• Title/Summary/Keyword: nirS

Search Result 303, Processing Time 0.03 seconds

Quantitative distribution of denitrifying bacteria with nirS and nirK in MLE and A/O process (MLE와 A/O 공정에서의 nirS 와 nirK 를 가진 탈질미생물의 정량적 분포)

  • Lim, Dong-Seok;Kim, Yun-Jung;Kim, Hyung-Gun;Park, Seung-Guk;Chung, Tai-Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.4
    • /
    • pp.591-598
    • /
    • 2012
  • Denitrification is an important biological mechanism in wastewater treatment process because this process is technically to remove nitrogen from water to air. There have been lots of study about denitrification engineering and molecular biological research about denitrifying bacteria, respectively. However, combination of these researches was unusual and rare. This study is about the correlation between quantity of denitrifying bacteria and denitrification potential, and consists of NUR batch test as analysis method of denitrification potential and quantitative molecular analysis for denitrifying bacteria. Three reactors (A/O, MLE and A/O of nitrogen deficiency) are operated to get activated sludge with various denitrification potential. All samples which were acquired from reactors were measured denitrification potential by NUR test and NUiR test. Also, Real-time PCR was conducted for quantification of denitrifying bacteria composition in activated sludge. The various denitrification potentials were measured in the reactors. The denitrifiaction potential was the highest in MLE process and the reactor of the nitrogen deficiency showed the lowest. Genomic DNA of activated sludge was obtained and consequently, real-time PCRuse the primer sets of nirK and nirS were conducted to quantify genes involving denitrification reductase production. As the result of real-time PCR, nirK gene showed more significant influence on denitrification potential comapred with nirS gene.

Determination of Water Content in Skin by using a FT Near Infrared Spectrometer

  • Suh Eun-Jung;Woo Young-Ah;Kim Hyo-Jin
    • Archives of Pharmacal Research
    • /
    • v.28 no.4
    • /
    • pp.458-462
    • /
    • 2005
  • The water content of skin was determined using a FT near infrared (NIR) spectrometer. NIR diffuse reflectance spectra were collected from hairless mouse, in vitro, and from human inner arm, in vivo. It was found that the variation of NIR absorbance band 1450 nm from OH vibration of water and 1940 nm from the combination involving OH stretching and OH deformation, depending on the absolute water content of separated hairless mouse skin, in vitro, using the FT NIR spectrometer. Partial least squares regression (PLSR) was applied to develop a calibration model. The PLS model showed good correlation. For practical use of the evaluation of human skin moisture, the PLS model for human skin moisture was developed in vivo on the basis of the relative water content of stratum corneum from the conventional capacitance method. The PLS model predicted human skin moisture with a standard errors of prediction (SEP) of 3.98 at 1130-1830 nm range. These studies showed the possibility of a rapid and nondestructive skin moisture measurement using FT NIR spectrometer.

A Rapid Quantitative Assay of Intact Ambroxol Tablets by FT-NIR Spectroscopy

  • Kim, Do-Hyung;Ah, Woo-Young;Kim, Hyo-Jin
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.213.2-213.2
    • /
    • 2003
  • A simple analytical procedure using FT-NIR for the rapid determination of individual ingredients was evaluated. Direct measurements were made by reflection using a reflectance accessory, by transmittance using tablet accessory and turn table. FT-NIR spectral data were transformed to the first derivative. Partial Least Square Regression(PLSR) was applied to quantify near-infrared (NIR) spectra of 2 ingredients. These calibration models were cross-validated (leave-one-out approach). The prediction ability of the models was evaluated on ambroxol tablets and compared with the real values in manufacturing procedure. (omitted)

  • PDF

Quantification of Skin Moisture in Hairless Mouse by using a Portable NIR System and a FT NIR Spectrometer (Photo Diode Array형의 휴대용 근적외 분광기와 FT 근적외 분광기를 이용한 Hairless Mouse 피부 수분 정량)

