• 제목/요약/키워드: nm23

검색결과 950건 처리시간 0.03초

Effect of Ni Interlayer on the Methanol Gas Sensitivity of ITO Thin Films

  • Lee, Y.J.;Huh, S.B.;Lee, H.M.;Shin, C.H.;Jeong, C.W.;Chae, J.H.;Kim, Y.S.;Kim, Daeil
    • 열처리공학회지
    • /
    • 제23권5호
    • /
    • pp.245-248
    • /
    • 2010
  • Sn doped $In_2O_3$ (ITO) and ITO/Ni/ITO (INI) multilayer films were deposited on the glass substrates with a reactive magnetron sputtering system without intentional substrate heating and then the influence of the Ni interlayer on the methanol gas sensitivity of ITO and INI film sensors were investigated. Although both ITO and INI film sensors have the same thickness of 100 nm, INI sensors have a sandwich structure of ITO 50 nm/Ni 5 nm/ITO 45 nm. The changes in the gas sensitivity of the film sensors caused by methanol gas ranging from 100 to 1000 ppm were measured. It is observed that the INI film sensors show the higher sensitivity than that of the ITO single layer sensors. Finally, it can be concluded that the INI film sensor have the potential to be used as improved methanol gas sensors.

수직자기이방성을 갖는 [Pd/Co] Spin Valve 구조에서 자기저항효과 (Magnetoresistance Effect of [Pd/Co] Spin-valve with Perpendicular Anisotropy)

  • 최진협;이기암
    • 한국자기학회지
    • /
    • 제16권3호
    • /
    • pp.173-177
    • /
    • 2006
  • 수직자기이방성을 갖는 [Pd/Co] 다층박막으로 구성된 스핀밸브 구조에서 비자성층(space layer, SL) Pd 또는 Cu의 두께와 다층박막의 반복층수 N에 따른 자기저항효과의 의존성을 연구하였다. 비자성층을 Pd보다 Cu로 사용하였을 때 더 큰 자기저항비를 얻었다. 그리고 Cu층과 고정층 사이에 Co층을 삽입하는 경우 약 3배가량 자기저항비가 증가하는 것을 관찰하였다. $Ta_{(2.1nm)}/[Pd_{(0.61)}/Co_{(0.23)}]_4/Cu_{(2.37)}/Co_{(t)}/[Pd_{(0.61)}/Co_{(0.23)}]_2/FeMn_{(10.6)}/Ta_{(2.1)}$ 구조에서 삽입된 Co층의 두께가 0.62nm 또는 1.01nm에서 최대의 자기저항비 7.4%를 얻었다.

편광모드 회전을 이용한 WDM 광 네트워크용 Ti:PPLN Šolc-형 집적광학 파장필터에 관한 연구 (Ti:PPLN Šolc-type Integrated Optical wavelength filters utilizing polarization-mode conversion for WDM optical networks)

  • 정홍식
    • 한국인터넷방송통신학회논문지
    • /
    • 제9권4호
    • /
    • pp.161-168
    • /
    • 2009
  • 16.6${\mu}m$ 주기로 리튬나오베이트 Ti 확산 채널광도파로를 분극반전 시킨 Ti:PPLN을 이용해서 편광모드변환을 기반으로 하는 $\check{S}$olc-형 파장필터를 구현하여, 실험적으로 투과 광 스펙트럼을 측정하였다. 중심파장 1272.49nm에서 투과 스펙트럼이 관찰되었으며, 투과 스펙트럼의 선폭(FWHM)과 부모드 레벨이 각각 0.23nm and 7dB로 측정되었다.

  • PDF

피라졸 유도체를 함유한 폴리알킬플루오렌 공중합체의 향상된 EL 특성 (Highly Enhanced EL Properties of PF Copolymers with Pyrazole Derivatives)

  • 강인남;이지훈
    • 한국전기전자재료학회논문지
    • /
    • 제23권7호
    • /
    • pp.539-544
    • /
    • 2010
  • We have synthesized new blue electroluminescent polyalkylfluorene-based copolymers [poly(F-co-Py)x:y, where x:y = 99:1 or 95:5 mole ratios] containing the hole-injecting pyrazole derivative [3,3'-(4,6-bis(octyloxy)-1,3-phenylene)bis(1,5-diphenyl-4,5-dihydro-1H-pyrazole] through Ni(0) mediated polymerization, and their electroluminescent properties were investigated. Electroluminescent (EL) devices were fabricated with ITO / PEDOT:PSS (110 nm) / copolymers or PF homopolymer (80 nm) / Ca (50 nm) / Al (200 nm) configuration. Each EL device constructed from the copolymer exhibited significantly enhanced brightness and efficiency compared with a device constructed from the PF homopolymer. The EL device constructed with poly(F-co-Py)99:1 exhibited the highest luminous efficiency and brightness (0.95 cd/A and $2,907\;cd/m^2$, respectively). The achieved luminous efficiency was an excellent result, providing almost a 4-fold improvement on the efficiency obtainable with the a PF homopolymer device. This enhanced efficiency of the copolymer devices results from their improved hole injection and more efficient charge carrier balance, which arises from the HOMO level (~5.83 eV) of the poly(F-co-Py)99:1 copolymer, which is higher than that of the PF homopolyme (~5.90 eV).

