{\circ}C$ and 40~60% respectively while performing the test. It is thought that the switch generated heat due to a defective connection of the wire and clip, insulation deterioration and defective contact of the movable contact, etc. The surface of the switch damaged by the general flame was uniformly carbonized. When the flame source was removed, the fire on the switch was extinguished naturally. From the result obtained by disassembling the switch carbonized by the general flame, it could be seen that fixtures and movable contacts remained in comparatively good shape but the enclosure, clip support, movable contact, indicating lamp, etc. showed carbonization and discoloration. In the case of the switch damaged by overcurrent, the clip connecting the wires, clip support, etc. showed almost no trace of damage, but the fixtures, movable contact, indicating lamp, etc. were severely carbonized. That is, the sections with high contact resistance were intensively damaged and showed a damage pattern indicating that carbonization progressed from the inside to the outside. Therefore, it is possible to judge the initial energy source by analyzing the characteristics of the carbonization pattern and the metal fixtures of damaged switches.

A Study on Fire Performance Evaluation of EIFS on Anti-Flaming Finish by Cone Calorimeter Test (콘칼로리미터에 의한 외단열시스템의 방염 화재성능평가를 위한 연구)

  • Min, Se-Hong;Sun, Ju-Seok;Kim, Sang-Chul;Choi, Yong-Mook;Lee, Seok-Ki
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.106-111
    • /
    • 2012
  • In this study, EIFS (Exterior insulation finish system) of exterior cladding was applied Cone calorimeter test to confirm the effect of flame retardant. As a results, the initial ignition points in accordance with the coated form and concentration of the flame retardant was delayed. But flame resistant treatment of EIFS cladding to control the fire will not affect confirmed that. In addition, EIFS that uses high-density and low-density due to difference in the density of the impact of the fire was no difference. The exterior of the ignition experiment occurred before and after 40 seconds, heat release rate to 100 seconds appears to occur about 90 % compared with the other exterior wall materials, the initial fire spread very fast was confirmed. EIFS cladding in order to prevent the spread of fire in the application of EIFS legally use is limited by the use of the building. And flame spread can be prevented, such as a vertical outer wall compartment measures are urgently needed.

Overview of Technology for Fixation of Carbon Dioxide Using Microalgae (미세조류를 이용한 이산화탄소 고정화 기술 현황)

  • Jeon, Seon-Mi;Kim, In Hae;Ha, Jong-Myung;Lee, Jae-Hwa
    • Applied Chemistry for Engineering
    • /
    • v.19 no.2
    • /
    • pp.145-150
    • /
    • 2008
  • In this work we have studied the antifouling properties of the hydrophobic sol-gel modified sensing membrane and its optical properties for sensor application. E. coli JM109, B. cereus 318 and P. pastoris X-33 were cultivated in confocal cultivation dishes with glass surface, respectively. The glass surface was coated with the hydrophobic sol-gels prepared by the dimethoxy-dimethyl-silane (DiMe-DMOS) and tetramethyl-orthosilicate (TMOS). After cultivation, microorganisms adhered on the surface coated with sol-gels and glass surface were dyed by gram-staining method and the numbers of microorganisms were analyzed based on the image data of the scanning electronic microscope (SEM). A great number of microorganisms, about $2{\sim}3{\times}10^4/mm^2$, was adhered on the glass surfaces which no hydrophobic sol-gels were coated. But, the antifouling effect of the hydrophobic sol-gels was large, that microorganisms of less than $200{\sim}300/mm^2$ were adhered on the coated glass surface. The performance of the sensing membranes for detection of pH and dissolved oxygen was enhanced by recoating the light insulation layer prepared with the mixture of the hydrophobic sol-gel and graphite particles.

A Study on Microorganisms Antifouling and Optical Properties of the Sensing Membrane Surface Modified by Hydrophobic Sol-gels (소수성 졸-겔로 개질된 센서 막 표면의 미생물 비점착과 광학 특성 연구)

  • Kim, Sun-Yong;Rhee, Jong Il
    • Applied Chemistry for Engineering
    • /
    • v.19 no.2
    • /
    • pp.222-227
    • /
    • 2008
  • In this work we have studied the antifouling properties of the hydrophobic sol-gel modified sensing membrane and its optical properties for sensor application. E. coli JM109, B. cereus 318 and P. pastoris X-33 were cultivated in confocal cultivation dishes with glass surface, respectively. The glass surface was coated with the hydrophobic sol-gels prepared by the dimethoxy-dimethyl-silane (DiMe-DMOS) and tetramethyl-orthosilicate (TMOS). After cultivation, microorganisms adhered on the surface coated with sol-gels and glass surface were dyed by gram-staining method and the numbers of microorganisms were analyzed based on the image data of the scanning electronic microscope (SEM). A great number of microorganisms, about $2{\sim}3{\times}10^4/mm^2$, was adhered on the glass surfaces which no hydrophobic sol-gels were coated. However, the antifouling effect of the hydrophobic sol-gels was large, that microorganisms of less than $200{\sim}300/mm^2$ were adhered on the coated glass surface. The performance of the sensing membranes for detection of pH and dissolved oxygen was enhanced by recoating the light insulation layer prepared with the mixture of the hydrophobic sol-gel and graphite particles.