  • Suh, Eun-Jung;Woo, Young-Ah;Kim, Hyo-Jin
    • YAKHAK HOEJI
    • /
    • v.49 no.2
    • /
    • pp.115-121
    • /
    • 2005
  • In this study, the performance of a portable NIR system and a FT NIR spectrometer were compared to determine water content of hairless mouse skin. The stratum corneum parts wer e separated from the epidermal tissues by trypsin solution. NIR diffuse reflectance spectra of hairless mouse skin were acquired using a fiber optic probe. In the near infrared, water molecules show two clear absorption bands at 1450 nm from first overtone of O-H stretching and 1940 nm from the combination involving O-H stretching and O-H deformation. It was found that the variations of O-H absorption band according to water content. Partial least squares regression (PLSR) was applied to develop a calibration model. The PLS model showed a good correlation between NIR predicted value and the absolute water content of separated hairless mouse skin, in vitro. For both the portable and the FT NIR spectrometer, These studies showed the possibility of a rapid and nondestructive skin moisture measurement using NIR spectroscopy. The portable NIR spectrometer with a photodiode arrays-microsensor could be more rapidly applied for the determination of water content with comparable accuracy with the performance of a FT spectrometer .

Determination of water content in alcohol by portable near infrared (NIR) system (휴대용 분광분석기를 이용한 알코올 중에 함유되어 있는 물의 측정)

  • Ahn, Jhii-Weon;Woo, Young-Ah;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.95-101
    • /
    • 2003
  • In this study, water content in the mixture of methanol and ethanol was nondestructively measured by near infrared (NIR) spectroscopy. Two types of NIR instruments, portable NIR system with a photo-diode array and scanning type NIR spectrometer were used and the calibration results were compared. Partial least squares regression (PLSR) was applied for the calibration and validation for the quantitative analysis. The calibration results from both instruments showed good correlation with actual values. The calibration with the use of PLS model predicted water concentration with a standard error of prediction (SEP) of 0.10% and 0.12% for photo diode array and scanning type, respectively. During 6 days, routine analyses for 3%, 5% and 7% water in ethanol solution with 2% methanol were performed to validate the robustness of the developed calibration model. The routine analyses showed good results with coefficient of variation (CV) of within 3% for both types of NIR spectrometers. This study showed that the rapid determination of water in the mixture of methanol and ethanol was successfully performed by NIR spectroscopy and the performance of the portable NIR system with a photo diode array detector was comparable to that of the scanning type NIR spectrometer.

Quantification of Naproxen in Pharmaceutical Formulation using Near-Infrared Spectrometry (근적외 분광분석법을 이용한 나프록센 정제의 정량분석)

  • Kim Do Hyung;Woo Young Ah;Kim Hyo Jin
    • YAKHAK HOEJI
    • /
    • v.49 no.1
    • /
    • pp.1-5
    • /
    • 2005
  • Near-infrared (NIR) spectroscopy has been widely applied in various field, since it is nondestructive and no sample preparation is required. In this paper, NIR spectroscopy was used for the determination of naproxen in a commercial pharmaceutical preparation. NIR spectroscopy was used to determine the content of naproxen in intact naproxen tablets containing 250 mg ($65.8\%$ nominal concentration) by collecting NIR spectra in the range of $1100{\sim}1750nm$. The laboratory-made samples had $46.1{\sim}85.5\%$ nominal naproxen concentration. The measurements were made by reflection using a fiber-optic probe and calibration was carried out by partial least square regression (PLSR). Model validation was performed by randomly splitting the data set into calibration and validation data set (63 samples as a calibration data set and 42 samples as a validation data set). The developed NIR calibration gave results comparable to the known values of tablets in a laboratorial manufacturing process with standard error of calibration (SEC) and standard error of prediction (SEP) of $1.06\%\;and\;1.04\%$, respectively. The NIR method showed good accuracy and repeatability. NIR spectroscopic determination in intact tablets allowed the potential use of real time monitoring for a running production process.

Materials Characterization Using A Novel Simultaneous Near-Infrared/X-ray Diffraction Instrument

  • Yeboah, S.Agyare;Blanton, Thomas;Switalski, Steve;Schuler, Julie;Analytical, Craig Barnes
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1288-1288
    • /
    • 2001
  • X-ray powder diffraction (XRD) is utilized for determination of polymorphism in crystalline organic materials. Though convenient to use in a laboratory setting, XRD is not easily adapted to in situ monitoring of synthetic chemical production applications. Near-Infrared spectroscopy (NIR) can be adapted to in situ manufacturing schemes by use of a source/detector probe. Conversely, NIR is unable to conclusively define the existence of polymorphism in crystalline materials. By combining the two techniques, a novel simultaneous NIR/XRD instrument has been developed. During material's analysis, results from XRD allow for defining the polymorphic phase present, and NIR data are collected as a fingerprint for each of the observed polymorphs. These NIR fingerprints will allow for the development of a library, which can be referenced during the use of a NIR probe in manufacturing settings.

