• Title/Summary/Keyword: new power industry

Search Result 731, Processing Time 0.029 seconds

Calculation for Components of Locational Marginal Price considering Demand-Side Bidding in a Competitive Electricity Market (경쟁시장내의 수요자원입찰을 고려한 모선별 한계가격의 구성요소산정 기법)

  • Kim, Hyun-Houng;Kim, Jin-Ho;Park, Jong-Bae;Shin, Joong-Rin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1157-1166
    • /
    • 2008
  • This paper presents a new approach for the evaluation of location marginal prices (LMPs) considering demand-side bidding (DSB) in a competitive electricity market. The stabilization of the electric power supply and demand balance is one of the major important activities in electric power industry. In this paper, we present an analytical method for calculation of LMPs considering DSB, which has opportunity to compete with generating units, as England & Wales Pool's DSB scheme[1]. Also, we propose a new approach that LMP considering DSB is divided into three components. The proposed approach can be used for the evaluation of demand-side bidding into the electricity market and the assessment of the influence of DSB on total production costs and LMPs as well as three components.

Analysis of a 3-Degree-of-Freedom Spherical Actuator using VCM Principle (보이스 코일 모터 방식을 이용한 3 자유도 구형모터의 분석)

  • Chu, Junghyun;Niguchi, Noboru;Hirata, Katsuhiro
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.3
    • /
    • pp.207-215
    • /
    • 2017
  • The superior performance of the spherical actuator is establishing a new trend in the industry. Spherical actuators can perform multiple degrees-of-freedom (DOF) motions by using only one actuator. Therefore, a multi-DOF device using the spherical actuator can reduce weight and simplify the structure. This paper proposes a new spherical actuator that uses the operational principle of a rotational voice coil motor. The effectiveness of the actuator is verified through 3-D finite element method.

An Improved Gate Control Scheme of Series Connected IGBTs (IGBT 직렬 연결을 위한 게이트 구동기법)

  • Kim, Wan-Jung;Choi, Chang-Ho;Hyun, Dong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.195-197
    • /
    • 1998
  • The large scale industry needs high voltage converters. Therefore series connection of power semiconductor devices is necessary. It is important to prevent a device induced the overvoltage above ratings by proper voltage balancing in the field of IGBT series connection. In addition, the overvoltage induced by a stray inductance has to be limited in the high power circuit. This paper proposes a new gate control scheme which can balance the voltage properly and limit the overshoot by control the slope of collector voltage under series connected IGBT turn-off transient. The propose gate control scheme limits the overvoltage by sensing the collector voltage and controlling the gate signal actively. The new series connected IGBT gate driver is made and its validity is verified by the experimental results for series connected IGBT circuit.

  • PDF

A study on new & renewable energy capacity factor in Feed-In Tariff fund (신재생에너지 이용률이 발전차액에 미치는 영향에 관한 연구)

  • Jeon, Byung-kyu;Moon, Joon-sang;Oh, Seok-hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.200-203
    • /
    • 2009
  • 현재 발전차액 지원을 받고 있는 신재생에너지 전원은 태양광, 풍력, 수력, 매립가스, 바이오 가스, 연료전지 등 6개 전원이 있다. 신재생에너지 중에서 태양광, 조력, 연료전지, 풍력의 기준가격은 고정가격이며, 폐기물은 변동가격이고, 수력, 매립가스, 바이오가스, 바이오매스는 고정가격과 변동가격 중에서 선택할 수 있도록 되어 있다. 지난 2년간 신재생에너지 발전소 실적 이용률을 기준가격 적용 이용률과 비교해 보면 매립가스(20MW 미만), 바이오가스, 연료전지 이용률은 기준가격 적용 이용률 보다 낮게 나타났으며, 특히 바이오가스는 실적 이용률이 매우낮게 나타났다. 기타 신재생에너지 전원은 실적 이용률이 높게 나타났다. 발전차액(기반기금)은 기준가격에서 계통한계가격을 뺀 금액을 의미하며 고정가격, 변동가격의 요금선택에 따라 발전차액에 미치는 요소들이 달라진다. 고정가격을 선택한 경우는 계통한계가격, 이용률(전력 거래량)이 영향을 미치며 변동가격을 선택한 경우는 이용률만이 발전차액에 영향을 미친다.

  • PDF

A Comparison of Reactive Power Pricing Methods in Derugulated Markets (전력시장체제에서 무효전력 요금산정 방법론 비교)

  • Park Sung Jin;Ro Kyoung Soo
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.692-694
    • /
    • 2004
  • As the electric power industry has gone for a deregulated environment from a vertically integrated structure, operations and controls of systems invite new challenges. In the past certain activities, such as voltage and frequency control, were considered as a part of integrated power supply. But now, these become parts of ancillary services which are independent and detailed, and have situations non-disregardable for operation of systems. This paper examines a management of reactive power services adopted in deregulated foreign and domestic markets.