연소합성법으로 제작한 ZnGa2O4 나노형광체의 광학적 특성 (Photoluminescence Characteristics of ZnGa2O4 Nano-phosphors by Combustion Method)

  • 김세준;최형욱
    • 한국전기전자재료학회논문지
    • /
    • 제23권1호
    • /
    • pp.14-17
    • /
    • 2010
  • $ZnGa_2O_4$ powder were prepared by combustion method and $Mn^{2+}$ ions, a green luminescence activator, and $Cr^{3+}$ ions, a red luminescence activator were separately doped into $ZnGa_2O_4$. The characteristics of the synthesized nano powder were investigated by means of X-ray diffraction (XRD), Scanning Electron Microscope (SEM), and photoluminescence (PL). The various $ZnGa_2O_4$ peaks, with the (311) main peak, appeared at all sintering temperature XRD patterns. The PL specctrums of $ZnGa_2O_4$ powder showed main peak of 425 nm, and maximum intensity at the sintering temperature of $1200^{\circ}C$. SEM images shown that nano sized particles(about 200 nm) were of spherical shape. The characteristics of $ZnGa_2O_4$ containing 0.004 mol $Mn^{2+}$(505 nm, green) and $ZnGa_2O_4$ containg 0.002 mol $Cr^{3+}$ (696 nm, red) were shown to be the best.

Zinc tin oxide 투명박막트랜지스터의 특성에 미치는 열처리 효과 (Thermal treatments effects on the properties of zinc tin oxide transparent thin film transistors)

  • 마대영
    • 전기전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.375-379
    • /
    • 2019
  • Zn와 Sn의 원자비가 2:1인 타겟을 고주파 스파터링하여 $ZnO-SnO_2(ZTO)$박막을 증착하고 열처리에 따른 구조적 특성변화를 조사하였다. 이 ZTO박막을 활성층으로 사용하여 투명박막트랜지스터(TTFT)를 제조하였다. 약 100 nm 두께의 $SiO_2$위에 100 nm의 $Si_3N_4$막을 기른 후 TTFT의 게이트 절연막으로 채택하였다. TTFT의 전달 특성을 통해 이동도, 문턱전압, 작동전류-차단전류 비($I_{on}/I_{off}$), 계면트랩밀도를 구하였다. 기판 가열 및 후속 열처리가 ZTO TTFT의 특성 변화에 미치는 영향을 분석하였다.

연소실 진단을 위한 LIBS 소형화 장비 개발 (Development of LIBS Plug for Combustor Diagnosis)

  • 전형민;김현우;여재익
    • 한국추진공학회지
    • /
    • 제23권2호
    • /
    • pp.53-59
    • /
    • 2019
  • 연소실 내부의 연료 분포를 실시간으로 측정하는 목적을 가진 소형화 장비인 LIBS plug가 개발 및 제작 되었다. LIBS plug는 레이저 유도 플라즈마 분광분석법 (Laser-induced breakdown spectroscopy : LIBS)를 응용한 장비로, 기존의 LIBS 결과인 전체 스펙트럼에서 당량비와 깊게 관여하는 두 개의 파장(H: 656.3 nm, O: 777 nm)만을 선정하여 측정할 수 있도록 하였다. 렌즈와 밴드패스 필터, 포토다이오드로 구성된 본 장비로 수집한 결과에 대한 분석이 이루어졌으며, 액체(가솔린)와 기체(LPG) 연료와 공기의 혼합물에서의 당량비 측정이 이루어졌다.

암석분광반사율 특성을 이용한 납석 광화대 추출 (Extraction of Pyrophyllite Mineralized Zone using Characteristics of Spectral Reflectance of Rock Samples)

