• 제목/요약/키워드: neutral variation

검색결과 196건 처리시간 0.031초

하중(荷重) 변화(變化)가 적층목질재(積層木質材)(Glulam)의 중립축(中立軸)의 위치변이(位置變移)에 미치는 영향(影響) (Effect of Load Variation on Transition of Neutral Axis of Laminated Veneer Lumber (LVL))

  • 박헌;안치환
    • Journal of the Korean Wood Science and Technology
    • /
    • 제19권3호
    • /
    • pp.35-44
    • /
    • 1991
  • In this study, thickness 40mm glulams were composed of thickness 5mm, 10mm Quercus laminas and Pinus koraiensis laminas to study on the effect of load variation on transition of neutral axis of laminated veneer lumber(LVL). The transition of neutral axis was examined by strain variation, which was checked by strain gauge. amplifier, recorder, and strain meter. The elasticity of glulam was estimated by E = $\Sigma(E_i\;I_ i)$/I and this estimated elasticity values were compared with the elasticity values of glulam in bending. The result obtained can be summarized as follows: 1. The location of neutral axis of glulam was effected by glulam composition methods 2. The neutral axis did not shift by load variation within proportional limit. 3. The estimated elasticity of glulam by E = $\Sigma(E_i\;I_ i)$/I showed much lower value than the elasticity of glulam in bending.

  • PDF

계통연계형 3상 3레벨 태양광 인버터의 중성점 전압제어 (Neutral Point Voltage Control for Grid-Connected Three-Phase Three-Level Photovoltaic Inverter)

  • 박운호;양오
    • 반도체디스플레이기술학회지
    • /
    • 제14권4호
    • /
    • pp.72-77
    • /
    • 2015
  • Three-level diode clamped multilevel inverter, generally known as neutral point clamped (NPC) inverter, has an inherent problem causing neutral point (NP) potential variation. Until now, the NP potential problem of variation has been investigated and lots of solutions have also been proposed. This paper presents a neutral point voltage control technology using the anti-windup PI controller and offset technology of PWM (Pulse Width Modulation) to control the variation of NPC 3-phase three-level inverter neutral point voltage. And the proposed algorithm is tested and verified using a PLL (Phase Locked Loop) in order to synchronize the phase voltage from the line voltage of grid. It significantly improves the voltage balancing under a solar fluctuation conditions of the inverter. Experimental results show the good performance and effectiveness of the proposed method.

중성점 전류 리플을 고려한 3-레벨 인버터의 공간 벡터 펄스폭 변조 기법 (A SVPWM for the Small Fluctuation of Neutral Point Current in Three-level Inverter)

  • 김래영;이요한;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 연구회 합동 학술발표회 논문집
    • /
    • pp.33-37
    • /
    • 1998
  • For the high power variable speed applications, the DCTLI(diode clamped three-level inverter) have been widely used. This paper describes the analysis of the neutral point current of the DCTLI and the improved space vector-based PWM strategy considering the switching frequency of power devices, that minimizes the fluctuation of the neutral point current in spite of high modulation index region and low power factor. It contributes to decrease the capacitance of dc-link capacitor bank and to increase the neutral point voltage controllable region. Especially, even if second (or even) order harmonic is induced in load current (at this situation, is was investigated that the general control method can not suppress the neutral point voltage variation), this PWM can provide effective control method to suppress the neutral point voltage variation. Various simulation results by means of Matlab/Simulation are presented to verify the proposed PWM.

  • PDF

3레벨 NPC 인버터 개방성 고장 시 중성점 전압변동에 관한 연구 (A Study on the Neutral Point Potential Variation under Open-Circuit Fault of Three-Level NPC Inverter)

  • 박종제;박병건;하동현;현동석
    • 전력전자학회논문지
    • /
    • 제14권4호
    • /
    • pp.333-342
    • /
    • 2009
  • 중성점 클램핑 방식(Neutral Point Clamped) 인버터로 알려져 있는 3레벨 NPC 인버터는 그 구조적 특성상 직류-링크(DC-link) 중성점(Neutral Point)에서 전압이 변동한다. 지금까지 많은 논문에서 이 문제에 대한 연구가 진행되었고 다양한 형태의 해결책들이 제시되었다. 그러나 인버터 내부에서 고장이 발생하여 그에 따른 고장허용제어가 NPC 인버터 시스템에 적용되었을 경우 중성점 전압변동은 정상 운전 시 나타나는 전압변동과 다르게 나타나기 때문에 고장허용 제어에 따른 중성점 전압변동에 대한 분석이 필요하다. 본 논문에서는 삼각파 비교 변조방법을 시스템에 적용하였을 경우 정상운전과 고장 발생 과 고장허용 제어 적용 시 직류-링크 중성점 전압 변동이 어떤 양상으로 나타나는지 분석하고 고장허용 제어에 의한 NPC 인버터의 고장검출 시간과 커패시터의 용량 사이의 관계를 고찰하였다. 시뮬레이션과 실험 결과를 이용하여 이론적 분석의 타당성을 검증하였다.