  • PDF

A Fuel Cell Generation System with a New Active Clamp Sepic-Flyback Converter

  • Lee, Won-Cheol;Jang, Su-Jin;Kim, Soo-Seok;Lee, Su-Won;Won, Chung-Yuen
    • Journal of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.26-35
    • /
    • 2009
  • A high efficiency active clamp sepic-flyback converter is presented for fuel cell generation systems. The proposed converter is a superposition of a sepic converter mode and. flyback converter mode. The output voltages of the sepic converter mode and flyback converter mode can be regulated by the same PWM technique with constant frequency. By merging the sepic and flyback topologies, they can share the transformer, power MOSFET and active clamp circuit. The result has outstanding advantages over conventional active clamp DC-DC converters: high efficiency, high power density, and component utilization. Simulation results and experimental results are presented to verify the principles of operation for the proposed converter.

The forecasting evaluation of the high-order mixed frequency time series model to the marine industry (고차원 혼합주기 시계열모형의 해운경기변동 예측력 검정)

  • KIM, Hyun-sok
    • The Journal of shipping and logistics
    • /
    • v.35 no.1
    • /
    • pp.93-109
    • /
    • 2019
  • This study applied the statistically significant factors to the short-run model in the existing nonlinear long-run equilibrium relation analysis for the forecasting of maritime economy using the mixed cycle model. The most common univariate AR(1) model and out-of-sample forecasting are compared with the root mean squared forecasting error from the mixed-frequency model, and the prediction power of the mixed-frequency approach is confirmed to be better than the AR(1) model. The empirical results from the analysis suggest that the new approach of high-level mixed frequency model is a useful for forecasting marine industry. It is consistent that the inclusion of more information, such as higher frequency, in the analysis of long-run equilibrium framework is likely to improve the forecasting power of short-run models in multivariate time series analysis.

Line Impedance Estimation Based Adaptive Droop Control Method for Parallel Inverters

  • Le, Phuong Minh;Pham, Xuan Hoa Thi;Nguyen, Huy Minh;Hoang, Duc Duy Vo;Nguyen, Tuyen Dinh;Vo, Dieu Ngoc
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.234-250
    • /
    • 2018
  • This paper presents a new load sharing control for use between paralleled three-phase inverters in an islanded microgrid based on the online line impedance estimation by the use of a Kalman filter. In this study, the mismatch of power sharing when the line impedance changes due to temperature, frequency, significant differences in line parameters and the requirements of the Plug-and-Play mode for inverters connected to a microgrid has been solved. In addition, this paper also presents a new droop control method working with the line impedance that is different from the traditional droop algorithm when the line impedance is assumed to be pure resistance or pure inductance. In this paper, the line impedance estimation for parallel inverters uses the minimum square method combined with a Kalman filter. In addition, the secondary control loops are designed to restore the voltage amplitude and frequency of a microgrid by using a combined nominal value SOGI-PLL with a generalized integral block and phase lock loop to monitor the exact voltage magnitude and frequency phase at the PCC. A control model has been simulated in Matlab/Simulink with three voltage source inverters connected in parallel for different ratios of power sharing. The simulation results demonstrate the accuracy of the proposed control method.

3-Phase RMS Voltage Measurement Method of Virtual Frequence using Instantaneous Power Component Concept (순시전력 합성 개념을 이용한 가상주파수 3상 실효전압 계측기법)

  • Park, Seong-Mi;Yang, Ji-Hoon;Park, Sung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.3
    • /
    • pp.251-257
    • /
    • 2019
  • This paper proposes a new measurement method using virtual power concept to measure the effective value of 3-phase voltage with variable frequency. The conventional effective value measurement method uses a method of integrating data sampled during one or half cycle of the power voltage and averaging it. In this method, since the effective voltage is calculated every cycle, a time delay occurs in the measured effective voltage and it is s a problem to measure the effective value of a device whose frequency varies from time to time, such as a generator. The proposed 3-phase voltage rms measurement method has an advantage that it can measure accurate voltage RMS value regardless of measurement frequency variation. In particular, there is an advantage in that it is possible to measure a 3-phase effective voltage rather than an average value of the effective voltage of each phase in a 3-phase unbalance voltage. In addition, the validity of the proposed method is verified by using the Psim simulation tool and the experimental results are analyzed by applying the proposed measurement algorithm to the actual three phase synchronous generator voltage measurement experiment.

Conceptual Design of Interim Storage Facility for PWR Spent Nuclear Fuel (경수로 사용후핵연료 중간저장시설 개념(안) 수립)

  • Hyun-goo Kang;Chang-min Shin;Sang-Hwan Lee;Tae-Chul Moon
    • Journal of Radiation Industry
    • /
    • v.18 no.3
    • /
    • pp.255-266
    • /
    • 2024
  • The uranium nuclear fuel used in nuclear power generation needs to be replaced with new fuel after a certain period. In South Korea, the spent nuclear fuel generated during this process is temporarily stored within the nuclear power plant site, and there are ongoing issues with the saturation of storage capacity. To address these problems, the South Korea government has established a plan to manage high-level radioactive waste, including provisions for securing interim storage facilities. An interim storage facility is designed to safely store spent nuclear fuel for certain period before its permanent disposal. This study analyzed leading international cases of interim storage facilities that are technically feasible and can reduce the operating period of temporary storage facilities for spent nuclear fuel within nuclear power plant sites. It also presented the technical concepts required for the operation of interim storage facilities for spent fuel from PWR(Pressurized Water Reactor), reflecting the situation in South Korea.