• 제목/요약/키워드: new shear test condition

검색결과 45건 처리시간 0.024초

리모델링 아파트의 평면확장시 신/구 슬래브 접합부의 횡방향 하중전달 능력에 관한 실험적 연구 (An Experimental Study on Load Transfer Capacity for the Planar Joints between Existing and New Slab to Extend an Area of Remodelling apartment)

  • 임병호;김승훈;유영찬;최기선;강인석;정재철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.25-28
    • /
    • 2006
  • In general, post-installed dowel bars are used as a shear connector to ensure the composite actions between new slabs and existing slabs in an apartment remodelling constructions expecially for enlarging the interior space outward the existing buildings. But, it has not been checked that the connection performance between existing and new slab is satisfactory not only for the structural safety condition but also the for serviceability and dwelling requirements. In this research, an experimental works were presented to evaluate the load transfer capacity for the planar joints between existing and new slab. The existing slabs were obtained from the existing apartment housing which will be demolished, and were retrofitted with carbon fiber plate. Test results showed that the planar joints with post-installed dowel bars behaved in full composite modes until ultimate capacity of test specimens, so sufficient ultimate and serviceability performance are confirmed.

  • PDF

Improved analytical formulation for Steel-Concrete (SC) composite walls under out-of-plane loads

  • Sabouri-Ghomi, Saeid;Nasri, Arman;Jahani, Younes;Bhowmick, Anjan K.
    • Steel and Composite Structures
    • /
    • 제38권4호
    • /
    • pp.463-476
    • /
    • 2021
  • The concept of using Steel-concrete (SC) composite walls as retaining walls has recently been introduced by the authors and their effectiveness of resisting out-of-plane loads has also been demonstrated. In this paper, an improved analytical formulation based on partial interaction theory, which has previously been developed by the authors, is presented. The improved formulation considers a new loading condition and also accounts for cracking in concrete to simulate the real conditions. Due to a limited number of test specimens, further finite element (FE)simulations are performed in order to verify the analytical procedure in more detail. It is observed that the results from the improved analytical procedure are in excellent agreement with both experimental and numerical results. Moreover, a detailed parametric study is conducted using the developed FE model to investigate effects of different parameters, such as distance between shear connectors, shear connector length, concrete strength, steel plate thickness, concrete cover thickness, wall's width to thickness ratio, and wall's height to thickness ratio, on the behavior of SC composite walls subjected to out-of-plane loads.

절곡 강판을 이용한 AU합성보 덮개형 강재앵커의 전단성능 평가 (Shear Capacity Evaluation of Steel Plate Anchors Using Folded Steel Plate in AU-composite Beam)

  • 임환택;최병정
    • 한국강구조학회 논문집
    • /
    • 제29권5호
    • /
    • pp.389-400
    • /
    • 2017
  • U형 합성보를 근간으로 층고절감과 공기단축을 위하여 경제적이고 효율적인 새로운 형상의 AU합성보를 연구하였다. 그러나 U형 단면의 특성상 상부가 개방되어 폭 고정을 위한 별도의 철물이 필요하며 U형 단면과 콘크리트 사이의 합성을 위하여 수평전단력에 대한 저항체가 필요하다. 이러한 단점을 보완하기 위하여 A형의 덮개형 강재앵커를 개발하였다. 본 연구에서는 A형의 덮개형 강재앵커에 대한 직접전단실험을 수행하고 수평전단력에 의한 내력을 평가하였다. 덮개형 강재앵커는 적용되는 데크플레이트의 형상에 따라 연속형과 단속형으로 구분하였다. 실험 결과, 연속형의 경우 스터드 앵커와 동일한 구조적 거동으로 강도와 변위가 스터드 앵커 이상으로 발휘하여 스터드앵커와 동일하게 평가할 수 있다. 단속형의 경우는 직접전단실험과 단순모델의 유한요해석을 통해 폭-높이비가 증가할수록 전단강도가 감소하였다. 이에 따라 스터드앵커의 전단강도식을 개선하여 성능평가식을 제안하였다.

풍력발전기용 복합재 블레이드의 구조 해석 및 인증시험 (Structural Analysis and Proof Test of Composite Rotor Blades for Wind Turbine)

  • 박선호;한경섭
    • 신재생에너지
    • /
    • 제4권3호
    • /
    • pp.45-50
    • /
    • 2008
  • GFRP based composite rotor blades were developed for 750 kW & 2 MW wind turbines. The blade sectional geometry was designed to have a general shell-spar and shear web structure. For verifying the structural safety under all relevant extreme loads specified in the GL guidelines, the structural analysis of the rotor blades was performed using commercial FEM codes. The static load carrying capacity, blade tip deflections and natural frequencies were evaluated to satisfy the strength and stability requirements. Full-scale proof tests of rotor blades were carried out with optical fiber sensors for real-time condition monitoring. Finally, the prototype of each rotor blade passed all proof tests for GL certification.