  • 지광훈;이홍진
    • 대한원격탐사학회지
    • /
    • 제23권6호
    • /
    • pp.493-500
    • /
    • 2007
  • 일반적으로 분광측정을 수행함에 있어서 측정 대상물, 측정 방법, 측정 조건 등에 따라서 측정 결과가 상이하게 나타난다. 본 연구에서는 광물 및 암석 샘플의 전처리, 센서와 대상물과의 거리에 대한 표준화 방법을 제시하고, 납석의 분광특성 연구를 수행하였다. 광물, 암석 샘플의 크기는 노두의 규모와 상태에 따라서 다양하기 때문에 샘플과 센서간의 거리를 일정하게 유지하는 것이 중요하다. 표준화를 수행하기 전에 동일한 암석(석영반암)에 대해서 자연석, 자갈, 분말 그리고 절단암 등 다양한 샘플을 준비하였다. 샘플의 표면 상태와 그림자의 영향을 최소화하고 정량적인 분석을 위하여 센서와 샘플간의 거리를 30cm로 유지하고 $1{\sim}2cm$ 두께의 절단암을 3회 반복 측정하였다. 제안된 방법을 검증하기 위해서 납석에 대한 사례 연구를 수행하였다. 본 연구결과에 따르면 납석은 1.406nm, 1,868nm, 2.180nm 그리고 2.180nm 파장대역에서 강한 흡수 양상을 보이며, 특히 1.406nm와 2.180nm 파장대역에서 강한 흡수가 일어난다. 이러한 흡수 특징은 Landsat TM 영상의 밴드 7과 ASTER 영상의 밴드 8과 일치한다. 따라서, 이러한 결과를 이용하여 육안으로 구분되지 않은 다른 대상물(나지, 주차장, 채석장 등)과 납석 광산을 구분할 수 있다.

FTP-75, WLTC 시험 모드에서 LPG, CNG 자동차의 배출가스 및 PN 비교 (Comparing Exhaust Gas Emission and PN in LPG and CNG Vehicle under FTP-75 and WLTC Test Mode)

  • 장진영;이영재;권오석;김정환
    • 한국가스학회지
    • /
    • 제20권6호
    • /
    • pp.9-15
    • /
    • 2016
  • 가스연료인 LPG와 CNG는 청정 대체연료로서 차량용 연료로 많이 사용되고 있다. 특히 CNG의 경우 저탄소 연료로서 온실가스 배출량 저감에 기여할 수 있다, LPG의 경우 가솔린 차량과 거의 동등한 성능을 가지면서도 연료가격이 저렴하여 택시에 많이 사용되고 있다. 본 연구에서는 동일차량에서 LPG와 CNG를 사용하여 배출가스와 최근 문제가 되고 있는 입자상물질의 배출개수(PN; particle number)에 대하여 비교하였다. 차대동력계를 이용하여 FTP-75와 WLTC 모드에 대하여 시험을 진행하였다. PN은 두 대의 CPC(Condensation Particle Counter)를 이용하여 5 nm 이상과 23 nm 이상의 입자에 대하여 배출 개수를 측정하였다. 배출가스에 있어서는 CO2의 경우 LPG 차량이, 메탄의 경우 CNG 차량이 많이 배출되었다. PN의 경우 두 연료에서 배출되는 PN은 비슷한 수준이었으며, WLTC 에서 고속운전하는 동안 23 nm 이하 크기의 입자 배출 개수가 많았다.

새로운 청광 분석법을 적용한 MR8 안경재료의 광학적 시험 평가 (Optical Evaluation of MR8 Material spectacle Lens with a New Method for the Analysis of Blue Light)

  • 김하림;정주현
    • 대한시과학회지
    • /
    • 제20권4호
    • /
    • pp.413-420
    • /
    • 2018
  • 목적 : MR8 로 제조된 안경렌즈에서 굴절력별로 나누어 투과율을 측정하여 광학적 시험 및 청광 영역을 David L.의 분석법을 적용하여 분석하였다. 방법 : 시중에서 판매되고 있는 MR8 로 제조된 -8.00D, -7.00D, -6.00D, -5.00D, -4.00D, -3.00D, 0.00D의 렌즈를 선정하여 UV-VIS Spectrophotometers(SolidSpec 3700)로 200~1000nm까지 5nm 간격으로 투과율을 측정하고, 청광영역(380~500nm)을 David L.의 청광분석 방법을 적용하여 분석하였다. 결과 : 연구에 선정한 MR8렌즈들 모두 UV영역을 거의 모두 차단하였다. -8.00D의 렌즈가 청광영역에서 투과율 59.56%로 가장 낮게 측정되었고 또한, David L. 분석에 따른 청광영역1과 2에서 낮은 값이 측정되었다. 적외선 영역에서는 모든 렌즈의 투과율이 점진적으로 감소하였다. 그리고 시감투과율에서 평균 23.67%~26.33%의 계산값을 얻었고 -4.00D부터 점진적으로 감소하였다. 결론 : David L.의 분석법을 적용하면, 청광 1영역에서는 최소 41.28%, 최대 46.60%가 측정되었으며, 청광 2영역에서는 최소 87.30%, 최대 97.55%가 측정되었다. 그리고 청광 3영역에서는 최소 86.83%, 최대 96.55%가 측정되었으며 평균 94%였다. 시감투과율에서는 측정된 렌즈 중 -3.00D렌즈가 26.33%으로 가장 높은 값이 계산되었으며, -8.00D렌즈가 23.67%으로 가장 낮은 계산 값을 얻었다.