3레벨 NPC인버터 고장 시 중성점 전압변동에 관한 연구 (Study of Neutral Point Potential Variation for Three-Level NPC Inverter under Fault Condition)

  • 박종제;김태진;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.385-387
    • /
    • 2008
  • Three-level Diode Clamped Multilevel Inverter, generally known as Neutral-Point-Clamped(NPC) inverter, has an inherent problem causing Neutral Point(NP) potential variation. Until now, in many literatures NP potential problem has been investigated and lots of solutions have also been proposed. However, in the case of NP potential variation was rarely published from the standpoint of reliability. In this paper, NP potential is analytically investigated both normal and fault conditions under carrier based PWM. Subsequently, relation between fault detection time and size of capacitor is analyzed. This information is explored by simulation results, which contribute to enhance the reliability of the NPC inverter system.

  • PDF

중공소재의 재경 변화에 따른 스퍼어기어 단조에 관한 연구 (A Study on the Forging of Spur Gears with Variation of Inner Diameter in Hollow Billets)

  • 조해용;최재찬;최종웅;민규식
    • 소성∙가공
    • /
    • 제4권3호
    • /
    • pp.257-266
    • /
    • 1995
  • A simulation method based on upper bound method is developed in order to characterize forging characters in forging of spur gears. In this paper, utilizing a kinematically admissible velocity field and applying it to investigate the effect of inner diameter of holow billet. In the analysis, to predict the variation of inner diameter of hollw billet, neutral surface has been introduced. The neutral surface of each step is assumed as a circle and determined in order to have minimum forging energy by golden section method. By this method, the variation of inner diameter of billet during spur gear forging is successfully predicted. As a result, the selection of inner diameter of initial billet is very important to reduce the forging load.

  • PDF

다양한 불평형 계통 상황에서 계통 연계형 3-레벨 NPC 컨버터의 중성점 전류 변동에 대한 해석 및 제어 (Analysis and Control of Neutral Point Current Deviation in Grid Tied 3-Level NPC Converter under Various Grid Unbalanced Conditions)

  • 최재훈;서용석
    • 전력전자학회논문지
    • /
    • 제25권5호
    • /
    • pp.385-393
    • /
    • 2020
  • This study introduces an analysis and control method for the variation of neutral point current in a grid-tied three-level neutral point clamped (NPC) converter under various grid imbalance operating conditions. Various fault cases with unbalanced amplitude and phase are systematically categorized and described using a unified metric called the imbalance factor. The fundamental component of neutral point current is generated under grid imbalance cases. The pattern and behavior of this fundamental component of neutral point current highly depend on the imbalance factor regardless of the particular type of grid fault cases. The control scheme for regulating the negative sequential component of AC input current effectively reduces the size of the fundamental component of neutral point current under a wide range of grid imbalance cases. The control scheme will enable a grid-tied three-level NPC converter to operate reliably and stably under various types of grid faults.

Extended Neutral Particle Analyzer System for the KSTAR

  • Kim, Sun-Ho;Gu, Dong-Jin;Park, Min;Ahn, Chan-Yong;Wang, Son-Jong;Kim, Sung-Kyu
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.272-272
    • /
    • 2012
  • Additional neutral particle analyzer has been installed to investigate the variation of fast ion tails with regard to the line of sight during 2012 KSTAR campaign. The system has the same photo-diode particle detector as previous system [1]. Both newly installed system and previous system modifield for 2012 campaign have two channels. One has a particle stopper transparent to hard X-ray, the other has no one. It will be used to separate the hard X-ray component from total hard X-ray and fast neutral counts. It is expected to measure fast ion tails more clearly through this extended system. A detailed system and calibration result will be presented in the conference.

  • PDF

Aspergillus flavus의 강력 protease생성 돌연변이의 유발 (On a highly proteolytic mutant strain of Aspergillus flavus)

  • 이영녹;박용근;고상균
    • 미생물학회지
    • /
    • 제18권2호
    • /
    • pp.51-58
    • /
    • 1980
  • Mutational experiments were performed to improved to improve the protease productivity of Aspergillus flavus KU 153, which is selected among the wild strains. A UV-induced mutant strain having high protease productivity was obtained by the use of the clear zone method as a simple criterion for a primary screening test. Neutral and alkaline protease activities of hte mutant strain were higher than 1.8 times, comopared with those of the parental strain, respectively, while in the case of acid protease, it was 2.7 times. The mutant strain selected was more powerful in the production of cellulase and amylase, as well s protease in wheat bran, compared with those of the parental strain. protease production of the parental strain has reached maximum level at 3 days culture, while alkaline nad neutral protease production of the mutantstrain has reached at 2 days culture. On the other hand, the mutant strain formed the spore slowly, compared with the parental strain. Column chromatography of the neutral protease on DEAE-Sephadex A-50 showed that the mutant strain was not induced the formation of another neutral protease isozyme, but induced the variation in the function of regulatory gene.

  • PDF

Neutral-point Voltage Balancing Strategy for Three-level Converter based on Disassembly of Zero Level

  • Wang, Chenchen;Li, Zhitong;Xin, Hongliang
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.79-88
    • /
    • 2019
  • The neutral-point (NP) voltage of three-phase three-level NP-clamped converters is needed for balance. To maintain NP potential and suppress ripple, a novel NP voltage balancing strategy is proposed in this work. The mechanism of NP voltage variation is studied first. Then, the relationship between the disassembly of zero level (O level) and NP current is studied comprehensively. On these bases, two methods for selecting one of three output phases for the disassembly of its O level are presented. Finally, simulation and experimental results verify the validity and practicability of the proposed algorithms.