  • PDF

750kW 풍력발전기 현장시험을 통한 하중 비교 (Load comparison of 750kW WTGS by field test)

  • 방조혁;홍혁수;박진일;류지윤
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.303-306
    • /
    • 2008
  • This study proposes an essential process of type certificate, which is load comparison for proving the calculated design load. The load measurement was carried out according to IEC 61400-13 standard and the load calculation was performed with same condition using FLEX 5 code. For more accurate load simulation, the controller parameter of original model at the design stage was modified to site optimized value and some node points are added to coincidence with measurement. The load comparison was performed with various wind parameter, turbulence intensity and wind shear. As a result, simulated loads ware good agreed with the measured load. Therefore, the calculated design loads according to IEC 61400-1 standard were proved to valid.

  • PDF

New site classification system and design response spectra in Korean seismic code

  • Kim, Dong-Soo;Manandhar, Satish;Cho, Hyung-Ik
    • Earthquakes and Structures
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2018
  • A new site classification system and site coefficients based on local site conditions in Korea were developed and implemented as a part of minimum design load requirements for general seismic design. The new site classification system adopted bedrock depth and average shear wave velocity of soil above the bedrock as parameters for site classification. These code provisions were passed through a public hearing process before it was enacted. The public hearing process recommended to modify the naming of site classes and adjust the amplification factors so that the level of short-period amplification is suitable for economical seismic design. In this paper, the new code provisions were assessed using dynamic centrifuge tests and by comparing the design response spectra (DRS) with records from 2016 Gyeongju earthquake, the largest earthquake in history of instrumental seismic observation in Korea. The dynamic centrifuge tests were performed to simulate the representative Korean site conditions, such as shallow depth to bedrock and short-period amplification characteristics, and the results corroborated with the new DRS. The Gyeongju earthquake records also showed good agreement with the DRS. In summary, the new code provisions are reliable for representing the site amplification characteristic of shallow bedrock condition in Korea.

신형상 데크플레이트를 이용한 합성슬라브의 구조적인 거동에 대한 연구 (A Study on the Structural Behavior of the Composite Slab with New-Shaped Deckplate)

  • 허충;문태섭
    • 한국강구조학회 논문집
    • /
    • 제9권3호통권32호
    • /
    • pp.341-350
    • /
    • 1997
  • 철골구조 또는 철골철근콘크리트구조 건물의 바닥슬래브 구조는 공사도 무비의 절감과 공기단축의 필요성에 따라 데크플레이트의 사용이 보편화되어 있다. 이러한 데크플레이트는 설치의 용이성 및 작업공간의 제공, 콘크리트 타설시에는 액성 상태의 콘크리트 사하중과 시공하중에 견디는 단일 휨부재로서 거푸집 역할을 하며, 구조용(합성용) 데크플레이트는 콘크리트가 경화한 후 합성슬래브의 주인장재 역할을 한다. 국내의 현행 법규상 데크플레이트를 구소재로 사용하는 경우에는 반드시 내화구조로 하여야 하며 이때 내화피복재의 추가시공은 필수적이다. 데크플레이트를 거푸집으로 사용하는 경우는 내화피복은 필요 없으나 콘크리트 및 철근 추가의 사용으로 건물의 자중이 증가하게 된다. 그러나, 현재 국내에서 사용되고 있는 데크플레이트는 대부분 거푸집용으로 위의 문제점을 갖고 있는 실정이고, 합성용 데크플레이트의 경우는 실험한 결과 대부분 슬립 하중이 최대하중으로 결정되는 매우 취성적인 거동을 나타내고 있다. 따라서 본 논문에서는 근래에 행하여진 합성용 데크플레이트의 실험을 근간으로 새로운 형상의 구조용 데크플레이트를 제시하며 이를 사용한 합성슬래브의 거동을 파악하고, 신형상의 합성슬래브 실험 결과 ASCE, EC4규준과 비교하며, 이론 모멘트-곡률관계로부터 구한 하중-처짐곡선을 실험치와 비교한다.

