• Title/Summary/Keyword: nickel chloride

Search Result 115, Processing Time 0.022 seconds

SENSITIVITY TO NICKEL, COBALT, CHROME, & COFFER IN DENIAL ALLOYS (치과 보철물 합금 성분중 니켈, 코발트, 크롬 및 구리에 대한 감작률에 관한 조사 연구)

  • Park Young-Mi;Choi Dae-Gyun;Choi Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.2
    • /
    • pp.155-166
    • /
    • 1992
  • In dentistry, precious metal alloys are, mainly due to economic factors, increasingly displaced by alternatives containing Ni-Cr-Co. There are some reports where hypersensitive reactions to Ni-Cr-Co alloys are presented and discussed. The reactions reported vary from mucosa contact stomatitis to generalized dermatitis without any oral mucosal reaction. The purpose of this study was to investigate the incidence of nickel, chrome, cobalt and copper, and to know whether subjects with positive skin reaction to nickel would also demonstrate adverse intraoral reaction to a non-precious metal nickel. The patch tests were performed in 81 subjects(male 39, female 42) and nickel sulfate 5% aq., potassium bichromate 0.5% at., cobalt chloride 2% aq., & copper sulfate 1% aq., were used for test allergens. And then the intraoral tests were performed in 16 subjects, 8 subjects with positive allergic skin reaction to nickel and 8 subjects with negative allergic skin reaction. A pure metallic nickel plate was attached to the buccal side of the upper second premolar. The results are as follows : 1. The frequency of nickel sensitivity was 9.9% (2 men, 6 women), cobalt was 4.9% (1 man, 3 women), and chrome was 2.5% (2 men) respectively and there was no positive reaction to copper 2. The positive reactions were 8 of 23 (34.8%) with a history of jewelry allergic reactions and 3 of 58 (5.1%) without a history of jewelry allergic reactions. 3. Three of 8 subjects with positive skin reaction. gave reactions to the metal plates.

  • PDF

Real-time Internal Stress of Nickel Sulfamate Electroform (니켈쌀파메이트 전주층의 실시간 잔류응력)

  • Kim I.;Kang K.;Lee J.;Kwon S.C.;Kim M.;Lee J.Y.
    • Journal of the Korean institute of surface engineering
    • /
    • v.38 no.1
    • /
    • pp.14-20
    • /
    • 2005
  • The control of internal stress is extremely important in electroforming because of the deliberately low adhesion between the electro form and the mandrel. Excessive tensile or compressive stress can cause distortion, separation problem, curling, peeling or separation of electroform prematurely from the mandrel, buckling and blistering. Nickel sulfamate bath has been widely used in electroforming because of its low internal stress and moderate hardness. In this study, real-time stress sensor has been used for stress control in chloride-free nickel sulfamate bath for 400 mm x 300 mm x 500 ㎛ nickel electroform. It was found that compressive stress found at low current density indicated the contamination of electrolyte, which is very useful in procuring buckling and peeling of electroform. No compressive stress is allowed for plate electroform. The real-time stress can also be used for accurate stress control of nickel electroform. The tensile stress was found to be increased slightly with increase in nickel electroform thickness, i.e., from initial 1.47 ksi to 2.02 ksi at 320 ㎛.

Electroless Nickel Plating on Porous Carbon Substrate (다공성 탄소전극기지상의 무전해 니켈도금에 관한 연구)

  • Chun, So-Young;Rhyim, Young-Mok;Kim, Doo-Hyun;Lee, Jae-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.1
    • /
    • pp.75-80
    • /
    • 2010
  • Electroless nickel plating on porous carbon substrate was investigated. The pore sizes of carbon substrates were 16-20 ${\mu}m$ and over 20 ${\mu}m$. The carbon surface was changed from hydrophobic to hydrophilic after immersing the substrate in an ammonia solution for 40 min at $60^{\circ}C$. The contact angle of water was decreased from $85^{\circ}$ to less than $20^{\circ}$ after ammonia pretreatment. The content of phosphorous in nickel deposit was decreased with increasing pH and then deposits became crystallized. The thickness of nickel deposit was increased with increasing pH. The minimum concentration of $PdCl_2$ for the electroless nickel plating was 5 ppm and the thickness of nickel was not significantly affected by the concentration of $PdCl_2$.

