• 제목/요약/키워드: network flow

검색결과 2,342건 처리시간 0.023초

기후변화가 주암호 수온성층구조에 미치는 영향 예측 (Projection of the Climate Change Effects on the Vertical Thermal Structure of Juam Reservoir)

  • 윤성완;박관영;정세웅;강부식
    • 한국물환경학회지
    • /
    • 제30권5호
    • /
    • pp.491-502
    • /
    • 2014
  • As meteorology is the driving force for lake thermodynamics and mixing processes, the effects of climate change on the physical limnology and associated ecosystem are emerging issues. The potential impacts of climate change on the physical features of a reservoir include the heat budget and thermodynamic balance across the air-water interface, formation and stability of the thermal stratification, and the timing of turn over. In addition, the changed physical processes may result in alteration of materials and energy flow because the biogeochemical processes of a stratified waterbody is strongly associated with the thermal stability. In this study, a novel modeling framework that consists of an artificial neural network (ANN), a watershed model (SWAT), a reservoir operation model(HEC-ResSim) and a hydrodynamic and water quality model (CE-QUAL-W2) is developed for projecting the effects of climate change on the reservoir water temperature and thermal stability. The results showed that increasing air temperature will cause higher epilimnion temperatures, earlier and more persistent thermal stratification, and increased thermal stability in the future. The Schmidt stability index used to evaluate the stratification strength showed tendency to increase, implying that the climate change may have considerable impacts on the water quality and ecosystem through changing the vertical mixing characteristics of the reservoir.

단기 물 수요예측 시뮬레이터 개발과 예측 알고리즘 성능평가 (Development of Water Demand Forecasting Simulator and Performance Evaluation)

  • 신강욱;김주환;양재린;홍성택
    • 상하수도학회지
    • /
    • 제25권4호
    • /
    • pp.581-589
    • /
    • 2011
  • Generally, treated water or raw water is transported into storage reservoirs which are receiving facilities of local governments from multi-regional water supply systems. A water supply control and operation center is operated not only to manage the water facilities more economically and efficiently but also to mitigate the shortage of water resources due to the increase in water consumption. To achieve the goal, important information such as the flow-rate in the systems, water levels of storage reservoirs or tanks, and pump-operation schedule should be considered based on the resonable water demand forecasting. However, it is difficult to acquire the pattern of water demand used in local government, since the operating information is not shared between multi-regional and local water systems. The pattern of water demand is irregular and unpredictable. Also, additional changes such as an abrupt accident and frequent changes of electric power rates could occur. Consequently, it is not easy to forecast accurate water demands. Therefore, it is necessary to introduce a short-term water demands forecasting and to develop an application of the forecasting models. In this study, the forecasting simulator for water demand is developed based on mathematical and neural network methods as linear and non-linear models to implement the optimal water demands forecasting. It is shown that MLP(Multi-Layered Perceptron) and ANFIS(Adaptive Neuro-Fuzzy Inference System) can be applied to obtain better forecasting results in multi-regional water supply systems with a large scale and local water supply systems with small or medium scale than conventional methods, respectively.

완전 연동형 SWAT-MODFLOW 결합모형 (I) 모형의 개발 (The Development of Fully Coupled SWAT-MODFLOW Model (I) Model Development)

  • 김남원;정일문;원유승
    • 한국수자원학회논문집
    • /
    • 제37권6호
    • /
    • pp.499-507
    • /
    • 2004
  • 본 연구에서는 준 분포형 지표수 유출모형인 SWAT과 3차원 지하수 유동모형인 MODFLOW의 완전 연동형 결합모형을 독자적인 방식에 따라 개발했다. SWAT의 지하수 모형성분은 집중형이므로 분포형 매개변수와 변화하는 양수량, 지하수위의 변화 등을 고려하지 못하며 MODFLOW 모형은 주요 입력자료인 함양량의 정확한 산정이 어렵다는 한계를 안고 있다. 이를 극복하기 위해 준분포형 모형인 SWAT의 HRU를 분포형 모형인 MODFLOW의 격자로 대응시키기 위해 DEM을 이용한 HRU-GRID변환기법을 독자적으로 개발하였으며, 수문성분 교환은 지하수 함양량의 전달과정과 하천네트워크-대수층간의 상호작용을 고려하여 완성하였다 결합모형을 이용하면 지표수나 지하수 모형만으로는 해결되지 않는 하천-대수층간의 경계유량을 고려한 유출해석이 가능해짐으로써 지하수 유출량을 포함한 유역내 총 유출량의 신뢰성이 증대될 것으로 기대된다.