  • PDF

PSD를 이용한 혼합모드 하중하에서 탄소성 파괴인성평가에 관한 실험적인 연구 (An Experimental Study on the Evaluaiton of Elastic-Plastic Fracture Toughness under Mixed Mode I-II-III Loading Using the Optical PSD)

  • 김희송;이춘재
    • 대한기계학회논문집A
    • /
    • 제20권4호
    • /
    • pp.1263-1274
    • /
    • 1996
  • In this paper, as elastic-plastic fracture toughness test under mixed mode loading was proposed using a single edge-cracked specimen subjected to bending moment(M), shearing force(F), and twisting moment(T). The J-integral of a crack in the specimen is expressed in the form J=$J_I$+ $J_II$$J_III$, where $J_I$, $J_II$ and $J_III$ are the components of mode I, mode II and mode III deformation, respectively. $J_I$, $J_II$ and $J_III$ can be estimated from M-$\theta$ ($\theta$;crack opening angle), F-U(U; crack shear displacement) and T-$\alpha$ ($\alpha$;crack twisting angle). In order to obtain the the M<-TEX>$\theta$, F-U and T-$\alpha$ diagram inreal time, a new deformaiton gage for mixed mode loading was proposed using the optical position sensing device(PSD). The elastic-plastic fracture toughness test was carried out with an aluminum alloy. The loading apparatus was designed and manufactured for this experiment. For the loading condition of the crack initatio in the mixed mode, the MMT -3(mode I+ mode II+ mode III) has the lowest values out of the all specimens. This implies that MMT-3 is possible of the crackinitation at lower load, if the specimen acts on together with the torque under the same loading condition. An elastic-plastic fracture toughness test using the PSD brings a successful experimentation in measuring the crack deformation(mode I+ mode II+ mode III).

록 볼트 및 스파이럴 볼트의 지보특성 (Support Characteristics of Rock Bolt and Spiral Bolt)

  • 조영동;송명규;이청신;강추원;고진석;강성승
    • 터널과지하공간
    • /
    • 제19권3호
    • /
    • pp.181-189
    • /
    • 2009
  • 이 연구는 지보재로서 가장 널리 사용되고 있는 록 볼트와 새로운 지보 형태인 스파이럴 볼트에 대한 지보특성을 비교하여 두 지보재의 지보효과를 평가하는데 있다. 이를 위하여 시멘트-모르타르 그라우트의 양생기간이 7일과 28일에 대한 록 볼트와 스파이럴 볼트의 실내인발시험을 실시하였으며, 각 시험결과로부터 인발하중, 변위 그리고 구속압, 내부압, 전단응력 등을 각각 구하였다. 인발하중에 대한 변위의 관계를 보면 각각의 양생기간에 대해서 스파이럴 볼트의 변위가 록 볼트에 비해 크게 나타나는데, 이것은 록 볼트의 역학적 성질이 스파이럴 볼트보다 크기 때문인 것으로 사료된다. 또한 양생기간이 길 경우 두 지보재의 변위는 거의 동일하거나 감소하는 경향을 보이는데, 그 원인은 양생기간에 따라 그라우트의 압축강도가 증가하므로 지보재와 시멘트-모르타르 그라우트 사이의 부착력이 증가하기 때문으로 사료된다. 구속압을 비교한 결과 동일한 인발하중단계에서 스파이럴 볼트의 구속압이 록 볼트보다 크게 나타났다. 이러한 사실은 같은 조건하에 있는 지반이나 암반에 지보재를 설치 할 경우 시공성 측면에서 스파이럴 볼트가 록 볼트보다 지반이나 암반의 안정성을 확보하는데 더 효과적임을 지시한다. 이상의 결과를 종합해 볼 때 같은 조건하에 있는 지반이나 암반에 지보재를 설치할 경우 새로운 형태의 지보재인 스파이럴 볼트가 기존의 지보재인 록 볼트보다 인발하중과 구속압을 더 크게 발휘하는 것으로 사료된다. 아울러, 지보재에 있어서 경제성, 현장에서의 지보재 시공성 뿐만 아니라 지보재 설치 전후의 지반이나 암반의 안정성 측면 등을 고려할 때 스파이럴 볼트가 록 볼트에 비하여 더 효과적일 것으로 판단된다.

풍력발전기용 복합재 블레이드의 구조해석 및 인증시험 (Structural Analysis and Proof Test of Composite Rotor Blades for Wind Turbine)

  • 박선호;한경섭
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.299-302
    • /
    • 2008
  • GFRP based composite rotor blades were developed for 750kW & 2MW wind turbines. The blade sectional geometry was designed to have a general shell-spar and shear web structure. For verifying the structural safety under all relevant extreme loads specified in the GL guidelines, the structural analysis of the rotor blades was performed using commercial FEM codes. The static load carrying capacity, blade tip deflections and natural frequencies were evaluated to satisfy the strength and stability requirements. Full-scale proof tests of rotor blades were carried out with optical fiber sensors for real-time condition monitoring. Finally, the prototype of each rotor blade passed all proof tests for GL certification.

  • PDF