A Study on Coupling Coefficient Between Rail and Reinforcing Bars in Concrete Slab Track (콘크리트 슬래브궤도에서 레일과 철근 사이의 결합계수에 대한 연구)

  • Kim, Min-Seok;Lee, Sang-Hyeok;Lee, Jong-Woo
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.3
    • /
    • pp.405-411
    • /
    • 2009
  • Railway signaling system in a rapid transit using the ATC system the approved a speed limit to a train and a part of signaling system in a metro approved a distance which is possible to move. Referring to the way of transmitting train control information, there are the one transmitting it to the on-board system of a train using the direct track, the another transmitting it establishing an instrument, and the other transmitting an instrument by a railway track. The one is the method using the direct track as a conductor for composing the part of the track and attaining the information controlling a train by transmitting a signal to the track. It is used for the high-speed railway and the subway. The method using the track attains information by transmitting it to returned information, and the on-board system of a train attains it by magnetic coupling. Because many reinforcing bars on the concrete slab track are used, interaction between a rail and a reinforcing bar that is not produced on ballast track is made. Due to the interaction, the electric characteristic of rail is changed. In the current paper, we numerically computed the coupling coefficient between the rail and the reinforcing bar based on the concrete slab track throughout the model related to the rail and the reinforcing bar using the concrete slab track that is used in the second interval of the Gyeongbu high-speed railway, and we defined the coupling coefficient not changed in the electric characteristic of rail in the condition that there is no interaction between the rail and the reinforcing bar.

Effects of Ondol Sleep Environment on the Thermo-physiological Response of the Human Body (온돌 수면환경이 인체의 온열생리반응에 미치는 영향)

  • Kim, Jung-Sook;Sung, Su-Kwang
    • Fashion & Textile Research Journal
    • /
    • v.1 no.2
    • /
    • pp.173-181
    • /
    • 1999
  • The purpose of this study was to investigate actual sleeping environments in Ondol rooms depending on the season. The experiment was performed on five healthy women. The bedroom environments using Ondol were measured in five cases (three apartments and two houses). The environments in bedroom, bedding temperature, skin temperature and thermal sensation were measured continuously through the seven days for each season in real life. This data of sleeping environments were analyzed in the view of seasonal variations and housing types. Annual average bedroom temperatures: $26.2{\sim}31.0^{\circ}C$ in apartments, $15.7{\sim}33.6^{\circ}C$ in houses. Annual average bedroom humidity: 48.3~82.1% RH in apartments, 64.9~87.0% RH in houses. During sleeping, temperatures of contact surfaces like sheets and under quilts ranged between $30.5^{\circ}C$ and $34.1^{\circ}C$ regardless of season or housing type. Annual average rectal temperature was $36.8^{\circ}C$ with no significant difference in season or housing type. In the point of thermal sensation, neutral temperature of the bedroom was $25.9^{\circ}C$ in apartments and $20.3^{\circ}C$ in houses. It was concluded that in spite of thermal environmental variations according to the seasons, skin, bedding and bedroom temperatures in apartments were better and more stable than those of houses. It is regarded that while houses are brick structured, apartments are steel-frame structured. Due to better insulation and air tightness, apartments were affected less from outdoor temperature and maintained higher room temperature than houses.

  • PDF

Credibility of a Newly Developed Sham Moxibustion (피부 열전도 온도에 근거를 둔 거짓 뜸 개발 및 평가 연구)