정보통신기술과 기업공간의 재조직 (Information and Communication Technology and the Organization of Corporate Space)

  • 황주성
    • 지역연구
    • /
    • 제12권2호
    • /
    • pp.99-116
    • /
    • 1996
  • This study investigates the nature and patterns of interrelation between the emerging information and communication technology(ICT) and the organization of corporate space, both theoretically and empirically. In this work, ICT is conceptualized not so much a space-adjusting technology as an organizational technology. ICT is considered as a governance technology which is related to coordination function within a firm. Therefore, it is supposed to have a great relevance to the spatial reorganization of functions within a firm. Both questionnaire and case study method are used to gather necessary data from Korean electronics manufactures. The results of this study can be summarized as follow. First, the spatial structure of a firm, which is operationalised as the number and type of spatially separated establishments, is turned out to have a great explanatory power to its adoption of computer networks. Computer networks in muli-locational companies are introduced to overcome the limits of its spatial structure, such as duplication of functions, such as duplication of functions, loss of time spent in proceeding a job between different functional units, and unresponsiveness to the change of market demand. Second, new spatial division of labor and function could be possible through a series of business process reengineering, not through the mere adoption of ICT. Case studies reveal that computer network could help a firm to realize new forms of spatial division of labor, especially in those functions which is mainly based on the flow of information. Such function as ICT management, sales logistics and after-sales service are major parts where a new operational unit has appeared with the help of ICT. From above results, it can be concluded that the interrelations between ICT and organizational space should be approached intimately integrated with the change of industrial structure and it's organizational implications.

  • PDF

광양만 예비 영양류 모형 (A Preliminary Trophic Flow Model for Gwangyang Bay, Korea)

  • 강윤호
    • 한국수산과학회지
    • /
    • 제38권3호
    • /
    • pp.184-195
    • /
    • 2005
  • A preliminary quantitative model of the trophic structure in Gwangyang bay, Korea was obtained using ECOPATH and data from relevant studies to date in the region. The model integrates and analyzes biomass, food spectrum, trophic interactions and the key trophic pathways of the system. The bay model comprises 9 groups of benthic primary producer, phytoplankton, zooplankton, benthos, bivalve, pelagic fish, demersal fish and piscivorous fish. The total system throughput was estimated at $2.4\;kgWW/m^2/yr$, including a consumption of $41\%$, exports of $9\%$, respiratory flows of $24\%$ and flows into detritus of $26\%$. All of which originate from primary producers measured at $52\%$ and detritus of $48\%$. The total biomass was seen to be high compared to the levels of Somme, Delaware, Chesapeake Bays and Seine Estuary. This seems to be possibly due to artificial bivalve aquaculture and overestimation of benthos and benthic primary producer groups. The deviation can be calibrated by neglecting aquaculture and decreasing the habitat area for the groups. The trophic network of the bay shows a low level of recycling and organization as indicated by Finn's cycling index $3.3\%$, Ascendancy $3.1\;kgC/m^2/yr$ bits, Capacity $5.1\;kgC/m^2/yr$ bits and Redundancy $2.2\;kgC/m^2/yr$ bits. A high relative ascendancy of $62\%$ and a low internal relative ascendancy of $18\%$ indicate the system is not fully organized and stable towards disturbances, depending upon external connections. Although the model should be continuously provided with field data and calibrated further in depth, this study is the first trophic model applied to the region. The model can be a useful tool to understand the ecosystem in a quantitative manner.

The detection of cavitation in hydraulic machines by use of ultrasonic signal analysis

  • Gruber, P.;Farhat, M.;Odermatt, P.;Etterlin, M.;Lerch, T.;Frei, M.
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권4호
    • /
    • pp.264-273
    • /
    • 2015
  • This presentation describes an experimental approach for the detection of cavitation in hydraulic machines by use of ultrasonic signal analysis. Instead of using the high frequency pulses (typically 1MHz) only for transit time measurement different other signal characteristics are extracted from the individual signals and its correlation function with reference signals in order to gain knowledge of the water conditions. As the pulse repetition rate is high (typically 100Hz), statistical parameters can be extracted of the signals. The idea is to find patterns in the parameters by a classifier that can distinguish between the different water states. This classification scheme has been applied to different cavitation sections: a sphere in a water flow in circular tube at the HSLU in Lucerne, a NACA profile in a cavitation tunnel and two Francis model test turbines all at LMH in Lausanne. From the signal raw data several statistical parameters in the time and frequency domain as well as from the correlation function with reference signals have been determined. As classifiers two methods were used: neural feed forward networks and decision trees. For both classification methods realizations with lowest complexity as possible are of special interest. It is shown that two to three signal characteristics, two from the signal itself and one from the correlation function are in many cases sufficient for the detection capability. The final goal is to combine these results with operating point, vibration, acoustic emission and dynamic pressure information such that a distinction between dangerous and not dangerous cavitation is possible.

수직벽면형 무동력 태양열 시스템 작동성능에 관한 실험적 연구 (An experimental study on the operating performance of facade installed natural circulation type solar thermal system)

  • 백남춘;이왕제;이진국;이순명
    • 한국태양에너지학회 논문집
    • /
    • 제35권4호
    • /
    • pp.1-7
    • /
    • 2015
  • The operation of the natural circulation type solar heating systems with facade integrated collector was analyzed by experiment. Two different types of flat plate solar collectors were used for these experiments. One was for the normal flat plate solar collector with the size of 1m*2m and the other was for the large size solar collector with $4m^2$(1m*4m). The experiments were carried out to investigate the effect of the series or parallel connection method on the performance of the collectors. As a result, the solar thermal system which is installed on the wall or facade would be applicable for the natural circulation type if the system design reflects various parameters, including collector connecting method(series or parallel), to provide enough vertical height between collector and storage tank, and to reduce pressure loss due to collector and piping network, etc. The natural circulation type of solar thermal system as proposed in this study can increase the system reliability by removing or minimizing the use of the components such as pump, controller, sensors which may cause serious troubles of the system for a long-time operation