Comparison of Acidic and Alkaline Bath in Electroless Nickel Plating on Porous Carbon Substrate (다공성 탄소전극상 무전해 니켈도금의 산성과 알칼리용액 비교 연구)

  • Chun, So-Young;Kang, In-Seok;Rhym, Young-Mok;Kim, Doo-Hyun;Lee, Jae-Ho
    • Journal of the Korean institute of surface engineering
    • /
    • v.43 no.2
    • /
    • pp.105-110
    • /
    • 2010
  • Electroless nickel plating on porous carbon substrate for the application of MCFC electrodes was investigated. Acidic and alkaline bath were used for the electroless nickel plating. The pore sizes of carbon substrates were 16-20 ${\mu}m$ and over 20 ${\mu}m$. The carbon surface was changed from hydrophobic to hydrophilic after immersing the substrate in an ammonia solution for 40 min at $60^{\circ}C$. The contact angle of water was decreased from $85^{\circ}C$ to less than $20^{\circ}$ after ammonia pretreatment. The deposition rate in the alkaline bath was higher than that in the acidic bath. The deposition rate was increased with increasing pH in both acidic and alkaline bath. The content of phosphorous in nickel deposit was decreased with increasing pH in both acidic and alkaline bath. The contents of phosphorous is low in alkaline bath. The minimum concentration of $PdCl_2$ for the electroless nickel plating was 10 ppm in alkaline bath and 5 ppm in acidic bath. The thickness of nickel was not affected by the concentration of $PdCl_2$.

Fabrication of a Full-Scale Pilot Model of a Cost-Effective Sodium Nickel-Iron Chloride Battery Over 40 Ah

  • Lee, Dong-Geun;Ahn, Byeong-Min;Ahn, Cheol-Woo;Choi, Joon-Hwan;Lee, Dae-Han;Lim, Sung-Ki
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.398-405
    • /
    • 2021
  • To fabricate a full-scale pilot model of the cost-effective Na-(Ni,Fe)Cl2 cell, a Na-beta-alumina solid electrolyte (BASE) was developed by applying a one-step synthesis cum sintering process as an alternative to the conventional solid-state reaction process. Also, Fe metal powder, which is cheaper than Ni, was mixed with Ni metal powder, and was used for cathode material to reduce the cost of raw material. As a result, we then developed a prototype Na-(Ni,Fe)Cl2 cell. Consequently, the Ni content in the Na-(Ni,Fe)Cl2 cell is decreased to approximately (20 to 50) wt.%. The #1 prototype cell (dimensions: 34 mm × 34 mm × 235 mm) showed a cell capacity of 15.9 Ah, and 160.3 mAh g-1 (per the Ni-Fe composite), while the #2 prototype cell (dimensions: 50 mm × 50 mm × 335 mm) showed a cell capacity of 49.4 Ah, and 153.2 mAh g-1 at the 2nd cycle.

Comparative Hepatotoxicity Assessment of Cadmium and Nickel with Isolated Perfused Rat Liver(IPRL) (적출간 관류법을 이용한 카드뮴과 니켈의 간독성 비교)

  • Cha, Bong-Suk;Chang, Sei-Jin;Lee, Jung-Woo;Wang, Seung-Jun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.33 no.1
    • /
    • pp.117-124
    • /
    • 2000
  • Objectives : It is the objective of this study to compare hepatotoxicity of nickel chloride and cadmium chloride with each other through IPRL(Isolated Perfused Rat Liver) method. Methods : Biochemical indicator of hepatic function such as AST(aspartate aminotransferase), ALT(alanine aminotransferase), LDH(lactate dehydrogenase) and perfusion flow rate were used as the indicator of hepatotoxicity. Oxygen consumption rate were used as vability indicator. $300({\pm}50)g$ - weighted rats were allocated randomly to each group($0{\mu}M,\;50{\mu}M,\;200{\mu}M\;NiCl_2\;and\;CdCl_2$ exposure) by 5, totally 25. After Krebs-Ringer bicarbonate butler solution flowed into the penal vein and passed the liver cell, it flowed out of vena cava. Liver was administered with each $NiCl_2\;and\;CdCl_2$ of each concentration and observed with buffer solution sampling time. Butler which got out of liver was sampled and then biochemical indicator of hepatotoxicity was measured. Results : AST, ALT, and LDH in buffer increased with sampling time much more in $CdCl_2$ exposure group than $NiCl_2$ exposure group in both 50 and $200{\mu}M$ and statistical significance w3s verified with 2-way repeated ANOVA. Viability was decreased more and more in all substances during passed time. Conclusions : It is inferred that $CdCl_2$ has stronger hepatotoxicity than $NiCl_2$. IPRL method would be used widely for acute hepatotoxicity when considerating the benefit of it.