  • Jang, Min-Ki;Yoon, Eun-Hye;Jung, Chan-Yung;Byun, Hyuk;Kim, Eun-Jung;Kim, Kyung-Ho;Kim, Kap-Sung;Lee, Seung-Deok
    • Journal of Acupuncture Research
    • /
    • v.27 no.1
    • /
    • pp.117-127
    • /
    • 2010
  • Background : To demonstrate the efficacy of moxibustion therapy, randomized controled trials are required. But, clinical trials of moxibustion had limitations due to the absence of a sham moxibustion model for an appropriate placebo. Objectives : To develop a new sham moxibustion model based on the thermal characteristics of commercial indirect moxibustion, especially temperature, and to evaluate whether it could be applied in clinical trials. Methods : By applying heat insulation, we created a sham moxibustion device that was indistinguishable from a real one with the naked eye. It also stimulated heat but had inert remedial value. A clinical trial was performed on subjects to test double blinding. The subjects were randomly assigned into two groups, a treatment group and a sham group. Acupoint Zusanli($ST_{36}$) was used in each group for 3 times. A sham acupuncture credibility questionnaire was modified into a moxibustion credibility questionnaire and was filled out after treatment. Results : No major difference was detected in the subjects' baseline data. Most subjects and practitioners could not distinguish the sham moxibustion device from the real one. But, subjects who had experience of moxibustion therapy more likely to distinguish the sham moxibustion device from the real one than subjects who didn't have experience of moxibustion therapy. The treatment group showed a significant difference in the VAS(Visual Analog Scale) for intensity of sensation during treatment than that of the sham group. Conclusions : The sham moxibustion device in this study is proved sufficient and credible to be applied in investigations of the effect of moxibustion. But it is more appropriate for the people who don't have experience of moxibustion therapy.

The Development of the Simple SHGC Calculation Method in Case of a Exterior Venetian Blind Using the Simulation (시뮬레이션을 이용한 외부 베네시안 블라인드의 약식 SHGC 계산법 개발)

  • Eom, Jae-Yong;Lee, Chung-Kook;Jang, Weol-Sang;Choi, Won-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.2
    • /
    • pp.73-83
    • /
    • 2015
  • When it comes to these buildings for business use, cooling load during summertime was reported to have great importance which, as a result, impressively increased interest in Solar Heat Gain Coefficient (SHGC). Such SHGC is considered to be lowered with the help of colors and functions of glass itself, internal shading devices, insulation films and others but basically, these external shading devices for initial blocking that would not allow solar heat to come in from outside the buildings are determined to be most effective. Of many different external shading devices, this thesis conducted an analysis on Exterior Venetian Blind. As for vertical shading devices, previous researches already calculated SHGC conveniently using concepts of sky-opening ratios. However in terms of the Venetian Blind, such correlation is not possibly applied. In light of that, in order to extract a valid correlation, this study first introduced a concept called shape factor, which would use the breadth and a space of a shade, before carrying out the analysis. As a consequence, the concept helped this study to find a very similar correlation. Results of the analysis are summarized as follows. (1) Regarding SHGC depending on the surface reflectance of a shade, an average of 2% error is observed and yet, the figure can always be ignored when it comes to a simple calculation. (2) As for SHGC of each bearing, this study noticed deviations of 4% or less and in the end, it is confirmed that extraction can be achieved with no more than one correlation formula. (3) When only the shape factor and nothing else is used for finding a correlation formula, the formula with a deviation of approximately 5% or less is what one would expect. (4) Since the study observed slight differences in bearings depending on ranges of the shape factors, it needed to extract a weighted value of each bearing, and learned that the smaller the shape factor, the wider the range of a weighted value. The study now suggests that a follow-up research to extract a simple calculation formula by dealing with all these various inclined angles of shade, solar radiation conditions of each region (the ratio of diffuse radiation to direct radiation and others) as well as seasonal features should be carried out.

A Field Survey on the Odor Concentration in Piggery by the Change of the Season (돈사 내에서 계절별 악취 발생 농도 조사 연구)

  • Kam, D.H.;Jeong, J.W.;Choi, H.C.;Song, J.I.;Hong, J.T.;Lee, D.W.;Yoo, Y.H.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.3
    • /
    • pp.187-194
    • /
    • 2007
  • Six pig farms were surveyed to measure the odor concentrations and characteristics of ammonia and sulfide corollary compounds in piggery. They were depended on the scale of piggery, weather conditions such as temperature, humidity, wind speed and direction, scales and types of pig breeding, and manure treatment methods. The highest ammonia concentrations in piggery were measured during the winter, since the tight sealed insulation in piggery made less amount of generated ammonia discharged from piggery. The objective of this study was to measure concentrations of odor in the piggery by season and growing, and to measure concentrations of odor at boundary area. So, we investigated the raising managements, manure managements, and methods of reducing odor according to farm scale. We found that concentration of ammonia gas in the swine fattening piggery in winter was the highest. This result is consistent with the lower ventilation rate to maintain Indoor temperature. In this result, there was no connection between farm scale and ventilating system. Concentration of ammonia gas was 1.64 ppm at one boundary area in the middle scale. $H_2S$, $CH_3SH$, $(CH_3)_2S$, and $(CH_3)_2S_2$ were below the standard of protection odor policy.

  • PDF