  • PDF

Algorithm for Finding the Best Principal Component Regression Models for Quantitative Analysis using NIR Spectra (근적외 스펙트럼을 이용한 정량분석용 최적 주성분회귀모델을 얻기 위한 알고리듬)

  • Cho, Jung-Hwan
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.6
    • /
    • pp.377-395
    • /
    • 2007
  • Near infrared(NIR) spectral data have been used for the noninvasive analysis of various biological samples. Nonetheless, absorption bands of NIR region are overlapped extensively. It is very difficult to select the proper wavelengths of spectral data, which give the best PCR(principal component regression) models for the analysis of constituents of biological samples. The NIR data were used after polynomial smoothing and differentiation of 1st order, using Savitzky-Golay filters. To find the best PCR models, all-possible combinations of available principal components from the given NIR spectral data were derived by in-house programs written in MATLAB codes. All of the extensively generated PCR models were compared in terms of SEC(standard error of calibration), $R^2$, SEP(standard error of prediction) and SECP(standard error of calibration and prediction) to find the best combination of principal components of the initial PCR models. The initial PCR models were found by SEC or Malinowski's indicator function and a priori selection of spectral points were examined in terms of correlation coefficients between NIR data at each wavelength and corresponding concentrations. For the test of the developed program, aqueous solutions of BSA(bovine serum albumin) and glucose were prepared and analyzed. As a result, the best PCR models were found using a priori selection of spectral points and the final model selection by SEP or SECP.

Synthesis and Characterization of Pentarylene Bisimide Derivative as NIR Colorant (NIR Colorant용 Pentarylene Bisimide의 합성 및 특성 연구)

  • Baek, Kwan;Jeong, Yeon-Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.2
    • /
    • pp.140-146
    • /
    • 2012
  • A variety of dyes are commercially available today, there is an ongoing need for new chromophoric systems and low-band-gap materials. For example, near-infrared (NIR) emission has received increased attention for applications in bioassays and medicine while NIR absorption is demanded for laser-welding of plastics or efficient blocking of heat rays. Most of the commercially available NIR materials are not suitable for such purposes owing to their insufficient stability. We have developed a novel NIR-absorbing polyaromatic dye. By extending the system of perylenebis(dicarboximide)s along the molecular long axis, we have obtained the higher homologue pentarylenebis(dicarboximide). We have tried to introduce imide functional group to pentarylene in order to increase chemical and thermal stability.

Characterization of Denitrifier Community in Independent Anoxic Reactor Using Modified BAF Process (Modified BAF 공정을 이용한 독립적인 무산소조에서 탈질미생물 군집의 특성)

  • Park, Jeung-Jin;Jeung, Young-Rok;Yu, Jae-Cheul;Hur, Sung-Ho;Choi, Won-Seok;Byun, Im-Gyu;Lee, Tae-Ho;Park, Tae-Joo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.7
    • /
    • pp.752-756
    • /
    • 2006
  • The independent anoxic reactor was introduced in biological aerated filters as the regulation of water quality requirement, especially total nitrogen, had been strengthened. The process studied in this work was upflow $Biobead^{(R)}$ process which was used commercial invented for removal of organic materials and nitrification. For the purpose of evaluating the independent anoxic reactor, PCR-DGGE, of the molecular biological methods, was performed. Two types of nitrite reductase genes were selected. One is nirS represented cytocrome $cd_1$ nitrite reductase gene and the other is nirK represented Cu-containing nitrite reductase gene. Denitrifier community in the independent anoxic reactor was analyzed with PCR-DGGE using these two denitrifying functional genes. As the result of the PCR, only nirS gene was detected between nirS and nirK. With the result of the DGGE, specific bands became strong, as the operating days were longer, nitrate loading rate was increased. otherwise those of the initial activated sludge showed various bands. In the consequence of the sequence of DGGE bands, various denitrifiers were sequenced in the initial activated sludge, while specific denitrifiers like alcaligenes faecalis were predominant in the anoxic reactor. Consequently, introduction of the independent anoxic reactor made it possible to achieve 96% denitrification efficiency, and was proper for the modification of BAF process.