  • PDF

The Effects of Current Density on the Grain Size of Electroplated Thick Film Nickel(Ni) by Using Ni Metal Powder Dissolved Chloride Bath (금속분말 Ni을 용해 한 Chloride Bath로 도금된 니켈후막의 입자크기에 대한 전류밀도 영향)

  • Park, Keun Yung;Uhm, Young Rang;Choi, Sun Ju;Park, Deok-Yong
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.1
    • /
    • pp.12-17
    • /
    • 2013
  • Nanocrystalline nickel (Ni) tick films were synthesized by direct current electrodeposition at current density from 1 to $30mA/cm^2$ and pH = 4. The basic composition of the bath, which was prepared by dissolving Ni metal particles in HCl, was 0.2M Ni ions. The effects of the current density on the average grain size of Ni deposits were investigated by XRD and SEM techniques. The results showed that the surface roughness was decreased as the saccharin addition was increased up to 2 g/l. The experimental results showed that the increase in the current density had a considerable effect on the average grain size of the Ni deposits. The perpendicular magnetization was raised as the thickness of coating layer was increased.

Tensile Properties of Nickel Electroform(l) (니켈 전주층의 인장 물성(1))

  • Kim I.;Lee J.;Kang K.;Kwon S.C.;Kim M.;Lee J.Y.
    • Journal of the Korean institute of surface engineering
    • /
    • v.38 no.1
    • /
    • pp.21-27
    • /
    • 2005
  • Tensile properties and hardness of nickel electroform from chloride-free nickel sulfamate electrolyte at 50℃ and PH 4.5 were investigated. Current density varied from 20 to 60 mA/㎠. The deposit thicknesses were 360, 480 and 980 ㎛. It was found in 480 ㎛ thick electroform that highest tensile and yield strengths and hardness of 83.7 ksi, 53.6 ksi and 216 DPH, respectively were obtained at a current density of 40 mA/㎠ and they were slightly decreased at 20 and 60 mA/㎠. However the ductility was lowest of 7.9% at 40 mA/㎠. Such a high strength and low ductility at 40 mA/㎠ seems to be related to the narrower columnar structure than those of other current densities. All the deposits exhibited pronounced necking behavior. Tensile strength, yield strength and ductility increased as the nickel electroform thickens. Initial strong (200) texture developed on stainless steel mandrel decreased and (111) and (220) textures increased as deposit thickness increased, whereas (200) texture was preferred as the current density increased.

The Effect of Annealing Heat Treatment by Anodic Polarization Impedance Experiments for Cu-10%Ni Alloy

  • Lee, Sung-Yul;Moon, Kyung-Man;Jeong, Jae-Hyun;Lee, Myeong-Hoon;Baek, Tae-Sil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.5
    • /
    • pp.536-541
    • /
    • 2015
  • Copper has been used extensively as an electric wire or as a base material in various types of machineries owing to its good electrical and thermal conductivity and good fabricating property, as well as its good corrosion resistance compared to iron. Furthermore, the copper-nickel alloy has significant corrosion resistance in severely corrosive environments. Although, cupro-nickel alloy shows better corrosion resistance than the brass and bronze series, this alloy also corroded in severely corrosive environments, including aggressive chloride ions, dissolved oxygen, and condition of fast flowing seawater. In this study, and annealing treatment at various annealing temperatures was carried out on the cupro-nickel (Cu-10%Ni) alloy, and the effects of annealing were investigated using electrochemical methods, such as measuring the polarization and impedance behaviors under flowing seawater conditions. The corrosion resistance increased by annealing compared to non heat treatment in the absence of flowing seawater. In particular, the sample annealed at $200^{\circ}C$ exhibited the best corrosion resistance. The impedance in the presence of flowing seawater showed higher values than in the absence of flowing seawater. Furthermore, the highest impedances was observed in the sample annealed at $800^{\circ}C$, irrespective of the present of flowing seawater. Consequently, the corrosion resistance of cupro-nickel (Cu-10%Ni) alloy in a severely corrosive environment can be improved somewhat by annealing.