오일 용해도를 고려한 $CO_2$ 트윈 로타리 압축기 성능해석 (Solubility Consideration in Performance Analysis of a $CO_2$ Twin Rotary Compressor)

  • 김우영;안종민;김현진;조성욱
    • 설비공학논문집
    • /
    • 제19권12호
    • /
    • pp.842-849
    • /
    • 2007
  • For a $CO_2$ two-stage twin rotary compressor used for heat pump water heater system, changes of $CO_2$ solubility in PAG oil were investigated along the gas passages from the first stage suction to final discharge. Only slight changes in solubility took place in suction chambers for both of the first and second stages, but for compression chambers, solubility variation ranged from 0.115 to 0.136, and from 0.133 to 0.182, respectively for the first and second stages. Calculation of gas flashing in parts of leakage oil flows and of oil contained in control volumes due to solubility changes was conducted and included in gas pressure calculation. For the second stage, gas flashing amounts to around $5%\sim6%$ for most leakage flows. Cooling capacity, compressor input, and COP obtained by calculation were well compared to the experimental results. Effects of operation speed on the compressor performance was also studied: as the shaft speed increased, adiabatic efficiency decreased rapidly due to increased over-compression loss.

일방향 AGV 시스템 설계를 위한 시뮬레이터 개발 (Development of Simulator for Designing Unidirectional AGV Systems)

  • 이경재;서윤호
    • 한국시뮬레이션학회논문지
    • /
    • 제17권4호
    • /
    • pp.133-142
    • /
    • 2008
  • 생산시스템의 유연성과 효율성을 동시에 만족시키기 위한 자재취급 시스템으로써 AGV 시스템을 사용한다. AGV 시스템은 전체 생산시스템의 성능을 결정하는 중요 요인으로써 최적 설계안의 도출이 필수적이다. 일반적으로 상용 시뮬레이션 소프트웨어를 이용하여 AGV 시스템 설계 검증이 이루어지고 있지만, 이러한 검증 과정을 신속히 처리하기 위한 일련의 절차에 대한 개발이 필요하다. 본 연구에서는 근사최적화된 일방향 흐름 경로와 다양한 운영 파라미터를 고려할 수 있는 일방향 AGV 시스템 시뮬레이터의 아키텍처를 제시 및 개발 하였다. 개발된 AGV 시스템 시뮬레이터는 Java를 기반으로 개발되었으며, 타부탐색을 이용한 근사최적 일방향 네트워크 설계를 지원하고, 사용자가 쉽게AGV 시스템의 설계 검증 및 대안분석에 사용할 수 있도록 개발되었다. 사용자의 시스템 설계 운영 정보는 입력창을 통해 입력되며 이 정보는 레이아웃 생성기, AGV 운영계획 생성기, 통합 AGVS 생성기로 구성된 시뮬레이션 엔진에서 자동으로 AGV 시스템을 모델링 및 시뮬레이션을 하여 빠른 시간 안에 시뮬레이터 사용자에게 피드백을 제공한다.

  • PDF

Effects of Filler Characteristics and Processing Conditions on the Electrical, Morphological and Rheological Properties of PE and PP with Conductive Filler Composites

  • Kim, Youn-Hee;Kim, Dong-Hyun;Kim, Ji-Mun;Kim, Sung-Hyun;Kim, Woo-Nyon;Lee, Heon-Sang
    • Macromolecular Research
    • /
    • 제17권2호
    • /
    • pp.110-115
    • /
    • 2009
  • The electrical, morphological and rheological properties of melt and dry mixed composites of poly ethylene (PE)/graphite (Gr), polypropylene (PP)/Gr and PP/nickel-coated carbon fiber (NCCF) were investigated as a function of filler type, filler content and processing temperature. The electrical conductivities of dry mixed PP/NCCF composites were increased with decreasing processing temperature. For the melt mixed PP/NCCF composites, the electrical conductivities were higher than those of the melt mixed PE/Gr and PP/Gr composites, which was attributed to the effect of the higher NCCF aspect ratio in allowing the composites to form a more conductive network in the polymer matrix than the graphite does. From the results of morphological studies, the fillers in the dry mixed PP/NCCF composites were more randomly dispersed compared to those in the melt mixed PP/NCCF composites. The increased electrical conductivities of the dry mixed composites were attributed to the more random dispersion of NCCF compared to that of the melt mixed PP/NCCF composites. The complex viscosities of the PP/Gr composites were higher than those of the PP/NCCF composites, which was attributed to the larger diameter of the graphite particles than that of the NCCF. Furthermore, the fiber orientation in the 'along the flow' direction during melt mixing was attributed to the decreased complex viscosities of the melt mixed PP/NCCF composites compared those of the melt mixed PP/Gr composites.